컴퓨터 네비게이션을 이용한 슬관절 전치환술에서 핀 홀에 의한 응력 집중: 유한요소해석 (The Stress Concentration Caused by Pin-hole in Femur after Computer-navigated Total Knee Arthroplasty: A Finite Element Analysis)

  • 박형균;김윤혁;박원만;김경수
    • 대한의용생체공학회:의공학회지
    • /
    • 제29권6호
    • /
    • pp.451-456
    • /
    • 2008
  • Total knee arthroplasty(TKA) using computer-assisted navigation has been increased in order to improve the accuracy of femoral and tibial components implantation. Recently, a few clinical studies have reported on the femoral stress fracture after TKA using computer-assisted navigation. The purpose of this study is to investigate the stress concentration around the femoral pin-hole for different pin-hole diameter, the modes of pin penetration by finite element analysis to understand the effects of pin-hole parameters on femoral stress fracture risk. A three-dimensional finite element model of a male femur was reconstructed from 1 mm thick computed tomography(CT) images. The bone was rigidly fixed to a 25 mm above the distal end and 1500 N of axial compressive force and 12 Nm of axial torsion were applied at the femoral head. For all cases, transcortical pin penetration mode showed the highest stress fracture risk and unicortical pin penetration mode showed the lowest stress concentration. Pin-hole diameter increased the stress concentration, but pin number did not increase the stress dramatically. The results of this study provided a biomechanical guideline for pin-hole fracture risk of the computer navigated TKA.

PET/CT 검사에서 SharpIR 재구성 방법의 평가 (Evaluation of SharpIR Reconstruction Method in PET/CT)

  • 김정열;강천구;박훈희;임한상;이창호
    • 핵의학기술
    • /
    • 제16권1호
    • /
    • pp.12-16
    • /
    • 2012
  • 서론: 종래의 PET 영상 재구성에 있어서 FBP 등에 비해 3차원 반복 재구성 방법이 일반적으로 대체하고 있으며, 이것은 검출기 기하학적 특성과 완벽한 3차원 산란 평가 및 저잡음 randoms 평가 등의 더 진보된 재구성 알고리즘을 제공하고 활용되고 있다. 최근에 SharpIR알고리즘은 3차원 반복 재구성 알고리즘으로 PET 검출기 응답 정보를 통합하여 PET 영상의 잡음을 효과적으로 감소시켜 대조도를 향상 시키기 위한 것으로 알려지고 있다. 본 연구에서는 새로운 반복 시스템 모델인 SharpIR에 대한 성능 평가와 임상에서의 적용 가능성에 대해 알아보고자 한다. 실험재료 및 방법: 검출기 응답에 대한 분해능을 측정하기 위해 유리관(내경 1.1 mm, 두께 0.2 mm)에 $^{18}F$-FDG (250 MBq/mL)을 주입하여 축 방향 시야의 중심과 축 방향으로 5, 10, 15, 20 cm만큼 떨어진 지점에서 획득하였고 VUE point HD와 VUE point HD-SharpIR로 재구성하여 각각의 영상에서 반치폭을 구하였다. 또한 영상품질평가로 image quality phantom (NU2-2001)을 이용하여, 여러 개의 각각 다른 반지름을 가지는 원형구에 cold (직경 28, 37 mm)와 ho (직경 10, 13, 17, 22 mm)부분을 나누어 배경잡음을 주고 영상의 대조도를 평가하였다. 획득된 영상은 VUE point HD와 VUE point HD-SharpIR로 재구성을 하였다. 임상실험에서는 전신검사를 시행받은 환자 중 병소가 있는 환자 10명을 대상으로 VUE point HD와 VUE point HD-SharpIR로 재구성하였다. 이때 iterations을 1~10까지 변경하여 병소 부위와 간 부위에 관심영역을 설정하여 대조도를 평가하였다. 결과: VUE point HD로 재구성한 영상에서는 시야 중심으로부터 축방향 거리 증가와 함께 반치폭이 함께 증가하였지만 VUE point HD-SharpIR로 재구성한 영상에서는 거리가 증가하여도 일정한 반치폭을 나타냈다. 대조도는 팬텀 실험과 임상 실험에서 VUE point HD-SharpIR이 VUE point HD보다 대조도의 향상을 나타냈다. 결론: 검출기 시스템 응답에 대한 더 많은 정보를 포함시킴으로써 SharpIR 알고리즘은 VUE point HD에서 사용되는 기본 모델의 정확성을 향상시켰다. 또한 SharpIR은 VUE point HD보다 각각의 복셀에 관련된 더 많은 측정 위치를 가지는 시스템 모델이기 때문에 더욱 정교한 재구성 모델의 결과를 나타내기 위해 더 많은 반복이 걸린다. 결론적으로 SharpIR은 PET 영상에서 대조도를 향상시켰고 임상에서 적용할 수 있는 최적화된 재구성 조건을 알아보기 위해 종단적 연구를 통해 적용한다면 임상에서 유용하게 사용될 것이다.

