• Title/Summary/Keyword: CSF flow study

Search Result 37, Processing Time 0.018 seconds

Clinical Usefulness of Phase-Contrast Cine MRI Evaluation in Patients with Cervical Myelopathy (경추 척수병증 환자에 있어서 Phase-Contrast Cine MRI 평가의 임상적 유용성)

  • Lim, Jeong-Hwan;Song, Jun-Hyeok;Shin, Kyu-Man;Kim, Sung-Hak
    • Journal of Korean Neurosurgical Society
    • /
    • v.29 no.12
    • /
    • pp.1634-1641
    • /
    • 2000
  • Objective : The cerebrospinal fluid(CSF) pulsates within the craniospinal axis in response to rhythmic cerebral blood volume variation during the cardiac cycle. The aim of this study is to characterize the normal and abnormal CSF flow and its waveforms in the cervical spinal subarachnoid space. Methods : The magnetic resonance(MR) images were obtained with 1.5 T(GE Signa, GE Medical Systems, Milwaukee, USA) unit using the 2 dimensional cine PC(phase contrast) sequence with cardiac gating and gradient recalled echo imaging. This pulse sequence yielded 16 quantitative flow-encoded images per cardiac cycle. Sagittal and axial images of the cervical spinal CSF space were obtained, and target sites were analyzed for characteristic CSF flow (TR=50ms, TE=12.5-15ms). The region of interest(ROI) was 1mm 3 in volume. Twenty six persons were included in this study : 10 healthy volunteers and 16 patients with cervical myelopathy. The post-operative cine MR study were also done in five patients. Results : The normal CSF pulsation dynamics in the cervical spine showed discrete systolic and diastolic components. The CSF flow revealed a sine wave pattern, in which the systolic phase was shorter than the diastolic phase(ratio=2 : 3). The patient group revealed decreased amplitudes of the CSF flow and irregularly distored flow waves. The systolic phase was elongated in the ROI above the stenotic level, whereas the diastolic phase was lengthened below the level. In the postoperative images, the abnormal pattern and amplitude were found to be corrected. Conclusion : From these results, the authors believe that the CSF flow study provides valuable informations regarding the extent of cervical stenosis and may be useful for the surgical planning and post-operative evaluation.

  • PDF

Flow/solid Interaction Analysis for Design of Medical CSF-Flow Control Valve (의료용 CSF 제어 밸브 설계를 위한 유동/구조 상호작용 해석)

  • Won C. S.;Hur N.;Lee C .S.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2000.05a
    • /
    • pp.21-26
    • /
    • 2000
  • Pressure-flow control characteristics of a commercially available cerebrospinal flow(CSF) control shunt valve was tested using fluid-solid interaction analysis. Pre-stress of the valve diaphragm(membrane) was computed for proper valve opening. The results were ir good agreements with the valve specification listed in the commercially available CSF control valve. The results of the study can be effectively used to design variety of CSF control shunt valves.

  • PDF

A Flow/structure Interaction Analysis for the Design of Medical CSF-Flow Control Valve (의료용 CSF 제어 밸브 설계를 위한 유동/구조 상호작용 해석)

  • Won C. S.;Hur N.;Lee C. S.
    • Journal of computational fluids engineering
    • /
    • v.6 no.1
    • /
    • pp.40-46
    • /
    • 2001
  • Pressure-flow control characteristics of a commercially available cerebrospinal flow(CSF) control shunt valve was studied using flow/structure interaction analyses. Pre-stress of the valve diaphragm(membrane) was accounted for the simulation of an actual valve. The present results were in good agreement with the valve specification listed in the commercially available CSF control valve. The flow/structure interaction analysis of the present study can be effectively used to design a variety of CSF control shunt valves.

