• Title/Summary/Keyword: CT Images

Search Result 1,782, Processing Time 0.034 seconds

An Experimental Study on Fundamental Properties of a Sprayable Waterproofing Membrane (뿜칠 방수 멤브레인 시작품의 기초 물성평가)

  • Chang, Soo-Ho;Kang, Tae-Ho;Choi, Soon-Wook;Lee, Chulho;Hwang, Gwi-Sung;Choi, Myung-Sik
    • Tunnel and Underground Space
    • /
    • v.26 no.3
    • /
    • pp.220-234
    • /
    • 2016
  • Sprayable waterproofing membrane has been considered as a substitute for a sheet waterproofing membrane in a variety of underground excavation works. However, fundamental properties of sprayble waterproofing membrane have not been fully given yet. In this study, a new two-component sprayable waterproofing membrane prototype was developed. In addition, its physico-mechanical properties were measured and compared with those of two kinds of thin spray-on liners where constitutive materials and construction methods are very close to each other. From direct tensile tests, the sprayable waterproofing membrane with elongations at break between 250% and 300% showed much higher ductility than TSLs. However, the sprayable waterproofing membrane had a limitation as a support member since its bond strength and loading capacity was lower than those of TSLs. From three-dimensional X-ray CT images, the porosity of the sprayable waterproofing membrane was estimated to be 26.13%. However, most of pores which might have been generated during membrane curing were not observed to be interconnected but isolated.

Three Dimensional Measurement of Ideal Trajectory of Pedicle Screws of Subaxial Cervical Spine Using the Algorithm Could Be Applied for Robotic Screw Insertion

  • Huh, Jisoon;Hyun, Jae Hwan;Park, Hyeong Geon;Kwak, Ho-Young
    • Journal of Korean Neurosurgical Society
    • /
    • v.62 no.4
    • /
    • pp.376-381
    • /
    • 2019
  • Objective : To define optimal method that calculate the safe direction of cervical pedicle screw placement using computed tomography (CT) image based three dimensional (3D) cortical shell model of human cervical spine. Methods : Cortical shell model of cervical spine from C3 to C6 was made after segmentation of in vivo CT image data of 44 volunteers. Three dimensional Cartesian coordinate of all points constituting surface of whole vertebra, bilateral pedicle and posterior wall were acquired. The ideal trajectory of pedicle screw insertion was defined as viewing direction at which the inner area of pedicle become largest when we see through the biconcave tubular pedicle. The ideal trajectory of 352 pedicles (eight pedicles for each of 44 subjects) were calculated using custom made program and were changed from global coordinate to local coordinate according to the three dimensional position of posterior wall of each vertebral body. The transverse and sagittal angle of trajectory were defined as the angle between ideal trajectory line and perpendicular line of posterior wall in the horizontal and sagittal plane. The averages and standard deviations of all measurements were calculated. Results : The average transverse angles were $50.60^{\circ}{\pm}6.22^{\circ}$ at C3, $51.42^{\circ}{\pm}7.44^{\circ}$ at C4, $47.79^{\circ}{\pm}7.61^{\circ}$ at C5, and $41.24^{\circ}{\pm}7.76^{\circ}$ at C6. The transverse angle becomes more steep from C3 to C6. The mean sagittal angles were $9.72^{\circ}{\pm}6.73^{\circ}$ downward at C3, $5.09^{\circ}{\pm}6.39^{\circ}$ downward at C4, $0.08^{\circ}{\pm}6.06^{\circ}$ downward at C5, and $1.67^{\circ}{\pm}6.06^{\circ}$ upward at C6. The sagittal angle changes from caudad to cephalad from C3 to C6. Conclusion : The absolute values of transverse and sagittal angle in our study were not same but the trend of changes were similar to previous studies. Because we know 3D address of all points constituting cortical shell of cervical vertebrae. we can easily reconstruct 3D model and manage it freely using computer program. More creative measurement of morphological characteristics could be carried out than direct inspection of raw bone. Furthermore this concept of measurement could be used for the computing program of automated robotic screw insertion.

