• 제목/요약/키워드: CT evaluation

검색결과 1,322건 처리시간 0.027초

대장-직장 및 항문암에서 F-18 FDG PET (PET/CT)의 임상 이용 (Clinical Application of F-18 FDG PET (PET/CT) in Colo-rectal and Anal Cancer)

  • 김병일
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제42권sup1호
    • /
    • pp.52-59
    • /
    • 2008
  • In the management of colo-retal and anal cancer, accurate staging, treatment evaluation, early detection of recurrence are main clinical problems. F-18 FDG PET (PET/CT) has been reported as useful in the management of colo-rectal and anal cancer because that PET has high diagnostic performance comparing to conventional studies. In case of liver metastases, for confirmation of no extrahepatic metastases, in case of high risk of metastasis, for avoiding unnecessary operation, PET (PET/CT) is expected more useful. In anal cancer, PET is expected useful in lymph node staging. For the early prediction of chemotherapy or radiation therapy effect PET has been reported as useful, also. In early detection of recurrence by PET, cost-benefit advantages has been suggested, also. PET/CT is expected to have higher diagnostic performance than PET alone.

연속적인 FDG-PET/CT 검사에서 섭취 감소로 관찰된 비소세포암의 뇌전이 (Sequential Change of Hypometabolic Metastasis from Non-small-cell Lung Cancer on Brain FDG-PET/CT)

  • 박순아;양세훈;양충용;최금하
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제43권5호
    • /
    • pp.505-507
    • /
    • 2009
  • A 60-year-old woman, who had non-small-cell lung cancer (NSCLC) in left lower lobe underwent brain F-18 fluorodeoxyglucose positron emission tomography/computed tomography (FDG-PET/CT) for evaluation of cerebral metastasis. On follow-up FDG-PET/CT, only hypometaolic lesion was detected and progressed in right frontal lobe at 6 months and 10 months, later. Hypermetabolic metastasis was not detected even at last scan time of FDG-PET/CT. Brain MRI showed brain metastasis in right frontal lobe. As might be expected, the physician should take cerebral metastasis into consideration even though there is only hypometabolic change on subsequent FDG-PET/CT in patients with NSCLC.

Brain PET에서 Truncated Region에 의한 영상의 질 평가 (Evaluation of Image Quality Change by Truncated Region in Brain PET/CT)

  • 이홍재;도용호;김진의
    • 핵의학기술
    • /
    • 제19권2호
    • /
    • pp.68-73
    • /
    • 2015
  • PET/CT 검사 시 검사 부위에 따라 적절한 액세서리의 사용이 권고되고 있다. 그 중 brain 검사에서 사용되는 액세서리인 brain holder를 사용하지 않는 경우 CT의 small FOV에 의하여 whole pallet이 AC-CT에 cover되지 않으며, 이에 따른 truncated region에 따라 count loss가 발생된다. 본 논문에서는 brain holder를 사용하지 않았을 경우 발생하는 truncated region에 의한 image quality의 변화를 평가하고자 한다. Siemens사의 biograph truepoint40 장비와 $^{68}Ge$-uniform phantom을 사용하여 $^{68}Ge$ phantom을 pallet위에서 스캔하고 brain holder위에 위치하고 스캔 하였다. brain protocol을 적용하여 holder를 사용하지 않은 경우 pallet이 AC-CT의 FOV에 포함되지 않는 것을 알 수 있었다. 획득된 영상을 FBP, OSEM, TrueX recon method를 이용하여 iteration 4, subsets 21, gaussian 2 mm와 5 mm parameter를 적용하여 재구성 후 Window level : -4200, window width : 1000으로 설정하여 영상의 uniformity를 평가하였으며, vertical profile을 생성하여 count uniformity를 평가하였고, 마지막으로 5장과 20장의 slice를 summation하여 integral uniformity를 평가하였다. AC-CT영상을 통하여 holder를 사용하지 않는 경우 FOV내에 pallet이 모두 포함되지 않는 것을 알 수 있으며, 이에 따른 truncation에 의한 부정확한 attenuation factor가 나타났다 PET corrected sinogram 영상에서 holder를 사용하지 않은 경우 truncated region에 의한 defect 부위를 확인할 수 있으며, holder를 사용한 경우 uniform한 영상을 확인할 수 있었다. Window level : 4200, window width : 1000으로 설정 시 FBP, OSEM, TrueX recon 방법 모두에서 holder를 사용한 경우 uniform한 영상이 획득되었지만, holder를 사용하지 않은 경우 하단에 defect가 관찰되었다. Holder를 사용한 경우와 사용하지 않은 경우의 영상을 각 5장, 20장씩 summation하여 NEMA method에 따라 integral uniformity를 구하였으며, 5장 slice의 summation에서 holder를 사용하지 않은 경우 11.7% holder를 사용한 경우 7.2%로 나타났다. 20장 slice의 summation에서 holder를 사용하지 않은 경우 11.1% holder를 사용한 경우 76.7%로 나타났다. brain 검사 시 holder를 사용하지 않는 경우 truncated region에 따른 phantom 하단부의 count defect가 확인되었으며, 이는 환자 검사 시 occipital lobe의 count loss를 발생하게 되며 research 검사 시 검사 결과의 오차를 발생하게 됨으로 brain PET/CT 검사 시 정확한 검사결과를 위하여 검사 액세서리가 반드시 적용되어야 할 것이다.