  • PDF

Transcranial Doppler and Cerebrospinal Fluid Flow Study in Normal Pressure Hydrocephalus

  • Lee, Hui-Keun;Hu, Chul;Whang, Kum;Kim, Hun-Joo
    • Journal of Korean Neurosurgical Society
    • /
    • v.39 no.1
    • /
    • pp.20-25
    • /
    • 2006
  • Objective : The authors analyze prospectively the result of transcranial doppler[TCD] in normal pressure hydrocephalus and compared its cerebral blood flow parameters to radionuclide cerebrospinal fluid[CSF] flow study, postoperative brain computed tomography[CT] findings and clinical outcome, and studied the relationship between cerebral hemodynamics and clinical performance. Methods : Twenty five patients with hydrocephalus undertook pre- and post-operative TCD but only preoperative CSF flow study was performed. Mean flow velocity[Vm], pulsatility index[PI] and resistance index[RI] were assessed through TCD and changes in ventricle size and cortical gyral atrophy were checked through brain CT. Results : Postoperative hydrocephalus showed an increase in Vm[ACA P=0.037, MCA P=0.034], decrease in PI[ACA P=0.019, MCA P=0.017] and decrease in RI [ACA P=0.017, MCA P=0.021] compared to preoperative TCD parameters in the postoperative improvement group. In the postoperative improvement group, postoperative TCD parameters correlated with CSF flow study grade [Vm : $R^2=-0.75$, PI : $R^2=0.86$, RI : $R^2=0.78$] and ventriculocranial ratio change correlated with PI change [$R^2=0.73$]. The convexity gyral atrophy and initial TCD parameters showed close relationship to outcome. Conclusion : PI and RI can be used as an indicator of post operative prognosis, and with the addition of CSF flow study values, can also be used as a tool to predict pre-op and post-op patient status and successful shunt surgery.

Saturable Disposition of Taurine in the Cerebrospinal Fluid of the Rat

  • Chung, Suk-Jae
    • Proceedings of the Korean Society of Applied Pharmacology
    • /
    • 1996.11a
    • /
    • pp.99-113
    • /
    • 1996
  • Taurine, a ${\beta}$-amino acid, plays an important role as a neuromodulator and is necessary for the normal development of the brain. Since de novo synthesis of taurine in the brain is minimal and in vivo studies suggest that taurine does not cross the blood-brain barrier, the blood-cerebrospinal fluid (CSF) barrier is likely to play a role in taurine transport between the central nervous system and the systemic circulation. Therefore, we examined in vivo elimination of taurine from the CSF in the rat to characterize in vivo kinetics of elimination for taurine from the CSF is consistent with the in vitro study. Using a stereotaxic device, cannulaes were placed into the lateral ventricle and the cisterna magna of the rat. Radio-labelled taurine and inulin (a marker of CSF flow) were injected into the lateral ventricle, and the concentrations of the labelled compounds in the CSF were monitored for up to 3 hrs in the cisterna magna. The apparent clearance of taurine from CSF was greater than the estimated CSF flow (p<0.005), indicating that there is a clearance process in addition to the CSF flow. Taurine distribution into the choroid plexus was at least 10 fold higher than that found in other brain areas (e.g., cerebellum, olfactory bulb and cortex). When unlabelled taurine was co-administered with radio-labelled taurine, the apparent clearance of the labeled taurine was reduced (p<0.01), suggesting a saturable disposition of taurine from CSF. Distribution of taurine into the choroid plexus, cerebellum, olfactory bulb and cortex was similarly diminished, indicating that the saturable uptake of taurine into these tissues is responsible for the non-linear disposition. A pharmacokinetic model involving first order elimination and saturable distribution described these data adequately. The Michaelis-Menten rate constant estimated from in vivo elimination study is similar to that obtained in the in vitro uptake experiment Collectively, our results demonstrate that taurine is transported in the choroid plexus via a taurine is cleared from the CSF via a saturable process. This process may be functionally relevant to taurine homeostasis in the brain.

