• 제목/요약/키워드: CT Scans

검색결과 552건 처리시간 0.023초

골격계진단에 있어서 핀홀스캔의 우월성 (Whether Pinhole Scan or Single Photon Emission Computed Tomography (SPECT) in the Diagnosis of Bone and Joint Diseases)

  • 박용휘
    • 대한핵의학회지
    • /
    • 제30권1호
    • /
    • pp.1-14
    • /
    • 1996
  • Since the publication of the first bone scintiscans in 1962 three decades have elapsed. The bone scan has made great strides during this period, becoming one of the most commonly used nuclear imaging tests. In spite of the progress, however, the specificity of bone scan has remained relatively low. As the result it is a common practice to seek additional information from radiograph, CT scan and MR image, which is euphemistically termed as "image fusion or co-location." The basic reason is the inapplicability of the classical piecemeal analysis to interpreting planar and SPECT bone scans. Such analysis has its base on the observation of elemental features of morphology, which include the size, shape, contour, location, topography and internal architecture. The physiochemical profile may well also be included. Understandably, however, the miniatured images of the planar bone scan cannot provide these features in acceptable detail and the same holds true even with SPECT Images which are but sliced views of the reconstructed planar scans. Fortunately pinhole scanning has the capacity to portray both the morphological and chemical profiles of bone and joint diseases in greater detail through true magnification. The magnitude of pinhole scan resolution is practically comparable to that of radiography as far as gross anatomy is concerned. Thus, we feel strongly that pinhole scanning is a potential breakthrough of the long-lamented low specificity of bone scan. This presentation will discuss the fun-damentals, advantages and disadvantages and the most recent advances of pinhole scanning. It high-lights the actual clinical applications of pinhole scanning in relation to the diagnosis of infective and inflammatory diseases of bone and joint.

  • PDF

DECT의 VNC 적용으로 조영제와 석회화의 식별 에너지 영역 분석 (Discrimination Energy Range Analysis of Contrast Agents and Calcification using by VNC Application of DECT)

  • 김현주
    • 한국방사선학회논문지
    • /
    • 제18권2호
    • /
    • pp.179-185
    • /
    • 2024
  • DECT의 다양한 에너지 스펙트럼 영상 구현기능을 적용하여 조영제와 석회화의 정량적 구분 가능성을 알아보기 위해 CNR과 SNR을 비교하여 화질의 변화를 분석하고, 기존 방법인 2회 스캔 적용 시와 실험에서 적용한 VNC 영상 구현 1회 스캔 시 선량 감소수준을 알아보았다. 그 결과 70 keV 영역에서 조영제와 석회화가 가장 잘 구분되었고, CNR, SNR도 우수하였으며 스캔 선량은 약 26.5% 감소효과가 있었다. 따라서 DECT 적용은 에너지별 가상 분광 영상 구현으로 석회화의 명암을 형성하여 시각적 그리고 정량적 구분에 매우 유의미한 결과를 도출할 수 있었다. 향후 환자의 나이, 성별 및 체형 등을 고려한 임상 연구를 시행하여 결과를 도출한다면 혈관 내 조영제가 유입된 상태에서도 석회화 정량 분석이 가능하여 환자의 검사 선량과 다 회 검사에 대한 부담감 감소에 큰 효과가 있을 것으로 사료된다.

