• Title/Summary/Keyword: CT coronary angiography

Search Result 64, Processing Time 0.027 seconds

The clinical usefulness of 64 channel MDCT and 128 channel DSCT in coronary CT angiography (관상동맥 전산화단층촬영에서 64 channel MDCT와 128 channel DSCT의 임상 유용성 평가)

  • Choi, Nam-Gil;Choi, Jae-Seong;Han, Jae-Bok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.11
    • /
    • pp.4411-4417
    • /
    • 2010
  • This study was retrospectively to compare the exposure dose and the imaging quality in coronary CT angiography by using the 64 channel multidetector computed tomography and the 128 channel DSCT. Effective dose was calculated dose length product (DLP) by multiplied the convention factor of chest (0.017). Imaging quality was assessed by radiologists using the 5-point Likert scale. The DLP was ranged from 851 to $1277mGy{\cdot}cm$ (mean: 17.23 mSv) in the 64 channel MDCT and from 82 to $110mGy{\cdot}cm$ (mean: 1.58 mSv) in the of 128 channel DSCT, respectively. The score of imaging quality was respectively $3.31{\pm}0.62$ in 64 channel MDCT and $4.05{\pm}0.46$ in the 128 channel DSCT. The exposure dose of 128 channel DSCT has decreased 1ess 1/10. The score of imaging quality was significant difference between two modalities and the frequency (>4 good) in the 128 channel DSCT is about three times than that of the 64 channel MDCT. Therefore, the 128 channel DSCT in coronary CT angiography is clinically more effective modality for both investigators and patients.

Comparison of Radiation Doses between 64-slice Single Source and 128-slice Dual Source CT Coronary Angiography in patient (64-slice single source CT와 128-slice dual source CT를 이용한 관상동맥 조영 검사 시 환자선량 비교)

  • Kang, Yeong-Han
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.2
    • /
    • pp.129-136
    • /
    • 2012
  • The purpose of this study was to estimate radiation doses from 64-slice single source Computed Tomography(SSCT) coronary angiography(CA) and 128-slice dual source Computed Tomography(DSCT). With SSCT CA, the effective dose averaged approximately 13.86 mSv when two dose modulation was not. The mean effective dose for DSCT CA with retrospectively gated helical(RGH) technique was 11.87 mSv, when prospective ECG gating transverse(PGT) without dose modulation technique was 5.61 mSv. The one with dose modulation in PGT technique and flash mode were 3.04 mSv and flash mode was 0.98 mSv respectively. The lifetime attributable risk(LAR) of cancer incidence from SSCT RGH mode averaged approximately 1 for 1,176, and DSCT averaged 1 for 1,960(RGH mode), 1 for 3,030(PGT without modulation), 1 for 5,882(PGT with modulation). Because of CTCA is associated with non-negligible risk of cancer. Doses can be reduced by application PGT, FLASH than RGH using DSCT.

Fusion of 3D Cardiac SPECT and 64-Channel-CT Angiography Using Personal Computer in Functionally Relevant Coronary Artery Stenosis (개인용 컴퓨터를 이용한 기능 유관성 관상동맥 협착증의 삼차원 심장스펙트 사진과 64채널 전산화 단층 혈관촬영사진과의 융합)

  • Bahk, Yong-Whee
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.41 no.3
    • /
    • pp.252-254
    • /
    • 2007
  • Image fusion is fast catching attention as Wagner pointed out in his 2006 version of the recent progress and development presented at the annual meeting of Society of Nuclear Medicine. Prototypical fusion of bone scan and radiograph was already attempted at in 1961 when Fleming et al. published an article on strontium-85 bone scan. They simply superimposed dot scan on radiograph enabling simultaneous assessment of altered bone metabolism and local bone anatomy. Indeed the parallel reading of images of bone scan and radiography, CT, MRI or ultrasonography has been practiced in nuclear medicine long since. It is fortunate that recent development of computer science and technology along with the availability of refined CT and SPECT machines has permitted us to open a new avenue to digitally produce precise fusion image so that they can readily be read, exchanged and disseminated using internet. Ten years ago fusion was performed using Bresstrahlung SPECT/CT and it is now achievable by PET/CT and SPECT/CT software and SPECT/CT hardware. The merit of image fusion is its feasibility of reliable assessment of morphological and metabolic change. It is now applicable not only to stationary organs such as brain and skeleton but also to moving organs such as the heart, lung and stomach. Recently, we could create useful fusion image of cardiac SPECT and 64-channel CT angiograph. The former provided myocardial metabolic profile and the latter vascular narrowing in two patients with coronary artery stenosis and myocardial ischemia. Arterial stenosis was severe in Case 1 and mild in Case 2.

