• 제목/요약/키워드: CT image

검색결과 1,600건 처리시간 0.033초

Quantitative Evaluation of Patient Positioning Error Using CBCT 3D Gamma Density Analysis in Radiotherapy

  • Lee, Soon Sung;Min, Chul Kee;Cho, Gyu Suk;Han, Soorim;Kim, Kum Bae;Jung, Haijo;Choi, Sang Hyoun
    • 한국의학물리학회지:의학물리
    • /
    • 제28권4호
    • /
    • pp.149-155
    • /
    • 2017
  • Radiotherapy patients should maintain their treatment position as patient setup is very important for accurate treatment. In this study, we evaluated patient setup error quantitatively according to Cone-Beam Computed Tomography (CBCT) Gamma Density Analysis using Mobius CBCT. The adjusted setup error to the $QUASAR^{TM}$ phantom was moved artificially in the superior and lateral direction, and then we acquired the CBCT image according to the phantom setup error. To analyze the treatment setup error quantitatively, we compared values suggested in the CBCT system with the Mobius CBCT. This allowed us to evaluate the setup error using CBCT Gamma Density Analysis by comparing the planning CT with the CBCT. In addition, we acquired the 3D-gamma density passing rate according to the gamma density criteria and phantom setup error. When the movement was adjusted to only the phantom body or 3 cm diameter target inserted in the phantom, the CBCT system had a difference of approximately 1 mm, while Mobius CBCT had a difference of under 0.5 mm compared to the real setup error. When the phantom body and target moved 20 mm in the Mobius CBCT, there are 17.9 mm and 13.5 mm differences in the lateral and superior directions, respectively. The CBCT gamma density passing rate was reduced according to the increase in setup error, and the gamma density criteria of 0.1 g/cc/3 mm has 10% lower passing rate than the other density criteria. Mobius CBCT had a 2 mm setup error compared with the actual setup error. However, the difference was greater than 10 mm when the phantom body moved 20 mm with the target. Therefore, we should pay close attention when the patient's anatomy changes.

Missed Skeletal Trauma Detected by Whole Body Bone Scan in Patients with Traumatic Brain Injury

  • Seo, Yongsik;Whang, Kum;Pyen, Jinsu;Choi, Jongwook;Kim, Joneyeon;Oh, Jiwoong
    • Journal of Korean Neurosurgical Society
    • /
    • 제63권5호
    • /
    • pp.649-656
    • /
    • 2020
  • Objective : Unclear mental state is one of the major factors contributing to diagnostic failure of occult skeletal trauma in patients with traumatic brain injury (TBI). The aim of this study was to evaluate the overlooked co-occurring skeletal trauma through whole body bone scan (WBBS) in TBI. Methods : A retrospective study of 547 TBI patients admitted between 2015 and 2017 was performed to investigate their cooccurring skeletal injuries detected by WBBS. The patients were divided into three groups based on the timing of suspecting skeletal trauma confirmed : 1) before WBBS (pre-WBBS); 2) after the routine WBBS (post-WBBS) with good mental state and no initial musculoskeletal complaints; and 3) after the routine WBBS with poor mental state (poor MS). The skeletal trauma detected by WBBS was classified into six skeletal categories : spine, upper and lower extremities, pelvis, chest wall, and clavicles. The skeletal injuries identified by WBBS were confirmed to be simple contusion or fractures by other imaging modalities such as X-ray or computed tomography (CT) scans. Of the six categorizations of skeletal trauma detected as hot uptake lesions in WBBS, the lesions of spine, upper and lower extremities were further statistically analyzed to calculate the incidence rates of actual fractures (AF) and actual surgery (AS) cases over the total number of hot uptake lesions in WBBS. Results : Of 547 patients with TBI, 112 patients (20.4 %) were presented with TBI alone. Four hundred and thirty-five patients with TBI had co-occurring skeletal injuries confirmed by WBBS. The incidences were as follows : chest wall (27.4%), spine (22.9%), lower extremities (20.2%), upper extremities (13.5%), pelvis (9.4%), and clavicles (6.3%). It is notable that relatively larger number of positive hot uptakes were observed in the groups of post-WBBS and poor MS. The percentage of post-WBBS group over the total hot uptake lesions in upper and lower extremities, and spines were 51.0%, 43.8%, and 41.7%, respectively, while their percentages of AS were 2.73%, 1.1%, and 0%, respectively. The percentages of poor MS group in the upper and lower extremities, and spines were 10.4%, 17.4%, and 7.8%, respectively, while their percentages of AS were 26.7%, 14.2%, and 11.1%, respectively. There was a statistical difference in the percentage of AS between the groups of post-WBBS and poor MS (p=0.000). Conclusion : WBBS is a potential diagnostic tool in understanding the skeletal conditions of patients with head injuries which may be undetected during the initial assessment.

