• Title/Summary/Keyword: CT X ray

Search Result 961, Processing Time 0.029 seconds

Geometric Calibration of Cone-beam CT System for Image Guided Proton Therapy (영상유도 양성자치료를 위한 콘빔 CT 재구성 알고리즘: 기하학적 보정방법에 관한 연구)

  • Kim, Jin-Sung;Cho, Min-Kook;Cho, Young-Bin;Youn, Han-Bean;Kim, Ho-Kyung;Yoon, Myoung-Geun;Shin, Dong-Ho;Lee, Se-Byeung;Lee, Re-Na;Park, Sung-Yong;Cho, Kwan-Ho
    • Progress in Medical Physics
    • /
    • v.19 no.4
    • /
    • pp.209-218
    • /
    • 2008
  • According to improved radiation therapy technology such as IMRT and proton therapy, the accuracy of patient alignment system is more emphasized and IGRT is dominated research field in radiation oncology. We proposed to study the feasibility of cone-beam CT system using simple x-ray imaging systems for image guided proton therapy at National Cancer Center. 180 projection views ($2,304{\times}3,200$, 14 bit with 127 ${\mu}m$ pixel pitch) for the geometrical calibration phantom and humanoid phantoms (skull, abdomen) were acquired with $2^{\circ}$ step angle using x-ray imaging system of proton therapy gantry room ($360^{\circ}$ for 1 rotation). The geometrical calibration was performed for misalignments between the x-ray source and the flat-panel detector, such as distances and slanted angle using available algorithm. With the geometrically calibrated projection view, Feldkamp cone-beam algorithm using Ram-Lak filter was implemented for CBCT reconstruction images for skull and abdomen phantom. The distance from x-ray source to the gantry isocenter, the distance from the flat panel to the isocenter were calculated as 1,517.5 mm, 591.12 mm and the rotated angle of flat panel detector around x-ray beam axis was considered as $0.25^{\circ}$. It was observed that the blurring artifacts, originated from the rotation of the detector, in the reconstructed toomographs were significantly reduced after the geometrical calibration. The demonstrated CBCT images for the skull and abdomen phantoms are very promising. We performed the geometrical calibration of the large gantry rotation system with simple x-ray imaging devices for CBCT reconstruction. The CBCT system for proton therapy will be used as a main patient alignment system for image guided proton therapy.

  • PDF

Combined X-ray CT-SPECT System with a CZT Detector

  • Kwon, Soo-Il;Koji Iwata;Hasegawa, B-H
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.379-381
    • /
    • 2002
  • A single CdZnTe detector is tested for suitability in a prototype CT/ SPECT system designed to acquire both emission and transmission data. The detector has the size of 1${\times}$l-cm$^2$ with 4${\times}$4 1.5${\times}$l.5mm$^2$ pixellated anodes. Since the detector is smaller than imaged object, we translated it in an arc centered at the x-ray tube to image larger objects. Pulse counting electronics with very short shaping time (50 ns) are used to satisfy high photon rates in x-ray imaging, and response linearity up to 3${\times}$10$\^$5/ counts per second per detector element is achieved. The energy resolution of 122-keV gamma-ray is measured to be 14%. We have characterized the system performance by scanning a radiographic resolution phantom .and the Hoffman brain phantom. The spatial resolution of CT and SPECT are about 1 mm and 7 mm, respectively.

  • PDF

Internal Defects Inspection of Die-cast Parts via the Comparison of X-ray CT Image and CAD Data (CAD 데이터 및 엑스레이 CT이미지 비교를 통한 다이캐스팅 부품의 내부 결함 검사방법)

  • Hong, Gyeong Taek;Shim, Jae Hong
    • Journal of the Semiconductor & Display Technology
    • /
    • v.17 no.1
    • /
    • pp.27-34
    • /
    • 2018
  • Industrially, die-casting products are formed through casting, and so the methods to inspect the defects inside them are very restrictive. External inspection methods including visual inspection, sampling judgment, etc. enables researchers to inspect possible external defects, but x-ray inspection equipment has been generally used to inspect internal ones. Recently, they have been also applying three-dimensional internal inspections using CT equipment. However, they have their own limitations in applying to the use of industrial inspection due to limited detection size and long calculation time. To overcome the above problems, this paper has suggested a method to inspect internal defects by comparing the CAD data of the product to be inspected with the 3D data of the CT image. In this paper, we proposed a method for fast and accurate inspection in three dimensions by applying x-ray inspection to find internal defects in industrial parts such as aluminum die casting products. To show the effectiveness of the proposed method, a series of experiments have been carried out.

