• 제목/요약/키워드: CT scan type

검색결과 104건 처리시간 0.026초

Discrepancy of the location of depression on the soft tissue and the bone in isolated zygomatic arch fracture

  • Yong Jig Lee;Dong Gil Han;Se Hun Kim;Jeong Su Shim;Sung-Eun Kim
    • 대한두개안면성형외과학회지
    • /
    • 제24권1호
    • /
    • pp.18-23
    • /
    • 2023
  • Background: When performing reduction of zygomatic arch fractures, locating the inward portion of the fracture can be difficult. Therefore, this study investigated the discrepancy between the locations of the depression on the soft tissue and bone and sought to identify how to determine the inward portion of the fracture on the patient's face. Methods: We conducted a retrospective review of chart with isolated zygomatic arch fractures of type V in the Nam and Jung classification from March 2013 to February 2022. For consistent measurements, a reference point (RP), at the intersection between a vertical line passing through the end point of the root of the ear helix in the patient's side-view photograph and a transverse line passing through the longest horizontal axis of the external meatus opening, was established. We then measured the distance between the RP and the soft tissue depression in a portrait and the bone depression on a computed tomography (CT) scan. The discrepancy between these distances was quantified. Results: Among the patients with isolated zygomatic arch fractures, only those with a fully visible ear on a side-view photograph were included. Twenty-four patients met the inclusion criteria. There were four types of discrepancies in the location of the soft tissue depression compared to the bone depression: type I, forward and upward discrepancy (7.45 and 3.28 mm), type II, backward and upward (4.29 and 4.21 mm), type III, forward and downward (10.06 and 5.15 mm), and type IV, backward and downward (2.61 and 3.27 mm). Conclusion: This study showed that discrepancy between the locations of the depressions on the soft tissue and bone exists in various directions. Therefore, applying the transverse and vertical distances measured from a bone image of the CT scan onto the patient's face at the indicated RP will be helpful for predicting the reduction location.

Effect of angulation on the 3D trueness of conventional and digital implant impressions for multi-unit restorations

  • Ozay Onoral;Sevcan Kurtulmus-Yilmaz;Dilem Toksoy;Oguz Ozan
    • The Journal of Advanced Prosthodontics
    • /
    • 제15권6호
    • /
    • pp.290-301
    • /
    • 2023
  • PURPOSE. The study aimed to determine the influence of implant angulation on the trueness of multi-unit implant impressions taken through different techniques and strategies. MATERIALS AND METHODS. As reference models, three partially edentulous mandibular models (Model 1: No angulation; Model 2: No angulation for #33, 15-degree distal angulation for #35 and #37; Model 3: No angulation for #33, 25-degree distal angulation for #35 and #37) were created by modifying the angulations of implant analogues. Using a lab scanner, these reference models were scanned. The obtained data were preserved and utilized as virtual references. Three intraoral scanning (IOS) strategies: IOS-Omnicam, ISO-Quadrant, and IOS-Consecutive, as well as two traaditional techniques: splinted open tray (OT) and closed tray (CT), were used to create impressions from each reference model. The best-fit alignment approach was used to sequentially superimpose the reference and test scan data. Computations and statistical analysis of angular (AD), linear (LD), and 3D deviations (RMS) were performed. RESULTS. Model type, impression technique, as well as interaction factor, all demonstrated a significant influence on AD and LD values for all implant locations (P < .05). The Model 1 and SOT techniques displayed the lowest mean AD and LD values across all implant locations. When considering interaction factors, CT-Model 3 and SOT-Model 1 exhibited the highest and lowest mean AD and LD values, respectively. Model type, impression technique, and interaction factor all revealed significant effects on RMS values (P ≤ .001). CT-Model 3 and SOT-Model 1 presented the highest and lowest mean RMS values, respectively. CONCLUSION. Splinted-OT and IOS-Omnicam are recommended for multi-unit implant impressions to enhance trueness, potentially benefiting subsequent manufacturing stages.

