• Title/Summary/Keyword: CT Images

Search Result 1,782, Processing Time 0.028 seconds

Accuracy Verification of Optical Tracking System for the Maxillary Displacement Estimation by Using of Triangulation (삼각측량기법을 이용한 광학추적장치의 상악골 변위 계측에 대한 정확성 검증)

  • Kyung, Kyu-Young;Kim, Soung-Min;Lee, Jong-Ho;Myoung, Hoon;Kim, Myung-Jin
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.34 no.1
    • /
    • pp.41-52
    • /
    • 2012
  • Purpose: Triangulation is the process of determining the location of a point by measuring angles to it from known points at either end of a fixed baseline. This point can be fixed as the third point of a triangle with one known side and two known angles. The aim of this study was to find a clinically adaptable method for applying an optical tracking navigation system to orthognathic surgery and to estimate its accuracy of measuring the bone displacement by use of triangulation methods. Methods: In orthognathic surgery, the head position is not fixed as in neurosurgery, so that a head tracker is needed to establish the reference point on the head surface byusing an optical tracking system. However, the operation field is interfered by its bulkiness that makes its clinical use difficult. To solve this problem, we designed a method using an Aquaplast splinting material and a mini-screw in applying a head tracker on a patient's forehead. After that, we estimated the accuracy of measuring displacements of the ball marker by an optical tracking system with a conventional head tracker (Group A) and with a newly designed head tracker (Group B). Measured values of ball markers' displacements by each optical tracking system were compared with values obtained from fusion CT images for an estimation of accuracy. Results: The accuracy of the optical tracking system with a conventional head tracker (Group A) is not suitable for clinical usage. Measured and predictable errors are larger than 10 mm. The optical tracking system with a newly designed head tracker (Group B) shows 1.59 mm, 6.34 mm, and 9.52 mm errorsin threeclinical cases. Conclusion: Most errors were brought on mainly from a lack of reproducibility of the head tracker position. The accuracy of the optical tracking system with a newly designed head tracker can be a useful method in further orthognathic navigation surgery even though the average error is higher than 2.0 mm.

The incidence and configuration of the bifid mandibular canal in Koreans by using cone-beam computed tomography

  • Kang, Ju-Han;Lee, Kook-Sun;Oh, Min-Gyu;Choi, Hwa-Young;Lee, Sae-Rom;Oh, Song-Hee;Choi, Yoon-Joo;Kim, Gyu-Tae;Choi, Yong-Suk;Hwang, Eui-Hwan
    • Imaging Science in Dentistry
    • /
    • v.44 no.1
    • /
    • pp.53-60
    • /
    • 2014
  • Purpose: This study was performed to investigate the incidence and configuration of the bifid mandibular canal in a Korean population by using cone-beam computed tomography (CBCT) imaging. Materials and Methods: CBCT images of 1933 patients (884 male and 1049 female) were evaluated using PSR-9000N and Alphard-Vega 3030 Dental CT units (Asahi Roentgen Ind. Co., Ltd, Kyoto, Japan). Image analysis was performed by using OnDemand3D software (CyberMed Inc., Seoul, Korea). The bifid mandibular canal was identified and classified into four types, namely, the forward canal, buccolingual canal, dental canal, and retromolar canal. Statistical analysis was performed by using the chi-squared test and one-way analysis of variance (ANOVA). Results: Bifid mandibular canals were observed in 198 (10.2%) of 1933 patients. The most frequently observed type of bifid mandibular canal was the retromolar canal (n=104, rate: 52.5%) without any significant difference among the incidence of each age and gender. The mean diameter of the accessory canal was 1.27 mm (range: 0.27-3.29 mm) without any significant difference among the mean diameter of each type of the bifid mandibular canal. The mean length of the bifid mandibular canals was 14.97mm(range: 2.17-38.8 mm) with only a significant difference between the dental canal and the other types. Conclusion: The bifid mandibular canal is not uncommon in Koreans and has a prevalence of 10.2% as indicated in the present study. It is suggested that a CBCT examination be recommended for detecting a bifid canal.