  • PDF

호흡동조 정위체부방사선치료에서 Gated Cone-beam CT의 유용성 평가 (Evaluation of usefulness of the Gated Cone-beam CT in Respiratory Gated SBRT)

  • 홍성윤;이충환;박제완;송흥권;윤인하
    • 대한방사선치료학회지
    • /
    • 제34권
    • /
    • pp.61-72
    • /
    • 2022
  • 목 적: 기존의 CBCT(Cone-beam Computed-tomography)는 호흡에 의한 움직임의 영향을 받는 부위에서 장기의 움직임으로 표적용적에 오차가 발생했다. 본 논문의 목적은 호흡동조방사선치료를 시행할 때 오차를 감소시켜주는 Gated CBCT(Gated Cone-beam Computed-Tomography)기능을 이용하여 정확성과 소요시간의 각각 유용성을 평가하고 위상에 따른 적절성에 대해 고찰하고자 한다. 대상 및 방법: Gated CBCT의 유용성을 평가하기 위해 Truebeam STxTM에서 QUASARTM 호흡 움직임 팬텀과 납 표지자 삽입물(lead marker inserts)을 이용하여 전체 위상(Full Phase), 20~80% 위상, 30~70% 위상, 40~60% 위상마다 5회씩 Gated CBCT를 촬영하여 납 표지자의 번짐(Blurring) 길이를 측정하고 투시 촬영(fluoroscopy)의 Trigger mode를 사용하여 최고 위상(Top Phase)에서 구간이 끝나는 지점까지 납 표지자가 움직이는 거리를 5회씩 측정하여 비교하였다. 삼나무 고체 종양 삽입물(Cedar Solid Tumor Inserts)을 이용하여 4차원 전산화단층촬영(4-Dimentional Computed-tomography, 4DCT)을 촬영하여 전체 위상, 20~80% 위상, 30~70% 위상, 40~60% 위상마다 표적 용적을 설정하고 축 방향(S-I방향)으로 5회씩 길이를 측정하였고 동일하게 Gated CBCT를 5회씩 촬영하고 영상의 CT 값(CT number)을 분석하여 표적이 움직인 거리를 측정하여 비교하였다. 결 과: 납 표지자 삽입물을 이용하여 촬영한 Gated CBCT에서 전체 위상은 평균 4.46 cm, 20~80% 위상은 평균 3.11 cm, 30~70% 위상은 평균 1.94 cm, 40~60% 위상은 평균 0.90 cm가 측정되었다. 투시 촬영에서 납 표지자의 축방향 움직임 거리는 평균 4.38 cm였고 Trigger mode를 이용하여 최고 위상부터 Beam off 구간까지의 거리는 20~80% 위상은 평균 3.342 cm, 30~70% 위상은 평균 2.04 cm, 40~60% 위상은 평균 0.84 cm가 측정되었다. 두 결과를 비교하였을 때 전체 위상은 0.08 cm, 20~80% 위상은 0.23 cm, 30~70% 위상은 0.10 cm, 40~60% 위상은 0.07 cm의 차이가 확인되었다. 삼나무 고체 종양 삽입물을 이용하여 촬영한 4차원 전산화단층촬영 영상으로 윤곽 묘사(contouring)한 내부표적용적(Internal Target Volume, ITV)과 치료계획용적(Planning Target Volume, PTV) 윤곽의 길이는 전체 위상에서 6.40 cm, 7.40 cm, 20~80% 위상에서 4.96 cm, 5.96 cm, 30~70% 위상에서 4.42 cm, 5.42 cm, 40~60% 위상에서 2.95 cm, 3.95 cm가 측정되었고 촬영한 Gated CBCT에서 Full 위상은 평균 6.35 cm, 20~80% 위상은 평균 5.25 cm, 30~70% 위상은 평균 4.04 cm, 40~60% 위상은 평균 3.08 cm가 측정되었다. 두 결과를 비교하였을 때 내부표적용적에서 ±8.5% 이내의 오차로 일치하는 것을 확인하였다. 결 론: 기존의 CBCT는 호흡에 의한 움직임의 영향을 받는 부위에서 장기의 움직임으로 오차가 발생하는 문제가 있었지만 본 연구를 통해서 Gated CBCT를 이용하여 설정한 위상의 표적 용적과 비슷한 영상을 얻어 정확한 영상유도를 시행하여 유용성을 확인하였다. 하지만 설정한 위상이 줄어들수록 영상 촬영소요시간이 길어진다. 따라서, 촬영소요시간과 위상의 오차를 고려했을 때 30~70% 위상 이상의 넓은 위상을 사용하는 호흡동조 정위체부방사선치료 환자에게 적용하는 것이 적절하다고 생각한다.