종합검진 수검자의 관상동맥 전산화단층 혈관조영술 검사에서 관상동맥질환의 위험요인과 관련성 분석 (A Study on the Analysis of Risk Factors and Correlations of Coronary Artery Disease of the Examinee taking Coronary Computed Tomography Angiography in a Comprehensive Health Improvement Center)

  • 최민경;곽종혁;김광;이삼열
    • 한국방사선학회논문지
    • /
    • 제13권7호
    • /
    • pp.1005-1014
    • /
    • 2019
  • 본 연구는 건강검진 목적으로 시행된 관상동맥 CT에서의 성별, 연령에 따른 관상동맥질환 발견율에 대한 유용성과 글루코스, 총 콜레스테롤, 내장지방, 체질량지수, 중성지방, 고밀도지단백질(HDL), 저밀도지단백질(LDL) 각각의 인자들과 관상동맥질환과의 관련성에 대해 알아보았다. 총 299명의 수검자를 대상으로 후향적 분석을 실시 한 결과 관상동맥질환 발견율에 대해서는 남성, 50세 이상에서의 유병율이 높은 것으로 나타났으며, 통계적으로 유의성을 보였다. 특히 남성의 유병율(37.9%)은 여성의 유병율(17.0%) 보다 약 2배가 높은 것으로 확인되었다. 또한 관상동맥질환과 관계되는 혈액학적 요인으로는 글루코스와 고밀도지단백질(HDL)이 통계적으로 유의성을 보였다. 관상동맥질환의 예방 및 관리를 위해서는 글루코스와 고밀도지단백질(HDL)의 조절이 필요할 것으로 보이며, 다른 혈액학적 인자들과는 통계적으로 유의성은 낮았지만, 관상동맥질환에 대한 관리의 필요성이 확인되었다. 주요 결과로서 선별검사 목적으로 관상동맥 CT의 사용은 방사선 피폭 등의 문제점으로 인해 수검자의 성별, 나이를 고려하여 시행하는 것이 좋을 것으로 생각되며, 관상동맥 CT 시행 이전에 비침습적인 방법들의 선행검사를 통한 관상동맥 질환 검사가 필요함을 제안한다.

방사선치료계획을 위한 PET 종양용적 결정 연구: 컴퓨터 모의실험 (Determination of Tumor Volume in PET for the Radiation Treatment Planning: Computer Simulation)

  • 윤석남;조철우;이재성
    • 한국의학물리학회지:의학물리
    • /
    • 제16권4호
    • /
    • pp.183-191
    • /
    • 2005
  • PET 기기의 보급이 급속도로 증가하고 있으며 여러 임상 및 연구 분야에서 그 유용성이 입증되어 널리 이용되고 있다. 이 가운데서도 종양 진단 분야에서 PET의 활용도는 매우 높아 대부분의 PET검사를 종양 검사가 차지하고 있으며 특히 양성과 악성종양의 감별, 종양의 치료효과 판정 및 종양의 재발진단 등에 널리 이용되고 있다. 최근에는 PET과 CT를 결합한 PET-CT의 사용이 증가됨에 따라 방사선치료분야에서 PET의 활용에 대한 관심이 커지고 있다. 방사선치료를 위한 종양의 경계를 결정하기 위하여 해부학적인 영상인 CT를 이용하는 것이 보편적이나 이 경우 실제 암조직에 상관없이 모양만을 기준으로 삼으므로 암조직에 대한 방사선 치료 용량이 많거나 적을 수 있어 적절한 치료가 되지 않을 수 있다. 따라서 PET을 이용한 기능적이고 살아 있는 암조직의 정확한 용적 측정은 적절한 치료 지표를 줄 수 있어 매우 중요한 일이나 상대적으로 낮은 공간해상도에 의해 정확한 경계를 결정하기 어려운 문제가 있다. 이 연구에서는 실제 종양의 용적을 구할 수 있는 영상화소 값의 역치가 변변의 크기, PET 기기의 공간해상도, 병변 대 주변 섭취비에 어떠한 영향을 받는지를 평가하기 위한 컴퓨터 모의실험을 수행하였다.

