• Title/Summary/Keyword: CT simulation

Search Result 365, Processing Time 0.025 seconds

COVID-19 Lung CT Image Recognition (COVID-19 폐 CT 이미지 인식)

  • Su, Jingjie;Kim, Kang-Chul
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.17 no.3
    • /
    • pp.529-536
    • /
    • 2022
  • In the past two years, Severe Acute Respiratory Syndrome Coronavirus-2(SARS-CoV-2) has been hitting more and more to people. This paper proposes a novel U-Net Convolutional Neural Network to classify and segment COVID-19 lung CT images, which contains Sub Coding Block (SCB), Atrous Spatial Pyramid Pooling(ASPP) and Attention Gate(AG). Three different models such as FCN, U-Net and U-Net-SCB are designed to compare the proposed model and the best optimizer and atrous rate are chosen for the proposed model. The simulation results show that the proposed U-Net-MMFE has the best Dice segmentation coefficient of 94.79% for the COVID-19 CT scan digital image dataset compared with other segmentation models when atrous rate is 12 and the optimizer is Adam.

Design of CT used Protection Relay by Electromagnetic Field Analysis (전자장 해석을 통한 보호 개전기용 CT 설계)

  • Sohn, Jong-Mahn;Song, Hee-Chan;Choe, Jong-Woong
    • Proceedings of the KIEE Conference
    • /
    • 1997.07a
    • /
    • pp.155-158
    • /
    • 1997
  • In design of current transformer, equivalent circuit parameters is obtained by electromagnetic analysis and used circuit simulation. Precise core secton area and turns of coil can be determined by circuit analysis. Therefore exact design of current transformer is possible by field and circuit analysis.

  • PDF

System Resolution Recovery by Motion Blur Recovery Technique - Particuar Application to X-ray Computerized Tomography (이동 Blur 회복법을 이용한 분해능 향상-X-ray C.T.에의 응용)

  • 이수영;김홍석
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.17 no.3
    • /
    • pp.26-35
    • /
    • 1980
  • The degradation of image due to the finite size of sensing devices has been one of the problems in all digital imaging systems. The basic study on the improvement of the spatial resolution was carried out in both spatial and frequency domains by the resolution recovery techniques which have been used in optics. Here, the techniques were applied to CT (Computerized Tomography) system, and image with finer resolution was obtained by these techniques. The basic theory is described and the results of the simulation are shown.

  • PDF

Performance Analysis of Buffer Allocation Schemes for Controlled Transfer Service in ATM Networks (ATM 망에서 CT 서비스를 위한 버퍼 할당 방식의 성능 분석)

  • 김병철;조유제안윤영권율
    • Proceedings of the IEEK Conference
    • /
    • 1998.10a
    • /
    • pp.261-264
    • /
    • 1998
  • Controlled transfer (CT) capability, a new ATM transfer capability (ATC) for high-speed data applications which using credit-based flow control, has recently been proposed and studied in ITU-T. In this paper, we review the existing dyanmic buffer allocation schemes and propose an improved scheme. Also, we compare the performances of the existing buffer allocation methods such as static allocation, flow controlled virtual channels (FCVC), and zero queueing flow control (ZQFC) with the proposed method through simulation. Simulation results show that the proposed scheme exhibits a better performance than the existing schemes in terms of throughput, fairness, queue length and link utilization.

  • PDF

Computer-Assisted Mandibular Reconstruction with Monocortical DCIA Flap; A Case Report

  • Moon, Seong-Yong
    • Journal of International Society for Simulation Surgery
    • /
    • v.2 no.2
    • /
    • pp.83-86
    • /
    • 2015
  • Recently, computer-assisted surgery is popular for performing well-planned operations. Computer-aided navigation system is helpful in maxillofacial surgery with real time instrument positioning and clear anatomic identification. Generally, segmental mandibulectomy and reconstruction flap surgery have done by extra-oral approach such as, submandibular approach. This case report describes performing intra-oral segmental mandibulectomy and reconstruction with monocortical deep circumflex iliac artery (DCIA) flap and CT guided implant surgery by using computer-aided surgical guide and navigation for managing ameloblastoma in a 31 years old female patient.

Automatic Segmentation of Vertebral Arteries in Head and Neck CT Angiography Images

  • Lee, Min Jin;Hong, Helen
    • Journal of International Society for Simulation Surgery
    • /
    • v.2 no.2
    • /
    • pp.67-70
    • /
    • 2015
  • We propose an automatic vessel segmentation method of vertebral arteries in CT angiography using combined circular and cylindrical model fitting. First, to generate multi-segmented volumes, whole volume is automatically divided into four segments by anatomical properties of bone structures along z-axis of head and neck. To define an optimal volume circumscribing vertebral arteries, anterior-posterior bounding and side boundaries are defined as initial extracted vessel region. Second, the initial vessel candidates are tracked using circular model fitting. Since boundaries of the vertebral arteries are ambiguous in case the arteries pass through the transverse foramen in the cervical vertebra, the circle model is extended along z-axis to cylinder model for considering additional vessel information of neighboring slices. Finally, the boundaries of the vertebral arteries are detected using graph-cut optimization. From the experiments, the proposed method provides accurate results without bone artifacts and eroded vessels in the cervical vertebra.