  • PDF

Sodium Dependent Taurine Transport into the Choroid Plexus, the Blood-Cerebrospinal Fluid Barrier

  • Chung, Suk-Jae;Ramanathan, Vikram;Brett, Claire M.;Giacomini, Kathleen M.
    • Journal of Pharmaceutical Investigation
    • /
    • v.25 no.3
    • /
    • pp.7-20
    • /
    • 1995
  • Taurine, a ${\beta}-amino$ acid, plays an important role as a neuromodulator and is necessary for the normal development of the brain. Since de novo synthesis of taurine in the brain is minimal and in vivo studies suggest that taurine dose not cross the blood-brain barrier, we examined whether the choroid plexus, the blood-cerebrospinal fluid (CSF) barrier, plays a role in taurine transport in the central nervous system. The uptake of $[^3H]-taurine$ into ATP depleted choroid plexus from rabbit was substantially greater in the presence of an inwardly directed $Na^+$ gradient taurine accumulation was negligible. A transient in side-negative potential gradient enhanced the $Na^+-driven$ uptake of taurine into the tissue slices, suggesting that the transport process is electrogenic, $Na^+-driven$ taurine uptake was saturable with an estimated $V_{max}$ of $111\;{\pm}\;20.2\;nmole/g/15\;min$ and a $K_M\;of\;99.8{\pm}29.9\;{\mu}M$. The estimated coupling ratio of $Na^+$ and taurine was $1.80\;{\pm}\;0.122.$ $Na^+-dependent$ taurine uptake was significantly inhibited by ${\beta}-amino$ acids, but not by ${\alpha}-amino$ acids, indicating that the transporter is selective for ${\beta}-amino$ acids. Since it is known that the physiological concentration of taurine in the CSF is lower than that in the plasma, the active transport system we characterized may face the brush border (i.e., CSF facing) side of the choroid plexus and actively transport taurine out of the CSF. Therefore, we examined in vivo elimination of taurine from the CSF in the rat to determine whether elimination kinetics of taurine from the CSF is consistent with the in vitro study. Using a stereotaxic device, cannulaes were placed into the lateral ventricle and the cisterna magna of the rat. Radio-labelled taurine and inulin (a marker of CSF flow) were injected into the lateral ventricle, and the concentrations of the labelled compounds in the CSF were monitored for upto 3 hrs in the cisterna magna. The apparent clearance of taurine from CSF was greater than the estimated CSF flow (p<0.005) indicating that there is a clearance process in addition to the CSF flow. Taurine distribution into the choroid plexus was at least 10 fold higher than that found in other brain areas (e. g., cerebellum, olfactory bulb and cortex). When unlabelled taurine was co-administered with radio-labelled taurine, the apparent clearance of taurine was reduced (p<0.0l), suggesting a saturable disposition of taurine from CSF. Distribution of taurine into the choroid plexus, cerebellum, olfactory bulb and cortex was similarly diminished, indicating that the saturable uptake of taurine into these tissues is responsible for the non-linear disposition. A pharmacokinetic model involving first order elimination and saturable distribution described these data adequately. The Michaelis-Menten rate constant estimated from in vivo elimination study is similar to that obtained in the in vitro uptake experiment. Collectively, our results demonstrate that taurine is transported in the choroid plexus via a $Na^+-dependent,saturable$ and apparently ${\beta}-amino$ acid selective mechanism. This process may be functionally relevant to taurine homeostasis in the brain.

