• 제목/요약/키워드: CT Scanning

검색결과 372건 처리시간 0.256초

Dependency of Generator Performance on T1 and T2 weights of the Input MR Images in developing a CycleGan based CT image generator from MR images (CycleGan 딥러닝기반 인공CT영상 생성성능에 대한 입력 MR영상의 T1 및 T2 가중방식의 영향)

  • Samuel Lee;Jonghun Jeong;Jinyoung Kim;Yeon Soo Lee
    • Journal of the Korean Society of Radiology
    • /
    • 제18권1호
    • /
    • pp.37-44
    • /
    • 2024
  • Even though MR can reveal excellent soft-tissue contrast and functional information, CT is also required for electron density information for accurate dose calculation in Radiotherapy. For the fusion of MRI and CT images in RT treatment planning workflow, patients are normally scanned on both MRI and CT imaging modalities. Recently deep-learning-based generations of CT images from MR images became possible owing to machine learning technology. This eliminated CT scanning work. This study implemented a CycleGan deep-learning-based CT image generation from MR images. Three CT generators whose learning is based on T1- , T2- , or T1-&T2-weighted MR images were created, respectively. We found that the T1-weighted MR image-based generator can generate better than other CT generators when T1-weighted MR images are input. In contrast, a T2-weighted MR image-based generator can generate better than other CT generators do when T2-weighted MR images are input. The results say that the CT generator from MR images is just outside the practical clinics and the specific weight MR image-based machine-learning generator can generate better CT images than other sequence MR image-based generators do.

Computed tomography investigation of the three-dimensional structure and production method of White Porcelain Water Dropper with Openwork Lotus Scroll Design and Eight Trigram Design in Cobalt-blue Underglaze (CT 조사를 통한 청화백자투각연당 초팔괘문연적의 3차원적 구조와 제작방법에 대한 고찰)

  • Na, Ahyoung;Hwang, Hyunsung
    • Conservation Science in Museum
    • /
    • 제25권
    • /
    • pp.1-8
    • /
    • 2021
  • This study investigated White Porcelain Water Dropper with Openwork Lotus Scroll Design and Eight Trigram Design in Cobalt-blue Underglaze (hereinafter, the "water dropper") in the collection of the National Museum of Korea using computed tomography (CT). A replica was produced to examine both the structure and its original production method. The CT scanning identified no joint lines or pores in the clay, which suggests that the body (the lower part of the water dropper) was shaped in a single piece using a mold and was then matched with a mold-formed lid (the upper part of the water dropper). The inner container of the body portion was roughly trimmed with a bamboo knife so that its upper surface could be securely attached to the bottom of the lid and prevent any leakage in the joined surface. It appears that the inner container for storing water was made first in a cylindrical shape that met the unit of quantity used at the time and could be easily formed by molding. It was transformed into a trapezoid shape during the process of combining it with the lid. A cylindrical inner container was reproduced using silicon 3D printing to compare its capacity with that of the original inner container. The comparison revealed that the reproduced container had a capacity of 152.5㎖, whereas the original container holds approximately 168.6㎖, a figure similar to three hop (around 174㎖) in Joseon-period units of quantity. Since the capacity of the cylindrical inner container corresponds to a known measure from the late Joseon dynasty, it is likely that the water dropper was originally produced to contain a cylindrical inner container.

Development of X-ray Micro Computed Tomography and Applications (미세 X선 단층촬영 기법의 개발과 적용)

  • Kim, Seung-Gon;Lim, Jae-Hong;Kim, Bo-Heum;Lee, Eui-Jae;Lee, Sang-Joon
    • Journal of the Korean Society of Visualization
    • /
    • 제8권2호
    • /
    • pp.45-50
    • /
    • 2010
  • The objective of this study is to elucidate the feasibility of synchrotron X-ray micro CT as a non-destructive imaging method to visualize the three-dimensional morphological structures of biological and non-biological samples. The experiments were conducted in 7B2 X-ray micro CT beamline in Pohang Accelerate Laboratory (PAL). A rotational 3-axis stage was specially designed for $0^{\circ}-180^{\circ}$ scanning of test samples. Preliminary tests were performed for opaque samples including a mosquito head, a plant seed and gas diffusion layer (GDL) of polymer electrolyte fuel cell to verify the feasibility of the X-ray micro CT. It visualized clearly the internal structure of all the test samples, supporting its usefulness.