RPM SystemTM을 이용한 호흡 관찰의 유용성 평가 (The variability of tumor motion and respiration pattern in Stereotactic Body RadioTherapy(SBRT) for Lung cancer patients)

  • 박현준;배선명;백금문;강태영;서동린
    • 대한방사선치료학회지
    • /
    • 제28권1호
    • /
    • pp.17-25
    • /
    • 2016
  • 목 적 : 정위적체부방사선치료(Stereotactic Body Radiation Therapy, SBRT)를 시행하는 폐암환자의 호흡 변화에 따른 종양 움직임의 재현성을 비교 분석하고, 치료 중 환자 호흡의 안정도를 확인하여 호흡 신호 확인 과정의 유용성을 평가하고자 한다. 대상 및 방법 : 호흡연동방사선치료(Respiratory Gated Radiation Therapy, RGRT)를 실시한 30명과 RGRT를 시행하지 않는 30명을 그룹1, 2로 정하고, 4-Dimensional Computed Tomography (4-DCT), Cone-Beam CT (CBCT), 투시 영상에서 측정한 종양의 움직임 차이를 비교하였다. 그룹2를 대상으로 치료 중 호흡의 안정도를 확인하기 위해서 Real-time Position Management (RPM) System (version 1.7.5, Varian, USA)을 이용하여 호흡 신호의 기준 구간을 설정하고 치료 중 환자의 호흡이 정해진 구간에서 벗어난 횟수를 측정하였다. 결 과 : 4DCT에서 측정한 평균 움직임과 CBCT에서 평균 움직임의 차이가 그룹1은 전 후 방향, 축 방향, 측 방향 각각 1.0 mm, 1.1 mm, 1.9 mm, 그룹2는 0.3 mm, 0.9 mm, 0.4 mm로 확인되었다. 4DCT와 투시 영상의 축 방향에 대한 평균 움직임 차이는 그룹1에서 0.6 mm, 그룹2에서는 2.3 mm였고, CBCT와 투시 영상의 축 방향에 대한 차이는 그룹1에서 1.7 mm, 그룹2에서 1.4 mm의 차이를 보였다. 그룹2에서 1회 치료(15Gy)를 시행하는 동안 호흡 기준을 벗어나지 않고 치료가 시행된 경우는 대상 환자 30명의 총 120회 중 32회였고, 가장 많이 벗어난 환자는 1회 치료 시 최대 108번 설정 기준을 벗어난 것으로 확인되었다. 결 론 : 전체 대상 환자의 종양 움직임은 각각의 영상에서 평균적으로 5 mm 미만의 차이를 보였지만 특정 환자의 경우 13 mm이상의 차이가 있었고, RGRT를 적용하지 않은 환자들의 치료 중 호흡이 불안정한 것을 확인할 수 있었다. 본 연구를 통하여 고 선량이 전달되는 폐암 환자의 SBRT 시 RGRT를 적용하지 않는 환자에 대해서도 종양 움직임을 확인하고 RPM system 을 이용한 치료 중 호흡 관찰을 실시한다면, 치료 중 계획된 선량 전달의 정확성을 높일 수 있을 것으로 사료된다.