Reconstruction of body contour with digital camera image (Digital Camera의 영상을 이용한 신체 단면도 제작)

  • Kwon, KT;Kim, CM;Kang, TY;Park, CS;Song, HK
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.15 no.1
    • /
    • pp.53-60
    • /
    • 2003
  • I. Purpose It is essential to have the correct body contour information for the calculation of dose distribution. The role of CT images in the radiation oncology field has been increased. But there still exists a method to use cast or lead wire for the body contour drawing. This traditional method has drawbacks such as in accurate and time consuming procedure. This study has been designed to overcome this problem. II. Materials and Methods A digital camera is attached to a pole which stands on the opposite side of the gantry. Positional information was acquired from an image of the phantom which is specially designed for this study and located on the isocenter level of the simulator Laser line on the patients skin or on the phantom surface was digitized and reconstructed as the contour. Verification of usefulness this technique has been done with various shape of phantoms and a patients chest III. Results and Conclusions Contours from the traditional method with the cast or lead wire and the digital image method showed good agreement within experimetal error range. This technique showed more efficiente in time and convenience. For irregular shaped contour, like H&N region, special care are needed. The results suggest that more study is needed. To use of the another photogrammatory techinique with two camera system may be better for the actual clinical application

  • PDF

Needle Decompression for Trauma Patients: Chest Wall Thickness and Size of the Needle (외상 환자에 대한 바늘감압술에서 흉벽 두께와 바늘 길이의 관계)

  • Kim, Jee-Wan;Jeong, Jin-Woo;Cho, Suck-Ju;Yeom, Seok-Ran;Han, Sang-Kyoon;Park, Sung-Wook
    • Journal of Trauma and Injury
    • /
    • v.23 no.2
    • /
    • pp.63-67
    • /
    • 2010
  • Purpose: A tension pneumothorax is a fatal condition that requires immediate intervention. Although a definitive treatment for a tension pneumothorax is a tube thoracostomy, needle decompression can provide temporary relief, that is lifesaving. The traditional procedure for needle decompression involves inserting a needle or catheter at the second intercostal space, the midclavicular line. Recent evidence suggests that the commonly used catheters do not have sufficiently penetrate the chest wall. There are also claims that a lateral approach to needle decompression is easier and safer than the traditional anterior approach. The purpose of this study is to evaluate the optimal approach for needle decompression for the Korean population by measuring chest wall thicknesses at the points used for both the anterior and the lateral approaches. Methods: The chest wall thickness (CWT) of trauma victims who visited the Emergency Center of Pusan National University Hospital was measured by computed tomography (CT) images. The CWT was measured at the points used for the anterior and the lateral methods and was compared with the length of commonly used catheters, which is 45 mm. Results: The mean CWT at the second intercostal space, the midclavicular line, was shorter than the CWT at the 5th intercostal space, the anterior axillary line. However, the percentage of patients whose CWT was greater than 45 mm was larger when measured anteriorly (8.2%) that when measure laterally (5.7%). Female patients and those older than 60 were more likely to have an anterior CWT greater than 45 mm (28.2% for females and 15.5% for those older than 60). Conclusion: The percentage of trauma victims in Korea whose CWT is greater than 45 mm is lower than the values previously reported by other countries. However, females and older patients tend to have thicker chest walls, so the lateral approach would be suggested when performing needle decompression for such patients with suspected tension pneumothoraces.

The Objective Measurement of the Lung Parenchyma Motion for Planning Target Volume Delineation (폐 부위 Planning Target Volume(PTV)설정시 폐 움직임의 객관적 측정)

  • Chung, Weon-Kyu;Cho, Jeong-Gill
    • Radiation Oncology Journal
    • /
    • v.15 no.4
    • /
    • pp.387-392
    • /
    • 1997
  • Purpose : To quantify the movement of lung Parenchyma for ICRU 50 Planning Target Volume (PTV) delineation of the lung region. Materials and Method : Fluoroscopic observations and measurements are Performed on 10 patients with chest region cancer who have normal putmonary functions We have divided the lung region into 12 parts for the right lung, 10 parts for the left lung and four to five Points of lung parenchyma were selected for anatomical analysis Points, Fluoroscopic images are sent to a computer and then movements are measured. Results : Both lowe lobes showed the longest longitudinal movements because of breathing (average 14.1mm, maximum 22.1mm), while anteroposterior displacement showed the smallest value. Lateral movements of the lung parenchyma averaged 6.6mm, and the maximum value was 9.1mm, (both hilar regions showed maximum values because of cardiac motion) Conclusion : We could quantify the lung movements by measuring parenchyma displacements. The movements of both upper lobes were less than those of the middle and upper lobes in longitudinal and transverse movements. Optimal margins can be selected for PTV delineation using these results.