  • PDF

Multi-Layer Onlay Graft Using Hydroxyapatite Cement Placement without Cerebrospinal Fluid Diversion for Endoscopic Skull Base Reconstruction

  • Kim, Young-Hoon;Kang, Ho;Dho, Yun-Sik;Hwang, Kihwan;Joo, Jin-Deok;Kim, Yong Hwy
    • Journal of Korean Neurosurgical Society
    • /
    • v.64 no.4
    • /
    • pp.619-630
    • /
    • 2021
  • Objective : The skull base reconstruction step, which prevents cerebrospinal fluid (CSF) leakage, is one of the most challenging steps in endoscopic skull base surgery (ESS). The purpose of this study was to assess the outcomes and complications of a reconstruction technique for immediate CSF leakage repair using multiple onlay grafts following ESS. Methods : A total of 230 consecutive patients who underwent skull base reconstruction using multiple onlay grafts with fibrin sealant patch (FSP), hydroxyapatite cement (HAC), and pedicled nasoseptal flap (PNF) for high-flow CSF leakage following ESS at three institutions were enrolled. We retrospectively reviewed the medical and radiological records to analyze the preoperative features and postoperative results. Results : The diagnoses included craniopharyngioma (46.8%), meningioma (34.0%), pituitary adenoma (5.3%), chordoma (1.6%), Rathke's cleft cyst (1.1%) and others (n=21, 11.2%). The trans-planum/tuberculum approach (94.3%) was the most commonly adapted surgical method, followed by the trans-sellar and transclival approaches. The third ventricle was opened in 78 patients (41.5%). Lumbar CSF drainage was not performed postoperatively in any of the patients. Postoperative CSF leakage occurred in four patients (1.7%) due to technical mistakes and were repaired with the same technique. However, postoperative meningitis occurred in 13.5% (n=31) of the patients, but no microorganisms were identified. The median latency to the diagnosis of meningitis was 8 days (range, 2-38). CSF leakage was the unique risk factor for postoperative meningitis (p<0.001). Conclusion : The use of multiple onlay grafts with FSP, HAC, and PNF is a reliable reconstruction technique that provides immediate and complete CSF leakage repair and mucosal grafting on the skull base without the need to harvest autologous tissue or perform postoperative CSF diversion. However, postoperative meningitis should be monitored carefully.

Plasma G-CSF and GM-CSF Concentration and Amount of Their Receptors on the Granulocyte in Kawasaki Disease (가와사키병 환아의 혈장내 G-CSF와 GM-CSF 농도 및 과립구에서의 이들 수용체의 발현 변화)

  • Yoo, Young-Kyoung;Lee, Gibum;Kim, Hyun-Hee;Kim, Soo-Young;Kim, You-Jeong;Lee, Wonbae
    • Clinical and Experimental Pediatrics
    • /
    • v.46 no.4
    • /
    • pp.376-381
    • /
    • 2003
  • Purpose : This study aimed to demonstrate the possible pathogenesis of granulopoiesis in patients of Kawasaki disease(KD) using quantitative analysis of G-CSF, GM-CSF and their CSFr. Methods : The plasma levels of G-CSF, GM-CSF, G-CSFr and GM-CSFr were studied in 14 patients in the acute phase of KD; 13 children with normal peripheral white blood cell counts were used as the normal control group. The plasma concentration of G-CSF, GM-CSF were analyzed by ELISA. The G-CSFr and GM-CSFr on the peripheral granulocytes were analyzed by a quantitative flow cytometric assay and QuantiBRITE, and the quantitative changes of receptors which did not combine with G-CSF and GM-CSF were measured. Results : The total number of leukocytes in KD was similar to normal control group, but the leukocytes increased according to the number of neutrophils. The plasma concentration of G-CSF were decreased similar to normal control group(P=0.133), but that of GM-CSF decreased more than the normal control group(P=0.227). The quantity of G-CSFr, GM-CSFr were revealed to be no less than the normal control(P=0.721, P=0.912). After incubation with excessive G-CSF, the expressed G-CSFr on the neutrophils were decreased in both groups(P=0.554). The quantities of expressions of GM-CSFr on the neutrophil after incubation with the excessive GM-CSF were always increased in both groups(P=0.255). The amount of GM-CSFr of neutrophils are in proportion to total white blood cells (r=0.788, P=0.035), but it wasn't in the case of KD(P=0.644). Conclusion : The leukocytosis in KD that mediated by increasing neutrophil was not correlated with the plasma concentrations of G-CSF and GM-CSF, and the amount of expression of G-CSFr and GM-CSFr on granulocyte. It is possible that the reduction of concentration of GM-CSF results by increasing the active GM-CSFr.

