• 제목/요약/키워드: CT/MRI

검색결과 892건 처리시간 0.035초

Cross-Sectional and Skeletal Anatomy of Long-tailed Gorals (Naemorhedus caudatus) Using Imaging Evaluations

  • Sangjin Ahn;Woojin Shin;Yujin Han;Sohwon Bae;Cheaun Cho ;Sooyoung Choi;Jong-Taek Kim
    • Journal of Veterinary Science
    • /
    • 제24권4호
    • /
    • pp.60.1-60.8
    • /
    • 2023
  • Background: Accurate diagnosis of diseases in animals is crucial for their treatment, and imaging evaluations such as radiographs, computed tomography (CT), and magnetic resonance imaging (MRI) are important tools for this purpose. However, a cross-sectional anatomical atlas of normal skeletal and internal organs of long-tailed gorals (Naemorhedus caudatus) has not yet been prepared for diagnosing their diseases. Objectives: The objective of this study was to create an anatomical atlas of gorals using CT and MRI, which are imaging techniques that have not been extensively studied in this type of wild animal in Korea. Methods: The researchers used CT and MRI to create an anatomical atlas of gorals, and selected 37 cross-sections from the head, thoracic, lumbar, and sacrum parts of gorals to produce an average cross-sectional anatomy atlas. Results: This study successfully created an anatomical atlas of gorals using CT and MRI. Conclusions: The atlas provides valuable information for the diagnosis of diseases in gorals, which can improve their treatment and welfare. The study highlights the importance of developing cross-sectional anatomical atlases of gorals to diagnose and treat their diseases effectively.

Diagnostic Performance and Prognostic Relevance of FDG Positron Emission Tomography/Computed Tomography for Patients with Extrahepatic Cholangiocarcinoma

  • Nam Hee Kim;Sung Ryol Lee;Young Hwan Kim;Hong Joo Kim
    • Korean Journal of Radiology
    • /
    • 제21권12호
    • /
    • pp.1355-1366
    • /
    • 2020
  • Objective: We aimed to evaluate the diagnostic value and prognostic relevance of FDG positron emission tomography/computed tomography (PET-CT) in extrahepatic cholangiocarcinoma patients. Materials and Methods: This study included 234 extrahepatic cholangiocarcinoma patients who underwent FDG PET-CT between June 2008 and February 2016. The diagnostic performance of FDG PEG-CT was compared to that of contrast-enhanced multidetector row CT (MDCT) and MRI. Independent prognosticators for poor survival were also assessed. Results: The sensitivity of FDG PET-CT for detecting primary tumor and regional lymph node metastases was lower than that of MDCT or MRI (p < 0.001), whereas the specificity and positive predictive value for detecting regional lymph nodes metastases was significantly better in FDG PET-CT compared to MDCT and MRI (all p < 0.001). There was no significant difference in the diagnostic yield of distant metastases detection among three diagnostic imaging techniques. In a multivariate analysis, maximum standardized uptake values (SUVmax) of the primary tumor (adjusted hazard ratio [HR], 1.75; 95% confidence interval [CI], 1.13-2.69) and of the metastatic lesions ≥ 5 (adjusted HR, 8.10; 95% CI, 1.96-33.5) were independent contributors to poor overall survival in extrahepatic cholangiocarcinoma patients. In a subgroup analysis of 187 patients with periductal infiltrating type of cholangiocarcinoma, an SUVmax of the primary tumor ≥ 5 was associated with an increased risk of regional lymph node (adjusted odds ratio [OR], 1.60; 95% CI, 0.55-4.63) and distant metastases (adjusted OR, 100.57; 95% CI, 3.94-2567.43) at diagnosis as well as with poor overall survival (adjusted HR, 1.81; 95% CI, 1.04-3.15). Conclusion: FDG PET-CT showed lower sensitivity for detecting primary tumor and regional lymph node involvement than MDCT and MRI. However, the SUVmax of primary tumors and metastatic lesions derived from FDG PET-CT could have significant implications for predicting prognoses in extrahepatic cholangiocarcinoma patients.

