• Title/Summary/Keyword: CT실험편

Search Result 19, Processing Time 0.029 seconds

Effect of Specimen Orientation on Fatigue Crack Growth Behavior in Friction Stir Welded Al7075-T651 Joints (마찰교반용접된 Al7075-T651 용접부의 피로균열전파 거동에 미치는 시험편 채취방향의 영향)

  • Jeong, Yeui Han;Kim, Seon Jin
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.38 no.12
    • /
    • pp.1317-1323
    • /
    • 2014
  • The aim of this paper is to investigate the effects of crack orientation on fatigue crack growth behavior in friction stir welded (FSWed) Al 7075-T651. Fatigue crack growth testing was conducted on compact tension (CT) specimens machined from the friction stir welds and the base metal under constant stress intensity factor range control. Tests were performed with the crack propagating nominally perpendicular to the weld line (termed the TL specimen) and the crack propagating in a parallel direction of the weld line (termed the LT specimen), and with three different constant stress intensity factor ranges. Both these specimen orientations were found to have a considerable effect on the fatigue crack growth behavior. Paris's law was adopted for the analysis of experimental results; the exponent m of the WM-LT specimen was determined to be 3.56, which was the largest value in this experimental conditions.

JIC Evaluation of the Smooth and the Side-Grooved CT Specimens in the Reactor Pressure Vessel Steel(SA508-3) (원자력압력용기강 (SA508-3)의 평활 및 측면홈 CT시험편을 이용한 J$_{IC}$ 평가)

  • Oh, Sae-Wook
    • Journal of Ocean Engineering and Technology
    • /
    • v.8 no.2
    • /
    • pp.173-184
    • /
    • 1994
  • 원자력 압력용기강의 탄소성 파괴인성값 $J_IC$를 CT형 시험편을 이용하여 검토하였으며, 평활 시험편 및 측면홈 시험편의 두께는 각각 $B_O$=25.4mm, $B_N$=20.4mm 이다. 측면홈의 깊이는 19.7% 이며, 홈의 각도는 90 .deg.로 가공하였다. 탄소성 파괴인성시험은 ASTM E813-81과 JSME S001-81의 추천방법에 따라 실시하였다. 두 추천방법으로 실험한 결과 ASTM 방법에 의한 $J_IC$값이 과대평가됨으로써 부대조건에 만족되지 못하였지만 JSME방법은 만족되었다. 측면홈 시험편은 R고선법에 의한 ductile tearing의 결정이 평활 시험편보다 용이하였으며, 이에 따른 $J_IC$값의 정확성을 배가 할 수 있었다. 또한 임계 스트레치존 폭($SZW_C$)은 측면홈에 의한 높은 3축응력이 발생되어 평활시험편보다 적게 나타났으며, 이러한 복합적인 원인에 기인하여 스트레치존법에 의한 $J_IC$평가는 R곡선법에 의한 평가보다 약간 과대평가됨을 알 수 있었다.

  • PDF

Depth Sizing of Notch Fatigue Crack Using Diffracted Ultrasonic Wave (회절초음파를 이용한 노치 피로균열의 균열깊이 평가)

  • Jin, Mei-Ling;Lee, Tae-Hun;Park, Byung-Jun;Jhang, Kyung-Young
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.29 no.5
    • /
    • pp.405-414
    • /
    • 2009
  • This paper proposed a methodology based on ultrasonic diffraction technique to inspect the depth of a crack initiated from a notch of CT specimen by fatigue test, and its usefulness was verified by experiments. Especially, in order to identify accurately the diffractive waves from the crack tip in the situation where there are extra diffractive elements such as a notch, we have tried imaging by transducer scan and analyzed the propagation path of diffracted wave. Two specimens with and without a crack were experimented. Higher frequency and larger refractive angle of transducer showed a tendency to decrease the error in the measurements, and the measured crack depth showed an error less than 0.38 mm in case of 4 MHz $60^{\circ}-60^{\circ}$. The proposed methodology is applicable to weak diffractive sources, and so that it would be useful to inspect micro cracks and for their depth sizing.