Plasma G-CSF and GM-CSF Concentrations and Expression of their Receptors on the Granulocyte in Children with Leukocytosis (백혈구 증가증 환아의 혈장내 G-CSF와 GM-CSF의 농도 및 과립구에서의 이들 수용체의 발현)

  • Choi, Won Seok;Ryu, Kyung Hwan;Kim, You Jeong;Kim, So Young;Kim, Hyun Hee;Lee, Wonbae
    • Clinical and Experimental Pediatrics
    • /
    • v.46 no.3
    • /
    • pp.271-276
    • /
    • 2003
  • Purpose : Granulocyte-colony stimulating factor(G-CSF) and granulocyte macrophage-colony stimulating factor(GM-CSF) are principal cytokines in granulopoiesis and their physiologic effects are mediated through binding to specific cell surface receptors. Although it is known that the level of serum G-CSF and GM-CSF, and presentation of the receptors are increased in infectious diseases, there have been no studies to find the correlation between the granulopoiesis and leukocytosis. This study was designed to measure G-CSF and GM-CSF in leukocytosis and in control and to demonstrate the possible pathogenesis of granulopoiesis in leukocytosis using quantitative analysis of G-CSF, GM-CSF and their CSFr. Methods : The plasma levels of G-CSF, GM-CSF of 13 children without leukocytosis and 14 children with leukocytosis were measured. Counts of cell surface G-CSFr and GM-CSFr were measured by combining anti G-CSFr and anti GM-CSFr monoclonal antibodies to their respective receptors by using quantitative flow cytometric assay. Results : There was no significant difference betweeen the plasma concentration of G-CSF and GM-CSF in acute leukocytosis and in the control group. However, levels of G-CSFr in acute leukocytosis decreased significantly compared to the control(P=0.012) and the levels of GM-CSFr in both groups revealed no significant difference. Conclusion : Increase in the number of leukocyte in leukocytosis was mediated by increasing the number of neutrophil, and increased plasma concentration of G-CSF may be the cause of neutrophilia. But GM-CSF did not have any influence on leukocytosis.

Analysis of Design Parameters For Shunt Valve and Anti-Siphon Device Used to Treat Patients with Hydrocephalus

  • Lee, Chong-Sun;Jang, Jong-Yun;Suh, Chang-Min
    • Journal of Mechanical Science and Technology
    • /
    • v.15 no.7
    • /
    • pp.1061-1071
    • /
    • 2001
  • The present study investigated design parameters of shunt valves and anti-siphon device used to treat patients with hydrocephalus. The shunt valve controls drainage of cerebrospinal fluid (CSF) through passive deflection of a thin and small diaphragm. The anti-siphon device(ASD) is optionally connected to the valve to prevent overdrainage when the patients are in the standing position. The major design parameters influencing pressure-flow characteristics of the shunt valve were analyzed using ANSYS structural program. Experiments were performed on the commercially available valves and showed good agreements with the computer simulation. The results of the study indicated that predeflection of the shunt valve diaphragm is an important design parameter to determine the opening pressure of the valve. The predeflection was found to depend on the diaphragm tip height and could be adjusted by the diaphragm thickness and its elastic modulus. The major design parameters of the ASD were found to be the clearance (gap height) between the thin diaphragm and the flow orifice. Besides the gap height, the opening pressure of the ASD could be adjusted by the diaphragm thickness, its elastic modulus, area ratio of the diaphragm to the flow orifice. Based on the numerical simulation which considered the increased subcutaneous pressure introduced by the tissue capsule pressure on the implanted shunt valve system, optimum design parameters were proposed for the ASD.