Evaluation of the Ostium in Anomalous Origin of the Right Coronary Artery with an Interarterial Course Using Dynamic Cardiac CT and Implications of Ostial Findings

  • Jin-Young Kim;Yoo Jin Hong;Kyunghwa Han;Suji Lee;Young Jin Kim;Byoung Wook Choi;Hye-Jeong Lee
    • Korean Journal of Radiology
    • /
    • v.23 no.2
    • /
    • pp.172-179
    • /
    • 2022
  • Objective: We aimed to evaluate the ostium of right coronary artery of anomalous origin from the left coronary sinus (AORL) with an interarterial course throughout the cardiac cycle on CT and analyze the clinical significance of the ostial findings. Materials and Methods: From January 2011 to December 2015, 68 patients (41 male, 57.3 ± 12.1 years) with AORL with an interarterial course and retrospective cardiac CT data were included. AORL was classified as high or low ostial location based on the pulmonary annulus in the diastolic and systolic phases on cardiac CT. In addition, the height, width, height/width ratio, area, and angle of the ostium were measured in both cardiac phases. After cardiac CT, patients were followed until December 31, 2020 for major adverse cardiac events (MACE). Clinical and CT characteristics associated with MACE were explored using Cox regression analysis. Results: During a median follow-up period of 2071 days (interquartile range, 1180.5-2747.3 days), 13 patients experienced MACE (19.1%, 13/68). Seven (10.3%, 7/68) had the ostial location change from high in the diastolic phase to low in the systolic phase. In the univariable analysis, younger age (hazard ratio [HR] = 0.918, p < 0.001), high ostial location (HR = 4.008, p = 0.036), larger height/width ratio (HR = 5.621, p = 0.049), and smaller ostial angle (HR = 0.846, p = 0.048) in the systolic phase were significant predictors of MACE. In multivariable cox regression analysis, younger age (adjusted HR = 0.917, p = 0.002) and high ostial location in the systolic phase (adjusted HR = 4.345, p = 0.026) were independent predictors of MACE. Conclusion: The ostial location of AORL with an interarterial course can change during the cardiac cycle, and high ostial location in the systolic phase was an independent predictor of MACE.

Prevalence of Decreased Myocardial Blood Flow in Symptomatic Patients with Patent Coronary Stents: Insights from Low-Dose Dynamic CT Myocardial Perfusion Imaging

  • Yuehua Li;Mingyuan Yuan;Mengmeng Yu;Zhigang Lu;Chengxing Shen;Yining Wang;Bin Lu;Jiayin Zhang
    • Korean Journal of Radiology
    • /
    • v.20 no.4
    • /
    • pp.621-630
    • /
    • 2019
  • Objective: To study the prevalence and clinical characteristics of decreased myocardial blood flow (MBF) quantified by dynamic computed tomography (CT) myocardial perfusion imaging (MPI) in symptomatic patients without in-stent restenosis. Materials and Methods: Thirty-seven (mean age, 71.3 ± 10 years; age range, 48-88 years; 31 males, 6 females) consecutive symptomatic patients with patent coronary stents and without obstructive de novo lesions were prospectively enrolled to undergo dynamic CT-MPI using a third-generation dual-source CT scanner. The shuttle-mode acquisition technique was used to image the complete left ventricle. A bolus of contrast media (50 mL; iopromide, 370 mg iodine/mL) was injected into the antecubital vein at a rate of 6 mL/s, followed by a 40-mL saline flush. The mean MBF value and other quantitative parameters were measured for each segment of both stented-vessel territories and reference territories. The MBFratio was defined as the ratio of the mean MBF value of the whole stent-vessel territory to that of the whole reference territory. An MBFratio of 0.85 was used as the cut-off value to distinguish hypoperfused from non-hypoperfused segments. Results: A total of 629 segments of 37 patients were ultimately included for analysis. The mean effective dose of dynamic CT-MPI was 3.1 ± 1.2 mSv (range, 1.7-6.3 mSv). The mean MBF of stent-vessel territories was decreased in 19 lesions and 81 segments. Compared to stent-vessel territories without hypoperfusion, the mean MBF and myocardial blood volume were markedly lower in hypoperfused stent-vessel territories (77.5 ± 16.6 mL/100 mL/min vs. 140.4 ± 24.1 mL/100 mL/min [p < 0.001] and 6.4 ± 3.7 mL/100 mL vs. 11.5 ± 4 mL/100 mL [p < 0.001, respectively]). Myocardial hypoperfusion in stentvessel territories was present in 48.6% (18/37) of patients. None of clinical parameters differed statistically significantly between hypoperfusion and non-hypoperfusion subgroups. Conclusion: Decreased MBF is commonly present in patients who are symptomatic after percutaneous coronary intervention, despite patent stents and can be detected by dynamic CT-MPI using a low radiation dose.