  • PDF

폐암 환자의 정위적방사선 치료 시 이중 에너지를 이용한 치료 방법의 유용성 평가 (Evaluation of useful treatment which uses dual-energy when curing lung-cancer patient with stereotactic body radiation therapy)

  • 장형준;이영규;김영재;박영규
    • 대한방사선치료학회지
    • /
    • 제28권2호
    • /
    • pp.87-99
    • /
    • 2016
  • 목 적 : 종양의 위치에 따라 단일에너지를 이용한 치료계획과 이중에너지를 사용하는 치료계획을 정위적방사선 치료에 적용하여 실제 종양에 부여되는 선량의 변화와 종양과 인접한 부분에 위치하는 정상조직의 선량을 비교하여 임상적 유용성을 평가하고자 한다. 대상 및 방법 : 총 10명의 환자 CT 영상을 획득한 후 각각 단일에너지, 이중 에너지에 대한 체적변조회전치료 기법에 대한 치료 계획을 수립하였다. 종양 측 변화 요인을 분석하기 위하여 조형계수(CI)와 균질성 지수(HI), 최대 선량을 각각 계산했으며, 정상 조직에 대한 선량 분포를 비교하기 위하여 $V_{10}$$V_5$, 종양에 가장 근접한 첫 번째 ~ 네 번째 갈비뼈($1^{st}{\sim}4^{th}$ Rib), 척수(Spinal Cord), 식도(Esophagus)와 기관(Trachea)를 선정하였다. 또한 계획한 선량 분포가 실제 전달되는 정확성을 확인하기 위하여 2차원 이온전리함 배열을 이용하여 선량 측정을 시행하였다. 결 과 : 종양 측 인자의 경우 조형계수와 균질성 지수는 두 에너지를 사용했을 경우가 1에 가까운 값을 나타냈다. 최대 선량의 경우 앞쪽 흉벽은 약 2%, 등쪽 종양의 경우는 동등한 값을 나타냈다. 정상 조직의 경우 앞쪽 흉벽 종양은 인접한 갈비뼈에서 두 에너지를 동시에 사용한 경우 각각 4%, 5% 감소하였고, 기관지의 경우 11%, 17% 감소하였다. 폐의 선량 분포의 경우 $V_{10}$의 경우 1.5%, $V_5$의 경우 1%로 감소함을 나타냈다. 뒤쪽 흉벽의 경우 종양에 인접한 갈비뼈는 두 에너지를 이용한 경우에서 각각 6%, 1%, 4%, 12% 감소하였고, 폐의 선량 분포에서는 $V_{10}$ 3%, $V_5$ 3.1% 감소됨을 나타내었다. 선량 측정의 경우 모든 에너지에서 감마지표 3mm/3%의 결과에 부합하였다. 결 론 : 단일 에너지를 이용한 치료 계획 보다 두 에너지를 동시에 사용하는 경우가 표재성 종양에 대해 보다 유용하게 적용될 수 있을 것으로 사료된다.

