• Title/Summary/Keyword: CT Scans

Search Result 552, Processing Time 0.026 seconds

A Study on the Dose Reduction Method for Temporal Bone HRCT Scan (관자뼈 HRCT 스캔 시 선량감소 방법에 관한 연구)

  • Joon Yoon;Hyeon-Ju Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.7
    • /
    • pp.1041-1047
    • /
    • 2023
  • Temporal bone CT, which is a high-resolution CT, uses a high tube voltage and a thin section thickness, so the scan dose is higher than that of adjacent areas. Accordingly, we applied changes to the reconstruction algorithm among the test conditions to find an algorithm with excellent sensitivity to lesions while reducing the test dose, and investigated its significance and the possibility of providing basic clinical data. As a result, when the tube voltage was lowered to 100 kVp and applied, the dose was reduced by about 35.6%, and when the definition algorithm was applied to the raw data acquired at 100 kVp, the SNR and CNR were excellent, and a statistically significant difference was shown when compared to other algorithms(p<0.05). And as a result of comparing structural similarity, the SSIM index was analyzed as 0.776, 0.813, and 0.741 for each ROI. Therefore, we believe that applying algorithm changes to temporal bone CT scans can partially reduce the dose generated from CT scans and are very meaningful in terms of basic clinical data.

Radiographic study of the distribution of maxillary intraosseous vascular canal in Koreans

  • Lee, JuHyon;Kang, Nara;Moon, Young-Mi;Pang, Eun-Kyoung
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.38
    • /
    • pp.1.1-1.4
    • /
    • 2016
  • Background: This study aimed to investigate the distribution and prevalence of intraosseous loop (anastomosis between posterior superior alveolar artery and infraorbital artery) in Koreans detected on computed tomography (CT) images taken prior to sinus augmentation surgery. Methods: From the 177 patients who underwent sinus augmentation with lateral approach at Ewha Womans University Department of Implant Dentistry, 284 CT scans were evaluated. The canal height (CH), ridge height (RH), and canal height from the sinus floor (CHS) were measured on para-axial views at the first premolar, first molar, and second molar. The horizontal positions of the bony canals in the lateral wall were also classified. One-way analysis of variance (ANOVA) and t test were used to estimate the statistical differences (p < 0.05). Results: The intraosseous loops were detected in 92 CT scans (32 %). The mean vertical height of the bony canals from the alveolar crest (CH) was $23.45{\pm}2.81$, $15.92{\pm}2.65$, and $16.61{\pm}2.92mm$ at the second premolar, first molar, and second molar, respectively. In the horizontal positions of the bony canals, intraosseous type was the most predominant. The canal heights more than 15 mm and less than 17 mm were most prevalent (33.7 %) and those under 13 mm were 12.0 %. Conclusions: The radiographic findings in this study could be used to decide the lateral osteotomy line avoiding potential vascular complication. However, only one third of the canals could be detected in CT scans; a precaution should be taken for the possibility of severe bleeding during lateral osteotomy.

Evaluation of Merkel Cell Carcinoma Metastasis Using Positron Emission Topography/CT (양전자방출단층촬영술(PET/CT)을 이용한 메르켈 세포암(Merkel cell carcinoma)의 전이 평가)

  • Kwon, Soon Hong;Song, Jin Kyung;Yoo, Gyeol;Byeon, Jun Hee
    • Archives of Plastic Surgery
    • /
    • v.33 no.2
    • /
    • pp.233-236
    • /
    • 2006
  • Merkel cell carcinoma is rare skin malignancy originated from epidermal mechanoreceptor of neural origin. The tumor usually affects older individuals at sun exposed area such as head, neck and extremity. Subclinical involvement of regional lymph node is reported frequently at the time of initial treatment. Thus even asymptomatic patients who present with clinically localized tumor should undergo evaluation with computed tomography and lymphangiography. Positron emission tomography(PET) scans can imaging the metabolic difference of malignant tumors. Increased glucose uptake of malignant tumor cells are detected by PET scanner. PET scans can provide qualitative and quantitative informations about systemic metastasis of tumors. Although there are no data that define the efficacy of PET scans in the initial diagnostic evaluation of head and neck cancer, they could be considered. Current standards of treatment of Merkel cell carcinoma is wide surgical excision and regional lymphadenectomy if there are suspicious lymph nodes. The author reported a patient with Merkel cell carcinoma of cheek. Wide surgical excision and postoperative PET/CT was done for evaluation of regional lymph node and distant metastasis. There were two hot-uptakes in patient's neck, so they were considered as metastatic node, but finally they were proved to be tuberculosis lymphadenitis after excision.