Cross-Sectional and Skeletal Anatomy of Long-tailed Gorals (Naemorhedus caudatus) Using Imaging Evaluations

  • Sangjin Ahn;Woojin Shin;Yujin Han;Sohwon Bae;Cheaun Cho ;Sooyoung Choi;Jong-Taek Kim
    • Journal of Veterinary Science
    • /
    • 제24권4호
    • /
    • pp.60.1-60.8
    • /
    • 2023
  • Background: Accurate diagnosis of diseases in animals is crucial for their treatment, and imaging evaluations such as radiographs, computed tomography (CT), and magnetic resonance imaging (MRI) are important tools for this purpose. However, a cross-sectional anatomical atlas of normal skeletal and internal organs of long-tailed gorals (Naemorhedus caudatus) has not yet been prepared for diagnosing their diseases. Objectives: The objective of this study was to create an anatomical atlas of gorals using CT and MRI, which are imaging techniques that have not been extensively studied in this type of wild animal in Korea. Methods: The researchers used CT and MRI to create an anatomical atlas of gorals, and selected 37 cross-sections from the head, thoracic, lumbar, and sacrum parts of gorals to produce an average cross-sectional anatomy atlas. Results: This study successfully created an anatomical atlas of gorals using CT and MRI. Conclusions: The atlas provides valuable information for the diagnosis of diseases in gorals, which can improve their treatment and welfare. The study highlights the importance of developing cross-sectional anatomical atlases of gorals to diagnose and treat their diseases effectively.

Atypical presentation of DeBakey type I aortic dissection mimicking pulmonary embolism in a pregnant patient: a case report

  • Sou Hyun Lee;Ji Hee Hong;Chaeeun Kim
    • Journal of Yeungnam Medical Science
    • /
    • 제41권2호
    • /
    • pp.128-133
    • /
    • 2024
  • Aortic dissection in pregnant patients results in an inpatient mortality rate of 8.6%. Owing to the pronounced mortality rate and speed at which aortic dissections progress, efficient early detection methods are crucial. Here, we highlight the importance of early chest computed tomography (CT) for differentiating aortic dissection from pulmonary embolism in pregnant patients with dyspnea. We present the unique case of a 38-year-old pregnant woman with elevated D-dimer and N-terminal pro-brain natriuretic peptide (NT-proBNP) levels, initially suspected of having a pulmonary embolism. Initial transthoracic echocardiography did not indicate aortic dissection. Surprisingly, after an emergency cesarean section, a chest CT scan revealed a DeBakey type I aortic dissection, indicating a diagnostic error. Our findings emphasize the need for early chest CT in pregnant patients with dyspnea and elevated D-dimer and NT-proBNP levels. This case report highlights the critical importance of considering both aortic dissection and pulmonary embolism in the differential diagnosis of such cases, which will inform future clinical practice.

소아 두부외상 환자에서의 반복적인 두부 CT 검사의 유용성 (Value of Repeat Brain Computed Tomography in Children with Traumatic Brain Injury)

  • 조호준;임용수;김진주;조진성;현성열;양혁준;이근
    • Journal of Trauma and Injury
    • /
    • 제28권3호
    • /
    • pp.149-157
    • /
    • 2015
  • Purpose: Traumatic brain injury (TBI) is the most common cause of pediatric trauma patients came to the emergency department. Without guidelines, many of these children underwent repeat brain computed tomography (CT). The purpose of this study was to evaluate the value of repeat brain CT in children with TBI. Methods: We conducted a retrospective study of TBI in children younger than 19 years of age who visited the emergency department (ED) from January 2011 to December 2012. According to the Glasgow Coma Scale (GCS) and Pediatric Glasgow Coma Scale score of the patients, study population divided in three groups. Clinical data collected included age, mechanism of injury, type of TBI, and outcome. Results: A Total 83 children with TBI received repeat brain CT. There were no need for neurosurgical intervention in mild TBI (GCS score 13-15) group who underwent routine repeat CT. 4 patients of mild TBI group, received repeat brain CT due to neurological deterioration, and one patient underwent neurosurgical intervention. Routine repeat CT identified 12 patients with radiographic progression. One patient underwent neurosurgical intervention based on the second brain CT finding, who belonged to the moderate TBI (GCS score 9-12) group. Conclusion: Our study showed that children with mild TBI can be observed without repeat brain CT when there is no evidence of neurologic deterioration. Further study is needed for establish indication for repetition of CT scan in order to avoid unnecessary radiation exposure of children.

