• Title/Summary/Keyword: CT simulation

Search Result 365, Processing Time 0.026 seconds

Analysis of Beam Hardening of Modulation Layers for Dual Energy Cone-beam CT (에너지 변조 필터로 구현한 이중 에너지 콘빔 CT의 에너지 스펙트럼 평가 연구)

  • Ahn, Sohyun;Cho, Sam Ju;Keum, Ki Chang;Choi, Sang Gyu;Lee, Rena
    • Progress in Medical Physics
    • /
    • v.27 no.1
    • /
    • pp.8-13
    • /
    • 2016
  • Dual energy cone-beam CT can distinguish two materials with different atomic compositions. The principle of dual energy cone-beam CT based on modulation layer is that higher energy spectrum can be acquired at blocked x-ray window. To evaluate the possibility of modulation layer based dual energy cone-beam CT, we analyzed x-ray spectrum for various thicknesses of modulation layers by Monte Carlo simulation. To compare with the results of simulation, the experiment was performed on prototype cone-beam CT for 50~100 kVp with CdTe XR-100T detector. As the result of comparing, the mean energy of energy spectrum for 80 kVp are well matched with that of simulation. The mean energy of energy spectrum for 80 and 120 kVp were increased as 1.67 and 1.52 times by 2.0 mm modulation layer, respectively. We realized that the virtual dual energy x-ray source can be generated by modulation layer.

Simulation of lesion-to-liver contrast difference curves in Dynamic Hepatic CT with Pharmacokinetic Compartment Modeling (Pharmacokinetic Compartment Modeling을 이용한 나선식 CT에서의 간암-간 대조 곡선의 Simulation)

  • S.J. Kim;K.H. Lee;J.H. Kim;J.K. Han;B.G. Min
    • Journal of Biomedical Engineering Research
    • /
    • v.20 no.2
    • /
    • pp.173-182
    • /
    • 1999
  • Contrast-enhanced CT has an important role in assessing liver lesions, the optimal protocol to get most effective result is not clear. The mein goal when deciding injention protocol is to optimize lesion detectability with rapid scanning when lesion to liver contrast is maximum. For this purpose, we developed a physiological model of the contrast medium enhancement based on the compartment modeling and pharmacokinetics. Blood supply to liver is achieved in two paths. This dual supply characteristic distinguishes the CT enhancement of liver from that of the other organs. The first path is by hepatic artery and to second, by portal vein. However, it is assumed that only gepatic artery can supply blood to hepatocellular carcinoma(HCC) compartment, thus, the difference of contrast enhancement is resulted between normal liver tissue and hepatic tumor. By solving differential equations for each compartment simultaneously using the computer program Matlab, CT contrast-enhancement curves were simulated. The simulated enhancement curves for aortic, hepatic, portal vein, and HCC compartments were compared with the mean enhancement curves from 24 patients exposed to the same protocols as the simulation. These enhancement curves showed a good agreement. Furthermore, we simulated lesion-to-liver curves for various injection protocols, and the effects were analyzed. The variables to be considered in the injection protocol were injection rate, dose, and concentration of contrast material. These data may help to optimize scanning protocols for better diagnosis.

  • PDF

Surgical Simulation Environment for Replacement of Artificial Knee Joint (CT 영상을 이용한 무릎관절 모의 치환 시술 환경)

  • Kim, Dong-Min
    • Journal of IKEEE
    • /
    • v.7 no.1 s.12
    • /
    • pp.119-126
    • /
    • 2003
  • This paper presents a methodology for constructing a surgical simulation environment for the replacement of artificial knee join using CT image data. We provide a user interface of preoperative planning system for performing complex 3-D spatial manipulation and reasoning tasks. Simple manipulation of joystick and mouse has been proved to be both intuitive and accurate for the fitness and the wear expect of joint. The proposed methodology are useful for future virtual medical system where all the components of visualization, automated model generation, and surgical simulation are integrated.

  • PDF

Application of 3D Simulation Surgery to Orbital Wall Fracture : A preliminary Case Study

  • Choi, Jong-Woo
    • Journal of International Society for Simulation Surgery
    • /
    • v.1 no.1
    • /
    • pp.16-18
    • /
    • 2014
  • The orbit has a very special anatomical structure. The complex anatomical structure should be restored when we encounter the patient with orbital wall fracture. Unless these specific anatomy were reconstructed well, the patient should suffer from various complications such enophthalmos, diplopia or orbital deformity. In addition, because the patient has a his own specific orbital shape, individualized approach will be necessary. The aim of this trial is to try to restore the original orbit anatomy as possible based on the mirrored three dimensional CT images based on the computer simulation. Preoperative computed tomography (CT) data were processed for the patient and a rapid prototyping (RP) model was produced. At the same time, the uninjured side was mirrored and superimposed onto the traumatized side, to create a mirror-image of the RP model. In order to restore the missing skipped images between the cuts of CT data because of the thinness of the orbital walls, we manipulated the DICOM data for imaging the original orbital contour using the preoperatively manufactured mirror-image of the RP model. And we fabricated Titanium-Medpor to reconstruct three-dimensional orbital structure intraoperatively. This prefabricated Titanium-Medpor was then inserted onto the defected orbital wall and fixed. Three dimensional approach based on the computer simulation turned out to be very successful in this patient. Individualized approach for each patient could be an ideal way to manage the traumatic patients in near future.