  • PDF

용적세기조절회전치료 치료계획 확인에 사용되는 MapPHAN의 유용성 평가 (Evaluation of the Usefulness of MapPHAN for the Verification of Volumetric Modulated Arc Therapy Planning)

  • 우헌;박장필;민제순;이제희;유숙현
    • 대한방사선치료학회지
    • /
    • 제25권2호
    • /
    • pp.115-121
    • /
    • 2013
  • 목 적: 최신 선형가속기와 새로운 평가 장비를 도입하게 되어 이를 임상에 적용하기 위한 준비과정 중 몇 가지 문제가 발생하여 유용성을 확인하는 과정을 분석함으로써 앞으로 이 장비를 도입하는 기관에 도움이 되고자 한다. 대상 및 방법: 모든 측정은 TrueBEAM STX (Varian, USA)를 이용하였으며, 전산화치료계획장비(Eclipse ver 10.0.39, Varian, USA)를 이용하여 각 에너지 별, 조사조건 별 선량분포파일을 산출하였다. MapCHECK 2의 고유의 성능과 오차로 발생 할 수 있는 원인에 대하여 측정 및 분석하였다. MapCHECK 2의 성능 확인을 위해 6X, 6X-FFF (Flattening Filter Free), 10X, 10X-FFF, 15X의 에너지별로 필드사이즈 $10{\times}10$ cm, gantry $0^{\circ}$, $180^{\circ}$ 방향에서 측정을 하였다. 또한 기존 IGRT couch의 CT값이 volumetric dosimetry에 영향을 주는지 확인을 위해서, CT 넘버 값: -800 (Carbon) & -950 (COUCH안의 공기), -100 & -950을 지정해준 상태에서 6X-FFF, 15X의 에너지별로 필드사이즈 $10{\times}10$ cm, gantry $0^{\circ}$, $180^{\circ}$, $135^{\circ}$, $275^{\circ}$ 방향에서 측정을 하였고, MapPHAN에 할당된 HU 값 확인을 위해 Solid water phantom 3 cm을 위로 얹은 MapCHECK 2와 치료계획용 컴퓨터를 이용해 비교하였고, MapPHAN의 각진 모서리에 의한 측정오류문제, MapPHAN의 gantry 방향 의존성을 알아보기 위해 3가지 방법으로 측정 하였다. 세로로 세운 세팅 상태에서 6X-FFF, 15X를 GANTRY $90^{\circ}$, $270^{\circ}$ 방향에서 각각 측정하고, 가로로 세운 세팅상태에서 에너지 6X-FFF, 15X를 필드사이즈 $10{\times}10$ cm, $90^{\circ}$, $45^{\circ}$, $315^{\circ}$, $270^{\circ}$의 방향에서 각각 측정하였다. 세 번째로 빔의 세기조절을 하지 않은 상태에서 open arc를 조사하였다. 결 과: MapCHECK의 기본 성능을 확인, Couch에 의한 감약 측정, MAP-PHAN에 할당하는 HU값 측정, MapPHAN의 각진 모서리에 대한 계산 정확도 확인을 위한 측정에서 모두 유효한 범위에 들어와 측정오류에 영향을 미치지 않는 것을 확인 할 수 있었다. Gantry 방향의존성 확인하기 위한 3가지 방법 중 첫 번째로 측정기를 세운 상태에서의 값은 Gantry $270^{\circ}$ (상대적 $0^{\circ}$), $90^{\circ}$ (상대적 $180^{\circ}$)에서 6X-FFF, 15X에서 각각 -1.51, 0.83%와 -0.63, -0.22%를 나타내어 AP/PA 방향에 의한 영향이 없음을 나타냈다. 측정기를 가로로 세팅한 상태에서는 Gantry $90^{\circ}$, $270^{\circ}$에서 에너지 6X-FFF 4.37, 2.84%, 15X에서는 -9.63, -13.32%의 차이가 측정되어 gamma pass rate 3%의 값보다 큰 값을 나타내므로 MapPHAN에 의한 측방향 측정값이 유효범위 안에 들지 못하는 것을 확인 할 수 있었다. 마지막 Open Arc에서 6X-FFF, 15X 에너지를 필드사이즈 $10{\times}10$ cm에 $360^{\circ}$ 회전상태에서의 선량분포를 보면 pass rate가 90% 가까이 나오는 것을 확인 할 수 있다. 결 론: 위 결과를 토대로 MapPHAN은 상대등선량분포 감마값 측정에는 적합 하지만, 측방향 빔에 대한 gantry 방향의 의존성 때문에 절대선량은 정확한 측정을 할 수 없는 것으로 판단되어진다. 본 논문에서는 더욱 정확한 치료계획 확인을 위해서 VMAT 같은 회전조사시 측방향에 대한 오차를 줄이고 정확한 절대선량을 측정하기 위해서 MapCHEK 2와 IMF (Isocentric Mounting Fixture)의 조합을 사용하여 gantry 방향 의존성에 의한 영향을 최소화 할 수 있을 것이라 판단된다.