Image Registration for High-Quality Vessel Visualization in Angiography (혈관조영영상에서 고화질 혈관가시화를 위한 영상정합)

  • Hong, Helen;Lee, Ho;Shin, Yeong-Gil
    • Proceedings of the Korea Society for Simulation Conference
    • /
    • 2003.11a
    • /
    • pp.201-206
    • /
    • 2003
  • In clinical practice, CT Angiography is a powerful technique for the visualziation of blood flow in arterial vessels throughout the body. However CT Angiography images of blood vessels anywhere in the body may be fuzzy if the patient moves during the exam. In this paper, we propose a novel technique for removing global motion artifacts in the 3D space. The proposed methods are based on the two key ideas as follows. First, the method involves the extraction of a set of feature points by using a 3D edge detection technique based on image gradient of the mask volume where enhanced vessels cannot be expected to appear, Second, the corresponding set of feature points in the contrast volume are determined by correlation-based registration. The proposed method has been successfully applied to pre- and post-contrast CTA brain dataset. Since the registration for motion correction estimates correlation between feature points extracted from skull area in mask and contrast volume, it offers an accelerated technique to accurately visualize blood vessels of the brain.

  • PDF

Blood Flow Simulation in Bifurcated Geometry of Abdominal and Iliac Arteries Based on CT Images (CT영상에 기반한 복부대동맥과 장골동맥 분기관 모델의 혈류유동 해석)

  • Hong Y. S.;Kim M. C.;Kang H. M.;Lee C. S.;Kim C. J.;Lee J. M.;Kim D. S.;Lee K.
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.6
    • /
    • pp.497-503
    • /
    • 2004
  • Numerical simulation of blood flow has been conducted based on real vessel geometries generated front DICOM medical images of abdominal and iliac bifurcated arteries of a healthy man. A program was developed to read cross sectional images of the three dimensional arteries and smoothly extract boundary coordinates of vessels. Commercial programs were employed for mesh generation and flow simulation. Pressures, velocities, and flow distributions were found to lie within normal physiological ranges. Peak velocity measured in the iliac artery by ultrasound was 20% smaller than that obtained by simulation. The trend of velocity variation in a cardiac cycle was fairly similar between the simulation and the ultrasonic measurements. Simulation based on real vessel geometry of individual patient provides information on pressure, velocity, and its distribution in the diseased arteries or arteries to be surgically treated. The results of simulation may help surgeons to better understand hemodynamic status and surgical need of the patient by revealing variation of the hemodynamic parameters. Futhermore, they may serve as basic data for surgical treatment of arteries. This research is expected to develop to a program in the future that early diagnose atherosclerosis by showing distribution of a hemodynamic index closely related to atherosclerosis in arteries.

A Study on the Possibility of Pancreas Detection through Extraction of Effective Atomic Number using a Simulation such as Dual-energy CT (이중에너지 CT와 같은 시뮬레이션을 이용한 유효원자번호 추출을 통한 췌장 검출 가능성 연구)

  • Son, Ki-Hong;Lee, Soo-Yeul;Chung, Myung-Ae;Kim, Dae-Hong
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.5
    • /
    • pp.537-543
    • /
    • 2022
  • The purpose of this simulation study was to evaluate the possibility of pancreas detection through effective atomic number information using dual-energy computed tomography(CT). The effective atomic number of 10 tissue-equivalent materials were estimated through stoichiometric calibration. For stoichiometric calibration, HU values at low-energy (80 kV) and high-energy (140 kV) for 10 tissue-equivalent materials were used. Based on this method, the effective atomic number image of the tissue-equivalent material was extracted through an iterative algorithm. According to the results, the attenuation ratio in accordance with the effective atomic number was estimated to have an R2 value of 0.9999, and the effective atomic number of Pancreas, Water, Liver, Blood, Spongiosa, and Cortical bone was overall within 1% accuracy compared to the theoretical value. Conventional pancreatic cancer examination uses a contrast medium, so there is a possibility of potential side effects of the contrast medium. In order to solve this problem, it is thought that it will be possible to contribute to an accurate and safe examination by extracting the effective atomic number using dual-energy CT without contrast enhancement. Based on this study, future research will be conducted on the detection of pancreatic cancer using the HU value of pancreatic cancer based on clinical images.

Design and Simulation of Active Power Filter (전력 능동 필터의 설계 및 시뮬레이션)

  • 정동열;박종연;방선배
    • Proceedings of the IEEK Conference
    • /
    • 2003.07c
    • /
    • pp.2629-2632
    • /
    • 2003
  • This paper presents the harmonics rejection technique and the simulation of a active power filter using power operational amplifier. The proposed active power filter consists of CT(current transformer), harmonics detector and harmonics amplifier. The harmonics detector is a high pass filter using a GIC(Generalized Impedance Converter). The harmonics amplifier consists of a power operational amplifier and passive filters. The simulation has been implemented by OR-CAD program. It is examined whether the proposed active power filter can be realized or not through simple experiments.

  • PDF