Skeleton Extraction of 3D Coronary Artery for Topological Shape Analysis (3차원 관상동맥의 위상적인 형상분석을 위한 골격 추출)

  • Lee, Jae-Jin;Kim, Jeong-Sik;Choi, Soo-Mi
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2005.11a
    • /
    • pp.700-702
    • /
    • 2005
  • 3차원 관상동맥처럼 위상 구조가 중요한 객체의 형상을 분석하기 위해서는 혈관의 분기점, 극단점, 혈관의 계층적 구조 관계 등의 정보를 함축적으로 표현할 수 있는 골격 추출이 매우 중요하다 본 논문에서는 3차원 CT 혈관조영술(3D CT Angiography)로 촬영된 영상으로부터 관상동맥의 3차원 골격을 추출하는 방법을 개발하였다. 먼저, CT 혈관조영술부터 획득한 슬라이스 이미지로부터 3차원 조작 및 수술 시뮬레이션 등을 위하여 혈관의 3차원 표면에 대한 메쉬 모델을 생성한다. 생성된 메쉬 모델이 임의로 변형된 후에도 자동으로 골격을 쉽게 추출할 수 있도록 메쉬 모델을 복셀화하는 단계를 거친다. 이렇게 얻어진 복셀모델로부터 유클리디언 거리 맵을 구성하여 discrete medial surface (DMS)을 생성하고 최종적으로 골격을 추출하게 된다. 이렇게 추출된 3차원 골격은 관상동맥 수술 시뮬레이션 등에서 다양한 형상 분석에 유용하게 사용될 수 있다.

  • PDF

Right Coronary Artery to Left Ventricular Fistula with a Giant Right Coronary Artery Aneurysm - A case report - (거대 우관상 동맥류를 동반한 우관상 동맥에서 좌심실로 유출되는 관상 동맥루 - 1예 보고 -)

  • Kang, Joon-Kyu;Huh, Jae-Hak;Chang, Ji-Min;Song, Cheol-Min
    • Journal of Chest Surgery
    • /
    • v.43 no.3
    • /
    • pp.296-299
    • /
    • 2010
  • A right coronary artery to left ventricular fistula with a giant right coronary artery aneurysm is a very rare condition. This requires surgical treatment because of the possibility of rupture of aneurysm, heart failure and infective endocarditis. A 47 years old male patient with dyspnea on exertion for 3 months was diagnosed as having a right coronary artery to left ventricular fistula with a giant right coronary artery aneurysm according to the CT and coronary artery angiography. We resected the aneurysm and performed a coronary artery bypass graft.

Microvascular Myocardial Ischemia in Patients With Diabetes Without Obstructive Coronary Stenosis and Its Association With Angina

  • Yarong Yu;Wenli Yang;Xu Dai;Lihua Yu;Ziting Lan;Xiaoying Ding;Jiayin Zhang
    • Korean Journal of Radiology
    • /
    • v.24 no.11
    • /
    • pp.1081-1092
    • /
    • 2023
  • Objective: To investigate the incidence of microvascular myocardial ischemia in diabetic patients without obstructive coronary artery disease (CAD) and its relationship with angina. Materials and Methods: Diabetic patients and an intermediate-to-high pretest probability of CAD were prospectively enrolled. Non-diabetic patients but with an intermediate-to-high pretest probability of CAD were retrospectively included as controls. The patients underwent dynamic computed tomography-myocardial perfusion imaging (CT-MPI) and coronary computed tomography angiography (CCTA) to quantify coronary stenosis, myocardial blood flow (MBF), and extracellular volume (ECV). The proportion of patients with microvascular myocardial ischemia, defined as any myocardial segment with a mean MBF ≤ of 100 mL/min/100 mL, in patients without obstructive CAD (Coronary Artery Disease-Reporting and Data System [CAD-RADS] grade 0-2 on CCTA) was determined. Various quantitative parameters of the patients with and without diabetes without obstructive CAD were compared. Multivariable analysis was used to determine the association between microvascular myocardial ischemia and angina symptoms in diabetic patients without obstructive CAD. Results: One hundred and fifty-two diabetic patients (mean age: 59.7 ± 10.7; 77 males) and 266 non-diabetic patients (62.0 ± 12.3; 167 males) were enrolled; CCTA revealed 113 and 155 patients without obstructive CAD, respectively. For patients without obstructive CAD, the mean global MBF was significantly lower for those with diabetes than for those without (152.8 mL/min/100 mL vs. 170.4 mL/min/100 mL, P < 0.001). The mean ECV was significantly higher for diabetic patients (27.2% vs. 25.8%, P = 0.009). Among the patients without obstructive CAD, the incidence of microvascular myocardial ischemia (36.3% [41/113] vs. 10.3% [16/155], P < 0.001) and interstitial fibrosis (69.9% [79/113] vs. 33.3% [8/24], P = 0.001) were significantly higher in diabetic patients than in the controls. The presence of microvascular myocardial ischemia was independently associated with angina symptoms (adjusted odds ratio = 3.439, P = 0.037) in diabetic patients but without obstructive CAD. Conclusion: Dynamic CT-MPI + CCTA revealed a high incidence of microvascular myocardial ischemia in diabetic patients without obstructive CAD. Microvascular myocardial ischemia is strongly associated with angina.