  • PDF

CT 조사를 통한 부여 능산리사지 출토 소조보살상의 제작 기법과 재료적 특성 연구 (A Study on the Production Techniques and Raw Material Characteristics of Clay Bodhisattva Excavated from the Neungsan-ri Temple Site Using CT)

  • 신연홍;노지현;김지호;박학수
    • 박물관보존과학
    • /
    • 제29권
    • /
    • pp.153-162
    • /
    • 2023
  • 소조상은 흙을 이용해 형상을 새기거나 빚어서 만든 것으로 특히 백제의 소조상은 주로 사찰과 관련된 유적에서 확인되고 있어, 백제의 불교미술을 연구하는 데 중요한 정보를 제공한다. 백제 소조상과 관련한 연구는 출토 위치에 따른 백제 사찰의 성격과 소조상의 역할, 지역별·형태적 특징 비교를 통한 제작 기법 연구 등이 주를 이루고 있다. 특히 소조상의 제작 기법에 관한 연구는 육안 관찰에 의한 경우가 대부분으로 보다 상세한 제작 기법과 사용 재료 등을 파악하기 위해서는 정밀한 과학적 분석이 필요하다. 본 연구에서는 부여 능산리사지에서 출토된 소조보살상을 대상으로 컴퓨터 단층촬영을 진행하고, 소조상의 제작 기법과 재료적 특징을 살펴보았다. 그 결과, 소조보살상은 얇은 나뭇가지 또는 갈대류 여러 개를 지푸라기 등으로 묶어 원통형으로 만든 심을 사용하여 제작하였음을 알 수 있었다. 또한 수비 과정을 거친 매우 고운 태토를 사용하였고, 태토의 내부에는 태토 간의 접착성을 높이고 수축 과정에서의 균열과 갈라짐을 방지하는 초본류가 존재했었던 흔적을 확인할 수 있었다. 한편, 입자가 고운 태토는 소조상의 내부와 외부의 밀도가 다르게 관찰되었는데, 이를 통해 소조보살상은 원통형의 심을 중심으로 태토를 접합하여 형태를 만들고 그 위에 다시 태토를 덧바른 다음, 세부 형태와 문양을 제작하였음을 알 수 있었다.

관상동맥 석회화 CT에서 측정한 대동맥 전개: 저위험 환자군에서의 정상 범위 (Aortic Unfolding Measurement Using Non-Contrast Cardiac CT: Normal Range of Low-Risk Subjects)

  • 이지원;최병욱
    • 대한영상의학회지
    • /
    • 제83권2호
    • /
    • pp.360-371
    • /
    • 2022
  • 목적 이 연구의 목적은 관상동맥 석회화 CT에서 측정한 대동맥 폭으로 정의한 대동맥 전개(aortic unfolding)에 영향을 미치는 요인을 평가하고 대동맥 전개의 정상 범위를 알아보는 것이다. 대상과 방법 이 후향적 연구에서 우리는 2015년 6월부터 2018년 6월까지 건강검진을 목적으로 관상동맥 석회화 CT를 시행 받은 924명의 무증상 성인에서 대동맥 전개를 측정했다. 다변량 회귀 분석을 사용하여 대동맥 전개에 영향을 미치는 요인들을 평가했다. 그 후 대동맥 전개와 관련된 위험 요소가 있는 성인을 제외되고 283명의 성인이 대동맥 전개의 정상값 분석에 포함되었다. 대동맥 전개의 평균, 표준 편차 및 상한값이 계산되었다. 결과 성별, 나이, 관상동맥 석회화 점수, 체질량지수, 체 표면적, 고혈압, 좌심실 비대, 혈장 크레아티닌, 흡연은 대동맥 전개와 유의한 관계가 있었다. 평균 대동맥 전개값은 남성의 경우 102.2 ± 12.8 mm, 여성의 경우 93.1 ± 10.7 mm였다. 대동맥 전개값은 연령이 증가할 수록(10년당 9.6 mm)으로 증가했다. 결론 관상동맥 석회화 CT에서 측정된 대동맥 전개는 심혈관 위험 인자들과 관련이 있었다. 또한 본 연구에서 저위험군에서 대동맥 전개의 정상 범위를 나이, 성별 및 체표표면적당으로 정의하였다.

