• 제목/요약/키워드: CT image

검색결과 1,671건 처리시간 0.031초

개인용 컴퓨터를 이용한 기능 유관성 관상동맥 협착증의 삼차원 심장스펙트 사진과 64채널 전산화 단층 혈관촬영사진과의 융합 (Fusion of 3D Cardiac SPECT and 64-Channel-CT Angiography Using Personal Computer in Functionally Relevant Coronary Artery Stenosis)

  • 박용휘
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제41권3호
    • /
    • pp.252-254
    • /
    • 2007
  • Image fusion is fast catching attention as Wagner pointed out in his 2006 version of the recent progress and development presented at the annual meeting of Society of Nuclear Medicine. Prototypical fusion of bone scan and radiograph was already attempted at in 1961 when Fleming et al. published an article on strontium-85 bone scan. They simply superimposed dot scan on radiograph enabling simultaneous assessment of altered bone metabolism and local bone anatomy. Indeed the parallel reading of images of bone scan and radiography, CT, MRI or ultrasonography has been practiced in nuclear medicine long since. It is fortunate that recent development of computer science and technology along with the availability of refined CT and SPECT machines has permitted us to open a new avenue to digitally produce precise fusion image so that they can readily be read, exchanged and disseminated using internet. Ten years ago fusion was performed using Bresstrahlung SPECT/CT and it is now achievable by PET/CT and SPECT/CT software and SPECT/CT hardware. The merit of image fusion is its feasibility of reliable assessment of morphological and metabolic change. It is now applicable not only to stationary organs such as brain and skeleton but also to moving organs such as the heart, lung and stomach. Recently, we could create useful fusion image of cardiac SPECT and 64-channel CT angiograph. The former provided myocardial metabolic profile and the latter vascular narrowing in two patients with coronary artery stenosis and myocardial ischemia. Arterial stenosis was severe in Case 1 and mild in Case 2.

치료계획시스템에서 전산화단층촬영과 자기공명영상의 영상융합 재현성 및 선량평가 (CT and MRI image fusion reproducibility and dose assessment on Treatment planning system)

  • 안병혁;최재혁;황재웅;박지연;이두현
    • 대한방사선치료학회지
    • /
    • 제29권2호
    • /
    • pp.33-41
    • /
    • 2017
  • 목 적: 종양에는 최대한의 선량을 부여하고 주변의 정상조직에는 최소한의 선량이 조사되도록 부작용을 줄이는 목적으로 방사선 치료기술이 발전함에 따라 다양한 치료계획 및 치료 방법이 개발되고 있다. 방사선 치료 시 CT(Computed tomography)와 MRI(Magnetic resonance imaging)영상의 융합은 종양에 선량을 전달하는데 커다란 역할을 한다. 본 연구의 목적은 치료계획 시 자체 제작한 팬톰을 이용하여 CT와 MRI영상들의 융합을 통해 영상의 재현성 및 유용성을 평가하고 획득한 영상에서 타겟 선량을 비교, 분석해보고자 한다. 대상 및 방법: 자체 제작한 팬톰을 이용하여 CT 촬영을 하고, 자장의 세기가 다른 1.5T 와 3.0T의 MRI 촬영을 하여 영상을 획득한다. CT 촬영을 한 팬톰의 영상과 각기 다른 자장의 세기로 촬영한 팬톰의 MRI영상에서 팬톰 내에 존재하는 작은 홀의 크기 및 용적의 재현성을 비교하고, 임의의 타겟에서 선량 변화를 비교, 분석한다. 결 과: 13개의 작은 홀 직경은 CT 촬영에서 최대 31 mm, 최소 27.54 mm를 나타냈으며, 실제 제작한 것과 비교하여 평균 29.28 mm 1 % 이내로 측정되었다. 1.5T MRI 퓨전 영상에서는 최대 31.65 mm, 최소 24.3 mm를 나타냈으며, 평균 28.8 mm 1 % 이내로 측정되었다. 3.0T MRI 퓨전 영상에서는 최대 30.2 mm, 최소 27.92 mm를 나타냈으며, 평균 29.41 mm 1.3 % 이내로 측정되었다. 타겟의 조사된 선량변화는 CT에서 95.9-102.1 %, CT-1.5T MRI 퓨전영상에서 93.1-101.4 %, CT-3.0T MRI 퓨전영상에서는 96-102 %의 선량변화를 보였다. 결 론: CT 및 MRI는 영상획득 시 다른 알고리즘이 적용된다. 또한 인체의 장기는 각기 다른 밀도를 가지고 있으므로 영상 획득 시 이미지 왜곡이 발생할 수 있다. 이러한 부정확한 영상의 묘사는 타겟의 용적범위 및 선량에 영향을 주기 때문에 정확한 타겟의 용적과 위치는 불필요한 선량이 조사되는 것을 방지하며, 치료계획 시 오차를 방지할 수 있다. 즉 CT와 MRI 영상이 가지고 있는 영상 표출 알고리즘의 장점을 이용하여 치료계획에 적용해야 할 것이다.