  • PDF

고립성폐결절의 진단시 FDG-PET의 임상적 유용성에 관한 연구 (Diagnostic Efficacy of FDG-PET Imaging in Solitary Pulmonary Nodule)

  • 천은미;김병태;권오정;김호중;정만표;이종헌;한용철;이경수;심영목;김진국;한정호
    • Tuberculosis and Respiratory Diseases
    • /
    • 제43권6호
    • /
    • pp.882-893
    • /
    • 1996
  • 연구배경: 고립성 폐결절의 3분의 1이상이 악성결절로 알려져 있으나 고립성 폐결절로 발견될 때는 상당수에서 치유 가능한 병기이다. 국내는 특성상 결핵종이 많아 고립성 폐결절의 진단에 주의를 요한다. 현재 까지 사용되고 있는 진단수기들로 진단이 되지 않아 때에 따라서는 불필요한 개흉술을 해야되는 경우가 많은 실정이다. 최근 새로운 비침습적 진단수기인 FDG-PET가 악성과 양성의 감별진단에 활발히 사용되고 있다. 방법: 1994년 9월부터 1995년 9월까지 삼성서울병원에 내원한 환자중 6cm 마만의 고립성 폐 결절을 가진 34명의 환자를 대상으로 전향적 연구를 시행하였다. 모든 환자는 단순흉부방사선촬영, 흉부전산화단층촬영 그리고 FDG-PET를 시행한 후 FDG-PET의 결과와 객담세포진 검사 경피적흡인세침술, 기관지경검사와 개흉술 의 조직학적 결과와 비교하여 FDG-PET의 정확도를 비교하였다. PET영상은 SUV 값이 4.0이상이고 시간-방사능 곡선(t ime-activity curve)이 지속적으로 증가하는 경우를 악성으로 판정하였다. 결과: 1) 악성결절($3.1{\pm}1.5cm$, $mean{\pm}SD$)과 양성결절($2.8{\pm}1.0cm$, $mean{\pm}SD$)의 크기에는 의의있는 차이가 없었다(P=0.407). 2) 악성결절의 최대 SUV는 $6.9{\pm}3.7$($mean{\pm}SD$)로써 양성결절의 $2.7{\pm}1.7$($mean{\pm}SD$) 보다 의미있게 높았으며 시간-방사능 곡선은 악성결절에서 지속적인 증가를 보였다(P< 0.05). 3) FDG-PET는 18명의 악성결절중 15명을 악성으로 진단하고 3 례의 위음성을 보였다. 3 례의 위음성은 모두 2cm미만의 비점액성의 세기관지폐포암이었다. 4) FDG- PET는 83% 의 민감도, 100%의 특이도, 100%의 양성예측도와 84%의 음성예측도를 보였다. 결론: 고립성 폐결절에서 FDG-PET는 악성결절과 양성결절의 감별진단에 높은 정확도를 보이는 비침습적 진단수기로써 불필요한 시술로 인한 이환율과 사망율을 줄이고 필요시는 개흉술의 근거를 줄 수 있는 새로운 진단수기 로 사료된다.