  • PDF

Micro-CT를 이용한 복합 레진 수복물 미세 누출도의 정량 분석 (Quantitative Micro-CT Evaluation of Microleakage in Composite Resin Restorations)

  • 이상익;현홍근;김영재;김정욱;이상훈;김종철;한세현;장기택
    • 대한소아치과학회지
    • /
    • 제34권2호
    • /
    • pp.222-233
    • /
    • 2007
  • 치과 수복 재료 검사 시 가장 중요하고 기본적인 것은 치아와 수복물 사이의 미세누출에 대한 평가이다. 미세 누출을 평가하는 방법은 여러 가지가 있지만 이들 대부분은 많은 단점들을 가지고 있다. 최근에 개발된 미세 단층촬영법(micro-CT)을 이용하면 시편을 비파괴적으로 처리하여 특정 밀도에 해당하는 부분의 3차원적 영상을 얻을 수 있으므로, 이를 이용하면 정확하고 정량적인 미세누출 평가도 가능할 것이다. 이 연구의 목적은 micro-CT를 사용하여, 레진 수복물의 미세 누출도를 정량적이고 비파괴적으로 측정할 수 있는 새로운 방법을 찾아내고, 이 새로운 방법을 기존의 색소 침투법과 비교해보는 것이다. 이를 위해, 위의 두 가지 방법을 사용하여 두 종류의 상아질 접착 시스템의 미세누출도가 평가되었다. 사람의 건전 소구치 40개를 임의로 20개씩 두 군으로 나누고 다음과 같이 처리하였다. Group 1 : $Adper^{TM}$ Singe Bond 사용 후 제 V급 와동 레진 수복, Gourp 2 : $Adper^{TM}\;Promp^{TM}$ L-pop 사용 후 제 V급 와동 레진 수복 모든 치아의 5급 와동은 $Filtek^{TM}$ Supreme으로 수복하였다. 그 후 각 군 중 10개의 치아는 micro-CT를 사용하여 미세 누출도를 평가하고, 나머지 10개는 기존의 색소 침투법으로 평가하였다. 이 연구의 결과는 다음과 같았다. 1. Micro-CT를 사용한 경우, 1군은 2군보다 통계적으로 유의성 있게 적은 양의 미세 누출을 보였다(p<0.01). 2. 기존의 색소 침투법을 사용한 경우에서 1군은 2군보다 적은 미세누출을 보였으며 이는 통계적으로 유의성이 있었다. (p<0.01). 3. 두 군간의 미세 누출도는 micro-CT를 사용한 방법에서 더 현저한 차이를 보였다. 4. 두 가지 방법 모두에서 법랑질 변연 부분보다 상아질 변연 부분에서 더 많은 미세 누출을 보였다.