  • PDF

흉부 CT 검사에서 3차원 체적 영상의 정량적 분석 (Quantitative analysis of three dimensional volumetric images in Chest CT)

  • 장현철;조재환;박철수
    • 한국방사선학회논문지
    • /
    • 제5권5호
    • /
    • pp.255-260
    • /
    • 2011
  • 본 연구는 흉부 CT 검사 시 늑골 골절 환자를 대상으로 3차원 체적 재구성 기법의 유용성에 대해 알아보고자 하였다. 임상에서 주로 이용 하는 재구성기법인 다평면재구성(MPR), 3차원 체적 영상 기법(VRT)을 적용하여 영상데이터를 각 각 정량적 방법과 정성적 방법으로 비교 분석하였다. 재구성 영상의 분석 및 평가결과 늑골 골절 환자의 흉부 CT 검사 시 조영 전 원 자료를 이용하여 3차원 체적영상으로 재구성 하는 것이 보다 더 인공 음영을 최소화 시켰으며, 늑골 골절 판단 및 3차원 체적 영상 재구성 소요시간이 단축 됨을 알 수 있었다.

뇌전산화단층검사에서 방사선량 저감을 위한 최적화 프로토콜 연구 (Optimization of Brain Computed Tomography Protocols to Radiation Dose Reduction)

  • 이재승;권대철
    • 대한의용생체공학회:의공학회지
    • /
    • 제39권3호
    • /
    • pp.116-123
    • /
    • 2018
  • This study is a model experimental study using a phantom to propose an optimized brain CT scan protocol that can reduce the radiation dose of a patient and remain quality of image. We investigate the CT scan parameters of brain CT in clinical medical institutions and to measure the important parameters that determine the quality of CT images. We used 52 multislice spiral CT (SOMATOM Definition AS+, Siemens Healthcare, Germany). The scan parameters were tube voltage (kVp), tube current (mAs), scan time, slice thickness, pitch, and scan field of view (SFOV) directly related to the patient's exposure dose. The CT dose indicators were CTDIvol and DLP. The CT images were obtained while increasing the imaging conditions constantly from the phantom limit value (Q1) to the maximum value (Q4) for AAPM CT performance evaluation. And statistics analyzed with Pearson's correlation coefficients. The result of tube voltage that the increase in tube voltage proportionally increases the variation range of the CT number. And similar results were obtained in the qualitative evaluation of the CT image compared to the tube voltage of 120 kVp, which was applied clinically at 100 kVp. Also, the scan conditions were appropriate in the tube current range of 250 mAs to 350 mAs when the tube voltage was 100 kVp. Therefore, by applying the proposed brain CT scanning parameters can be reduced the radiation dose of the patient while maintaining quality of image.

Effect of Gd-based MR contrast agents on CT attenuation of PET/CT for quantitative PET-MRI study