구강 악안면 영역의 암종 진단에 있어서 $[^{18}F]$-Fluorodeoxyglucose를 이용한 양전자방출 단층촬영의 임상적 연구 (CLINICAL STUDY OF POSITRON EMISSION TOMOGRAPHY WITH $[^{18}F]$-FLUORODEOXYGLUCOSE IN MAXILLOFACIAL TUMOR DIAGNOSIS)

  • 김재환;김경욱;김용각
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제26권5호
    • /
    • pp.462-469
    • /
    • 2000
  • Positron Emission Tomography(PET) is a new diagnostic method that can create functional images of the distribution of positron emitting radionuclides, which when administered intravenously in the body, makes possible anatomical and functional analysis by quantity of biochemical and physiological process. After genetic and biochemical changes in initial stage, malignant tumor undergoes functional changes before undergoing anatomical changes. So, early diagnosis of malignant tumors by functional analysis with PET can be achieved, replacing traditional anatomical analysis, such as computed tomography(CT) and magnetic resonance image(MRI), etc. Similarly, PET can identify malignant tumor without confusion with scar and fibrosis in follow up check. In the Korea Cancer Center Hospital(KCCH) from October 1997 to September 1999, clinical study was performed in 79 cases that underwent 89 times PET evaluation with [18F]-Fluorodeoxyglucose for diagnosis of oral and maxillofacial tumors, and the data was analysed by Bayesian $2{\times}2$ Classification Table. The results were as follows : Evaluation for initial diagnosis with FDG-PET (P<0.005) 1. Agreement rate or accuracy rate is 88.9%. 2. Sensitivity is 95.2%, and specificity 66.7%. 3. Positive predictive rate is 90.9%, and negative predictive rate 80.0%. 4. In consideration of tumor stage, diagnostic rate in less than stage II was 90% and in greater than stage III 100%. 5. In consideration of tumor size, diagnostic rate in less than T2 was 92.3% and in greater than T3 100%. After primary treatment, evaluation for follow up check with FDG-PET (P < 0.001) 1. Agreement rate or accuracy rate is 85.4%. 2. Sensitivity is 87.5%, and specificity 82.4%. 3. Positive predictive rate is 87.5%, and negative predictive rate 82.4%. 4. In 24 recurred cases, 6 had distant metastasis, and 5 of them were diagnosed with FDG-PET, resulting in diagnostic rate of FDG-PET of 83.3%. From the above results, Positron Emission Tomography with [18F]- Fluorodeoxyglucose appears to be more sensitive and accurate for detecting the presence of oral and maxillofacial tumors, and has various clinical applications such as early diagnosis of tumor in initial and follow up check and detection of distant metastasis.

  • PDF

다중검출기 컴퓨터 단층 영상 분석을 이용한 Resident's ridge의 형태학적 연구 (Geometry of Resident's ridge with Multidetector-Row Computed Tomograph Image)

  • 노정호;민병현;박정욱;안병문
    • 대한관절경학회지
    • /
    • 제12권1호
    • /
    • pp.40-44
    • /
    • 2008
  • 목적: 전방십자인대 재건술시 흔히 관찰하게 되는 Resident's ridge의 실제 형태학적 위치 및 모양을 알아보고자 한다. 대상 및 방법: 2007년 1월부터 2007년 8월까지 본원에서 시행한 48례의 정상 대퇴골 원위부를 촬영한 MD CT(Multidetector-Row Computed Tomography) 영상을 분석하였다. 과간절흔의 외측벽에서 1 mm 이상의 높이 변화를 보이는 경우를 Resident's ridge로 정의 하였다. $Lucion^{(R)}$ 프로그램을 이용하여 3차원 재구성한 영상을 통해 과간절흔의 전후방 길이, resident's ridge의 길이, 높이, 과간절흔의 후방 피질골로부터의 거리를 측정하였다. 결과: 환자의 평균 연령은 $59{\pm}16$세였으며 남성이 16례, 여성이 32례 이었다. Resident's ridge가 존재 하지 않았던 경우는 9례 이었으며 과간 절흔의 전후방 길이는 $25.4{\pm}3.5$ mm, Resident's ridge 의 길이와 높이의 평균값은 각각 $8.2{\pm}2.6,\;3.5{\pm}1.5$ mm 이었으며 Resident's ridge의 후방 피질골로부터의 거리는 $7.6{\pm}2.6$ mm 이었다. 결론: Resident's ridge는 많은 예에서 존재하며 뚜렷한 길이와 높이가 있기 때문에 전방십자인대 재건술시 주요한 landmark로 사용할 수 있다.

