• 제목/요약/키워드: CT Scans

검색결과 552건 처리시간 0.027초

Use of spherical coordinates to evaluate three-dimensional facial changes after orthognathic surgery

  • Yoon, Suk-Ja;Wang, Rui-Feng;Ryu, Sun-Youl;Hwang, Hyeon-Shik;Kang, Byung-Cheol;Lee, Jae-Seo;Palomo, Juan M.
    • Imaging Science in Dentistry
    • /
    • 제44권1호
    • /
    • pp.15-20
    • /
    • 2014
  • Purpose: This study aimed to assess the three-dimensional (3D) facial changes after orthognathic surgery by evaluating the spherical coordinates of facial lines using 3D computed tomography (CT). Materials and Methods: A 19-year-old girl was diagnosed with class III malocclusion and facial asymmetry. Orthognathic surgery was performed after orthodontic treatment. Facial CT scans were taken before and after orthognathic surgery. The patient had a menton deviation of 12.72 mm before surgery and 0.83 mm after surgery. The spherical coordinates of four bilateral facial lines (ramal height, ramal lateral, ramal posterior and mandibular body) were estimated from CT scans before and after surgery on the deviated and opposite side. Results: The spherical coordinates of all facial lines changed after orthognathic surgery. Moreover, the bilateral differences of all facial lines changed after surgery, and no bilateral differences were zero. Conclusion: The spherical coordinate system was useful to compare differences between the presurgical and postsurgical changes to facial lines.

CT 영상에서 결절성 폐암의 자동추출 및 체적계산 (Automated Detection and Volume Calculation of Nodular Lung Cancer on CT Scans)

  • 김도연;김진환;노승무;박종원
    • 한국정보과학회논문지:컴퓨팅의 실제 및 레터
    • /
    • 제7권5호
    • /
    • pp.451-457
    • /
    • 2001
  • 본 논문은 컴퓨터단층촬영 영상에서의 자동화된 결절성 폐암의 추출 및 체적계산을 수행하였다. 배경으로부터의 흉부 분리 및 흉부로부터 폐영역으로의 분리를 위해 명암값 임계치 방법이 사용되었고, 폐 경계선 주위에 위치하는 폐암을 폐영역으로 포함시키기 위해 스캔닝-볼(Scanning-Ball) 알고리즘을 사용하였다. 폐영역으로부터 높은 명암값을 가진 부분만을 추출하는데, 이는 폐암, 혈관 또는 부분볼륨중의 하나이다. 추출된 폐암 후보자중에서 폐암을 구별하기 위해 크기, 솔리드(Solid) 형태, 평균값, 표준편차, 픽셀의 빈돗수와 명암값과의 상관계수가 사용되었으며, 식별된 폐암의 체적 및 원형율을 계산하였으며, 이를 내림차순으로 분류하였다. 19개 케이스, 총 621개 영상에 적용한 결과, 95%의 폐암추출 민감도를 가진다.

  • PDF

Volumetric change of the latissimus dorsi muscle after immediate breast reconstruction with an extended latissimus dorsi musculocutaneous flap

  • Nam, Su Bong;Oh, Heung Chan;Choi, Jae Yeon;Bae, Seong Hwan;Choo, Ki Seok;Kim, Hyun Yul;Lee, Sang Hyup;Lee, Jae Woo
    • Archives of Plastic Surgery
    • /
    • 제46권2호
    • /
    • pp.135-139
    • /
    • 2019
  • Background In immediate breast reconstruction using an extended latissimus dorsi musculocutaneous (eLDMC) flap, the volume of the flap decreases, which causes a secondary deformity of the breast shape. Since little research has investigated this decrease in muscle volume, the authors conducted an objective study to characterize the decrease in muscle volume after breast reconstruction using an eLDMC flap. Methods Research was conducted from October 2011 to November 2016. The subjects included 23 patients who underwent mastectomy due to breast cancer, received immediate reconstruction using an eLDMC flap without any adjuvant chemotherapy or radiotherapy, and received a computed tomography (CT) scan from days 7 to 10 after surgery and 6 to 8 months postoperatively. In 10 patients, an additional CT scan was conducted 18 months postoperatively. Axial CT scans were utilized to measure the volumetric change of the latissimus dorsi muscle during the follow-up period. Results In the 23 patients, an average decrease of 54.5% was observed in the latissimus dorsi muscle volume between the images obtained immediately postoperatively and the scans obtained 6 to 8 months after surgery. Ten patients showed an average additional decrease of 11.9% from 6-8 months to 18 months after surgery. Conclusions We studied changes in the volume of the latissimus dorsi muscle after surgery using an eLDMC flap performed after a mastectomy without adjuvant chemotherapy or radiotherapy. In this study, we found that immediate breast reconstruction using a latissimus dorsi muscle flap led to a decrease in muscle volume of up to 50%.