  • PDF

LBB 평가를 위한 J-R 파괴인성시험 결과에 미치는 시편 형상과 측면 홈의 영향 (Effects of Specimen Size and Side-groove on the Results of J-R Fracture Toughness Test for LBB Evaluation)

  • 김진원;최명락;오영진;박흥배;김경수
    • 대한기계학회논문집A
    • /
    • 제39권7호
    • /
    • pp.729-736
    • /
    • 2015
  • 본 논문에서는 파단전누설 평가를 위한 J-R 파괴인성시험에 미치는 시편 크기와 측면 홈의 영향을 분석하였다. 이를 위해서 SA508 Gr.1a 배관재에서 채취된 측면 홈이 가공되거나 가공되지 않은 크기가 다른 3종류의 CT 시편(12.7mm 두께의 1T-CT, 25.4mm 두께의 1T-CT, 25.4mm 두께의 2T-CT)을 이용하여 상온과 $316^{\circ}C$에서 J-R 시험을 수행하였다. 시험 결과, 시편 두께에 관계없이 측면 홈이 가공된 시편은 측면 홈이 없는 시편에 비해 낮은 J-R 곡선을 보였으며, 상온에 비해 $316^{\circ}C$에서 측면 홈의 영향이 더욱 뚜렷하였다. 상온에서는 시편의 두께가 감소하고 폭이 증가함에 따라 J-R 곡선이 약간씩 감소하는 경향을 보였으나, $316^{\circ}C$에서는 시편의 두께가 감소하고 폭이 증가됨에 따라 J-R 곡선이 증가하였다. 그러나 SA508 Gr.1a 배관재에서 전체적으로 시편의 폭과 두께에 따른 J-R 곡선의 변화는 크지 않았다.

The evaluation of the correlation between histomorphometric analysis and micro-computed tomography analysis in AdBMP-2 induced bone regeneration in rat calvarial defects

  • Park, Shin-Young;Kim, Kyoung-Hwa;Koo, Ki-Tae;Lee, Kang-Woon;Lee, Yong-Moo;Chung, Chong-Pyoung;Seol, Yang-Jo
    • Journal of Periodontal and Implant Science
    • /
    • 제41권5호
    • /
    • pp.218-226
    • /
    • 2011
  • Purpose: Micro-computed tomography (micro-CT) has been widely used in the evaluation of regenerated bone tissue but the reliability of micro-CT has not yet been established. This study evaluated the correlation between histomorphometric analysis and micro-CT analysis in performing new bone formation measurement. Methods: Critical-size calvarial defects were created using a 8 mm trephine bur in a total of 24 Sprague-Dawley rats, and collagen gel mixed with autogenous rat bone marrow stromal cells (BMSCs) or autogenous rat BMSCs transduced by adenovirus containing bone morphogenic protein-2 (BMP-2) genes was loaded into the defect site. In the control group, collagen gel alone was loaded into the defect. After 2 and 4 weeks, the animals were euthanized and calvaria containing defects were harvested. Micro-CT analysis and histomorphometric analysis of each sample were accomplished and the statistical evaluation about the correlation between both analyses was performed. Results: New bone formation of the BMP-2 group was greater than that of the other groups at 2 and 4 weeks in both histomorphometric analysis and micro-CT analysis (P=0.026, P=0.034). Histomorphometric analysis of representative sections showed similar results to histomorphometric analysis with a mean value of 3 sections. Measurement of new bone formation was highly correlated between histomorphometric analysis and micro-CT analysis, especially at the low lower threshold level at 2 weeks (adjusted $r^2=0.907$, P<0.001). New bone formation of the BMP-2 group analyzed by micro-CT tended to decline sharply with an increasing lower threshold level, and it was statistically significant (P<0.001). Conclusions: Both histomorphometric analysis and micro-CT analysis were valid methods for measurement of the new bone in rat calvarial defects and the ability to detect the new bone in micro-CT analysis was highly influenced by the threshold level in the BMP-2 group at early stage.