Multidetector CT arthrography를 이용한 견관절 병변의 진단 - MRI, MR arthrography와의 비교 - (Multidetector CT (MDCT) Arthrography in the Evaluation of Shoulder Pathology: Comparison with MR Arthrography and MR Imaging with Arthroscopic Correlation)

  • 김재윤;공현식;김우성;최정아;김병호;오주한
    • Clinics in Shoulder and Elbow
    • /
    • 제9권1호
    • /
    • pp.73-82
    • /
    • 2006
  • Purpose: The purpose of the present study was to evaluate the diagnostic efficacy of CT arthrography (CTA) in the assessment of various shoulder pathologies, compared with MR arthrography (MRA) and MRI with arthroscopic correlation. Materials and Methods: CTA in 84 patients, MRA in 70 patients, and MRI in 27 patients were obtained. A radiologist interpreted each image for 5 pathologies: Bankart, SLAP, Hill-Sachs lesion, full-thickness, and partial-thickness rotator cuff tear. Detailed arthroscopic reports were compared with CTA, MRA, and MRI. The sensitivity, specificity, predictive values, and accuracy were calculated. The agreement between each diagnostic modality and arthroscopy was calculated. Diagnostic efficacy was assessed by the areas under the receiver operating characteristic (ROC) curves. Results: The diagnostic values of all three imaging groups were comparable to each other for Bankart, SLAP, Hills-Sachs, and full-thickness cuff tear lesions, but those of CTA were lower than MRI and MRA for partial-thickness cuff tears. The areas under the ROC curves for CTA, MRA, and MRI were not significantly different for all pathologies, except for partial-thickness cuff tears. Conclusion: CTA was equally competent to MRA or MRI in demonstrating Bankart, Hill-Sachs lesions, SLAP, and full thickness rotator cuff tears but not as efficient in diagnosing partial thickness rotator cuff tears.

Relationship between 18F-FDG PET/CT Semi-Quantitative Parameters and International Association for the Study of Lung Cancer, American Thoracic Society/European Respiratory Society Classification in Lung Adenocarcinomas

  • Lihong Bu;NingTu;Ke Wang;Ying Zhou;Xinli Xie;Xingmin Han;Huiqin Lin;Hongyan Feng
    • Korean Journal of Radiology
    • /
    • 제23권1호
    • /
    • pp.112-123
    • /
    • 2022
  • Objective: To investigate the relationship between 18F-FDG PET/CT semi-quantitative parameters and the International Association for the Study of Lung Cancer, American Thoracic Society/European Respiratory Society (IASLC/ATS/ERS) histopathologic classification, including histological subtypes, proliferation activity, and somatic mutations. Materials and Methods: This retrospective study included 419 patients (150 males, 269 females; median age, 59.0 years; age range, 23.0-84.0 years) who had undergone surgical removal of stage IA-IIIA lung adenocarcinoma and had preoperative PET/CT data of lung tumors. The maximum standardized uptake values (SUVmax), background-subtracted volume (BSV), and background-subtracted lesion activity (BSL) derived from PET/CT were measured. The IASLC/ATS/ERS subtypes, Ki67 score, and epidermal growth factor/anaplastic lymphoma kinase (EGFR/ALK) mutation status were evaluated. The PET/CT semi-quantitative parameters were compared between the tumor subtypes using the Mann-Whitney U test or the Kruskal-Wallis test. The optimum cutoff values of the PET/CT semi-quantitative parameters for distinguishing the IASLC/ATS/ERS subtypes were calculated using receiver operating characteristic curve analysis. The correlation between the PET/CT semi-quantitative parameters and pathological parameters was analyzed using Spearman's correlation. Statistical significance was set at p < 0.05. Results: SUVmax, BSV, and BSL values were significantly higher in invasive adenocarcinoma (IA) than in minimally IA (MIA), and the values were higher in MIA than in adenocarcinoma in situ (AIS) (all p < 0.05). Remarkably, an SUVmax of 0.90 and a BSL of 3.62 were shown to be the optimal cutoff values for differentiating MIA from AIS, manifesting as pure ground-glass nodules with 100% sensitivity and specificity. Metabolic-volumetric parameters (BSV and BSL) were better potential independent factors than metabolic parameters (SUVmax) in differentiating growth patterns. SUVmax and BSL, rather than BSV, were strongly or moderately correlated with Ki67 in most subtypes, except for the micropapillary and solid predominant groups. PET/CT parameters were not correlated with EGFR/ALK mutation status. Conclusion: As noninvasive surrogates, preoperative PET/CT semi-quantitative parameters could imply IASLC/ATS/ERS subtypes and Ki67 index and thus may contribute to improved management of precise surgery and postoperative adjuvant therapy.