The Experimental Method of Measuring Q (Q의 실험적 측정법)

  • Kim, Dong-Hak;Lee, Jeong-Hyun;Kang, Ki-Ju
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.285-291
    • /
    • 2003
  • An experimental method to measure Q-parameter in-situ is described. The basic idea comes from the fact that the side necking near a crack tip indicates the loss of stress triaxiality, which can be scaled by Q. From the out-of-plane displacement and the in-plane strain near the surface of side necking, stress field averaged through the thickness is calculated and then Q is determined from the difference between the stress field and the HRR field corresponding to the identical J-integral. To prove the validity, three-dimensional finite element analysis has been performed for a CT configuration with side-groove. Q-value which was calculated directly from the near-tip stress field is compared with that determined by simulating the experimental procedure according to the proposed method, that is, the Q-value determined from the lateral displacement and the inplane strain. Also, the effect of location where the displacement and strain are measured is explored.

  • PDF

Application of Total Variation Optimization for Reduction of Head CT Dose (두부 CT 선량감소를 위한 총변량 최적화의 적용)

  • Choi, Seokyoon
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.6
    • /
    • pp.707-712
    • /
    • 2018
  • The number of CT examinations is increasing, and radiation exposure is also increasing. repeated tests can affect the lens and thyroid. In hospitals, there is a tendency to lack interest in major long-term radiation exposure compared to the interest in increasing image information and image quality with head CT. In this study, we analyzed the improvement of image quality by proposed method to the noisy CT images. The proposed denoising method total variance optimization only for the impulsive noise candidate pixels. Experimental results show that edge information is well preserved and impulse noise can be effectively removed. and worked very well for the images according to tube voltage and rotation time. applied to the clinical setting, it can be used as the lowest exposure condition without worrying about the image quality and it will be helpful for the CT application.

A Study on the Behavior of the Plane Stress Fracture Toughness - About the Compact Tension Specimen- (平面應力 破壞靭性値 擧動에 관한 硏究)

  • 송삼홍;고성위
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.10 no.6
    • /
    • pp.937-946
    • /
    • 1986
  • In this paper, the plane stress fracture toughness of low carbon steel with 3mm thickness is investigated for various specimen widths and crack ratios using the J integral. The experiments is carried out for the compact tension(CT) specimen on an Instron machine. For materials that may be approximated by the Ramberg and Osgood stress strain law, the relevant crack parameter like the J integral and load line displacement are approximately normalized. Crack driving forces in terms of J integral is computed using the above estimation scheme. Abtained results are summarized as follows. (1) The plane stress fracture toughness, J$_{c}$, is almost constant in the range 50-70mm of width. Hence J$_{c}$ can be obtained by using smaller specimen than ASTM standard. (2) Yoon's and Simpson's formular which considers crack growth in obtaining J integral show more consevative J than Rice's and Merkle's (3) J$_{c}$ is almost constant in the range 0.499-0.701 crack ratios tested. J$_{c}$ obtained by using Kumar's formular is 28.14kgf/mm for base metal specimen and 32.51kgf/mm for annealed. (4) Comparison of the prediction with actual experimental measurements by Yoon's formular show good agreement for several different-size specimens.

The Effect of Specimen Thickness on the Fatigue Crack Propagation Rate (피로크랙전파율에 대한 시험편 두께의 영향)

  • Koh, Sung-Wi;Um, Yoon-Sung
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.24 no.1
    • /
    • pp.44-49
    • /
    • 1988
  • The paper presents the preliminary results of an esperimental study on crack growth under tension-tension fatigue loading. A purpose of the study is to find the effect of the specimen thickness on crack propagation behaviors. The thickness of the low catbon steel specimens the are used in the experiments are 5, 10, 15,20, and 25 mm. the type of specimen considering in the present study is compact tension specimen.Crack growth behaviors are obseved and measured by travelling microscope. From the study, the followings are found; 1. There is a certain specimen thickness that is the shortest farigue life. The fatigue life of 15mm specimen is the shorter then that of any other opecimen 2. The crack initiation of the thick specimen is slower than that of thin specimen. But the crack propagation rate is just the opposite. 3. The range which is the exponent, m of power law(paris) is 1.98-4.59. the thicker the spec-imen is, the higher the value of m is.