Comparison of Clinical Usefulness between N-13 Ammonia PET/CT and Tc-99m Sestamibi SPET in Coronary Artery Disease (관상동맥질환에서 N-13 암모니아 PET/CT와 Tc-99m 세스타미비 SPECT의 임상 유용성 비교)

  • Kong, Eun-Jung;Cho, Ihn-Ho;Chun, Kyung-Ah;Won, Kyu-Chang;Lee, Hyung-Woo;Park, Jeong-Sun;Shin, Dong-Gu;Kim, Young-Jo;Shim, Bong-Seop
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.5
    • /
    • pp.354-361
    • /
    • 2008
  • Purpose: N-13 ammonia uptake and retention in the myocardium is related to perfusion and metabolism. There are several potential advantages of N-13 ammonia positron emission tomography (PET) to detect myocardial ischemia, such as higher spatial resolution, greater counting efficiencies, and robust attenuation correction. But there are few reports comparing Tc-99m myocardial perfusion single photon emission tomography (MPS) and N-13 ammonia PET. We thus compared adenosine stress N-13 ammonia PET/CT and Tc-99m sestamibi MPS in patients with suspected coronary artery stenosis. Materials and Methods: Seventeen patients (male 13 : $63{\pm}11$ years old) underwent adenosine stress N-13 ammonia PET/CT (Discovery ST, GE), Tc-99m sestamibi MPS (dual head gamma camera, Hawkeye, GE) and coronary angiography within 1 week. N-13 ammonia PET/CT and Tc-99m sestamibi MPS images were assessed with a 20-segment model by visual interpretation and quantitative analysis using automatic quantitative software (Myovation, GE). Results: Both sensitivities and specificities of detecting an individual coronary artery stenosis were higher for N-13 ammonia PET/CT than Tc-99m sestamibi MPS (PET/CT: 91%/89% vs MPS: 65%/82%). N-13 ammonia PET/CT showed reversibility in 52% of segments that were considered non-reversibile by Tc-99m sestamibi MPS. In the 110 myocardial segments supplied by the stenotic coronary artery, N-13 ammonia PET/CT showed higher count densities than Tc-99m MPS on rest study (p < 0.01), and the difference of count density between the stress and the rest studies was also larger on N-13 ammonia PET/CT. Conclusion: Adenosine stress N-13 ammonia PET/CT had higher diagnostic sensitivity and specificity, more reversibility of perfusion defects and greater stress/rest uptake differences than Tc-99m sestamibi MPS. Accordingly, N-13 ammonia PET/CT might offer better assessment of myocardial ischemia and viability.

Findings on Chest Low-Dose CT Images of Group Exposed to Inorganic Dusts (분진에 노출되었던 집단의 흉부 저선량 CT영상 소견)

  • Lee, Won-Jeong;Seon, Jong-Ryul;Ahn, Bong-Seon;Park, Young-Sun
    • Journal of radiological science and technology
    • /
    • v.34 no.4
    • /
    • pp.305-314
    • /
    • 2011
  • The purpose of this study was to compare the findings on the chest low-dose CT (LDCT) images between the negative and positive groups for pneumoconiosis in the group exposed to inorganic dust. From May 30, 2007 to August 31, 2008, total 328 subjects were examined by a LDCT. LDCT images were read by a chest radiologist who has much experience for reading of pneumoconiosis. All subjects were classified into two groups based on digital images after consensus reading of two radiologists according to the ILO 2000 guidelines; negative group (87, 26.5%) without pneumoconiosis and positive group (241, 73.5%). Statistical analysis was performed using a SPSS 14.0. There were significant differences in age (60.9 vs. 65.0, p<0.001), and in dust expose duration (17.0 vs. 19.2, p=0.024) between two groups, but no significant difference in smoking (p=0.784). Of the 328 subjects, 13 diagnosis were extracted from 245 subjects (74.7%). Coronary artery calcification (CAC) was significantly higher in positive group than that in negative group (36.9% vs. 25.3%, p=0.049). Honeycombing showed higher frequency in positive group than in negative group (6.2% vs. 1.2%, p=0.079). Pneumoconiosis findings caused by inorganic dusts exposure showed the significant relation with CAC on LDCT images. Future studies need to prove that pneumoconiosis finding is independent risk factor for CAC using a coronary artery angiography.