블라인드 품질 평가 방법을 사용한 주석필터 사용 유무에 따른 CT 영상 특성 비교 (Comparison of CT Image Performance with or without Tin Filter based on Blind Image Quality Evaluation Method)

  • 심지나;이영진
    • 한국방사선학회논문지
    • /
    • 제15권3호
    • /
    • pp.301-306
    • /
    • 2021
  • 전산화단층촬영장치 (Computed tomography, CT)의 의료 방사선량을 낮추기 위한 방법으로 주석필터의 사용을 통해 직접적으로 환자의 선량을 낮추는 방법이 있다. 그러나 주석필터의 사용으로 바뀐 X선 스펙트럼으로 인해 기존의 영상과 다른 인상의 영상으로 나타나기 때문에 질병 진단에 영향을 줄 수 있다. 따라서 본 연구에서는 흉부 저선량 CT에서 주석필터의 적용 및 high pitch에 따른 영상평가를 진행함으로써 주석필터 사용 시 영상의 변화 양상을 살펴보았다. 본 연구에서는 비교를 위해 총 3개의 그룹으로 나누어 영상을 획득하였다. Group 1은 주석필터를 사용하지 않았으며, 기존에 사용하던 pitch인 0.8의 영상을 획득하였다. Group 2는 주석필터를 사용하였고, pitch는 0.8이며 Group 3은 주석필터를 사용하였으며 pitch는 2.5이다. 영상의 화질을 비교하기 위해 no-reference 기반으로 사용되는 블라인드 품질 평가 인자 중 natural image quality evaluator (NIQE)와 blind/referenceless image spatial quality evaluator (BRISQUE)를 사용하였다. 그 결과 NIQE 수치는 Group 1, Group 3, Group 2 의 순서대로 낮게 나타났다. BRISQUE 수치는 Group 3, Group 2, Group 1 의 순서대로 낮게 나타났다. 이를 통해 흉부 저선량 CT에서 주석필터 및 high pitch 기술의 영상의 우수성을 확인함으로써 특히 호흡 조절이 어려운 흉부 저선량 CT 환자에 있어서 더 정확한 영상에 대한 기대감을 가질 수 있는 기초 자료로 활용될 수 있을 것이라 사료된다.

Imaging of Gastric Cancer Metabolism Using 18 F-FDG PET/CT

  • Yun, Mijin
    • Journal of Gastric Cancer
    • /
    • 제14권1호
    • /
    • pp.1-6
    • /
    • 2014
  • Aerobic glycolysis has been the most important hypothesis in cancer metabolism. It seems to be related to increased bioenergetic and biosynthetic needs in rapidly proliferating cancer cells. To this end, F-18 fluorodeoxyglucose (FDG), a glucose analog, became widely popular for the detection of malignancies combined with positron emission tomography/computed tomography (PET/CT). Although the potential roles of FDG PET/CT in primary tumor detection are not fully established, it seems to have a limited sensitivity in detecting early gastric cancer and mainly signet ring or non-solid types of advanced gastric cancer. In evaluating lymph node metastases, the location of lymph nodes and the degree of FDG uptake in primary tumors appear to be important factors affecting the diagnostic accuracy of PET/CT. In spite of the limited sensitivity, the high specificity of PET/CT for lymph node metastases may play an important role in changing the extent of lymphadenectomy or reducing futile laparotomies. For peritoneal metastases, PET/CT seems to have a poorer sensitivity but a better specificity than CT. The roles of PET/CT in the evaluation of other distant metastases are yet to be known. Studies including primary tumors with low FDG uptake or peritoneal recurrence seem suffer from poorer diagnostic performance for the detection of recurrent gastric cancer. There are only a few reports using FDG PET/CT to predict response to neoadjuvant or adjuvant chemotherapy. A complete metabolic response seems to be predictive of more favorable prognosis.