  • PDF

외과적으로 확진된 이첨 대동맥 판막의 진단을 위한 심장 CT 및 경흉부 심초음파의 진단적 성능: 판막 아형 및 칼슘의 양이 미치는 효과 (Diagnostic Performance of Cardiac CT and Transthoracic Echocardiography for Detection of Surgically Confirmed Bicuspid Aortic Valve: Effect of Calcium Extent and Valve Subtypes)

  • 김정주;김성목;안중현;김지훈;최연현
    • 대한영상의학회지
    • /
    • 제84권6호
    • /
    • pp.1324-1336
    • /
    • 2023
  • 목적 이첨 대동맥 판막의 아형과 판막 석회화의 정도에 따른 심장 CT와 경흉부심초음파의 이첨 대동맥 판막 진단 능력을 비교해 보고자 한다. 대상과 방법 대동맥 판막 치환술 전 심장 CT와 경흉부 심초음파를 시행한 266명의 환자(이첨 대동맥 판막, 106명; 삼첨 대동맥 판막, 166명)를 후향적으로 포함하였다. 심장 CT를 이용하여 판막의 모양을 평가하였고, 관상동맥 칼슘 측정 CT를 이용하여 판막의 칼슘 정도를 정량화하였다. 대동맥 판막은 융합형과 2-대동맥동형 아형으로 분류하였다. 심장 CT와 경흉부 심초음파의 진단정확도는 수술 소견을 대비표준으로 하여 계산하였다. 결과 CT는 이첨 대동맥 판막을 진단함에 있어서 경흉부 심초음파보다 민감도, 음성 예측도, 정확도에서 통계적으로 유의하게 높은 값을 보여주었다(각각 p < 0.001, p < 0.001, p = 0.003). 경흉부 심초음파는 판막의 석회화가 증가할수록 민감도가 감소하는 경향을 보였다. CT와 경흉부 심초음파 간의 진단 오류율은 2-대동맥동형 아형에서 10.9%, 융합형 아형에서 28.3%였다(p = 0.044). 결론 심장 CT는 이첨 대동맥 판막을 진단함에 있어 경흉부 심초음파보다 높은 진단능을 보여주며, 특히 판막 석회화가 심하거나 융합형의 아형인 환자에서 이첨 대동맥 판막을 진단하는데 도움을 줄 수 있다.

복부 CT 영상의 화질 개선 방법에 대한 연구 (Study on Methods to Improve Image Quality of Abdominal CT Images)

  • 최석윤
    • 한국방사선학회논문지
    • /
    • 제17권5호
    • /
    • pp.717-723
    • /
    • 2023
  • 간 질환을 포함한 여러 복부 질환은 사망에 영향을 줄 수 있다. 복부 질환 진료 시 전산화단층검사는(CT; Computed Tomography) 필수적으로 사용되고 있다. 판독에 유리한 영상을 만들기 위해서 높은 방사선 노출이 따르는데, 이에 대한 화질관리와 환자의 피폭 관리를 위한 다양한 노력이 필요하다. 복부 CT 영상의 화질개선을 위해서 후처리 방식의 웨이블릿(Wavelet) 알고리즘을 제안하였다. 웨이블릿은 입력 영상의 종류에 따라 역치(Threshold) 값을 설정해 주어야 하는 단점이 있기 때문에 본 연구에서는 역치 값을 실험적으로 제안하였고 화질 평가도 하였다. 실험결과, 복부 CT 영상의 최적 역치 값은 50으로 계산되었다. 실험영상 1의 경우 49%, 실험 영상 2의 경우 29% 노이즈가 개선되었고, 대조도도 크게 상승 하였다. 본 연구 결과를 저선량 복부 CT 영상을 획득 후 후처리 방법으로 적용한다면, 화질을 개선시킬 수 있어 질병 판독에 도움을 줄 것으로 판단한다.

18F-FDG PET/CT 검사에서 정량분석에 관한 CT와 MRI 조영제의 효과 (The Effectiveness of CT and MRI Contrast Agent for SUV in 18F-FDG PET/CT Scanning)

  • 차상영;조용귀;이용기;송종남;최남길
    • 한국방사선학회논문지
    • /
    • 제10권4호
    • /
    • pp.255-261
    • /
    • 2016
  • PET/CT 촬영에서 정량분석에 영향을 주는 다양한 인자 중 현재 상품화된 CT 조영제와 MRI 조영제의 종류별 각 성분의 특성에 따른 SUV의 변화를 비교 분석하고자 하였다. 실험장비는 Discovery 690 PET/CT(Ge)와 NEMA NU2-1994 PET phantom를 이용하였고, 팬텀에 증류수 2/3를 채워 넣은 후 방사성동위원소(18F-FDG 37 MBq)와 각각의 CT와 MRI 조영제를 순차적으로 주입하여 팬텀을 고르게 교반하고 다시 증류수를 가득 채운 후 기포가 생기지 않게 하였다. 방출스캔은 FDG 또는 FDG와 혼합한 조영제를 넣고 40분에 15분 동안 스캔하였으며, 투과스캔은 CT로 관전압 120 kVp, 관전류 40 mA, 회전시간 0.5 sec, 단면두께 3.27 mm, DFOV 30 cm의 조건으로 스캔하였다. 분석방법으로 정량분석은 각각 10, 15, 20, 25, 30번째 slice에서 region of interest (ROI)를 설정하여 각각 SUVmean, SUVmax를 구하였다. 결과적으로 순수 FDG 영상과 비교에서 MRI 조영제를 혼합한 3종류의 영상 모두에서 SUVmean가 높게 측정되었으나 통계적 유의성은 없었고, SUVmax 에서는 유의한 결과를 얻었다. 또한 4종류의 CT 조영제 영상은 SUVmean, SUVmax 모두 유의한 결과를 얻었다. PET/CT는 영상의 정확도를 위해 감쇠 보정은 다양한 방법으로 시행되고 있지만 CT와 MRI 조영제는 감쇠보정 시 영상의 왜곡에 의한 진단적 가치를 저하시킬 수 있다. 이러한 이유로 진료 당일 여러 종류의 검사를 시행하기 전 반드시 선행되어야 할 검사를 선별하여 서로 영향을 주지 않도록 함으로서 고객에게 차별화된 양질의 의료서비스를 제공해야 한다.