A Discussion on Image Analysis in 18F-Florbetaben PET/CT (18F-Florbetaben PET/CT 검사에서 영상분석에 대한 고찰)

  • Choi, Yong-Hoon;Bahn, Young-Kag;Lim, Han-Sang;Kim, Jae-Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.26 no.1
    • /
    • pp.33-37
    • /
    • 2022
  • Purpose 18F-Florbetaben (FBB) Readings are made by visually comparing the signal strengths of gray matter and white matter. We intend to evaluate the usefulness of image analysis by comparing quantified image analysis with readout. Materials and Methods Based on the reading results, 100 patients were divided into a negative scan and a positive scan, and 300 MBq of FBB was injected, and images were taken 90 minutes later for 20 minutes. The equipment was a Discovery 600 (GE Healthcare, MI, USA). Four regions of interest (lateral temporal lobes, frontal lobes, posterior cingulate & precuneus, and parietal lobes) were established based on the amyloid reading standard provided by the manufacturer. For image analysis, SUVratio (SUVr) was calculated by dividing each SUVmean by the cerebellum, and the average SUVr in the entire area was performed. Statistical analysis analyzed the cutoff derivation through ROC Curve, the difference between groups in Independent sample t-test, and the degree of agreement with the reading result through Kappa test. Results The average SUVr cutoff in the entire area was 1.23. Concordance with the read results using cutoff was 95/100 (95%) for negative and 92/100 (92%) for positive. As a result of the t-test, there was a statistically significant difference between the groups (P < 0.05), and the Kappa statistical result showed a high degree of agreement with 0.867 (P < 0.05). Conclusion The results of image analysis were statistically significant and showed a high degree of agreement with the reading results. In addition, FBB image analysis can be viewed by 3D mapping the area where amyloid is accumulated, location estimation is possible, and quantitative analysis results can be viewed in detail. If quantified FBB image analysis is used as an auxiliary indicator, it is thought to be helpful in reading.

Fe3O4 magnetic nanoparticles provide a novel alternative strategy for Staphylococcus aureus bone infection

  • Youliang, Ren;Jin, Yang;Jinghui, Zhang;Xiao, Yang;Lei, Shi;Dajing, Guo;Yuanyi, Zheng;Haitao, Ran;Zhongliang, Deng;Lei, Chu
    • Advances in nano research
    • /
    • v.13 no.6
    • /
    • pp.575-585
    • /
    • 2022
  • Due to its biofilm formation and colonization of the osteocyte-lacuno canalicular network (OLCN), Staphylococcus aureus (S.aureus) implant-associated bone infection (SIABI) is difficult to cure thoroughly, and may occur recurrently subsequently after a long period dormant. It is essential to explore an alternative therapeutic strategy that can eradicate the pathogens in the infected foci. To address this, the polymethylmethacrylate (PMMA) bone cement and Fe3O4 nanoparticles compound cylinder were developed as implants based on their size and mechanical properties for the alternative magnetic field (AMF) induced thermal ablation, The PMMA mixed with optimized 2% Fe3O4 nanoparticles showed an excellent antibacterial efficacy in vitro. It was evaluated by the CFU, CT scan and histopathological staining on a rabbit 1-stage transtibial screw model. The results showed that on week 7, the CFU of infected soft tissue and implants, and the white blood cells (WBCs) of the PMMA+2% Fe3O4+AMF group decreased significantly from their controls (p<0.05). PMMA+2% Fe3O4+AMF group did not observe bone resorption, periosteal reaction, and infectious reactive bone formation by CT images. Further histopathological H&E and Gram Staining confirmed there was no obvious inflammatory cell infiltration, neither pathogens residue nor noticeably burn damage around the infected screw channel in the PMMA+2% Fe3O4+AMF group. Further investigation of nanoparticle distributions in bone marrow medullary and vital organs of heart, liver, spleen, lung, and kidney. There were no significantly extra Fe3O4 nanoparticles were observed in the medullary cavity and all vital organs either. In the current study, PMMA+2% Fe3O4+AMF shows promising therapeutic potential for SIABI by providing excellent mechanical support, and promising efficacy of eradicating the residual pathogenic bacteria in bone infected lesions.