  • PDF

직장풍선을 삽입한 전립선암 환자의 수술 후 방사선 치료 시 용적변조와 세기변조방사선치료계획 비교 평가 (Comparison and evaluation of volumetric modulated arc therapy and intensity modulated radiation therapy plans for postoperative radiation therapy of prostate cancer patient using a rectal balloon)

  • 정해윤;석진용;홍주완;장남준;최병돈;박진홍
    • 대한방사선치료학회지
    • /
    • 제27권1호
    • /
    • pp.45-52
    • /
    • 2015
  • 목 적 : 전립선암의 방사선치료는 치료기법에 따라 주요장기와 정상조직의 선량분포에 차이가 나타난다. 본 연구에서는 전립선암 환자의 수술 후 방사선치료 시 직장풍선을 삽입한 환자에게 회전수를 달리한 용적변조회전치료(volumetric modulated arc therapy, VMAT)계획과 세기변조방사선치료(intensity modulated radiation therapy, IMRT)계획을 각각 수립하여 선량분포 특성을 비교하고 치료의 효율성을 평가하고자 한다. 대상 및 방법 : 본원에서 전립선암 수술 후 방사선 치료를 시행한 10명의 환자를 대상으로 하였다. 직장풍선을 삽입한 환자의 CT영상을 3 mm 두께로 획득하고 Eclipse (Ver 11.0, Varian, Palo Alto, USA)를 사용하여 HD120MLC가 장착된 Truebeam STx (Varian, Palo Alto, USA)의 10 MV 에너지를 적용하였다. 환자마다 1 Arc, 2 Arc VMAT계획과 7조사면의 IMRT계획을 수립하였으며 각 치료계획의 선량체적제한과 plan normalization 값은 동일하게 적용하였다. 수립된 세 가지 치료계획을 평가하기위해 PTV의 coverage, conformity index (CI), homogeneity index (HI)를 비교하였고, PTV주변 정상조직의 선량퍼짐정도를 알아보기 위해 50% 등선량체적과 PTV체적의 비($R_{50%}$)를 산출하였다. 결정장기 (organ at risk, OAR)에서는 직장의 $D_{25%}$와 방광의 $D_{mean}$을 비교하였고 치료의 효율성을 평가하기 위해서 총 MU와 조사시간을 측정하였으며, 각 평가항목별 결과는 환자 10명의 평균값으로 비교분석하였다. 추가적으로 선량전달 정확도를 검증하기 위해 EPID를 이용한 portal dosimetry를 진행하였다. 결 과 : 각 치료계획에서 나타난 PTV coverage와 HI의 차이는 크지 않았지만 CI는 1A-VMAT, 2A-VMAT, 7F-IMRT에서 각각 1.036, 1.035, 1.230으로 VMAT에 비해 7F-IMRT가 높았고(p=0.00), $R_{50%}$는 3.083, 3.054, 3.991로 2A-VMAT이 제일 낮았고 7F-IMRT에서 가장 높게 나타났다(p=0.00). 치료계획에 따른 직장의 $D_{25%}$는 VMAT에서 비슷했지만 7F-IMRT가 약 7% 높게 나타났고(p=0.02), 방광의 $D_{mean}$은 큰 차이가 없었다(P>0.05). 총 MU는 1A-VMAT, 2A-VMAT, 7F-IMRT에서 각각 494.7, 479.7, 757.9로 7F-IMRT가 가장 많았고(p=0.00), 조사시간은 65.2초, 133.1초, 145.5초로 1A-VMAT이 확연히 짧았다(p=0.00). portal dosimetry 검증에서는 모든 치료계획에서 99.5% 이상의 gamma pass rate(2 mm, 2%)을 보였다(P=0.00). 결 론 : 본 연구결과 직장풍선을 삽입한 전립선암 환자의 수술 후 방사선치료 시, 치료기법에 따른 PTV coverage의 차이는 크지 않았지만 1A, 2A-VMAT이 7F-IMRT에 비해 정상조직과 직장선량을 낮추는데 효과적이었다. VMAT중에서는 $R_{50%}$와 MU가 2A-VMAT에서 다소 낮았지만 조사시간이 짧은 1A-VMAT이 치료에 더 효율적이며 환자의 치료 중 움직임 또한 줄일 수 있을 것으로 사료된다.