The Relationship between Facial Fractures and Radiologically-proven Cranial Injuries (안면부 골절과 전산화 단층 촬영으로 진단된 두부 손상의 연관성)

  • Song, Jin Woo;Jo, Ik Joon;Han, Sang Kook;Jeong, Yeon Kwon
    • Journal of Trauma and Injury
    • /
    • v.22 no.1
    • /
    • pp.18-23
    • /
    • 2009
  • Purpose: In this study, we retrospectively investigated the medical records of patients with facial fractures and suspected cranial injuries in order to determine if there was any relationship between various facial fracture patterns and cranial injuries. Methods: Medical records were reviewed to identify patients diagnosed with facial fractures who underwent cranial computed tomography (CT) scans. Records were reviewed for gender, age, injury mechanism, facial fracture pattern, and presence or absence of cranial injuries. Facial fracture patterns were classified as isolated fractures (tripod, zygomatic arch, maxilla, orbit, and mandible), combined fractures, or total fractures. Cranial injuries included skull fractures, traumatic subarachnoid hemorrhages, subdural hemorrhages, epidural hemorrhages, and contusional hemorrhages. All cranial injuries were established by using cranial CT scans, and these kinds of cranial injuries were defined radiologically-proven cranial injuries (RPCIs). We evaluated the relationship between each pattern of facial fractures and the incidence of RPCIs. Results: Of 132 eligible patients with facial fractures who underwent cranial CT scans, a total of 27 (20.5%) patients had RPCIs associated with facial fractures. Falls and slips were the most common causes of the fractures (31.8%), followed by assaults and motor vehicle accidents (MVAs). One hundred one (76.5%) patients had isolated facial fractures, and 31 (23.5%) patients had combined facial fractures. Fractures were found most commonly in the orbital and maxillary bones. Patients with isolated maxillary fractures had a lower incidence of RPCIs than those with total mandibular fractures. RPCIs frequently accompanied combined facial fractures. Conclusion: Combined facial fractures had a significant positive correlation with RPCIs. This means that facial fractures caused by stronger or multidirectional external force are likely to be accompanied by cranial injuries.

Efficacy of CT-aided Radiotherapy Planning of Head and Neck Tumor (두경부악성종양(頭頸部惡性腫瘍)의 방사선치료계획(放射線治療計劃)에 있어서 전산화단층촬영(電算花斷層撮影)의 이용(利用)에 관(關)한 연구(硏究))

  • Cho, Chul Koo;Koh, Kyoung Hwan;Chang, Kee Hyun;Park, Charn Il
    • Radiation Oncology Journal
    • /
    • v.1 no.1
    • /
    • pp.47-53
    • /
    • 1983
  • CT scans obtained on 15 patients of head and neck malignant tumors were evaluated for their utility in ratiotherapy treatment planning. To evaluate the advantage of incorporating CT scans in radiotherapy treatment planning of head and neck malignant tumors, the dose distributions of treatment plan with and without CT scan were compared in 15 patients. And then the dose distributions of the first and second treatment plan were compared. 1. Tumor extend and localization were clearly delineated on CT scan in 12 of 15 cases (80%), suggestive in 2 (13.3%), and not seen in only one (6.7%) which had been in the postoperative state. 2. Tumor coverage after CT scan was adequate in 14 of 15 cases (93.3%) and not in only one. In one case of inadequate tumor coverage the target volume lay inside the field but reached within 0.5cm of the field margin (marginal miss). 3. The volume of normal tissue irradiated was reduced after CT scan in 12 of 15 cases (80%), increased in 1 (6.7%) and not changed in 2 (13.3%). 4. We could maximize the local control of disease and minimize unnecessary morbidity by delineating the location and extent of tumor and normal tissue with CT for treatment plannings.

  • PDF

Nonrigid Lung Registration between End-Exhale and End-Inhale CT Scans Using a Demon Algorithm (데몬 알고리즘을 이용한 호기-흡기 CT 영상 비강체 폐 정합)

  • Yim, Ye-Ny;Hong, Helen;Shin, Yeong-Gil
    • Journal of KIISE:Software and Applications
    • /
    • v.37 no.1
    • /
    • pp.9-18
    • /
    • 2010
  • This paper proposes a deformable registration method using a demon algorithm for aligning the lungs between end-exhale and end-inhale CT scans. The lungs are globally aligned by affine transformation and locally deformed by a demon algorithm. The use of floating gradient force allows a fast convergence in the lung regions with a weak gradient of the reference image. The active-cell-based demon algorithm helps to accelerate the registration process and reduce the probability of deformation folding because it avoids unnecessary computation of the displacement for well-matched lung regions. The performance of the proposed method was evaluated through comparisons of methods that use a reference gradient force or a combined gradient force as well as methods with and without active cells. The results show that the proposed method can accurately register lungs with large deformations and can reduce the processing time considerably.

Automatic Detection of Kidney Tumor from Abdominal CT Scans (복부 CT 영상에서 신장암의 자동추출)

  • 김도연;노승무;조준식;김종철;박종원
    • Journal of KIISE:Software and Applications
    • /
    • v.29 no.11
    • /
    • pp.803-808
    • /
    • 2002
  • This paper describes automatic methods for detection of kidney and kidney tumor on abdominal CT scans. The abdominal CT images were digitalized using a film digitizer and a gray-level threshold method was used to segment the kidney. Based on texture analysis results, which were perform on sample images of kidney tumors, SEED region of kidney tumor was selected as result of homogeneity test. The average and standard deviation, which are representative statistical moments, were used to as an acceptance criteria for homogeneous test. Region growing method was used to segment the kidney tumor from the center pixel of selected SEED region using a gray-level value as an acceptance criteria for homogeneity test. These method were applied to 113 images of 9 cases, which were scanned by GE Hispeed Advantage CT scanner and digitalized by Lumisvs LS-40 film digitizer. The sensitivity was 85% and there was no false-positive results.