Fully Automatic Coronary Calcium Score Software Empowered by Artificial Intelligence Technology: Validation Study Using Three CT Cohorts

  • June-Goo Lee;HeeSoo Kim;Heejun Kang;Hyun Jung Koo;Joon-Won Kang;Young-Hak Kim;Dong Hyun Yang
    • Korean Journal of Radiology
    • /
    • 제22권11호
    • /
    • pp.1764-1776
    • /
    • 2021
  • Objective: This study aimed to validate a deep learning-based fully automatic calcium scoring (coronary artery calcium [CAC]_auto) system using previously published cardiac computed tomography (CT) cohort data with the manually segmented coronary calcium scoring (CAC_hand) system as the reference standard. Materials and Methods: We developed the CAC_auto system using 100 co-registered, non-enhanced and contrast-enhanced CT scans. For the validation of the CAC_auto system, three previously published CT cohorts (n = 2985) were chosen to represent different clinical scenarios (i.e., 2647 asymptomatic, 220 symptomatic, 118 valve disease) and four CT models. The performance of the CAC_auto system in detecting coronary calcium was determined. The reliability of the system in measuring the Agatston score as compared with CAC_hand was also evaluated per vessel and per patient using intraclass correlation coefficients (ICCs) and Bland-Altman analysis. The agreement between CAC_auto and CAC_hand based on the cardiovascular risk stratification categories (Agatston score: 0, 1-10, 11-100, 101-400, > 400) was evaluated. Results: In 2985 patients, 6218 coronary calcium lesions were identified using CAC_hand. The per-lesion sensitivity and false-positive rate of the CAC_auto system in detecting coronary calcium were 93.3% (5800 of 6218) and 0.11 false-positive lesions per patient, respectively. The CAC_auto system, in measuring the Agatston score, yielded ICCs of 0.99 for all the vessels (left main 0.91, left anterior descending 0.99, left circumflex 0.96, right coronary 0.99). The limits of agreement between CAC_auto and CAC_hand were 1.6 ± 52.2. The linearly weighted kappa value for the Agatston score categorization was 0.94. The main causes of false-positive results were image noise (29.1%, 97/333 lesions), aortic wall calcification (25.5%, 85/333 lesions), and pericardial calcification (24.3%, 81/333 lesions). Conclusion: The atlas-based CAC_auto empowered by deep learning provided accurate calcium score measurement as compared with manual method and risk category classification, which could potentially streamline CAC imaging workflows.

Alternative Method of Retrocrural Approach during Celiac Plexus Block Using a Bent Tip Needle

  • An, Ji Won;Choi, Eun Kyeong;Park, Chol Hee;Choi, Jong Bum;Ko, Dong-Kyun;Lee, Youn-Woo
    • The Korean Journal of Pain
    • /
    • 제28권2호
    • /
    • pp.109-115
    • /
    • 2015
  • Background: This study sought to determine safe ranges of oblique angle, skin entry point and needle length by reviewing computed tomography (CT) scans and to evaluate the usefulness of a bent tip needle during celiac plexus block (CPB). Methods: CT scans of 60 CPB patients were reviewed. Image of the uppermost margin of L2 vertebral body was used to measure the minimal and maximal oblique angles and the distances from the midline to skin puncture point. The imaginary needle trajectory distance was calculated by three-dimensional measurement. When the procedure was performed by using a $10^{\circ}$ bent tip needle under a $20^{\circ}$ oblique X-ray fluoroscopic view, the distance (GF/G'F) from the midline to the actual puncture site was measured. Results: The imaginary safe oblique angle range was $26.4-34.2^{\circ}$ and $27.7-36.0^{\circ}$ on the right and left, respectively. The distance from the midline to skin puncture point was 6.1-7.6 cm on the right and 6.3-7.6 cm on the left. The needle trajectory distance at minimal angle was 9.6-11.6 cm on the right and 9.5-11.5 cm on the left. The distance of GF/G'F was 5.1-6.5 cm and 5.0-6.4 cm on the right and left, respectively. All imaginary parameters were correlated with BMI except for GF/G'F. All complications were mild and transient. Conclusions: We identified safe values of angles and distances using a straight needle. Furthermore, using a bent tip needle under a $20^{\circ}$ oblique fluoroscopic view, we could safely perform CPB with smaller parameter values.