  • PDF

Serial $^{99m}Tc$-HMPAO Brain SPECT for Assessing Perfusion Improvement after EDAS in Moyamoya Patients (모야모야병에서 EDAS 수술효과의 평가를 위한 수술전후 $^{99m}Tc$-HMPAO SPECT의 유용성)

  • Lee, Kyung-Han;Lee, Sang-Hyung;Yeo, Jeong-Seok;Kwark, Chul-Eun;Chung, June-Key;Lee, Myoung-Chul;Cho, Byoung-Kyu;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.28 no.1
    • /
    • pp.22-30
    • /
    • 1994
  • Encephalo-duro-arterio-synangiosis (EDAS) is a relatively new surgical procedure for treatment of childhood moyamoya disease. We assessed regional cerebral perfusion in moyamoya patients before (1.3 mo) and after (6.8 mo) EDAS with $^{99m}Tc$-HMPAO brain SPECT. A total of 21 EDAS operations in 17 moyamoya patients was included. Preoperative CT or MRI showed cerebral infarction in 14 patients and carotid angiography showed Suzuki grade I to V stenosis in 6%, 9%, 62%, 12% and 12% of the hemispheres respectively. Preoperative SPECT showed regional hypoperfusion in all patients, bilateral frontal and temporal lobes being the most frequently involved site. $4{\times}4$ pixel sized ROIs were applied on the frontotemporal cortex in 3 slice averaged transverse tomographic images. An index of regional perfusion was measured as: PI (%)=average F-T activity/average cerebellar activity${\times}100$ Pre-EDAS ipsilateral PI ranged from 23.7 to 98.4% (mean: $74.3{\pm}17%$) and increased significantly after operation ($81.4{\pm}17%$, p<0.001). Individual post-EDAS PI improved in 15/21 cases, showed no significant change in 5 and was slightly aggravated in 1. The amount of clinical improvement (${\Delta}CI$) was graded with a scale of 0 to 4 based on frequency and severity of TIA attacks. When patients were grouped according to pre-EDAS PI, group II (PI 70-89) showed a significantly higher ${\Delta}CI$ (3.3) compared to group I (PI< 70, 1.57) or group III (PI >90, 0.5) (P< 0.001). The amount of perfusion improvement (${\Delta}PI$) showed significant correlation with ${\Delta}CI$ (r=0.42, p=0.04). ${\Delta}PI$ did not, however, correlate with the amount of neovascularization assessed angiographically in 8 patients. Serial HMPAO SPECT is an useful noninvasive study for assessing perfusion improvement after EDAS in childhood moyamoya patients.

  • PDF

The Evaluation of Clinical Usefulness on Application of Half-Time Acquisition Factor in Gated Cardiac Blood Pool Scan (게이트심장혈액풀 스캔에서 Half-Time 획득 인자 적용에 따른 임상적 유용성 평가)

  • Lee, Dong-Hun;Yoo, Hee-Jae;Lee, Jong-Hun;Jung, Woo-Young
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.3
    • /
    • pp.192-198
    • /
    • 2008
  • Purpose: The scan time reduction helps to yield more accurate results and induce the minimization of patient's motion. Also we can expect that satisfaction of examination will increase. Nowdays medical equipment companies have developed various programs to reduce scan time. We used Onco. Flash (Pixon method, SIEMENS) that is an image processing technique gated cardiac blood pool scan and going to evaluate its clinical usefullness. Materials and Method: We analyzed the 50 patients who were examined by gated blood pool scan in nuclear medicine department of Asan Mediacal Center from June $20^{th}$ 2008 to August $14^{th}$ 2008. We acquired the Full-time (6000 Kcounts) and Half-time (3000 Kcounts) LAO image in same position. And we acquired LVEF values ten times from Full-time, Half-time images acquired by the image processing technique and analyzed its mean and standard deviation values. To estimate LVEF in same conditions, we set automatic location of the LV ROI and background ROI based on same X and Y-axis. Also we performed blinding tests to physician. Results: After making a quantitative analysis of the 50 patients EF values, each mean${\pm}$standard deviation is shown at Full-time image $68.12{\pm}7.84%$, Half- time (acquired by imaging processing technique) $68.49{\pm}8.73%$. In the 95% confidence limit, there was no statistically significant difference (p>0.05). After blinding test with a physician for making a qualitative analysis, there was no difference between Full-time image and Half-time image acquired by the image processing technique for observing LV myocardial wall motion. Conclusion: Gated cardiac blood pool scan has been reported its relatively exact EF measured results than ultrasound or CT. But gated cardiac blood pool scan takes relatively longer time than other exams and now it needs to improve time competitive power. If we adapt Half-time technique to gated cardiac blood pool scintigraphy based on this study, we expect to reduce possible artifacts and improve accessibility as well as flexibility to exam. Also we expect patient's satisfaction.