  • Ko, In OK;Park, Ji Ae;Lee, Won Ho;Lim, Sang Moo;Kim, Kyeong Min
    • 대한방사성의약품학회지
    • /
    • 제1권2호
    • /
    • pp.130-136
    • /
    • 2015
  • We evaluate the influence of MR contrast agent on positron emission tomography (PET) image using phantom, animal and human studies. Phantom consisted of 15 solutions with the mixture of various concentrations of Gd-based MR contrast agent and fixed activity of [$^{18}F$]FDG. Animal study was performed using rabbit and two kinds of MR contrast agents. After injecting contrast agent, CT or MRI scanning was performed at 1, 2, 5, 10, and 20 minutes. PET image was obtained using clinical PET/CT scan, and attenuation correction was performed using the all CT images. The values of HU, PET activity and MRI intensity were obtained from ROIs in each phantom and organ regions. In clinical study, patients (n=20) with breast cancer underwent sequential acquisitions of early [$^{18}F$]FDG PET/CT, MRI and delayed PET/CT. In phantom study, as the concentration increased, the CT attenuation and PET activity also increased. However, there was no relationship between the PET activity and the concentration in the clinical dose range of contrast agent. In animal study, change of PET activity was not significant at all time point of CT scan both MR contrast agents. There was no significant change of HU between early and delayed CT, except for kidney. Early and delayed SUV in tumor and liver showed significant increase and decrease, respectively (P<0.05). Under the condition of most clinical study (< 0.2 mM), MR contrast agent did not influence on PET image quantitation.

Unet-VGG16 모델을 활용한 순환골재 마이크로-CT 미세구조의 천연골재 분할 (Segmentation of Natural Fine Aggregates in Micro-CT Microstructures of Recycled Aggregates Using Unet-VGG16)

  • 홍성욱;문덕기;김세윤;한동석
    • 한국전산구조공학회논문집
    • /
    • 제37권2호
    • /
    • pp.143-149
    • /
    • 2024
  • 이미지 분석을 통한 재료의 상 구분은 재료의 미세구조 분석을 위해 필수적이다. 이미지 분석에 주로 사용되는 마이크로-CT 이미지는 대체로 재료를 구성하고 있는 상에 따라 회색조 값이 다르게 나타나므로 이미지의 회색조 값 비교를 통해 상을 구분한다. 순환골재의 고체상은 수화된 시멘트풀과 천연골재로 구분되는데, 시멘트풀과 천연골재는 CT이미지 상에서 유사한 회색조 분포를 보여 상을 구분하기 어렵다. 본 연구에서는 Unet-VGG16 네트워크를 활용하여 순환골재 CT 이미지로부터 천연골재를 분할하는 자동화 방법을 제안하였다. 딥러닝 네트워크를 활용하여 2차원 순환골재 CT 이미지로부터 천연골재 영역을 분할하는 방법과 이를 3차원으로 적층하여 3차원 천연골재 이미지를 얻는 방법을 제시하였다. 선별된 3차원 천연골재 이미지에서 각각의 골재 입자를 분할하기 위해 이미지 필터링을 사용하였다. 골재 영역 분할 성능을 정확도, 정밀도, 재현율 F1 스코어를 통해 검증하였다.

적응 양자화를 위한 의료 영상 정보의 변환 부호화에 관한 연구 (A Study Transform Coding of Medical Image Using Adaptive Quantization Method)

  • 한영오;박장춘
    • 대한의용생체공학회:의공학회지
    • /
    • 제10권3호
    • /
    • pp.243-252
    • /
    • 1989
  • In this study, medical images, which are X-ray image and CT image, are compressed by the adam live coding technique. The medical images may be treated as special ones, because they are different from general images in many respects. The statistical characteristics that medical images only have in transform domain are analyzed, and then the improved quantization method is proposed for medical images. For chest X-ray image and CT head image, the better results are obtained by the improved adaptive coding technique.

  • PDF

퍼지 이론을 이용한 의료 영상 특징 추출에 관한 연구 (A study on segmentation of medical image using fuzzy set theory)

  • 김형석;한영오;박상희
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1991년도 한국자동제어학술회의논문집(국내학술편); KOEX, Seoul; 22-24 Oct. 1991
    • /
    • pp.741-745
    • /
    • 1991
  • This paper describes a feature extraction in digitized chest X-ray image and CT head Image. There are Extraction, Thresholding, Region G rowing, Split-Merge and Relaxation in feature extraction technique. In this study, Region Growing System was realized and Fuzzy Set Theory was applied in order to extract the vague region which the conventional method has difficulties in extracting. The performance of proposed algorithm was proved by being applied to chest X-ray image and CT head image.