USEFULNESS OF $^{18}F$-FDG PET/CT IN THE EVALUATION OF CERVICAL LYMPH NODE METASTASIS IN PATIENTS WITH ORAL CANCER (구강암 환자에서 $^{18}F$ FDG-PET/CT의 경부 림프절 전이 평가 유용성)

  • Yu, Min-Gi;Ryu, Sun-Youl
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.35 no.4
    • /
    • pp.213-220
    • /
    • 2009
  • Purpose: The present study was aimed to examine the usefulness of 18F-FDG PET/CT in the evaluation of cervical lymph node metastasis in patients with oral cancer. Materials and methods: Twenty-two patients who underwent neck dissection to treat oral cancer were subjected for examination. The cervical node metastasis was evaluated by means of clinical examination, CT scan, PET, and histologic examination. By comparing the results of each examination modality with those of histologic examination, it's sensitivity, specificity, positive predictive value, and negative predictive value were determined. Results: The oral cancer was more frequent in males with a ratio of 2.14:1. The sixth decade showed the highest incidence in age distribution with mean of $56{\pm}16$. Histologic findings showed that squamous cell carcinoma was the most common (15 patients), and mucoepidermoid carcinoma (3), malignant melanoma (2), and adenoid cystic carcinoma and ghost cell odontogenic carcinoma (1 each), in order. In most cases, wide surgical excision of the primary cancer and neck dissection was performed, followed by reconstruction with free flaps when necessary. When comparing the results of each examination modality with those of the histologic examination, clinical examination showed sensitivity, specificity, positive predictive value, and negative predictive value at 11%, 85%, 33%, and 58%, respectively. CT scans showed at 67%, 77%, 67%, and 77%, while $^{18}F$-FDG PET/CT at 78%, 77%, 70%, and 83%, respectively. Conclusions: These results suggest that PET is more useful, compared with clinical examination and CT scans, in the evaluation of cervical lymph node metastasis in patients with oral cancer.

The Study of Effectiveness of Volume Mode in Pediatric CT (소아 전산화단층촬영에서 Volume Mode의 유용성 연구)

  • Park, Yun;Kim, Sang-Hyun
    • Journal of Digital Convergence
    • /
    • v.12 no.10
    • /
    • pp.425-431
    • /
    • 2014
  • The purpose of this study is to analyze dose comparison and image quality evaluation according to Volume and Helical mode using ATOM Phantom. It is to actively use the Volume mode in pediatric CT examinations. There was no significant difference with Helical and Volume in the value of Noise, HU, SNR(p>0.05). All dose values was no statistical difference(p>0.05). In the value of DLP and effective dose by part, Volume mode was measured lower than Helical mode. For qualitative analysis, by scan parameter helical mode showed respectively 2.6, 3.3, 4.36 and Volume mode indicated 2.8, 3.64, 4.44 point. Image evaluation for the follow-up, Helical mode and Volume mode were respectively 3.8 and 3.83. In fact, There was no significant difference. In CT scans in children under 5 years, because 640-MDCT Volume scan dose compared with Helical mode is lower and there is no significant difference with two modes in the image quality, 640-MDCT Volume scan is thought to be useful for pediatric CT scans.

Measurement of Radiation Dose of HR CT and Low Dose CT by using Anthropomorphic Chest Phantom and Glass Dosimetry (인체등가형 흉부팬텀과 유리선량계를 이용한 고해상력 및 저선량 CT의 선량측정)

  • Kweon, Dae Cheol
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.7
    • /
    • pp.933-939
    • /
    • 2019
  • The purpose of this study is to provide basic clinical data by evaluating images, measuring absorbed dose and effective dose by using high resolution CT and low dose CT by using anthropomorphic chest phantom and glass dosimeter. Tissue dose was measured by inserting a glass dosimeter into the anthropomorphic chest phantom. A 64-slice CT system (SOMATOM Sensation 64, Siemens AG, Forchheim, Germany) and CARE Dose 4D were used, and the parameters of the high resolution CT were 120 kVp, Eff. Scan parameters of mAs 104, scan time 7.93 s, slice 1.0 mm (Acq. 64 × 0.6 mm), convolution kernel (B60f sharp) were used, and low dose CT was 120 kVp, Eff. mAs 15, scan time 7.41 s, slice 3.0 mm (Acq. 64 × 0.6 mm), scan of convolution kernel B50f medium sharp. CTDIvol was measured at 8.01 mGy for high resolution CT and 1.18 mGy for low dose CT. Low dose CT scans showed 85.49% less absorbed dose than high resolution CT scans.