• Title/Summary/Keyword: CT simulation

Search Result 365, Processing Time 0.026 seconds

Estimation of Change in Soil Carbon Stock of Pinus densiflora Forests in Korea using KFSC Model under RCP 8.5 Climate Change Scenario (한국형 산림토양탄소모델(KFSC Model)을 이용한 RCP 8.5 기후변화 시나리오 하에서의 국내 소나무림 토양탄소 저장량 장기 변화 추정 연구)

  • Park, Chan-woo;Lee, Jongyeol;Yi, Myongjong;Kim, Choonsig;Park, Gwan Soo;Kim, Rae Hyun;Lee, Kyeong Hak;Son, Yowhan
    • Journal of Climate Change Research
    • /
    • v.4 no.2
    • /
    • pp.77-93
    • /
    • 2013
  • Global warming accelerates both carbon (C) input through increased forest productivity and heterotrophic C emission in forest soils, and a future trend in soil C dynamics is uncertain. In this study, the Korean forest soil carbon model (KFSC model) was applied to 1,467,458 ha of Pinus densiflora forests in Korea to predict future C dynamics under RCP 8.5 climate change scenario (RCP scenario). Korea was divided into 16 administrative regions, and P. densiflora forests in each region were classified into six classes by their stand ages : 1 to 10 (I), 11 to 20 (II), 21 to 30 (III), 31 to 40 (IV), 41 to 50 (V), and 51 to 80-year-old (VI+). The forest of each stand age class in a region was treated as a simulation unit, then future net primary production (NPP), soil respiration (SR) and forest soil C stock of each simulation unit were predicted from the 2012 to 2100 under RCP scenario and constant temperature scenario (CT scenario). As a result, NPP decreased in the initial stage of simulation then increased while SR increased in the initial stage of simulation then decreased in both scenarios. The mean NPP and SR under RCP scenario was 20.2% and 20.0% higher than that under CT scenario, respectively. When the initial age class was I, IV, V or VI+, predicted soil C stock under CT scenario was higher than that under RCP scenario, however, the countertrend was observed when the initial age class was II or III. Also, forests having a lower site index showed a lower soil C stock. It suggested that the impact of temperature on NPP was higher when the forests grow faster. Soil C stock under RCP scenario decreased at the end of simulation, and it might be derived from exponentially increased SR under the higher temperature condition. Thus, the difference in soil C stock under two scenarios will be much larger in the further future.

Development of pre-procedure virtual simulation for challenging interventional procedures: an experimental study with clinical application

  • Seong, Hyunyoung;Yun, Daehun;Yoon, Kyung Seob;Kwak, Ji Soo;Koh, Jae Chul
    • The Korean Journal of Pain
    • /
    • v.35 no.4
    • /
    • pp.403-412
    • /
    • 2022
  • Background: Most pain management techniques for challenging procedures are still performed under the guidance of the C-arm fluoroscope although it is sometimes difficult for even experienced clinicians to understand the modified three-dimensional anatomy as a two-dimensional X-ray image. To overcome these difficulties, the development of a virtual simulator may be helpful. Therefore, in this study, the authors developed a virtual simulator and presented its clinical application cases. Methods: We developed a computer program to simulate the actual environment of the procedure. Computed tomography (CT) Digital Imaging and Communications in Medicine (DICOM) data were used for the simulations. Virtual needle placement was simulated at the most appropriate position for a successful block. Using a virtual C-arm, the authors searched for the position of the C-arm at which the needle was visualized as a point. The positional relationships between the anatomy of the patient and the needle were identified. Results: For the simulations, the CT DICOM data of patients who visited the outpatient clinic was used. When the patients revisited the clinic, images similar to the simulated images were obtained by manipulating the C-arm. Transforaminal epidural injection, which was difficult to perform due to severe spinal deformity, and the challenging procedures of the superior hypogastric plexus block and Gasserian ganglion block, were successfully performed with the help of the simulation. Conclusions: We created a pre-procedural virtual simulation and demonstrated its successful application in patients who are expected to undergo challenging procedures.

Master-Slave type DC-DC Converters Parallel Operation by ZCT method (ZCT방식의 master-slave형 DC-DC컨버터 병렬운전)

  • 박상은;송승찬;진정태;이기홍;성세진
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.655-658
    • /
    • 1999
  • In this paper, Parallel operation of two DC-DC converters which we have ever done before need two CTs to do load current sharing. However, we have proposed a new method called ZCT method that can share load current with only a CT as doing parallel operation two converters with same converter capacity. To confirm parallel performance by a proposed DC-DC converter parallel operation method, we have done computer simulation and experiment. It is certain that we have showed to achieve two converters current sharing performance efficiently through simulation and experiment at result.