PET/CT 검사에서 췌장암 판별을 위한 SUVm 경계값 연구 (Study of SUVm Cut-off Value for the Distinction of Pancreatic Cancer In PET/CT Exam)

  • 장보석;김재호;류궈쉬;장은성
    • 한국콘텐츠학회논문지
    • /
    • 제17권10호
    • /
    • pp.567-575
    • /
    • 2017
  • 본 연구는 PET/CT 장비로 $^{18}F--FDG$ 방사성 의약품 주입 후 60분에서 검출된 췌장질환자 60명의 SUVm 데이터 분포를 정규분포 화 시키는 가설을 설정하여 PET/CT 이중시간 검사에서 지연 검사 시행을 결정할 수 있는 기준으로 제시하였다. 비정규분포를 나타내는 SUVm 데이터를 BOX-COX 변환과 Johnson 변환을 통해 정규분포 화 하였다. 정규 분포 95% 신뢰구간 하단에서 지연검사를 결정할 수 있는 경계값 SUVm 2.52를 제시하였다. 통계적 검증을 통해 제안된 경계값은 췌장암 구별을 위한 지연시간 검사에서 (120분, 180분)두 실험군 모두 적용할 수 있는 유의한 상관관계를 보였으며, 통계적으로 유의하다(p<0.05). C-Value는 췌장암 군과 췌장염 군을 감별에서는 췌장암 판별에 통계적으로 유의하다 (p<0.01). C-Value graph를 이용해서 지연시간 120분 검사가 지연시간 180분 검사보다 유용성이 있음을 확인하였다. 경계값 SUVm 2.52를 기준으로 이중시간 검사를 결정했을 때, 현재 대다수의 핵의학과 개설병원에서 시행하고 있는 단일 시간 PET/CT 검사보다, 췌장암 조기 발견과 감별에 도움을 줄 수 있을 것으로 사료된다.

암환자 700예의 진단 및 치료 CT 이용율과 CT 확대장치 (The Availability of Diagnostic and Treatment Planning Computer in 700 Cancer Patients and Magnification Devices for CT)

  • 이귀원;박주선;한용문;윤세철;신경섭
    • 대한방사선치료학회지
    • /
    • 제2권1호
    • /
    • pp.81-85
    • /
    • 1987
  • It has been evident since 1972 that computed tomography(CT) can play an important role in treatment and managment of the cancer patients as four steps; diagnosis, satging Treatment and follow-up. In this paper, we intended to investigate the availability of CT scan and treatment planning computer in 700 cancer patients who have undergone radiation therapy at the division of radiation therapy, Kangnam St. Mary's Hospital, Catholic Medical College between Mar. 1983 and Dec. 1985. The result were as follow; 1. Of 700 irradiated cancer patients, 342 patients ($48.9\%$) were performed CT scan prior to radiation therapy. 2. The distribution of lesions in 342 patients having CT scans was like this; CNS (83 of 104 patients, $79.8\%$), abdomen (44 of 76 patients, $57.9\%$), pelvis (100 of 188 patients, $53.2\%$) etc. in order. 3. The treatment planning computer were used in 280 cancer patients ($40\%$). 4. Of the 280 cancer patients using treatment planning computer, 167 patients ($59.6\%$) applied diagnostic CT scan and remaining 113 patients ($40.4\%$) were made body contour to be used for radiation therapy planning by the treatment planning computer. Authors also made some magnification devices used for small multiformat CT images to magnify into life size, consisting of overhead projector (3M) I.V. stand and mirror. These enabled us to make less errors in tracing the small-sized CT images during input of the anatomical data into the treatment planning computer.

  • PDF

흉부 CT 스캔에서 재구성 알고리즘 변화적용 시 화질과 스캔 선량 분석 (Analysis of Image Quality and Scan Dose when Applying Reconstruction Algorithm Changes to Chest CT Scans)

  • 김현주
    • 한국방사선학회논문지
    • /
    • 제17권6호
    • /
    • pp.819-825
    • /
    • 2023
  • 흉부 CT 검사 조건 중 관전압을 100, 80 kVp, 재구성 알고리즘을 FBP, ASIR-V, DLIR로 변화 적용하여 검사 선량과 화질 변화를 비교 분석해 보았다. 그 결과 기존 관전압 보다 낮은 관전압인 100 kVp 에서 ASIR-V, DLIR 적용 시 선량을 낮추면서 120 kVp, FBP 적용 시와 가장 유사한 화질로 구현. 특히, DLIR 재구성 영상은 모든 관전압에서 SNR, CNR이 우수하였다. 또한, SSIM 지수가 1에 가장 근사하게 분석되어 원본 영상과 가장 유사도가 높은 것을 알 수 있었다. 따라서 반복적으로 흉부 CT 검사를 시행하는 경우 DLIR 적용은 검사 선량을 약 29.7% 감소시킬 수 있어 CT 검사의 가장 큰 문제점인 검사로 인한 피폭을 일부 해결하는 데 도움을 줄 수 있을 것으로 사료된다.