Leak Sign on Dynamic-Susceptibility-Contrast Magnetic Resonance Imaging in Acute Intracerebral Hemorrhage

  • Park, Ji Kang;Hong, Dae Young;Jin, Sun Tak;Lee, Dong-Woo;Pyun, Hae Wook
    • Investigative Magnetic Resonance Imaging
    • /
    • 제24권3호
    • /
    • pp.154-161
    • /
    • 2020
  • Purpose: A CT angiography spot sign (CTA-spot) is a significant predictor of the early expansion of an intracerebral hemorrhage (ICH-Ex). Dynamic-susceptibility-contrast magnetic resonance imaging (DSC-MRI) can track the real-time leaking of contrast agents. It may be able to indicate active bleeding, like a CTA-spot. Materials and Methods: From September 2014 to February 2017, we did non-contrast CT, CTA, and DSC-MRI examinations of seven patients with acute ICH. We investigated the time from symptom onset to the first contrast-enhanced imaging. We evaluated the time course of the contrast leak within the ICH at the source image of the DSC-MRI and the volume change of ICH between non-contrast CT and DSC-MRI. We compared the number of slices showing CTA-spots and DSC-MRI leaks. Results: The CTA-spot and DSC-MRI leak-sign were present in four patients, and two patients among those showed ICH-Ex. The time from the symptom onset to CTA or DSC-MRI was shorter for those with a DSC-MRI leak or CTA-spot than for three patients without either (70-130 minutes vs. 135-270 minutes). The leak-sign began earlier, lasted longer, and spread to more slices in the patients with ICH-Ex than in those without ICH-Ex. The number of slices of the DSC-MRI leak and the number of the CTA-spot were well correlated. Conclusion: DSC-MRI can demonstrate the leakage of GBCA within hyperacute ICH, showing the good contrast between hematoma and contrast. The DSC-MRI leakage sign could be related to the hematoma expansion in patients with ICH.

ViewRay MRIdian System을 이용한 MRI only based plan의 유용성 고찰 (A study of usefulness for the plan based on only MRI using ViewRay MRIdian system)

  • 전창우;이호진;안범석;김찬용;이제희
    • 대한방사선치료학회지
    • /
    • 제27권2호
    • /
    • pp.131-143
    • /
    • 2015
  • 목 적 : MRI를 기반으로 한 CT fusion plan과 MRI only based plan을 비교함으로써 MRI only plan의 유용성을 평가하고, 나아가 Simulation과 치료계획을 포함한 방사선치료의 전 과정을 CT 촬영 없이 MRI 영상으로 구성하여 실시간 MR-IGRT를 구현하고자 한다. 대상 및 방법 : 본원에서 사용중인 BBB CT (Brilliance Big Bore CT, 16slice, Philips)와 Viewray MRIdian System (Viewray, USA)으로 환자 11명(Head and Neck 1명, Breast 5명, Lung 1명, Liver 3명, Prostate 1명)을 대상으로 CT & MR simulation 및 치료계획을 세웠다. Head and Neck, Breast, Prostate환자는 자유호흡(Free Breathing) 상태로, Lung과 Liver 환자는 흡기 호흡중지(Inhalation Breathing Holdng)상태로 Simulation을 진행하였다. Viewray의 Bore 크기 및 Coil 위치를 고려하여 환자 자세 및 고정기구를 동일한 조건을 유지하여 CT simulation을 시행하였다. Viewray MRIdian 시스템을 이용하여 MR 영상을 기반으로 한 CT fusion plan과 CT fusion 없이 [ICRU 46]에서 권고하는 폐, 공기, 뼈의 전자밀도를 입력한 동일한 조건의 MR only plan을 세웠다. Head and Neck, Breast, Prostate는 IMRT, Lung과 Liver 는 Gating치료계획을 세웠고, 치료계획의 평가는 PTV의 균질성 지표 (Homogeneity Index, HI)와 일치성 지표 (Conformity Index, CI), 그리고 각 PTV와 OAR의 DVH와 선량차이를 각각 비교하였다. 결 과 : 두 치료계획간 치료부위별 PTV에 대한 HI 값의 차이는 Head and Neck, Breast, Lung, Liver, Prostate 부위별로 각각 0.089, 0.26, 0.67, 0.2, 0.4%로 나타났으며, CI 값의 차이는 부위별로 각각 0.043, 0.84, 0.68, 0.46, 0.3%로 두가지 평가 값 모두 Head and Neck 부위가 가장 작은 차이를 나타냈다. PTV에 대한 평균선량 차이는 치료부위별로 각각 0.07, 0.29, 0.18, 0.3, 0.18 Gy로 나타났다. 이를 백분율로 나타냈을 때 0.06, 0.7, 0.29, 0.69, 0.44%으로 모두 1% 이하의 차이를 보였다. 두경부암의 각 OAR은 전체적으로 0.01~0.12 Gy의 평균선량 차이를 보였으며, 유방암은 0.04~0.06 Gy, 폐암에서는 0.01~0.21 Gy, 간암은 0.06~0.27 Gy, 전립선암은 0.02~0.23 Gy의 평균선량 차이를 나타냈다. 결 론 : MR 영상을 이용한 치료계획은 연부조직에서 탁월한 대조도를 나타낼 뿐만 아니라 CT fusion한 MR 치료계획과 비교했을 때 PTV의 HI, CI, 선량차이 모두 1%미만의 차이를 보였으며, OAR의 경우 비균질한 조직이 많은 부위일수록 최대 0.89 Gy 선량차이를 보였다. 이결과를 토대로 두경부암, 부분적 유방암이나 전립선암등 비균질도 차이가 적은 부위에는 CT촬영 없이 MR 영상만을 이용한 방사선치료의 가능성을 확인 할 수 있었다.