Comparison of CT Volumetry and RECIST to Predict the Treatment Response and Overall Survival in Gastric Cancer Liver Metastases (위암 간전이 환자의 반응평가와 생존율 예측을 위한 종양 부피 측정과 RECIST 기준의 비교 연구)

  • Sung Hyun Yu;Seung Joon Choi;HeeYeon Noh;In seon Lee;So Hyun Park; Se Jong Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.4
    • /
    • pp.876-888
    • /
    • 2021
  • Purpose The aim of this study was to compare the diameter and volume of liver metastases on CT images in relation to overall survival and tumor response in patients with gastric cancer liver metastases (GCLM) treated with chemotherapy. Materials and Methods We recruited 43 patients with GCLM who underwent chemotherapy as a first-line treatment. We performed a three-dimensional quantification of the metastases for each patient. An independent survival analysis using the Response Evaluation Criteria in Solid Tumors (RECIST) was performed and compared to volumetric measurements. Overall survival was evaluated using Kaplan-Meier analysis and compared using Cox proportional hazard ratios following univariate analyses. Results When patients were classified as responders or non-responders based on volumetric criteria, the median overall survival was 23.6 months [95% confidence interval (CI), 8.63-38.57] and 7.6 months (95% CI, 3.78-11.42), respectively (p = 0.039). The volumetric analysis and RECIST of the non-progressing and progressing groups showed similar results based on the Kaplan-Meier method (p = 0.006) and the Cox proportional hazard model (p = 0.008). Conclusion Volumetric assessment of liver metastases could be an alternative predictor of overall survival for patients with GCLM treated with chemotherapy.

Does Nasal Septal Deviation and Concha Bullosa Have Effect on Maxillary Sinus Volume and Maxillary Sinusitis?: A Retrospective Study (비중격 만곡증과 수포성 비갑개는 상악동 부피와 상악골 부비동염에 있어 관련성을 지니는가?: 후향적 연구)

  • Juyeon Lee;Sang Man Park;Seung-Whan Cha;Jin Sil Moon;Myung Soon Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.81 no.6
    • /
    • pp.1377-1388
    • /
    • 2020
  • Purpose This study aimed to determine whether nasal septal deviation and concha bullosa affect the maxillary sinus volume, and whether this effect is associated with the prevalence of chronic sinusitis. Materials and Methods This study retrospectively reviewed 209 paranasal sinus CT (PNS CT) images of patients with sinonasal symptoms from January 2017 to December 2018. The maxillary sinus volume was measured twice by a radiologist, and statistical analysis was performed using SAS 9.4. Results Intersex comparison of the maxillary sinus volume (on left and right sides) revealed that the volume was significantly larger on both the sides (p < 0.0001) in men compared with that in women. Concha bullosa was found to occur mainly in the concave cavity of the septal deviation (p < 0.0001). No significant association was found between nasal septal deviation and maxillary sinusitis (p = 0.8756) as well as between concha bullosa and maxillary sinusitis prevalence (p = 0.3401) or maxillary sinus volume (both: p = 0.6289, Rt.: p = 0.9522, Lt.: p = 0.9201). Conclusion Although nasal septal deviation and the location of concha bullosa may affect each other, maxillary sinus volume and maxillary sinusitis were neither associated with nasal septal deviation nor concha bullosa.

Radiologic assessment of the optimal point for tube thoracostomy using the sternum as a landmark: a computed tomography-based analysis