CT-Based Fagotti Scoring System for Non-Invasive Prediction of Cytoreduction Surgery Outcome in Patients with Advanced Ovarian Cancer

  • Na Young Kim;Dae Chul Jung;Jung Yun Lee;Kyung Hwa Han;Young Taik Oh
    • Korean Journal of Radiology
    • /
    • 제22권9호
    • /
    • pp.1481-1489
    • /
    • 2021
  • Objective: To construct a CT-based Fagotti scoring system by analyzing the correlations between laparoscopic findings and CT features in patients with advanced ovarian cancer. Materials and Methods: This retrospective cohort study included patients diagnosed with stage III/IV ovarian cancer who underwent diagnostic laparoscopy and debulking surgery between January 2010 and June 2018. Two radiologists independently reviewed preoperative CT scans and assessed ten CT features known as predictors of suboptimal cytoreduction. Correlation analysis between ten CT features and seven laparoscopic parameters based on the Fagotti scoring system was performed using Spearman's correlation. Variable selection and model construction were performed by logistic regression with the least absolute shrinkage and selection operator method using a predictive index value (PIV) ≥ 8 as an indicator of suboptimal cytoreduction. The final CT-based scoring system was internally validated using 5-fold cross-validation. Results: A total of 157 patients (median age, 56 years; range, 27-79 years) were evaluated. Among 120 (76.4%) patients with a PIV ≥ 8, 105 patients received neoadjuvant chemotherapy followed by interval debulking surgery, and the optimal cytoreduction rate was 90.5% (95 of 105). Among 37 (23.6%) patients with PIV < 8, 29 patients underwent primary debulking surgery, and the optimal cytoreduction rate was 93.1% (27 of 29). CT features showing significant correlations with PIV ≥ 8 were mesenteric involvement, gastro-transverse mesocolon-splenic space involvement, diaphragmatic involvement, and para-aortic lymphadenopathy. The area under the receiver operating curve of the final model for prediction of PIV ≥ 8 was 0.72 (95% confidence interval: 0.62-0.82). Conclusion: Central tumor burden and upper abdominal spread features on preoperative CT were identified as distinct predictive factors for high PIV on diagnostic laparoscopy. The CT-based PIV prediction model might be useful for patient stratification before cytoreduction surgery for advanced ovarian cancer.

이중시간 PET/CT 검사에서 췌장암 판별을 위한 최적의 Scan time 분석 (Optimal Scan time Analysis for Pancreatic Cancer Distinction in Dual time PET-CT Exam)

  • 장보석
    • 한국방사선학회논문지
    • /
    • 제13권2호
    • /
    • pp.305-311
    • /
    • 2019
  • 본 연구에서는 이중 시간 PET/CT 검사에서 지연검사 시간이 다른 두 그룹의 40명의 췌장암 환자에 대한 SUV 데이터의 통계 분석을 통해 최적의 지연검사 시간을 제시하였다. 췌장암의 유무를 확인해야 될 이중 시간 PET/CT 검사에서 새로운 수학적 예측 모델을 만들어 정확도 높은 최적의 지연검사 시간을 제시하였다. 시간에 따른 포도당 대사를 적용한 방사능 붕괴식을 예측 모델로 제시하였다. 지연검사 시간이 다른 두 그룹의 데이터를 가지고 시뮬레이션한 결과 PET/CT에서 췌장암 판별을 위한 최적의 지연검사 시간이 131.5분으로 제시하였다. 제안된 지연검사 시간은 췌장암 결정에 적용될 수 있는 통계적 유의 수준을 보였다(p<0.05). 제안된 지연 검사 시간 131.5분을 결정하여 검사를 진행할 때, 췌장암 조기 판별에 도움을 줄 수 있을 것으로 사료된다.

Effects of Implementing Artificial Intelligence-Based Computer-Aided Detection for Chest Radiographs in Daily Practice on the Rate of Referral to Chest Computed Tomography in Pulmonology Outpatient Clinic