A Study into the Effect of the CT Simulation Program on Clinical Education (전산화단층촬영 시뮬레이션 프로그램의 임상교육 효과에 관한 연구)

  • Kim, Yong-Wan;Kim, Jung-Sam;Lee, Kyung-Rok
    • Journal of radiological science and technology
    • /
    • v.32 no.4
    • /
    • pp.445-451
    • /
    • 2009
  • The computed tomography(CT) simulation tool provides virtual experimental environment without using a high cost medical equipment. We made teaching materials for the CT simulation tools and educated the students and entry level of radio-technologists. We divided the experimental objects into two groups; students who took only theoretical classes (group 1) and students who took both theoretical and simulation classes (group 2). The results showed that the group 2 outperformed group 1 significantly, which indicates that the simulation program provides a good educational material for not only students but also radio-technologists.

  • PDF

Application of BMP for Reduction of Runoff and NPS Pollutions (강우유출수와 비점오염물질을 저감하기 위한 최적관리기법의 적용)

  • Won, Chul-Hee;Shin, Min-Hwan;Shin, Hyun-Jun;Lim, Kyoung-Jay;Choi, Joong-Dae
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.55 no.5
    • /
    • pp.1-7
    • /
    • 2013
  • The objective of this research was to experimentally test the effect of tillage methods on the reduction of runoff, non-point source (NPS) pollution load, sediment and discharge under a rainfall simulation. We used the runoff plots of $5m{\times}30m$ ($L{\times}W$) in size. Experimental treatments were conventional tillage (CT), CT-rice straw bundle (CT-RSB) and two no-till (NT) plots; slope of 3 % or 8 % ; and rainfall intensity of 30 mm/hr. The rainfall simulation was conducted to three times. The time to initial runoff from NT plots was less than that from CT plots regardless of the slope and it was delayed about 65~90 % compared to that of CT plot. And sediment discharge of 8 % slope reduced to 55 % compared to CT plot. But the sediment discharge was not occurred at 3 % slope. The NT and CT-RSB methods have a great possibility of reducing runoff and NPS pollution loads. Runoff rate of NT plots was significantly lower than those of CT plot. The average NPS pollution loads of the NT plots and CT-RSB plot reduced about 55~80 % and 2.1~40 % compared to those of the CT plots, respectively. It was also shown that runoff and NPS pollution loads reduction by NT method could be very significant and contribute to improve the water quality of streams in agricultural regions. It was concluded that the use of NT method on agricultural fields could reduce soil erosion and muddy runoff significantly and help improve the water quality and aquatic ecosystem.

Exploring Students Competencies to be Creative Problem Solvers With Computational Thinking Practices

  • Park, Young-Shin;Park, Miso
    • Journal of the Korean earth science society
    • /
    • v.39 no.4
    • /
    • pp.388-400
    • /
    • 2018
  • The purpose of this study was to explore the nine components of computational thinking (CT) practices and their operational definitions from the view of science education and to develop a CT practice framework that is going to be used as a planning and assessing tool for CT practice, as it is required for students to equip with in order to become creative problem solvers in $21^{st}$ century. We employed this framework into the earlier developed STEAM programs to see how it was valid and reliable. We first reviewed theoretical articles about CT from computer science and technology education field. We then proposed 9 components of CT as defined in technology education but modified operational definitions in each component from the perspective of science education. This preliminary CTPF (computational thinking practice framework) from the viewpoint of science education consisting of 9 components including data collection, data analysis, data representation, decomposing, abstraction, algorithm and procedures, automation, simulation, and parallelization. We discussed each component with operational definition to check if those components were useful in and applicable for science programs. We employed this CTPF into two different topics of STEAM programs to see if those components were observable with operational definitions. The profile of CT components within the selected STEAM programs for this study showed one sequential spectrum covering from data collection to simulation as the grade level went higher. The first three data related CT components were dominating at elementary level, all components of CT except parallelization were found at middle school level, and finally more frequencies in every component of CT except parallelization were also found at high school level than middle school level. On the basis of the result of CT usage in STEAM programs, we included 'generalization' in CTPF of science education instead of 'parallelization' which was not found. The implication about teacher education was made based on the CTPF in terms of science education.