duoPIXTM X-ray Imaging Sensor Composing of Multiple Thin Film Transistors in a Pixel for Digital X-ray Detector (픽셀내 다수의 박막트랜지스터로 구성된 듀오픽스TM 엑스선 영상센서 제작)

  • Seung Ik, Jun;Bong Goo, Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.7
    • /
    • pp.969-974
    • /
    • 2022
  • In order to maximize dynamic range and to minimize image lag in digital X-ray imaging, diminishing residual parasitic capacitance in photodiode in pixels is critically necessary. These requirements are more specifically requested in dynamic X-ray imaging with high frame rate and low image lag for industrial 2D/3D automated X-ray inspection and medical CT imaging. This study proposes duoPIXTM X-ray imaging sensor for the first time that is composed of reset thin film transistor, readout thin film transistor and photodiode in a pixel. To verify duoPIXTM X-ray imaging sensor, designing duoPIXTM pixel and imaging sensor was executed first then X-ray imaging sensor with 105 ㎛ pixel pitch, 347 mm × 430 mm imaging area and 3300 × 4096 pixels (13.5M pixels) was fabricated and evaluated by using module tester and image viewer specifically for duoPIXTM imaging sensor.

Creation of Three-dimensional Convergence Model for Artifact Based on Optical Surface Scanning and X-ray CT: Sam-Chongtong Hand Canon in Jinju National Museum (광학식 표면스캐닝 및 X-선 CT를 활용한 유물의 3차원 융합모델 제작: 국립진주박물관 소장 삼총통)

  • Jo, Younghoon;Kim, Dasol;Kim, Haesol;Huh, Ilkwon;Song, Mingyu
    • Conservation Science in Museum
    • /
    • v.22
    • /
    • pp.15-26
    • /
    • 2019
  • This study was focused on the three-dimensional convergence modeling that can multilaterally analyze internal and external shapes of the Sam-Chongtong Hand Canon by optical precision scanning optimized for acquiring the surface shape and X-ray CT scanning used for obtaining the internal shape. First, the scanning results were converted by compatible extension, after which three-dimensional deviation analysis was conducted to verify mutual conformities. Accordingly, most (56.98%) deviations between the two scanning models was found be ±0.1mm. This result did not influence registration and merging based on the ICP algorithm. The merged data exhibited the external surface color, detailed shapes, internal width, and structure of the hand canon. The three-dimensional model based on optical surface scanning and X-ray CT scanning can be used for traditional technique interpretation as well as digital documentation of cultural heritage. In the future, it will contribute to deliver accessible scientific information of exhibits for visitors.

Combined X-ray CT/SPECT System with a Common CZT Detector (CZT검출기를 이용한 CT/SPECT 조합영상시스템)

  • 권수일
    • Progress in Medical Physics
    • /
    • v.13 no.4
    • /
    • pp.229-233
    • /
    • 2002
  • We have tested a combined CT/SPECT system with a single CZT detector for x-ray and gamma-ray medical imaging. The size of detector is 10$\times$10$\times$5 ㎣, and the anodes are pixellated as a 4$\times$4 array with a pixel dimension of $1.5\times$1.5 $\textrm{mm}^2$. The cathode was coated with a continuous Au-plated. We have characterized the system performance by scanning a radiographic resolution phantom and the Hoffman Brain phantom. Pulse counting electronics with very short shaping time (50 ㎱) are used to satisfy high photon rates in x-ray imaging, and response linearity up to 3$\times$10$^{5}$ counts per second per detector element is achieved. Energy resolution of 10.4% and 5.3% FWHM at Tc-99m 140 keV peak are obtained for the 50 ㎱ and 2 $mutextrm{s}$ shaping times, respectively. The spatial resolutions of CT and SPECT are about 1mm and 9mm, respectively. Photopeak efficiency of detector systems are 41.0% for 50㎱ and 72.5% for 2 $mutextrm{s}$ shaping time.