  • PDF

전산화단층촬영 시 환자 고정 밴드를 이용한 선량의 선택 (Selection of mAs with Using Table Strap in Computed Tomography Scan)

  • 이용현;안형택
    • 대한디지털의료영상학회논문지
    • /
    • 제13권2호
    • /
    • pp.63-69
    • /
    • 2011
  • Table strapis patient fixture for securing the patient movements and falls. if it designed to measure the abdominal circumference and used as an indicator of dose selection at CT scan. it will prevent the overexposure of dose without degradation of image quality and efficiently manage dose of each type of body to technician to deal with CT. First, in order to compare the dose used in CT image and qualitative characteristics. reference image is obtained by examining the abdominal phantom in same conditions with the hospital 120 kVp, 200 mAs, D-Dom (Dynamic Dose Of Modulation). SNR, PSNR, RMSE, MAE, CTDIvol of CT images are compared with reference image. for comparing with reference image, the image that Umbilicus level image of Abdomen CT is stored in the PACS were used. For comparison, the top 12 o'clock portion of the air drawn from the same ROI was measured. CTDIvol, mAs, etc. In order to analyze the characteristics of the image, by measuring the length of the umbilicus circumference, pattern of the dose was analyzed. by using the analyzed perimeter and dose information, To be identified visually, fixed band that scale marked were produced. Use them, If the length of circumference of less than 60 cm 100 mAs, Case of 61~80 cm 120 mAs, Case of 80~100 cm 150 mAs, more than 100 cm 200 mAs, dose selection based on the perimeter, the image was applied. by compare analyzed with the Reference Image, image quality was assessed. by compare with existing tests that equally 200 mAs applied, How much was confirmed that the dose reduction. 1. Depending on the Abdominal circumference, the average PSNR(dB) of the image that differently dose applied was 45.794. 2. Comparing with existing test. the dose of scan that adjusted the mAs depending on the circumference was decreased about 40%. SNR and PSNR of the image that obtained by adjusting the standard mAs based on dose modulation were not much different. Therefore, By choosing a low mAs. dose reduction can be obtained. and the dose selection method that measured Abdominal circumference using a fixed band can protect the overexposure and uniformly apply dose of each type of body to technician to deal with CT.

  • PDF

PET/CT 검사에서 횡격막에 의한 인공물의 CTAC Shift 보정방법의 유용성 (Usefulness of CTAC Shift Revision Method of Artifact by Diaphragm in PET/CT)

  • 함준철;강천구;조석원;반영각;이승재;임한상;김재삼;이창호
    • 핵의학기술
    • /
    • 제17권1호
    • /
    • pp.71-75
    • /
    • 2013
  • 현재 PET/CT 검사에서 저선량 CT를 이용한 감쇠 보정을 사용하고 있다. 하지만 환자 호흡으로 인한 횡격막 부근의 저선량 CT 영상과 Emission 영상의 불일치로 감쇠 보정영상에서 Artifact가 발생하는 경우가 있다. 본 연구는 보정방법 중 CTAC Shift를 이용하여 환자의 호흡에 의한 Artifact의 감소를 연구했다. 2012년 3월부터 9월까지 PET/CT Discovery 600 (GE Healthcare, MI, USA) 장비를 이용하여 호흡에 의한 Artifact가 발생한 환자 30명을 대상으로 했다. Artifact가 발생한 환자는 횡격막 부분을 추가검사하였고, 전신 검사 시 Artifact가 발생한 영상을 CTAC Shift를 이용하여 보정했다. Artifact 발생 영상, 추가 검사영상, CTAC Shift 보정 영상의 육안적 평가는 핵의학 전문의 1명과 5년 이상 근무한 방사선사 4명에 의해 1-5점으로 나누어 평가했다. 또한 각 영상의 표준섭취화 계수를 ANOVA를 이용하여 비교했다. Artifact 발생 영상에 비해 추가 검사 영상과 CTAC Shift 보정 영상은 육안적 평가에서 상대적으로 높은 점수를 받았다. 추가 검사 영상과 CTAC Shift 보정 영상은 표준섭취화 계수의 ANOVA 결과, 높은 상관관계를 갖고 있으며, 유의한 차이를 보이지 않았다. PET/CT 검사 시 환자의 호흡에 의한 Artifact가 발생 할 경우 추가 검사로 인한 검사 시간이 증가하여 환자의 불편 뿐 아니라 피폭도 증가한다. 하지만 추가 검사 없이 CTAC Shift를 이용하여 보정된 영상을 획득한다면 불필요한 피폭 및 추가 검사도 감소하며, 정확한 진단에 도움을 줄 것으로 사료된다.

  • PDF