  • PDF

Variation of A2 with Crack Propagation in a Ductile Metal; Experimental Evaluation (연성재료의 균열진전에 따른 A2의 변화; 실험적 측정)

  • Kim, Heon-Joong;Kim, Dong-Hak;Yang, Kyeong-Jin;Kang, Ki-Ju
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.27 no.1
    • /
    • pp.119-125
    • /
    • 2003
  • A way to measure the second parameter $A_2$of CT specimens is described. The displacement $\delta$$_{5}$ which is measured continuously from visual images of the lateral surface during crack growth is used to calculate the A, as a function of crack growth. The crack length is measured by DCPD(Direct Current Potential Drop) method and the J-resistance curve is determined according to ASTM standard E1737-96. To prove the validity of this method, three dimensional finite element analyses were performed, and variations of the displacements $\delta$$_{5}$ and $A_2$along the thickness were explored. As the result, it has been shown that the $\delta$$_{5}$ measured from the visual images of the lateral surface and the corresponding $A_2$can be regarded as the average through the thickness for 1T and 1/2T specimens of SA106Gr.C steel.steel.

An Experimental Method for Measuring Q (Q의 실험적 측정법)

  • Kim, Dong-Hak;Lee, Jeong-Hyun;Kang, Ki-Ju
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.27 no.9
    • /
    • pp.1607-1613
    • /
    • 2003
  • An experimental method to measure Q-parameter in-situ is described. The basic idea comes from the fact that the side necking near a crack tip indicates the loss of stress triaxiality, which can be scaled by Q. From the out-of-plane displacement and the in-plane strain near the surface of side necking, stress field averaged through the thickness is calculated and then Q is determined from the difference between the stress field and the HRR field corresponding to the identical J-integral. To prove the validity, three-dimensional finite element analysis has been performed for a CT configuration with side-groove. Q-value which was calculated directly from the near-tip stress field is compared with that determined by simulating the experimental procedure according to the proposed method, that is, the Q-value determined from the lateral displacement and the in-plane strain. In addition, the effect of location where the displacement and strain are measured is explored.

The Thickness Effect on the Determination of Fracture Toughness Jic (파괴인성치 Jic 결정에 대한 시험편 두께의 영향에 관한 연구)

  • 고성위
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.24 no.2
    • /
    • pp.83-93
    • /
    • 1988
  • Recent Experimental results show that the J integral can be effectively used to obtain a valid parameter for predicting plane strain and plane stress fracture. However, only a few research results have been reported for the effect of thickness where the plane strain state can not be assumed. A purpose of this study is to find the behavior of fracture touhness and tearing modulus varing the specimen thickness. The type of specimen in the present study is compact tension (CT). The thicknesses of the low carbon steel specimens that are used in the experiments are 5, 10, 15, 20 and 25mm. The measurement of crack length is taken by optical measurements method. From the study, the followings are found; 1) The fracture toughness and the tearing modulus which are obtained by using Yoon's and Simpson's formula show more conservative than that by using Rice's and Merkel's. 2) The fracture toughness is increase in specimen thickness which is reached 15mm. Beyond this thickness the fracture toughness is decreased in specimen thickness. 3) In the case of CT specimen with the thickness ranging from 5 to 25mm, the tearing modulus which is applied the same J integral equation is almost constant. 4) By using Yoon's formula, the correlation of the plane slress fracture toughness J sub(C) with specimen thickness B is expressed as the following formula. J sub(C)/J sub(IC)=1.7-15.1(B/W)+112.9(B/W) super(2) -301.3(B/W) super(3) +260.6(B/W) super(4)

  • PDF