  • Jaeik Jang;Jae-Hyug Woo;Mina Lee;Woo Sung Choi;Yong Su Lim;Jin Seong Cho;Jae Ho Jang;Jea Yeon Choi;Sung Youl Hyun
    • Journal of Trauma and Injury
    • /
    • v.37 no.1
    • /
    • pp.37-47
    • /
    • 2024
  • Purpose: This study aimed at developing a novel tube thoracostomy technique using the sternum, a fixed anatomical structure, as an indicator to reduce the possibility of incorrect chest tube positioning and complications in patients with chest trauma. Methods: This retrospective study analyzed the data of 184 patients with chest trauma who were aged ≥18 years, visited a single regional trauma center in Korea between April and June 2022, and underwent chest computed tomography (CT) with their arms down. The conventional gold standard, 5th intercostal space (ICS) method, was compared to the lower 1/2, 1/3, and 1/4 of the sternum method by analyzing CT images. Results: When virtual tube thoracostomy routes were drawn at the mid-axillary line at the 5th ICS level, 150 patients (81.5%) on the right side and 179 patients (97.3%) on the left did not pass the diaphragm. However, at the lower 1/2 of the sternum level, 171 patients (92.9%, P<0.001) on the right and 182 patients (98.9%, P= 0.250) on the left did not pass the diaphragm. At the 5th ICS level, 129 patients (70.1%) on the right and 156 patients (84.8%) on the left were located in the safety zone and did not pass the diaphragm. Alternatively, at the lower 1/2, 1/3, and 1/4 of the sternum level, 139 (75.5%, P=0.185), 49 (26.6%, P<0.001), and 10 (5.4%, P<0.001), respectively, on the right, and 146 (79.3%, P=0.041), 69 (37.5%, P<0.001), and 16 (8.7%, P<0.001) on the left were located in the safety zone and did not pass the diaphragm. Compared to the conventional 5th ICS method, the sternum 1/2 method had a safety zone prediction sensitivity of 90.0% to 90.7%, and 97.3% to 100% sensitivity for not passing the diaphragm. Conclusions: Using the sternum length as a tube thoracostomy indicator might be feasible.

Preoperative estimation of hemi-liver volume using standard liver volume and portal vein diameter ratio in living donor liver transplantation

  • Sung-Min Kim;Amro Hasan Ageel;Shin Hwang;Dong-Hwan Jung;Tae-Yong Ha;Gi-Won Song;Gil-Chun Park;Chul-Soo Ahn;Deok-Bog Moon
    • Annals of Hepato-Biliary-Pancreatic Surgery
    • /
    • v.26 no.4
    • /
    • pp.308-312
    • /
    • 2022
  • Backgrounds/Aims: Although body surface area (BSA)-based standard liver volume (SLV) formulae have been used for living donor liver transplantation and hepatic resection, hemi-liver volume (HLV) is needed more frequently. HLV can be assessed using right or left portal vein diameter (RPVD or LPVD). The aim of this study was to validate the reliability of using portal vein diameter ratio (PVDR) for assessing HLV in living liver donors. Methods: This study included 92 living liver donors (59 males and 33 females) who underwent surgery between January 2020 and December 2020. Computed tomography (CT) images were used for measurements. Results: Mean age of donors was 35.5 ± 7.2 years. CT volumetry-measured total liver volume (TLV), right HLV, left HLV, and percentage of right HLV in TLV were 1,442.9 ± 314.2 mL, 931.5 ± 206.4 mL, 551.4 ± 126.5 mL, and 64.6% ± 3.6%, respectively. RPVD, LPVD, and main portal vein diameter were 12.2 ± 1.5 mm, 10.0 ± 1.3 mm, and 15.3 ± 1.7 mm, respectively (corresponding square values: 149.9 ± 36.9 mm2, 101.5 ± 25.2 mm2, and 237.2 ± 52.2 mm2, respectively). The sum of RPVD2 and LPVD2 was 251.1 ± 56.9 mm2. BSA-based SLV was 1,279.5 ± 188.7 mL (error rate: 9.1% ± 14.4%). SLV formula- and PVDR-based right HLV was 760.0 ± 130.7 mL (error rate: 16.2% ± 13.3%). Conclusions: Combining BSA-based SLV and PVDR appears to be a simple method to predict right or left HLV in living donors or split liver transplantation.