A Study for CT Technology Valuation Methods (CT기술 가치평가에 관한 연구)

  • Ham, Hyung-Bum;Lee, Yang-Sun;Kim, Ki-Hoon;Jung, Woo-Chai
    • Journal of Korea Multimedia Society
    • /
    • v.9 no.8
    • /
    • pp.1086-1094
    • /
    • 2006
  • The CT is all relation knowledge and technology which are applied to make the culture contents. Recently demand regarding the CT is increasing rapidly with a great growth and high technology of culture contents industry. In this paper we suggest a CT technology valuation model for promoting R & D results and technical diffusion of the CT. Also, It is shown how to derive a value of the CT using simulation. For it, we study a classification and distinctive characteristics of the CT. And this paper reviews the methods of technology valuation that have been developed by valuation specialists.

  • PDF

A study of usefulness for the plan based on only MRI using ViewRay MRIdian system (ViewRay MRIdian System을 이용한 MRI only based plan의 유용성 고찰)

  • Jeon, Chang Woo;Lee, Ho Jin;An, Beom Seok;Kim, Chan young;Lee, Je hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.2
    • /
    • pp.131-143
    • /
    • 2015
  • Purpose : By comparing a CT fusion plan based on MRI with a plan based on only MRI without CT, we intended to study usefulness of a plan based on only MRI. And furthermore, we intended to realize a realtime MR-IGRT by MRI image without CT scan during the course of simulation, treatment planning, and radiation treatment. Materials and Methods : BBB CT (Brilliance Big Bore CT, 16slice, Philips), Viewray MRIdian system (Viewray, USA) were used for CT & MR simulation and Treatment plan of 11 patients (1 Head and Neck, 5 Breast, 1 Lung, 3 Liver, 1 Prostate). When scanning for treatment, Free Breathing was enacted for Head&Neck, Breast, Prostate and Inhalation Breathing Holding for Lung and Liver. Considering the difference of size between CT and Viewray, the patient's position and devices were in the same condition. Using Viewray MRIdian system, two treatment plans were established. The one was CT fusion treatment plan based on MR image. Another was MR treatment plan including electron density that [ICRU 46] recommend for Lung, Air and Bone. For Head&Neck, Breast and Prostate, IMRT was established and for Lung and Liver, Gating treatment plan was established. PTV's Homogeneity Index(HI) and Conformity Index(CI) were use to estimate the treatment plan. And DVH and dose difference of each PTV and OAR were compared to estimate the treatment plan. Results : Between the two treatment plan, each difference of PTV's HI value is 0.089% (Head&Neck), 0.26% (Breast), 0.67% (Lung), 0.2% (Liver), 0.4% (Prostate) and in case of CI, 0.043% (Head&Neck), 0.84% (Breast), 0.68% (Lung), 0.46% (Liver), 0.3% (Prostate). As showed above, it is on Head&Neck that HI and CI's difference value is smallest. Each difference of average dose on PTV is 0.07 Gy (Head&Neck), 0.29 Gy (Breast), 0.18 Gy (Lung), 0.3 Gy (Liver), 0.18 Gy (Prostate). And by percentage, it is 0.06% (Head&Neck), 0.7% (Breast), 0.29% (Lung), 0.69% (Liver), 0.44% (Prostate). Likewise, All is under 1%. In Head&Neck, average dose difference of each OAR is 0.01~0.12 Gy, 0.04~0.06 Gy in Breast, 0.01~0.21 Gy in Lung, 0.06~0.27 Gy in Liver and 0.02~0.23 Gy in Prostate. Conclusion : PTV's HI, CI dose difference on the Treatment plan using MR image is under 1% and OAR's dose difference is maximum 0.89 Gy as heterogeneous tissue increases when comparing with that fused CT image. Besides, It characterizes excellent contrast in soft tissue. So, radiation therapy using only MR image without CT scan is useful in the part like Head&Neck, partial breast and prostate cancer which has a little difference of heterogeneity.

  • PDF

Image Reconstruction of Sinogram Restoration using Inpainting method in Sparse View CT (Sparse view CT에서 inpainting 방법을 이용한 사이노그램 복원의 영상 재구성)

  • Kim, Daehong;Baek, Cheol-Ha
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.7
    • /
    • pp.655-661
    • /
    • 2017
  • Sparse view CT has been widely used to reduce radiation dose to patient in radiation therapy. In this work, we performed sinogram restoration from sparse sampling data by using inpainting method for simulation and experiment. Sinogram restoration was performed in accordance with sampling angle and restoration method, and their results were validated with root mean square error (RMSE) and image profiles. Simulation and experiment are designed to fan beam scan for various projection angles. Sparse data in sinogram were restored by using linear interpolation and inpainting method. Then, the restored sinogram was reconstructed with filtered backprojection (FBP) algorithm. The results showed that RMSE and image profiles were depended on the projection angles and restoration method. Based on the simulation and experiment, we found that inpainting method could be improved for sinogram restoration in comparison to linear interpolation method for estimating RMSE and image profiles.