융합영상(Fusion image)에서 움직임을 줄이기 위한 보정기구의 개발 (Development of Supplemental Equipment to Reduce Movement During Fusion Image Acquisition)

  • 조용귀;표성재;김봉수;신채호;조진우;김창호
    • 핵의학기술
    • /
    • 제17권2호
    • /
    • pp.84-89
    • /
    • 2013
  • PET-CT (Positron Emission Tomography-Computed Tomography)의 융합영상(Fusion image)에서 긴 영상 획득 시간에 의한 환자의 움직임은 융합영상에서 부적합한 결과로 나타나 영상의 질과 진단에 큰 영향을 준다. 의료장비 회사에서 제공하는 팔 지지대는 환자 자세에서의 편의성과 안전성을 고려하지 않아 PET/CT를 검사하는 동안 팔과 머리의 움직임 때문에 뇌기저부의 영상 결손이 생기고 머리의 좌우, 상하 움직임으로 인하여 재촬영이 빈번하다. 이에 우리는 두경부와 팔의 움직임을 최소화할 수 있는 환자보정기구를 개발하여 PET/CT 촬영 시 환자에게 편의성과 안전성을 제공하고 환자의 움직임으로 인한 재촬영을 줄이고자 한다. 2012년 6월부터 7월까지 PET Torso 검사를 위해 핵의학과에 내원하는 환자들 중 움직임에 불편함이 전혀 없는 환자 20명과 어깨 통증으로 팔을 올리기가 불편한 환자 20명을 대상으로 Patient Holding System (PHS)와 팔의 경사도($25^{\circ}$, $27^{\circ}$, $29^{\circ}$, $31^{\circ}$, $33^{\circ}$, $35^{\circ}$)를 변화시켜 가장 편안한 자세와 경사도를 선정 하였다. 또한 지지대 재질의 투과성에 대하여 유관업체의 검증을 하였고, 환자의 머리와 팔을 밴드(벨크로 형태)로 고정하여 이에 대한 편의성을 질의하였다. 그리고 움직임에 의한 재촬영 빈도를 알아보기 위해 2012년 1월부터 12월까지 PET Torso를 시행한 환자들 중 환자보정기구 사용 전/후 재촬영 여부를 분석하였다. 움직임에 불편이 전혀 없는 환자에서는 18명이 PHS와 팔의 각도가 $29^{\circ}$에서 가장 편안함을 느낀다고 답하였으며, 2명은 각각 $27^{\circ}$, $31^{\circ}$이라고 답하였다. 어깨 통증을 느끼는 환자에서는 15명이 $31^{\circ}$에서 가장 편안함을 느낀다고 답하였고, $33^{\circ}$에서 2명, $35^{\circ}$에서 3명이었다. 이를 위해 손잡이 부분이 상, 하 움직임이 가능하도록 제작하였다. 환자보정기구 재질의 투과성은 검증된 상태이며, 환자보정기구 자체의 움직임을 방지하기 위하여 PHS와 보정기구를 밴드(벨크로 형태)로 고정시켰다. 두경부의 움직임을 최소화할 수 있는 홈을 만들고 머리를 고정할 수 있게 고정밴드를 부착 하였고, 손목 및 전완과 상완의 움직임을 제한할 수 있는 고정밴드를 부착하여 팔의 흔들림으로 인한 움직임을 최소화 하였다. PET Torso 촬영 시 움직임에 의한 재촬영 빈도는 환자고정기구 사용 전 10.56% (191건/1,808명), 사용 후 2.77% (48 건/1,732명)로 7.79%의 발생 빈도를 줄일 수 있었다. 최근 의료 환경의 변화와 혁신으로 고가의 영상검사가 늘어남에 따라 고객이 요구하는 차별화된 서비스 제공은 필수적이다. 따라서 PET/CT를 검사하는 동안 환자의 편안함과 안전성을 확보하기 위해 인체공학적인 환자보정기구를 제공하여야 한다. 따라서 본 연구를 통해 PET Torso 검사 시 환자의 체형과 상황에 따라 인체공학적 경사도를 상, 하 조절할 수 있는 환자보정기구를 제작하였으며, 팔의 움직임에 의한 뇌기저부의 영상결손을 줄이고 머리의 움직임으로 인한 재촬영을 줄일 수 있었다.