  • PDF

3차원 볼륨 렌더링을 이용한 가상 돌출형 전립선 부피 평가 (Evaluation on Protrusion of the Imaginary Prostate Volume Using Three-Dimensional Volume Rendering)

  • 성열훈;주용현;임재동;최보영
    • 한국의학물리학회지:의학물리
    • /
    • 제20권4호
    • /
    • pp.208-215
    • /
    • 2009
  • 2차원의 영상을 이용한 돌출형 전립선 비대증의 부피 평가방법에서 돌출부위를 포함시킬 경우와 포함시키지 않을 경우의 부피변화를 3차원 볼륨 렌더링(volume rendering, VR)을 이용하여 비교 평가하고자 한다. 돌출형 전립선 부피측정을 위한 가상 전립선 모델은 곤약을 이용해 임의로 평균 1 cm 정도로 돌출되도록 하여 10 ml에서 각각 10 ml씩 부피를 변화시켜 100 ml까지 총 10 개의 모델을 제작하였다. 이 때 제작된 모델의 부피측정은 64 channel 전산화단층촬영(computed tomography, CT)과 3.0 Tesla 자기공명영상(magnetic resonance image, MRI)을 이용하여 획득된 3차원 볼륨 영상자료로 계측하였다. 산출한 CT와 MRI영상들의 3차원 볼륨데이터 근접성 평가를 위해 wilcoxon 부호순위(signed rank) 검정을 하였다. 또한 획득한 영상자료는 3차원 영상처리를 통하여 볼륨 렌더링으로 재구성한 후 타원체부피공식법을 이용하여 돌출부위를 포함시킬 때와 포함하지 않을 때의 부피를 구하였다. 이 때 돌출 유무에 따라 각각 측정된 부피와 3차원 볼륨 렌더링의 부피를 wilcoxon 부호순위(signed rank) 검정을 사용하여 유의성을 평가했으며 상관계수(pearson's correlation coefficient, r)를 사용하여 상관관계를 분석하였다. 계측된 가상 전립선 모델의 돌출부위길이는 CT에서 $0.90{\pm}0.18\;mm$, MRI에서 $0.75{\pm}0.11\;mm$이었으며, CT와 MRI에서 계측된 3차원 영상 부피의 p-value는 0.414로 유의한 차이는 없었다. 그러나 MRI에서 측정된 3차원 영상 부피와 2차원 영상에서 돌출부위를 포함시킬 때의 p-value는 0.005인 반면 포함하지 않을 때의 p-value는 0.139로 나타났으며, CT에서도 측정된 3차원 영상 부피와 2차원 영상에서 돌출부위를 포함시킬 때의 p-value는 0.005인 반면 포함하지 않을 때의 p-value는 0.057로 나타났다. 돌출형 전립선의 부피측정은 돌출부위를 제외하고 상하길이를 측정하는 것이 3차원 볼륨 렌더링에 의한 부피 값과 더 가까운 부피 값을 얻을 수 있었다.

  • PDF

유방암환자의 양전자방출단층촬영술에서 암 전이로 오인된 섬유형성이상 진단의 자기공명영상과 단순촬영의 역할 (Role of MRI and Plain Radiograph to Diagnose Fibrous Dysplasia Mimicking Metastasis on PET/CT in a Patient with Breast Cancer)

  • 조송미;지원희;유이령;이아원;정양국
    • 대한골관절종양학회지
    • /
    • 제16권1호
    • /
    • pp.47-50
    • /
    • 2010
  • 섬유형성이상은 골수가 섬유-골성 조직으로 치환되는 흔한 양성 골 질환이다. 암환자에서 병기의 결정과 추적 검사 시 암 전이의 발견에 PET/CT의 역할이 증가됨에 따라 우연히 발견된 FDG 섭취 증가를 보이는 섬유형성이상에서 암 전이와의 감별이 중요하다. PET/CT를 시행한 46세의 유방암 환자에서 좌측 대퇴골에 국소 FDG 섭취를 보여 암 전이로 의심되었으나 단순촬영과 자기공명 영상 소견에서 섬유형성이상으로 진단한 환자의 증례를 보고하고자 한다. 이 환자에서 단순활영과 자기공명영상 소견은 PET/CT에서 유방암 전이로 오인된 섬유형성이상의 감별에 도움이 되었다.