  • PDF

비소세포폐암의 림프절 병기 결정에서 Coincidence PET의 역할 (The Role of Camera-Based Coincidence Positron Emission Tomography in Nodal Staging of Non-Small Cell Lung Cancer)

  • 이선민;최영화;정성철;오윤정;박광주;황성철;이이형;박찬희;한명호
    • Tuberculosis and Respiratory Diseases
    • /
    • 제47권5호
    • /
    • pp.642-649
    • /
    • 1999
  • 연구배경: 비소세포폐암의 림프절의 병기 결정은 치료 및 예후 결정에 매우 중요하나 정확한 병기 결정에는 많은 어려움이 있다. 야에 저자들은 최근에 개발된 CoDe PET의 림프절 병기 결정에 대한 유용성을 알아보고자 하였다. 방 법: 1998년 2월부터 1999년 6월까지 아주대학교병원에 내원하여 원발성 비소세포폐암으로 진단되어 치료를 시행하였던 환자 21예를 대상으로 하였다. 수술적 술전 폐암의 병기 결정을 위하여 흉부 전산화단층촬영, 복부 초음파검사, 전신 골주사 촬영, CoDe PET를 시행하였다. 대상 환자들의 수술후 병리학적 병기를 기준으로 하여서 CoDe PET로 결정된 림프절 병기의 민감도, 특이도, 양성 예측도, 음성 예측도, 정확도를 분석하였다. 결 과: 21예의 비소세포폐암중 20예에서 원발 종괴에 $^{18}FDG$가 섭취되었으며 위음성이 1예가 있었다. 림프절 병기에 있어 전체 21예중 13예에서는 병리학적 병기와 일치하였다. 병리학적 N0는 14예이었으며 CoDe PET의 N0에 대한 특이도는 64.3%이었다. N1 림프절에 대한 민감도는 83.3%, 특이도는 73.3%, 양성 예측도는 55.6%, 음성 예측도는 91.7%, 정확도는 76.2%이였다. N2 림프절에 대한 민감도는 60.0%, 특이도는 87.5%, 양성 예측도는 60.0%, 음성 예측도는 87.5%, 정확도는 90.0%이었다. 병리학적으로 그 크기가 측정된 림프절 29개중 암세포의 침윤이 있었던 림프절은 6개이었으며 이중 3개의 림프절은 CoDe PET에 국소 섭취로 나타났다. 위음성으로 나타난 3개의 림프절은 그 크기가 모두 1cm 이하였으며, 양성으로 나타난 림프절의 크기는 각각 1.1cm, 1.0cm, 0.5cm이었다. 크기가 1cm 이상이나 암세포의 침윤이 없었던 12개의 림프절중 1예에서만 위양성으로 나타났다. 5예에서는 위양성 소견을 보였는데 이중 1예는 폐결핵에 의한 육이종을 관찰할 수 있었으며, 1예는 pneumoconiosis, 1예는 anthracosis이었다. 결 론: CoDe PET는 크기가 1.5cm 이상의 림프절에 대한 음성 예측도가 비교적 높기 때문에 N3 림프절의 확대가 있는 비소세포폐암에서 CoDe PET를 시행하여 국소 섭취가 없는 경우에는 수술적 치료를 고려해 볼 수 있으리라 생각된다. 또한 CoDe PET는 아직 개발 단계에 있어서 향후 보다 더 발전된 영상을 얻을 수 있을 것으로 기대된다.

  • PDF

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF