• 제목/요약/키워드: CT검사시간

검색결과 2건 처리시간 0.016초

전산화단층촬영의 소요시간 분석에 기반한 방사선사의 적정인력 산정에 관한 연구 (Estimation of Appropriate Number of Radiologic Technologist Based on Analysis of Time Required for Computed Tomography)

  • 이기백;김영균;김은혜;김연민
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제45권3호
    • /
    • pp.213-223
    • /
    • 2022
  • Although the number of computed tomography(CT) is increasing every year, it is insufficient to establish appropriate workload calculation standards of radiologic technologist to provide optimal medical services to patients, such as patient safety management and infection management. The purpose of this study is to present guidelines for calculating the appropriate workload of radiologic technologist by analyzing the work flow of CT procedures and the time required for CT examination in major hospitals. As for the study subjects and methods, the appropriate process for each step of CT examination was investigated to systematically present the process and time required for the actual examination, and the CT procedure time of 104,105 adult patients and 465 pediatric patients under the age of 6 were analyzed. For the time required, data according to the use of contrast medium, procedure type, and adult/child were collected and compared. The test time of CT examination using contrast medium took about 13 minutes when one radiologic technologist worked and about 9 minutes when two radiologic technologists worked. The time required for the procedures were statistically significant depending on the presence or absence of contrast medium, multi-phase procedure, and patient age (considering pediatric patients). As a result, in order to thoroughly perform patient safety and infection management, the appropriate workload increased by about 40% when there were two radiologic technologists. The limit workload was an average of 32 people per day with one radiologic technologist per 15 minutes, and 48 people per day with two radiologic technologist per 10 minutes. This is a marginal workload, and in the case of procedures that require more time to acquire radiographic images, the interval between reservations should be widened.

전산화 단층촬영시 주선속내 외의 주요장기 흡수선량 비교분석 (Comparative Analysis of Absorption Doses between Exposed and Unexposed Area on Major Organs During CT Scan)

  • 사정호;서태석;최보영;정규회
    • 한국의학물리학회지:의학물리
    • /
    • 제11권1호
    • /
    • pp.59-71
    • /
    • 2000
  • CT검사시 선량이 각 장기에 미치는 영향을 관찰 하고자 하였으며, 선정한 3부위(뇌, 흉부, 복부) 스캔에서 주 선속 및 주 선속외에 미치는 흡수선량을 측정 제시하고, 자궁에 영향을 주는 부위 스캔을 명확히 알고자 하였다. CT기계(Somatom plus 4, Siemens co, Germany)를 이용하였으며 인체에 조직등가 물질이 비슷한 Alderson Rando phantom (Alderson Reserch Laboratories, USA)과 Harshaw chemical 사에서 제작된 열형광선량계 Thermoluminescent dosimeter (TLD)-100 과 Reader와 Oven을 이용하였다. TLD 교정시에, 6MV 선형가속기와 $30{\times}30{\times}1.5$cm의 정사각형 고체 물팬텀을 사용하였다. TLD를 팬텀의 목적장기에 삽입시키기 위하여, 여성환자 (20세~40세) 40명의 영상을 이용하였으며, 위치 측정부위는 간, 위장, 비장, 신장, 대장, 방광, 자궁을 대상으로 하였다. Brain에서의 흡수선량 분포도에서 8 : 8(피치1) 에서는 비장까지 흡수선량이 측정되었으며 10 : 10 에서는 유방까지 흡수선량이 측정되었다. 흥부(Chest)에서의 흡수선량 분포도에서 8 : 8(피치1)에서의 주 선속 흡수선량이 높았다. Abdomen의 흡수선량 분포도에서 8 : 8 과 8 : 10의 스캔을 했을 때 주 선속 부위에서는 테이블 이동이 느린 8mm에서 흡수선량이 높게 나타났다. 뇌 CT의8 : 8과 10 : 10에서 자궁에 미치는 선량은 모두 없었으며, 몸 전체에 미치는 유효선량은 10 : 10 약간 높게 나타났다. Brain CT 에서 임산부나 임신가능 여성에게는 본 논문에서 확인된 방법으로 절편 두께를 8mm-10mm범위로 적용하는 것이 바람직 하고, Chest scan에서 8 : 10(피치 1.2)방법을 선택하는 것이 좋으며, 임산부나 임신 가능 환자에게는 10 : 15(피치 1.5)를 사용하는 것이 좋은 것으로 사료된다. Abdomen scan에서 유효선량이 10.707 mSv, MSAD가 7.2인 8 : 10을 택하는 것이 주 선속에 미치는 영향뿐만 아니라 생식선 장기인 Uterus에 미치는 영향이 비교적 적게 나타나, 다른 기법보다 다소 환자에게 적게 영향을 주며 검사 할 수 있다고 사료된다.

  • PDF