  • Wonju Hong;Eui Jin Hwang;Chang Min Park;Jin Mo Goo
    • Korean Journal of Radiology
    • /
    • 제24권9호
    • /
    • pp.890-902
    • /
    • 2023
  • Objective: The clinical impact of artificial intelligence-based computer-aided detection (AI-CAD) beyond diagnostic accuracy remains uncertain. We aimed to investigate the influence of the clinical implementation of AI-CAD for chest radiograph (CR) interpretation in daily practice on the rate of referral for chest computed tomography (CT). Materials and Methods: AI-CAD was implemented in clinical practice at the Seoul National University Hospital. CRs obtained from patients who visited the pulmonology outpatient clinics before (January-December 2019) and after (January-December 2020) implementation were included in this study. After implementation, the referring pulmonologist requested CRs with or without AI-CAD analysis. We conducted multivariable logistic regression analyses to evaluate the associations between using AI-CAD and the following study outcomes: the rate of chest CT referral, defined as request and actual acquisition of chest CT within 30 days after CR acquisition, and the CT referral rates separately for subsequent positive and negative CT results. Multivariable analyses included various covariates such as patient age and sex, time of CR acquisition (before versus after AI-CAD implementation), referring pulmonologist, nature of the CR examination (baseline versus follow-up examination), and radiology reports presence at the time of the pulmonology visit. Results: A total of 28546 CRs from 14565 patients (mean age: 67 years; 7130 males) and 25888 CRs from 12929 patients (mean age: 67 years; 6435 males) before and after AI-CAD implementation were included. The use of AI-CAD was independently associated with increased chest CT referrals (odds ratio [OR], 1.33; P = 0.008) and referrals with subsequent negative chest CT results (OR, 1.46; P = 0.005). Meanwhile, referrals with positive chest CT results were not significantly associated with AI-CAD use (OR, 1.08; P = 0.647). Conclusion: The use of AI-CAD for CR interpretation in pulmonology outpatients was independently associated with an increased frequency of overall referrals for chest CT scans and referrals with subsequent negative results.

PET/CT 저선량 적용 시 CT 감쇠보정법에 따른 피폭선량 저감효과 (Effect of the Dose Reduction Applied Low Dose for PET/CT According to CT Attenuation Correction Method)

  • 정승우;김홍균;권재범;박성욱;김명준;신영만;김영헌
    • 핵의학기술
    • /
    • 제18권1호
    • /
    • pp.127-133
    • /
    • 2014
  • PET/CT에서 환자피폭 문제로 인해 저 선량의 중요성이 강조되고 있다. 본 연구에서는 기존에 사용되던 CT 데이터를 이용한 감쇠보정법인 CTAC와 새롭게 적용된 Q.AC를 환자실험과 팬텀 실험을 통해 저 선량으로 촬영 시 PET 영상에 미치는 영향에 대해 알아보고자 한다. 실험장비는 GE사의 PET/CT Discovery 710 (GE Healthcare, USA)를 사용하였으며 팬텀실험으로 감쇠보정의 정량적 평가를 위한 NEMA IEC body phantom과 균일성 평가를 위한 Uniform NU2-94 phantom을 사용하였다. 각각의 팬텀 내부에 동위원소 18-F FDG를 70.78 MBq, 22.2 MBq 주입하고 CT조건은 저 선량조건으로 80 kVp, 10 mA로부터 일반선량 조건으로 140 kVp, 120 mA 조건까지 스캔 후 CTAC와 Q.AC 두 감쇠보정법을 적용하여 재구성하였다. PET 영상에서 일반선량 조건을 기준값으로 정하고 horizomtal profile과 vertical profile을 통해 정량평가를 시행하고 기준값과의 상대적 오차를 평가하였다. 또한 환자실험으로 정상체중 환자와 과체중 환자를 구분하여 저 선량과 일반선량으로 비교 촬영한 뒤 CTAC와 Q.AC로 재구성된 PET영상에서 주요장기별 SUV에 대한 상대적 오차와 신호 대 잡음비를 비교분석하였다. 팬텀실험 결과 저선량 조건에서 CTAC와 Q.AC로 각각 재구성한 PET 영상의 profile과 상대적 오차에서 CTAC보다 Q.AC가 기준값과의 오차가 적은 그래프를 얻었다. 환자실험의 경우 일반선량 조건에서는 정상체중 환자와 과체중 환자 모두 감쇠보정법에 따른 상대적 오차값의 변화가 적었으나 저 선량 조건에서는 정상체중 환자보다 과체중 환자에서 감쇠보정법의 변경에 의한 상대적 오차의 감소폭이 커짐으로 기준값과 차이가 감소하였다. 기존의 감쇠보정법인 CTAC는 80 kVp, 10 mA의 저선량 CT를 사용하는데 있어 PET 영상의 선속경화현상이 발생한다. 이로 인해 CTAC를 이용하여 재구성된 PET 데이터는 정량화하는데 문제가 될 수 있음을 확인했다. 반면에 새로운 알고리즘이 적용된 Q.AC는 과체중 환자의 경우 80 kVp, 10 mA 정도까지는 140 kVp, 120 mA 조건으로 촬영하여 재구성한 PET 데이터 결과와 차이가 적음을 확인할 수 있었다. Q.AC를 이용한 경우 기존보다 저 선량의 CT를 이용해 PET의 재구성에 이용할 수 있으므로 환자의 피폭을 줄이는 데 큰 역할을 할 것으로 기대한다.

  • PDF