대퇴 골두 충돌 증후군(Cam type)의 진단과 치료를 위한 자기공명 3D 영상 재구성 기법의 유용성 (Usefulness of MRI 3D Image Reconstruction Techniques for the Diagnosis and Treatment of Femoral Acetabular Impingement Syndrome(Cam type))

  • 곽영곤;김종일;조영기
    • 한국콘텐츠학회논문지
    • /
    • 제15권11호
    • /
    • pp.313-321
    • /
    • 2015
  • Hip FAI 진단과 수술 계획 시 Hip FAI MRI 검사시 3D 영상을 추가로 활용하여 CT 영상으로 이루어지는 Hip Clock face 영상을 MRI 3D 영상으로 대체할 수 있는지 비교 평가 하였다. Hip 자기공명 영상검사(MRI)와 3D Hip 컴퓨터 단층 촬영(CT)을 동시 시행한 환자 31명 (남: 21명 평균연령: 35세 여: 10명 평균연령: 40.3세)을 대상으로 분석하였으며, 영상평가는 정형외과 전문의 1명과 영상의학과 전문의 1명이 MR과 CT modality에서 Hip joint articular transverse ligament의 6 o'clock을 중심으로 Superior을 12 o'clock, Labrum의 전면을 3 o'clock, 반대쪽을 9 o'clock로 기술하는 Clock face을 재구성 한 후 11 o'clock에서 A. retinacular vessel, B. head neck junction, 12 o'clock A. Epiphyseal line, B. Cam lesion, 1,2,3,4 o'clock의 Cam lesion, Posterior Cam lesion확인 여부를 리커트(Likert scale) 5점 척도로 평가하였다(Independent t-test p<0.05). 리커드 척도 결과 11 o'clock A. retinacular vessel MR 평균 값 $3.69{\pm}1.0$, CT 평균값 $2.8{\pm}0.78$이며 통계적으로 유의하였다(p<0.001). B. head neck junction은 두 평가자간 차이가 없었다(p<0.416). 12 o'clock A. Epiphyseal line MR 평균값 $3.54{\pm}1.00$, CT 평균값 $4.5{\pm}0.62$이었다(p<0.000). B. Cam lesion은 두 평가자간 차이가 없었다(p<0.532). 1,2,3,4 o'clock 의 Cam lesion과 Posterior Cam lesion은 통계적으로 유의하지 않았다(p<0.656, p<0.658). weighted Kappa 검증 결과 11 o'clock A.retinacular vessel CT K값이 0.663으로 가장 낮은 일치도였으며, 각각의 평가 항목의 일치도 평가 결과 매우 높은 결과로 두 평가자간 높은 신뢰도를 보여주었다.

Rapid Prototyping을 이용한 임플란트 생성

  • 방철배;김영호;강석호
    • 한국경영과학회:학술대회논문집
    • /
    • 한국경영과학회 1997년도 추계학술대회발표논문집; 홍익대학교, 서울; 1 Nov. 1997
    • /
    • pp.37-40
    • /
    • 1997
  • RP(Rapid Prototyping) 기술은 점점 그 활용범위를 넓혀가는 추세이며, 의료분야에서도 임플란트의 제작등에 RP 기술의 도입이 시도되고 있다. 뼈나 치아 등의 인체부속물들은 속성상 직접 그 형태를 파악하기가 힘들고, 따라서 그 대체물인 임플란트의 제작을 위해 MRI나 CT등의 장비가 사용되고 있다. 의료분야에까지 이르는 RP의 활발한 활용에도 불구하고, 아직 국내에서는 RP에 대한 인식이 부족하고 그 활용에 대한 연구가 거의 없는 상황이다. 본 논문은 MRI, CT등의 2차원 평면데이터로부터 직접 RP 기계의 표준입력화일인 STL 파일을 생성시키기 위한 방법을 제시한다. 그리고 MRI로 스캐닝된 사람의 머리뼈 형상을 삼각메쉬 형태의 STL 파일로 변화하여 RP 기계를 통한 실물 모형 제작이 가능하도록 한 예를 설명하였다.

  • PDF