Analysis of Plate Cutting Performance of Aluminum Linear Shaped Charge with Non-uniform Penetration Performance (불균일한 침투성능을 갖는 알루미늄 선상성형작약의 판재 절개성능 분석)

  • Young Jae Kim
    • Journal of the Korea Society for Simulation
    • /
    • v.33 no.3
    • /
    • pp.27-35
    • /
    • 2024
  • Generally, an Linear Shaped Charge(LSC) is used for cutting a mechanical structure of various weapon systems. The penetration performance of an LSC is subjected to the type of explosive, the amount of explosive charge per unit length, the type of sheath material, stand-off distance from the target etc. In addition, the non-uniform cross-sectional shape originated from the manufacturing process may affect penetration performance. In this study, in order to analyze the penetration performance of an LSC, Computed Tomography(CT) images of its internal shape were taken and penetration experiments of the LSC were performed on a square metal bar. The experimental results showed that the penetration depths varied depending on the longitudinal position of the LSC, and at some locations, did not meet the required cutting performance. The LSC used in the experiment was manufactured to be able to cut a 4 mm plate, but in the results of the penetration performance experiment, there were many locations where the penetration depth was less than 4 mm. To find this reason, the penetration performance that did not meet the required cutting performance was simulated through AUTODYN based numerical analysis to confirm whether the LSC is cut in the plate. Through numerical analysis, it was confirmed that the penetration performance of an LSC varies depending on the thickness of the incision target due to the distribution of stress.

A Study on the Extraction Rate of Brain Tissues from a $^{99m}Tc$-HMPAO Cerebral Blood flow SPECT Examination of a Patient ($^{99m}Tc$-HMPAO 뇌혈류 SPECT 검사 시 환자에 따른 뇌조직 추출률에 대한 고찰)

  • Kim, Hwa-San;Lee, Dong-Ho;Ahn, Byeong-Pil;Kim, Hyun-Ki;Jung, Jin-Yung;Lee, Hyung-Nam;Kim, Jung-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.17-26
    • /
    • 2012
  • Purpose: This study mainly focuses on the patients treated with chemically stable radiopharmaceutical product $^{99m}Tc$-HMPAO (d,l-hexamethylpropylene amine oxime) which yielded reduced image quality due to a decreased brain extraction rate. $^{99m}Tc$-HMPAO will be examined further to determine whether this product may be accounted as a factor for this cause. Material and Methods: From January 2010 until December 2010, out of 272 patients who were all subjected to $^{99m}Tc$-HMPAO brain blood flow SPECT scans resulting from Cerebral Infarction; 23 patients(ages $55.3{\pm}9$, 21 males, 3 females) with decreased tissue extraction rate were examined in detail. The radiopharmaceutical product $^{99m}Tc$-HMPAO was used on patients with normal brain tissue exchange rate as well as those with reduced rate in order to prove its' chemical stability. The patients' age, sex, blood pressure, existence of diabetes, drug use, current health status, known side effects from CT/MRI, examination of the patients' past SPECT before/after images were accounted to determine the factors and correlations affecting the rate of blood tissue extractions. Result: After multiple linear regression analysis, there were no unusual correlations between the 6 factors excluding sex, and before/after examination images. Male subjects showed reduced brain tissue extraction rate than the females ($p$ > 0.05) 91.3% male, 8.7% female. Wilcoxon Matched-Pairs Signed-Ranks Test was used on the before/after images which yielded a value of 0.06, which did not indicate a significant amount of difference on the 2 tests ($p$ > 0.05). As a result, the before/after images indicated similar brain tissue extraction rates, and there were variations depending on the individual patient. Conclusion: The effects of the chemically stable radiopharmaceutical product $^{99m}Tc$-HMPAO depended on the patient's personal characteristics and status, therefore was considered to be a factor in reducing brain tissue extraction rate. The related articles of $^{99m}Tc$-HMPAO cerebral blood flow SPECT speculates a cerebrovascular disease and factors resulting from portal veins, and it was not possible to pin point the exact cause of decreasing brain tissue extraction rate. However, the $^{99m}Tc$-HMPAO cerebral blood flow SPECT scan proved to be extremely useful in tracking and inspecting brain diseases, as well as offering accurate results from patients suffering from reduced brain tissue extraction rates.

  • PDF