29세 남자에서 다발성 낭종성 병변으로 진행한 폐선암 1예 (Adenocarcinoma of the Lung Progressing to Multiple Cystic Lesions in a 29-Year-Old Man)

  • 이현성;전재완;김재희;주형욱;배중기;민영주;안종준;서광원;제갈양진;권운정;차희정;나승원
    • Tuberculosis and Respiratory Diseases
    • /
    • 제72권2호
    • /
    • pp.203-206
    • /
    • 2012
  • Cystic lesions or progressive cystic changes in adenocarcinoma of the lung have rarely been reported. We report a case of lung adenocarcinoma that progressed from ground-glass opacities (GGOs) and consolidations or nodules to extensive cystic lesions during 12 months in a young adult patient. A 29-year-old male was initially diagnosed with primary lung adenocarcinoma by transbronchial lung biopsy of the right lower lobe and lung to lung metastasis in both lungs according to imaging findings. The initial chest computed tomography (CT) scans showed multifocal GGOs, consolidations, and nodules in both lungs. Despite treatment with palliative chemotherapy, the patient's follow-up CT scans showed multiple, cystic changes in both lungs and that the lesions had progressed more extensively. He died of hypoxic respiratory failure one year after his diagnosis.

3차원 콘빔CT 영상에서 형성한 2차원 정모두부방사선사진영상의 정확도 증진을 위한 두부자세재현기의 효과 (Use of Head Posture Aligner to improve accuracy of frontal cephalograms generated from cone-beam CT scans)

  • 선민규;엄기수;조진형;황현식
    • 대한치과교정학회지
    • /
    • 제39권5호
    • /
    • pp.289-299
    • /
    • 2009
  • 본 연구는 3차원 콘빔CT 영상을 이용하여 2차원 정모두부방사선사진영상 형성 시 두부자세재현기(Head Posture Aligner, HPA)를 이용한 경우와 이용하지 않은 경우를 비교분석함으로써 HPA의 유용성을 평가하기 위하여 시행되었다. 성인 30명을 대상으로 먼저 일반적인 방법으로 콘빔CT 영상을 채득한 후 HPA를 이용하여 일정한 두부자세를 재현한 상태에서 또 하나의 콘빔CT 영상 및 정모두부방사선사진을 촬영하였다. 3차원 영상프로그램을 이용하여 HPA를 이용하지 않은 경우와 HPA를 이용한 경우 각각에서 2차원 정모두부방사선사진영상을 형성한 다음 각각의 투사도를 작성하고 실제로 HPA를 이용하여 촬영된 정모두부방사선사진 투사도와의 차이를 비교하였다. 거리 및 각도를 나타내는 여러 계측치를 비교분석한 결과 HPA를 이용하지 않은 경우에는 다수의 계측항목에서 실제 정모두부방사선사진과 유의한 차이를 보인 반면 HPA를 이용한 경우에는 모든 항목에서 통계적 유의차를 보이지 않았다. 아울러 실제 정모두부방사선사진과의 상관관계를 알아보기 위해 상관분석을 시행한 결과 HPA를 이용한 경우가 그렇지 않은 경우보다 모든 항목에서 높은 상관성을 보였다. 본 연구 결과는 3차원 콘빔CT 영상을 이용하여 2차원 정모두부방사선사진영상 형성 시 정확한 영상 획득을 위해서는 콘빔CT 촬영 시 HPA의 사용이 필요함을 시사하였다.