Usefulness of CTF guided PTBD in ER patients with obstructive jaundice (응급실로 내원한 폐쇄성 황달 환자에서 CT Fluoroscopy 유도 PTBD의 유용성)

  • Park Hyoo Soon;Bea Suk Hwan;Jung Chang Min;KO Kyung Nam;Park Yeon Tae
    • Journal of The Korean Radiological Technologist Association
    • /
    • 제29권1호
    • /
    • pp.31-34
    • /
    • 2003
  • Purpose : To evaluate technical feasibility and clinical usefulness of CT fluoroscopy (CTF) guided PTBD immediately after CT scanning in ER Patients with obstructive jaundice. Materials and Method : ER patients diagnose4 as obstructive jaundice through cl

  • PDF

An Iterative Image Reconstruction Method for the Region-of-Interest CT Assisted from Exterior Projection Data (Exterior 투영데이터를 이용한 Region-of-Interest CT의 반복적 영상재구성 방법)

  • Jin, Seung Oh;Kwon, Oh-Kyong
    • Journal of Biomedical Engineering Research
    • /
    • 제35권5호
    • /
    • pp.132-141
    • /
    • 2014
  • In an ordinary CT scan, a large number of projections with full field-of-view (FFOV) are necessary to reconstruct high resolution images. However, excessive x-ray dosage is a great concern in FFOV scan. Region-of-interest (ROI) CT or sparse-view CT is considered to be a solution to reduce x-ray dosage in CT scanning, but it suffers from bright-band artifacts or streak artifacts giving contrast anomaly in the reconstructed image. In this study, we propose an image reconstruction method to eliminate the bright-band artifacts and the streak artifacts simultaneously. In addition to the ROI scan for the interior projection data with relatively high sampling rate in the view direction, we get sparse-view exterior projection data with much lower sampling rate. Then, we reconstruct images by solving a constrained total variation (TV) minimization problem for the interior projection data, which is assisted by the exterior projection data in the compressed sensing (CS) framework. For the interior image reconstruction assisted by the exterior projection data, we implemented the proposed method which enforces dual data fidelity terms and a TV term. The proposed method has effectively suppressed the bright-band artifacts around the ROI boundary and the streak artifacts in the ROI image. We expect the proposed method can be used for low-dose CT scans based on limited x-ray exposure to a small ROI in the human body.

Thin-Section CT Findings of Arc-Welders' Pneumoconiosis

  • Daehee Han;Jin Mo Goo;Jung-Gi Im;Kyung Soo Lee;Do Myung Paek;Seong Ho Park
    • Korean Journal of Radiology
    • /
    • 제1권2호
    • /
    • pp.79-83
    • /
    • 2000
  • Objective: To describe the thin-section CT findings of arc-welders' pneumoconiosis. Materials and Methods: Eighty-five arc-welders with a three to 30 (mean, 15)-year history of exposure underwent thin-section CT scanning. The extent of abnormalities detected was correlated with the severity of dyspnea and pulmonary function tests. For comparison, images of 43 smoking males (mean 25 pack-year) who underwent thin-section CT for other reasons (smokers' group) were also analyzed. Results: Fifty-four welders (63.5%) and six smokers (14.0%) showed positive findings. Predominant thin-section CT findings were poorly-defined centrilobular micronodules (30/54, 55.6%), branching linear structure (18/54, 33.3%), and ground-glass attenuation (6/54, 11.1%). In the smokers' group, poorly-defined micronodules were found in four patients, branching linear structures in one, and ground-glass attenuation in one. In welders, the extent of abnormalities seen on thin-section CT showed no significant correlation with the severity of dyspnea or the results of pulmonary funotion test. Conclusion: Poorly-defined centrilobular micronodules and branching linear structures were the thin-section CT findings most frequently seen in patients with arc-welders' pneumoconiosis. Less commonly, extensive ground-glass attenuation was also seen.

  • PDF

Application of Low-Dose CT for Screening of Lung Disease (폐질환의 선별검사를 위한 저선량 전산화 단층촬영의 적용)

  • Lee, Won-Jeong;Choi, Byung-Soon;Park, Young-Sun;Seon, Jong-Ryul;Bae, Seok-Hwan
    • Journal of radiological science and technology
    • /
    • 제32권2호
    • /
    • pp.129-140
    • /
    • 2009
  • As CT has been increasingly used as an accurate screening tool for lung disease, radiation dose becomes an important issue for both radiographers and patients. Many researches have been done for a low-dose CT as a screening tool for early detection of asymptomatic lung diseases. From those studies, it has been reported that chest dose rate from the low-dose CT is considerably lower than from standard CT. The patient dose is determined by scanning parameters such as kVp, mAs, pitch, scan time and the radiation risk of lung in screening examination may not be negligible. Herein, we suggest that Low-dose CT is useful as a screening tool in routine clinical practice on the basis of published articles, but further study is necessary because Low-dose CT has poor sensitivity and specificity for screening early stage of lung cancer according to the results of the studies. This article is to provide a brief overview of the screening examinations by Low-dose CT.