뇌혈관조영검사 시 단일에너지 CT와 이중에너지 CT의 비교평가 : 화질 및 유효선량평가 (Comparative Evaluation of Single-Energy CT and Dual-Energy CT in Brain Angiography : Using a Rando Phantom and OSLD)

  • 신병근;안성민
    • 한국방사선학회논문지
    • /
    • 제17권6호
    • /
    • pp.809-817
    • /
    • 2023
  • 뇌출혈 진단 방법 중 CT는 비침습적으로 피사체의 3차원 영상을 제공할 수 있다. 그래서 응급실에서 급성인 환자 상대로 많이 사용되고 중요한 역할을 담당하고 있다. 뇌혈관 CT는 다른 혈관 CT에 비해 비교적 촬영 빈도가 높으며 뇌혈관 CT 검사 시 적절한 SNR, 합리적인 유효선량으로 검사를 해야한다. 뇌혈관 CT 검사 시 이중에너지와 단일에너지를 이용하였을 때 실질적으로 어느 것이 유효선량이 적으며, SNR이 차이가 없는지 환자영상과 Phantom영상을 같이 비교하였다. SNR과 CNR의 P값이 0.05이상일 때 통계적으로 차이가 없다고 보았고, 유효선량은 0.05미만일 경우 통계적으로 차이가 있다고 보았다. 실험에서는 병원영상의 환자선량을 비교하였을 때 이중에너지의 유효선량이 53.53% 적게, Phantom의 OLSD 이중에너지 유효선량이 57.94% 적게, Phantom의 Dose Report의 이중에너지 유효선량이 56.04% 적었다. 그래서 뇌혈관조영 CT는 이중에너지를 권장한다.

CT 혈관 조영 영상에서 뼈 소거법 기반의 하지 혈관 자동 추출 (Automatic Lower Extremity Vessel Extraction based on Bone Elimination Technique in CT Angiography Images)

  • 김수경;홍헬렌
    • 한국정보과학회논문지:소프트웨어및응용
    • /
    • 제36권12호
    • /
    • pp.967-976
    • /
    • 2009
  • 본 논문에서는 CT 및 CT 혈관 조영 영상에서 강체 정합 및 뼈 소거법을 이용한 하지 혈관 자동 추출 방법을 제안한다. 첫째, 뼈의 부분적인 움직임을 반영하기 위하여 해부학 정보를 바탕으로 하지를 자동 구역화하고, 둘째, CT와 CTA 영상간 움직임을 산정하기 위하여 거리지도 기반의 강체 정합을 수행한다. 셋째, CTA 영상에서 복잡한 구조를 갖는 뼈를 제거하고 뼈에 인접한 혈관이 깎이는 것을 방지하기 위하여 뼈 소거법과 혈관 마스킹 기법을 제안한다. 넷째, 정합오차 및 연골 등의 잡음을 줄이기 위하여 혈관 추적 기반의 후 처리 과정을 통하여 보정한다. 제안 방법의 평가를 위해 육안 평가와 정확성 평가 그리고 수행시간을 측정하였다. 육안 평가를 위해 차감 기법, 정합 후 차감 기법, 제안 방법을 적용한 결과를 볼륨렌더링과 최대 강도 투영영상을 사용하여 비교하였다. 정확성 평가를 위해 CTA 영상과 차감 기반 기법 및 제안 방법을 적용한 결과의 밝기값 분포도를 분석하였다. 실험 결과 뼈는 제거되고 가는 혈관 및 다른 조직의 손실 없이 혈관이 정확하게 추출되었음을 볼 수 있었고, 13명의 환자 데이터 전채에 대한 전체 수행시간은 약 40포 정도로 측정되었다.