  • PDF

치과용 단층촬영을 이용한 Stainless-Steel File과 MFile-System® 전동식 기구의 근관 성형 능력에 대한 비교 연구 (A Comparison of Stainless-Steel File and MFile-System® Ni-Ti Rotary Instrument in Canal Preparation using Dental Computed Tomography)

  • 서동진;윤미란;이린;유미경
    • 구강회복응용과학지
    • /
    • 제22권2호
    • /
    • pp.173-180
    • /
    • 2006
  • Objectives The aim of this study is to compare the quality of root canal preparation completed using MFile-$System^{(R)}$ instrument ( Komet, Gebr.Brsaseler, Germany) and conventional stainless steel file in the canals of Maxillary molar teeth that had a canal curvature between $25^{\circ}$ or more Materials & Methods Buccal canals of 24 first and second maxillary molar teeth, extracted for periodontal and prosthetic reasons were used. Tissue fragments and calcified debris were removed from teeth by scaling and the teeth were stored in 10% formalin solution for 24 hour. Then, teeth were stored in saline until used. To be included the roots had to have completed formed apices and angle of curvature ranging between $25^{\circ}$ or more according to the criteria described by Schneider(1971). Palatal and Second mesiobuccal canals were not included. Teeth were embedded into transparent acrylic. The teeth were randomly divided into two experimental groups. All teeth were scanned by Dental CT (PSR9000N, Asahi, Japan) to determine the root canal shape before instrumentation. Image slices were prepared from the apical end point to the pulp chamber. The first two sections were 2 mm from the apical end of root and 2 mm below the orifice. Further section was recorded, dividing the distance between the sections of apical and coronal levels into two equal lengths. 12 teeth were instrumented using stainless steel fileand another 12 teeth were instrumented using MFile-$System^{(R)}$. Following the completion of the instrumentation, the teeth were again scanned and compared with the cross sectional images taken prior to canal preparation. Amount of transportation and centering ability was assessed. Student's t-test was used for statistical analysis. Result Less transportation occurred with MFile-$System^{(R)}$ rotary instrumentation than stainless steel instrument. MFile-$System^{(R)}$ had better centering ability than stainless steel instrument. Conclusion MFile-$System^{(R)}$ rotary instrumentation transported canals less and had good centering ability.

다양한 생체고분자로 코팅된 Paclitaxel Eluting Stent의 약물함량과 세포독성 연구 (A Study of Drug Content and Cell Cytotoxicity of Paclitaxel-eluting Stents Coated with Various Biopolymer)

  • 김동곤;신일균;김한기;김성현;이주호;기병윤;나재운;서태석;김상호
    • 한국의학물리학회지:의학물리
    • /
    • 제20권3호
    • /
    • pp.125-131
    • /
    • 2009
  • 본 연구는 소화기영역에서의 재협착을 방지하기 위하여 인간의 혈관 평활근 세포의 증식과 이동을 억제하며 신생내막의 형성을 억제하는 특성을 갖는 파클리탁셀(paclitaxel)을 스텐트 표면에 PVAc, PLGA, Silicone rubber 등 다양한 생체고분자로 코팅하여 paclitaxel eluting stent (PES)을 제조하고 그 특성을 분석하였다. 제조된 PES는 코팅용액의 농도가 증가할수록 그리고 코팅고분자의 분자량이 증가할수록 약물함량은 증가 되었고, bare 스텐트보다 커버드(covered) 스텐트의 표면적이 넓기 때문에 약물함량이 약 3배 정도 많음을 알 수 있었다. $^1H-NMR$ 결과에서 스텐트 표면에 파클리탁셀의 코팅과 약물의 변형이 없었음을 알 수 있었고, Silicone rubber을 제외한 다른 생체고분자는 스텐트 표면에 약물이 고르게 코팅되었음을 SEM image로부터 알 수 있었다. 그리고 in vitro에서 PES의 항암활성은 생분해성 고분자이고 분자량이 작은 PLGA 502H가 가장 높게 나타났으며, 분자량이 높을수록 낮은 항암활성을 나타냈다. 이상의 결과로부터 코팅고분자의 종류, 분자량 그리고 코팅용액의 농도를 변화시켜 약물함량을 증가시키고 약물방출을 조절할 수 있는 PES를 성공적으로 제조하였다.