  • PDF

In vitro evaluation methods on adaptation of fixed dental prosthesis (고정성 보철물의 적합도에 대한 실험적 평가방법)

  • Lee, Hyunho;Lee, Du-Hyeong;Lee, Kyu-Bok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • 제33권2호
    • /
    • pp.63-70
    • /
    • 2017
  • Clinically, the fit of fixed prosthesis is an essential element for successful restoration. The fit of prosthesis is largely classified into marginal fit and internal fit, and various methods to assess these have been introduced including microscopic margin measurement, cross-sectional measurement, silicone replica technique, 3-dimensional scanning data superposition, weight technique and micro CT scanning. Thus, this study is aimed at proposing a more convenient and accurate measurement method of fits in a digital environment by comparatively analyzing the advantages and disadvantages of each known method based on existing literature.

The Effect of Hyaluronate-Carboxymethyl Cellulose on Bone Graft Substitute Healing in a Rat Spinal Fusion Model

  • Lee, Jung-Hee;Jeong, Bi-O
    • Journal of Korean Neurosurgical Society
    • /
    • 제50권5호
    • /
    • pp.409-414
    • /
    • 2011
  • Objective : The aim of this study was to evaluate the impact of sodium hyaluronate-sodium carboxymethyl cellulose (HA-CMC), an anti-adhesive material for spinal surgery, on bone fusion by applying it to rat spinal models after lumbar posterolateral fusion. Methods : Lumbar posterolateral fusion was performed at L4-5 using bone graft substitutes in 30 rats. HA-CMC was injected in 15 rats at a dose of 0.2 cc (HA-CMC group) and a saline solution of 0.2 cc in the other 15 rats (control group). Simple radiographs were taken until postoperative 9 weeks with an interval of one week. At postoperative 4 and 9 weeks, three dimensional computed tomography (3D CT) scanning was performed to observe the process of bone fusion. At 9 weeks, bone fusion was confirmed by gross examination and manual palpation. Results : There were no statistically significant differences in bone fusion between the two groups. 3D CT scanning did not reveal significant differences between the groups. The gross examination and manual palpation after autopsy performed at 9 weeks confirmed bone union in 93.3% of both groups. Conclusion : The anti-adhesive material used for spinal surgery did not have adverse effects on spinal fusion in rats.

The Effect of PET/CT Images on SUV with the Correction of CT Image by Using Contrast Media (PET/CT 영상에서 조영제를 이용한 CT 영상의 보정(Correction)에 따른 표준화섭취계수(SUV)의 영향)

  • Ahn, Sha-Ron;Park, Hoon-Hee;Park, Min-Soo;Lee, Seung-Jae;Oh, Shin-Hyun;Lim, Han-Sang;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • 제13권1호
    • /
    • pp.77-81
    • /
    • 2009
  • Purpose: The PET of the PET/CT (Positron Emission Tomography/Computed Tomography) quantitatively shows the biological and chemical information of the body, but has limitation of presenting the clear anatomic structure. Thus combining the PET with CT, it is not only possible to offer the higher resolution but also effectively shorten the scanning time and reduce the noises by using CT data in attenuation correction. And because, at the CT scanning, the contrast media makes it easy to determine a exact range of the lesion and distinguish the normal organs, there is a certain increase in the use of it. However, in the case of using the contrast media, it affects semi-quantitative measures of the PET/CT images. In this study, therefore, we will be to establish the reliability of the SUV (Standardized Uptake Value) with CT data correction so that it can help more accurate diagnosis. Materials and Methods: In this experiment, a total of 30 people are targeted - age range: from 27 to 72, average age : 49.6 - and DSTe (General Electric Healthcare, Milwaukee, MI, USA) is used for equipment. $^{18}F$- FDG 370~555 MBq is injected into the subjects depending on their weight and, after about 60 minutes of their stable position, a whole-body scan is taken. The CT scan is set to 140 kV and 210 mA, and the injected amount of the contrast media is 2 cc per 1 kg of the patients' weight. With the raw data from the scan, we obtain a image showing the effect of the contrast media through the attenuation correction by both of the corrected and uncorrected CT data. Then we mark out ROI (Region of Interest) in each area to measure SUV and analyze the difference. Results: According to the analysis, the SUV is decreased in the liver and heart which have more bloodstream than the others, because of the contrast media correction. On the other hand, there is no difference in the lungs. Conclusions: Whereas the CT scan images with the contrast media from the PET/CT increase the contrast of the targeted region for the test so that it can improve efficiency of diagnosis, there occurred an increase of SUV, a semi-quantitative analytical method. In this research, we measure the variation of SUV through the correction of the influence of contrast media and compare the differences. As we revise the SUV which is increasing in the image with attenuation correction by using contrast media, we can expect anatomical images of high-resolution. Furthermore, it is considered that through this trusted semi-quantitative method, it will definitely enhance the diagnostic value.

  • PDF