  • PDF

Ultrasounds Image on the Disorders of the Ligaments Surrounding Temporomandibular Joints (측두하악관절 주변인대 질환의 초음파영상)

  • Hong, Soo-Min;Im, Yeong-Gwan;Kim, Byung-Gook
    • Journal of Oral Medicine and Pain
    • /
    • v.33 no.4
    • /
    • pp.387-394
    • /
    • 2008
  • Purpose : The purpose of this study was to verify the usefulness and feasibility of ultrasonographic imaging for the detection of the disorders of the surrounding supporting structure such as articular capsule, retrodiscal tissue and related ligaments, osteoarthritic evidence and associated disc displacement at the temporomandibular joint(TMJ) Materials and Methods : 20 patients(40 joints) with periodic lock and crepitations were investigated prospectively using 12 MHz array transducer. Ultrasonographic Imagings were assessed for osteoarthritic surface changes of condyle, extent of disc displacement and disorders of surrounding structures. Ultrasonographic images were compared with clinical investigations, conventional radiography and Dental Computed Tomographic scans. Results : In clinical and conventional radiography, osteoarthritic changes were diagnosed in 8 joints. Ultrasonographically 7 of the 8 osteoarthritic changes were diagnosed correctly. Sensitivity, specificity, and accuracy of ultrasonography in the osteoarthritic detections were 87.5%, 62.5%, and 67.5% respectively. About the detection of disc displacement, disc displacement were diagnosed in 21 joints clinically. Ultrasonographically 19 of the 21 disc displacements were diagnosed correctly. Sensitivity, specificity, and accuracy of ultrasonography in the osteoarthritic detections were 95%, 90%, and 92.5% respectively. when the disorders of supportive structure were figured out, the disorders of supportive structure were diagnosed in 18 joints clinically. Ultrasonographically 1 of the 18 the disorders of supportive structure were diagnosed correctly. Sensitivity, specificity, and accuracy of ultrasonography in the osteoarthritic detections were 5.5%, 4.5%, and 55% respectively. Conclusion : Ultrasonography is an relatively reliable diagnostic tool for the detection of disc displacement and some of osteoarthritic changes. But it's not an insufficient imaging technique for the detection of the disorders of the surrounding structure.

Cross-sectional study of the mandibular body in patients with facial asymmetry (안면 비대칭환자의 하악골체부의 시상 단면에 관한 연구)

  • Lee, Jae-Yeo;Kim, Yong-Il;Hwang, Dae-Seok;Kim, Yong-Deok;Shin, Sang-Hun;Kim, Uk-Kyu;Chung, In-Kyo
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.37 no.2
    • /
    • pp.109-113
    • /
    • 2011
  • Introduction: To correct the facial asymmetry by mandibular jaw surgery, it is important to know the anatomy of the mandible including the mandibular canal positioning of patients with facial asymmetry. This study was performed to evaluate the differences in the cross-sectional surface in the body of the mandible between the deviated side and opposite side in patients with facial asymmetry. Materials and Methods: The study was conducted on 37 adult patients composed of 2 groups, the asymmetry group (n=20) and non-asymmetry group (n=17). Using the cross-sectional computed tomography (CT) images, the distance from the buccal aspect of the mandibular canal to the outer aspect of the buccal cortex, distance from the buccal aspect of the mandibular canal to the inner aspect of the buccal cortex, distance from the inferior aspect of the mandibular canal to the inferior border of the mandible, thickness of the mandible, and cross-sectional surface area of the mandible were measured in each side of the mandible Results: The cross-sectional area of the mandible including the mandibular canal positioning in the deviated side was not statistically different from the opposite side in the asymmetry group. Only the distance from the inferior aspect of the mandibular canal to the inferior border of the mandible in the ramus area of the deviated side was significantly longer than opposite side. On the other hand, the bucco-lingual width of the asymmetry group was thinner than the non-asymmetry group. Conclusion: The cross-sectional area including the mandibular canal of the mandible did not appear to be modified by the facial asymmetry.

Image Quality of a Rotating Compton Camera Evaluated by Using 4-D Monte Carlo Simulation Technique (4-D 전산모사 기법을 이용한 호전형 컴프턴 카메라의 영상 특성 평가)

  • Seo, Hee;Lee, Se-Hyung;Park, Jin-Hyung;Kim, Chan-Hyeong;Park, Sung-Ho;Lee, Ju-Hahn;Lee, Chun-Sik;Lee, Jae-Sung
    • Journal of Radiation Protection and Research
    • /
    • v.34 no.3
    • /
    • pp.107-114
    • /
    • 2009
  • A Compton camera, which is based on Compton kinematics, is a very promising gamma-ray imaging device in that it could overcome the limitations of the conventional gamma-ray imaging devices. In the present study, the image quality of a rotating Compton camera was evaluated by using 4-D Monte Carlo simulation technique and the applicability to nuclear industrial applications was examined. It was found that Compton images were significantly improved when the Compton camera rotates around a gamma-ray source. It was also found that the 3-D imaging capability of a Compton camera could enable us to accurately determine the 3-D location of radioactive contamination in a concrete wall for decommissioning purpose of nuclear facilities. The 4-D Monte Carlo simulation technique, which was applied to the Compton camera fields for the first time, could be also used to model the time-dependent geometry for various applications.