  • PDF

Evaluation of Freezing Patterns for Sand and Clay by Using X-ray CT (X-ray CT를 통한 사질토와 점성토의 간극수 동결 패턴 분석)

  • Song, Jun Young;Lee, Jangguen;Lee, Seong-Won;Lee, Junhwan;Yun, Tae Sup
    • Journal of the Korean Geotechnical Society
    • /
    • v.34 no.3
    • /
    • pp.57-65
    • /
    • 2018
  • This study adopts high resolution 3D X-ray CT imaging technique to visualize and evaluate the internal structure of experimentally frozen soils. Temperature and elastic wave velocity are also measured during the freezing process. The X-ray images of frozen specimens reveal that no changes in internal structure are observed for sand specimen, whereas systematic growth pattern of pore ice is observed within clay specimen. The freezing patterns are then quantified by a set of X-ray images with the aid of two-point correlation method by computing characteristic length Lr. The results reveal that characteristic length for pore ice freezing pattern in clay linearly increases with respect to the distance from the cooling source, so that Lr at the bottom layer is 2.5 times greater than the top layer when freezing process is completed. Furthermore, during the freezing process, local temperature differences are not observed in sand, but observed in clay specimen due to its relatively low thermal conductivity.

Development of Physical Human Bronchial Tree Models from X-ray CT Images (X선 CT영상으로부터 인체의 기관지 모델의 개발)

  • Won, Chul-Ho;Ro, Chul-Kyun
    • Journal of Sensor Science and Technology
    • /
    • v.11 no.5
    • /
    • pp.263-272
    • /
    • 2002
  • In this paper, we investigate the potential for retrieval of morphometric data from three dimensional images of conducting bronchus obtained by X-ray Computerized Tomography (CT) and to explore the potential for the use of rapid prototype machine to produce physical hollow bronchus casts for mathematical modeling and experimental verification of particle deposition models. We segment the bronchus of lung by mathematical morphology method from obtained images by CT. The surface data representing volumetric bronchus data in three dimensions are converted to STL(streolithography) file and three dimensional solid model is created by using input STL file and rapid prototype machine. Two physical hollow cast models are created from the CT images of bronchial tree phantom and living human bronchus. We evaluate the usefulness of the rapid prototype model of bronchial tree by comparing diameters of the cross sectional area bronchus segments of the original CT images and the rapid prototyping-derived models imaged by X-ray CT.

A Study on the Frequency of Occurrence of the Aortic Dissection using CT (CT 검사에서 대동맥박리(aortic dissection)의 발생빈도에 관한 고찰)

  • Dong, Kyung-Rae;Choi, Sung-Kwan;Jang, Young-Ill;Ro, Sang-Ho
    • Journal of radiological science and technology
    • /
    • v.31 no.2
    • /
    • pp.115-121
    • /
    • 2008
  • Purpose: Aortic Dissection is very dangerous, prognostic disease, which the bloodstream flow out of the true lumen of the aorta by the bursting of aortic intima resulting in a rapid dissociation of inner and outer layer from the media. It is difficult to diagnose aortic dissection clinically by normal X-ray. This study was to investigate the occurrence frequency by age and number of patients who are identified to be aortic dissection by CT (Computed Tomography) scan. Materials and methods: We investigated the trend of yearly fluctuation, gender, age, and department of clinical research of the 112 patients who conducted CT scan in C- University Hospital for two years from January 2005 to December 2006. The MIP and SSD which reconstructed CT image and the VRT image were obtained for the accurate observation. The result was investigated by comparing normal X-ray and CT scan. Results and Conclusion: 1. The yearly check of 112 patients conducted CT scan showed 37 people (41.9%) in 2005, and it was increased to 65 (58.1%) in 2006 by 1.4 times. 2. The gender distribution of patients given a CT scan showed 45 males (40.1%), and female 67 (59.9 %). The aortic dissection patients were 9 (20%) out of 45 males, 21 (31.3%) out of 67 females and women were 1.6 times more than men. Women are also 1.5 times more than men in the number of examinee. 3. The age distribution of patient's who conducted CT scan revealed that there was no patient under 30 years old while 88.3% of all patients were through 41 to 80 years old. The higher the age was, the higher the occurrence of aortic dissection was. The difference in the occurrence frequency of age was statistically significant (p<0.01). 4. The departments that requested CT scan were the emergency department 46 (41.1%), circulatory internal medicine 37 (33.0%), chest surgery 13 (11.6%), and others 6 (14.3%). The combined ratio of emergency medicine and circulatory internal medicine was 74.1% of all. The results show that the aortic dissection is a very dangerous disease whose patients visit mainly via the emergency room. 5. The aortic dissection patients had normal X-ray readings in 22 (73.3%) out of 30, and only 8 (26.7 percent) are abnormal in the X-ray diagnosis. Therefore, the CT scan needs to be enforced in order to assess accurately the disease of aortic dissection.

  • PDF