  • PDF

양전자방출단층촬영 시 갈색지방조직 활성화에 영향을 미치는 요인 분석 (Factors Influencing the Activation of Brown Adipose Tissue in 18F-FDG PET/CT in National Cancer Center)

  • 유연욱;이충운;정재훈;김윤철;이동은;박소현;김태성
    • 핵의학기술
    • /
    • 제25권1호
    • /
    • pp.21-28
    • /
    • 2021
  • 갈색지방세포(Brown fat 또는 Brown Adipose Tissue, BAT)는 포도당 대사(glucose metabolism)와 비오한성 열생성(non-shivering thermogenesis)을 통하여 열을 발산하여 추위로부터 생명체를 보호한다. BAT의 활성화는 연령, 성별, 체질량지수(BMI) 등의 환자 내적 요인과 기온, 환경 등의 환자외적 요인에 의해 확률적으로 발생한다. 본 연구에서는 후향적, 의무기록 관찰 연구를 진행하여 여러 인자들을 추출하고 통계 분석을 실시하여 BAT 활성화와 여러 인자 간에 관련성을 확인하고자 한다. 2018년 1월부터 2019년 12월까지 2년간 국립암센터에서 PET/CT 검사를 시행한 환자의 의무기록을 수집하여 총 9155명의 환자를 추출하고 중복 검사를 포함한 13442건의 환자데이터를 대상으로 하였다. 환자데이터의 의무기록에서는 BAT 발생여부, 성별, 검사당시 나이, 영상촬영날짜, 검사장소, 주사시간, 키, 체중, 혈당, 진단명이 나오도록 조건을 설정하였다. BAT 활성화가 PET/CT 촬영 시 환경(기온, 검사장소)과 환자의 상태(혈당, BMI, 암의 종류, 성별, 나이)에 따라 영향을 받는지 확인하기 위하여 단변량 로지스틱 회귀분석을 실행한 후, P<0.1인 변수를 선택하여 BAT 활성화에 영향을 주는 다변량 회귀분석 모형을 최종적으로 분석하였다. BAT 활성화는 전체 13442건 중 93건(0.7%)이 발생되었다. 단변수 로지스틱 회귀분석 결과에서 유의한 결과는, 50세 이상인 환자보다 50세 미만인 환자에게서(P<0.001), 여성이 남성에 비해서(P<0.001), 외부기온 14.5도 미만에서(P<0.001), 정상 BMI보다 낮은 BMI에서(P<0.001), 혈당이 100mg/dl 미만에서(P<0.001), 오후 12시 30분 이전에 주사를 맞은 환자에게서(P<0.001) BAT 활성화가 증가하였다. 반면, 정상보다 높은 BMI에서(P<0.001), 폐암진단을 받은 환자에게서(P<0.05) 감소하였다. 다변수 결과에서는, 50세 미만인 환자에게서(P<0.001), 여성에게서(P<0.001), 외부기온 14.5도 미만에서(P<0.001) BAT 활성화가 유의하게 증가하였고, 정상보다 높은 BMI에서(P<0.05) 유의하게 감소하였다. 국립암센터에서 2년간 PET/CT 시행한 환자를 대상으로 BAT 활성화에 영향을 미치는 인자에 대한 후행 연구를 진행하였다. 그 결과, 외부기온 14.5도 미만의 날씨에 PET/CT 검사를 시행했던 50대 미만의 정상 체중 여성에게서 BAT가 유의하게 활성화가 되었음을 확인할 수 있었다. 이 결과를 토대로 해당 인자에 적용된 환자를 사전에 식별할 수 있으며, 앞으로 여러 연구를 통하여 BAT의 활성화를 줄이는 것에 도움이 될 수 있다고 사료된다.