  • PDF

Research and Consideration of Eco-friendly Radiation Shielding using CT Contrast Agent (CT 조영제를 이용한 친환경적인 방사선 차폐에 관한 연구 및 고찰)

  • Sung-Gil Kim;Yeon-Sang Ji
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.6
    • /
    • pp.827-833
    • /
    • 2023
  • CT(Computed Tomography) contrast agents are commonly used in general hospitals and university hospitals when taking radiographic examinations. The CT contrast medium contains a mixture of a substance called "Iodine", which absorbs radiation energy and makes it appear white in the CT image, further improving the image quality. In addition, the CT contrast agent, which moves like blood in the blood vessels, clearly differentiates it from muscle and water, so CT contrast agents are widely used in hospitals. These CT contrast agents absorb X-rays, but in order to absorb X-rays, they must have a high density or a high radiation absorption coefficient. Since the CT contrast agent is injected into the blood vessels, if the density is high, the blood vessels are strained and the patient is in shock. For this reason, it is necessary to match the density similar to that of water and always pay attention to side effects. In addition, the amount of CT contrast medium is adjusted according to the patient's body shape, and the remaining contrast medium is discarded. However, This study tried to find out the idea of recycling it as a radiation shielding material. Since the CT contrast medium has a high radiation absorption coefficient at a density similar to that of water, the amount to absorb radiation is adjusted, the amount of contrast medium and the amount of water are adjusted, and the amount of radiation absorbed is determined by mixing with water. In addition, a study was conducted to find out the result of the difference in radiation absorption in various ways by comparing the radiation quality coefficient and absorption coefficient with other substances or materials in an environmentally friendly method harmless to the human body by mixing CT contrast medium and water.

A Prototype of Telepresent Surgical Simulation System (원격 모의 수술 시스템 프로토타입)

  • 남상아
    • Journal of the Korea Society for Simulation
    • /
    • v.6 no.2
    • /
    • pp.31-44
    • /
    • 1997
  • In medical applications, the cooperation work using computer network is in the spotlight as next generation technology, because it offers sharing of equipments, knowledge of specialists, and data and surmounts the limitations of geographical position and time. We present a prototype of telepresent surgical simulation system in this treatise. It is a telemedicine system using volume image, which is reconstructed from radiological images such as MRI and CT. It is used as a tool for surgical simulation among telepresent doctors. It provides the functions of conference control, volume reconstruction and manipulation, and multimedia database management among one server and multi-clients through high-speed network. It is implemented on Unix workstation using X-windows and C language, TCP/IP protocol and UNiSQL as DBMS.

  • PDF

Basic Data Analysis of the Quality Control for Patient Safety in Department of Radiation Oncologyat Yeungnam University Hospital (영남대학교병원의 환자안전을 위한 정도관리의 기초자료 분석)

  • Oh, Se An;Kim, Sung Kyu;Yea, Ji Woon;Kang, Min Kyu;Lee, Joon Ha;Lee, Rena
    • Progress in Medical Physics
    • /
    • v.26 no.2
    • /
    • pp.112-117
    • /
    • 2015
  • In order to establish the quality control on patient safety following the guideline presented by American Association of Physicists in Medicine (AAPM) TG-100 committee, we aim to analyze the modes based on errors occurred during treatment of patients at the radiation oncology department at Yeungnam University Hospital and establish a quality control guideline for patient safety when patient-centered radiation treatment is conducted. We aim to analyze the errors that can occur during radiation treatment at the radiation department, and assess the frequency of error, the severity of error affecting patients, and probability of proceeding without noticing error, with scores. The places where errors can take place were divided into CT simulation treatment room, treatment planning room, and treatment room for the analysis. In CT simulation treatment room, an error from using the immobilization device showed the highest Risk Priority Number (RPN) value of 60, and an error from simulation treatment information input showed the lowest of 6. In treatment planning room, an error from selecting the radiation dose calculation model showed the highest RPN value of 168, and an error of patient treatment start date showed the lowest of 36. In treatment room, a Table Bar error showed the highest RPN value of 252, a weight change error showed 190, and a Pillow error showed the lowest of 24.