  • PDF

Demineralized Bone Matrix (DBM) as a Bone Void Filler in Lumbar Interbody Fusion : A Prospective Pilot Study of Simultaneous DBM and Autologous Bone Grafts

  • Kim, Bum-Joon;Kim, Se-Hoon;Lee, Haebin;Lee, Seung-Hwan;Kim, Won-Hyung;Jin, Sung-Won
    • Journal of Korean Neurosurgical Society
    • /
    • 제60권2호
    • /
    • pp.225-231
    • /
    • 2017
  • Objective : Solid bone fusion is an essential process in spinal stabilization surgery. Recently, as several minimally invasive spinal surgeries have developed, a need of artificial bone substitutes such as demineralized bone matrix (DBM), has arisen. We investigated the in vivo bone growth rate of DBM as a bone void filler compared to a local autologous bone grafts. Methods : From April 2014 to August 2015, 20 patients with a one or two-level spinal stenosis were included. A posterior lumbar interbody fusion using two cages and pedicle screw fixation was performed for every patient, and each cage was packed with autologous local bone and DBM. Clinical outcomes were assessed using the Numeric Rating Scale (NRS) of leg pain and back pain and the Korean Oswestry Disability Index (K-ODI). Clinical outcome parameters and range of motion (ROM) of the operated level were collected preoperatively and at 3 months, 6 months, and 1 year postoperatively. Computed tomography was performed 1 year after fusion surgery and bone growth of the autologous bone grafts and DBM were analyzed by ImageJ software. Results : Eighteen patients completed 1 year of follow-up, including 10 men and 8 women, and the mean age was 56.4 (32-71). The operated level ranged from L3/4 to L5/S1. Eleven patients had single level and 7 patients had two-level repairs. The mean back pain NRS improved from 4.61 to 2.78 (p=0.003) and the leg pain NRS improved from 6.89 to 2.39 (p<0.001). The mean K-ODI score also improved from 27.33 to 13.83 (p<0.001). The ROM decreased below 2.0 degrees at the 3-month assessment, and remained less than 2 degrees through the 1 year postoperative assessment. Every local autologous bone graft and DBM packed cage showed bone bridge formation. On the quantitative analysis of bone growth, the autologous bone grafts showed significantly higher bone growth compared to DBM on both coronal and sagittal images (p<0.001 and p=0.028, respectively). Osteoporotic patients showed less bone growth on sagittal images. Conclusion : Though DBM alone can induce favorable bone bridging in lumbar interbody fusion, it is still inferior to autologous bone grafts. Therefore, DBM is recommended as a bone graft extender rather than bone void filler, particularly in patients with osteoporosis.

The incidence and configuration of the bifid mandibular canal in Koreans by using cone-beam computed tomography

  • Kang, Ju-Han;Lee, Kook-Sun;Oh, Min-Gyu;Choi, Hwa-Young;Lee, Sae-Rom;Oh, Song-Hee;Choi, Yoon-Joo;Kim, Gyu-Tae;Choi, Yong-Suk;Hwang, Eui-Hwan
    • Imaging Science in Dentistry
    • /
    • 제44권1호
    • /
    • pp.53-60
    • /
    • 2014
  • Purpose: This study was performed to investigate the incidence and configuration of the bifid mandibular canal in a Korean population by using cone-beam computed tomography (CBCT) imaging. Materials and Methods: CBCT images of 1933 patients (884 male and 1049 female) were evaluated using PSR-9000N and Alphard-Vega 3030 Dental CT units (Asahi Roentgen Ind. Co., Ltd, Kyoto, Japan). Image analysis was performed by using OnDemand3D software (CyberMed Inc., Seoul, Korea). The bifid mandibular canal was identified and classified into four types, namely, the forward canal, buccolingual canal, dental canal, and retromolar canal. Statistical analysis was performed by using the chi-squared test and one-way analysis of variance (ANOVA). Results: Bifid mandibular canals were observed in 198 (10.2%) of 1933 patients. The most frequently observed type of bifid mandibular canal was the retromolar canal (n=104, rate: 52.5%) without any significant difference among the incidence of each age and gender. The mean diameter of the accessory canal was 1.27 mm (range: 0.27-3.29 mm) without any significant difference among the mean diameter of each type of the bifid mandibular canal. The mean length of the bifid mandibular canals was 14.97mm(range: 2.17-38.8 mm) with only a significant difference between the dental canal and the other types. Conclusion: The bifid mandibular canal is not uncommon in Koreans and has a prevalence of 10.2% as indicated in the present study. It is suggested that a CBCT examination be recommended for detecting a bifid canal.