How Image Quality Affects Determination of Target Displacement When Using kV Cone-beam Computed Tomography (CBCT) (kV Cone-beam CT를 사용한 치료준비에서 재구성 영상의 품질이 표적 위치 결정에 미치는 영향)

  • Oh, Seung-Jong;Kim, Si-Yong;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.17 no.4
    • /
    • pp.207-211
    • /
    • 2006
  • The advent of kV cone-beam computed tomography (CBCT) integrated with a linear accelerator allows for more accurate Image-guided radiotherapy (IGRT). IGRT is the technique that corrects target displacement based on internal body information. To do this, the CBCT Image set is acquired just before the beam is delivered and registered with the simulation CT Image set. In this study, we compare the registration results according to the CBCT's reconstruction quality (either high or medium). A total of 56 CBCT projection data from 6 patients were analyzed. The translation vector differences were within 1 mm in all but 3 cases. For rotation displacement difference, components of all three axes were considered and 3 out of 168 ($56{\times}3$ axes) cases showed more than lo of rotation differences.

  • PDF

Convergence Study on Composite Material of Unidirectional CFRP and SM 45C Sandwich Type that Differs in Stacking Angle (적층각도가 다른 단방향 CFRP와 SM45C샌드위치형 복합재료에 관한 융합적 연구)

  • Park, Jae-Woong;Cho, Jae-Ung
    • Journal of the Korea Convergence Society
    • /
    • v.8 no.7
    • /
    • pp.231-236
    • /
    • 2017
  • In this study, the inhomogeneous material composed of CFRP(carbon fiber reinforced plastic) and structural metal of SM45C is used for the light material. The finite element analysis on the basis of compact tension test was carried out by using the composite material for sandwich type bonded with the unidirectional CFRP that differs in fiber stacking angle at both sides with the core of SM 45C. CT test is the representative method to confirm the fracture behaviour due to crack in material under the load. The effect on crack and hole must be investigated in order to apply inhomogeneous material to mechanical structure. As the result of this study, the fracture behaviour by CT test of the composite material for sandwich was studied by simulation analysis. The sandwich composite of unidirectional CFRP with the stacking angle of [0/60/-60/0] has the superior strength and the maximum equivalent stress of about 182GPa.Also, the esthetic sense can be shown as the designed factor of shape with composite material is grafted onto the convergence technique.

Efficient Determination of Iteration Number for Algebraic Reconstruction Technique in CT (CT의 대수적재구성기법에서 효율적인 반복 횟수 결정)

  • Joon-Min, Gil;Kwon Su, Chon
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.1
    • /
    • pp.141-148
    • /
    • 2023
  • The algebraic reconstruction technique is one of the reconstruction methods in CT and shows good image quality against noise-dominant conditions. The number of iteration is one of the key factors determining the execution time for the algebraic reconstruction technique. However, there are some rules for determining the number of iterations that result in more than a few hundred iterations. Thus, the rules are difficult to apply in practice. In this study, we proposed a method to determine the number of iterations for practical applications. The reconstructed image quality shows slow convergence as the number of iterations increases. Image quality 𝜖 < 0.001 was used to determine the optimal number of iteration. The Shepp-Logan head phantom was used to obtain noise-free projection and projections with noise for 360, 720, and 1440 views were obtained using Geant4 Monte Carlo simulation that has the same geometry dimension as a clinic CT system. Images reconstructed by around 10 iterations within the stop condition showed good quality. The method for determining the iteration number is an efficient way of replacing the best image-quality-based method, which brings over a few hundred iterations.

Computational Analysis of Airflow in Upper Airway for Drug Delivery of Asthma Inhaler (천식 흡입기의 약물전달을 위한 상기도내의 유동해석)

  • Lee, Gyun-Bum;Kim, Sung-Kyun
    • Transactions of the KSME C: Technology and Education
    • /
    • v.2 no.2
    • /
    • pp.73-80
    • /
    • 2014
  • Drug delivery in human upper airway was studied by the numerical simulation of oral airflow. We created an anatomically accurate upper airway model from CT scan data by using a medical image processing software (Mimics). The upper airway was composed of oral cavity, pharynx, larynx, trachea, and second generations of branches. Thin sliced CT data and meticulous refinement of model surface under the ENT doctor's advice provided more sophisticated nasal cavity models. With this 3D upper airway models, numerical simulation was conducted by ANSYS/FLUENT. The steady inspiratory airflows in that model was solved numerically for the case of flow rate of 250 mL/s with drug-laden spray(Q= 20, 40, 60 mL/s). Optimal parameters for mechanical drug aerosol targeting of predetermined areas was to be computed, for a given representative upper airways. From numerical flow visualization results, as flow-rate of drug-laden spray increases, the drag spray residue in oral cavity was increased and the distribution of drug spray in trachea and branches became more homogeneous.