Three-Dimensional Kinematic Model of the Human Knee Joint during Gait

  • Mun, Joung-Hwan;Seichi Takeuchi
    • 대한의용생체공학회:의공학회지
    • /
    • 제23권3호
    • /
    • pp.171-179
    • /
    • 2002
  • 운동 중에 있는 인체 무릎관절의 기능을 이해하기 위한 기구학적(Kinematic) 분석 과 동역학적(Kinetic) 분석을 행하는데 있어서 관절 표면의 기하학이 주요한 역할을 한다는 것은 잘 알려져 있다. 슬관절은 미끄러짐 (sliding)과 구름 (rolling) 운동을 고려하지 않고는 정확하게 모델 될 수 없다 본 연구에서는 미끄러짐 과 회전 운동 그리고 주요 인대 (ligament)를 고려한 3타원 인체 슬관절 모델을 제시한다 본 연구는. 슬관절의 전형적인측 평면 CT 영상의 확장으로부터 얻어진 두개의 캠 측면도를 이용하여 보다 실제에 가까운 관절의 기하학을 이용한 모델을 제시한다 개발된 모델은 보행 중 인체 슬관절을 통한 힘의 전달경로를 예측하는데 있어서 실험을 기초로 한 이전의 결과보고와 비교하여 볼 때 매우 잘 일치한다 대퇴골와 경골 사이의 접촉 점은 무릎의 굽힘이 진행되는 동안 전방에서 후방으로 이동하는데 이것은 무릎의 굽힘과 폄의 운동에 대한 전방/후방 운동의 커플링을 반영한 것이다. 본 연구에서 개발된 모델에 의하면 일회의 보행 사이클동안 경골 표면에 접촉 점의 전방/후방 이동변위는 바깥쪽 관절구 쪽이 약 16 mm 이고. 안쪽 관절구 쪽이 약 25 mm 이다 또한, 일회의 보행 사이클 동안 대퇴골 의 이동변위는 바깥쪽이 약 7 mm 그리고 안쪽이 약 10 mm 이다. 개발된 모델은, 관절의 퇴화를 진단 하는데 이용할 수 있는 가능성이 기대된다

후족부 관상면 배열 영상에 대한 고안 (Introduction of Hindfoot Coronal Alignment View)

  • 문일봉;전주섭;윤강철;최남길;김승국
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제29권4호
    • /
    • pp.225-228
    • /
    • 2006
  • 목 적: 후족부의 병리학적 상태의 치료와 평가를 위해서는 관상면에서 종골과 경골이 연관된 배열상태의 정확한 평가가 필수적이다. 이전의 방사선학적 검사인 발과 발목의 전후방향, 측방향, 사방향 촬영과 종골 축방향 촬영 등의 X-선 촬영상은 관상면에서 종골과 경골이 연관된 배열상태를 증명하지 못했다. 이에 본 연구에서는 후족부 관상면 배열영상(hindfoot coronal alignment view)을 새롭게 소개하고자 한다. 검사방법 : 1) 양쪽 발을 지탱할 수 있는 방사선투과성의 스탠드형 보조기구를 제작한다. 2) 양측 발은 weight-bearing position이 되게 한다. 3) 각각의 발의 위치는 발의 종축이 보조기구 판과 수직이 되도록 자세를 유지한다. 4) silhouette tracing: 발뒷꿈치 outline과 둘째 발가락이 일직선상으로 지나도록 위치시킨다. 5) 중심 X-선: 발바닥 쪽을 향해 약 $15{\sim}20^{\circ}의 각도로 종골의 뒷쪽을 향해 입사한다. 결 과 : 1) 경골 축과 종골의 내측, 외측 결절의 영상이 함께 표출된다. 2) 종골이 회전되지 않아야 한다. 3) 거퇴관절강(talotibial joint space)이 함께 나타나야 한다. 결 론: CT나 MRI 영상에서도 관상면에서 후족부의 배열상태를 증명할 수 있지만, 환자의 체중이 주어지지 않기 때문에 발의 임상적인 증상을 보여주기에는 충분하지 못했다. 하지만 후족부 관상면 배열영상은 후족부의 inversion, eversion의 자세변화를 보여주고, 경골 원위부와 종골의 varus, valgus deformity의 치료를 위한 평가 자료로 좋은 검사방법이며, 비교적 자연스럽고 편안한 자세로 환자에게 큰 도움을 줄 것으로 사료된다.

  • PDF