• Title/Summary/Keyword: CS-8000

Search Result 8, Processing Time 0.024 seconds

Evaluation of Dose Distribution Using a Radiophotoluminescence Glass Dosimeter in Biobeam8000 Gamma Irradiation Device (유리선량계를 이용한 Biobeam8000 감마선 조사장치의 선량평가)

  • Shin, Sang-Hun;Lee, Sung-Hyun;Son, Ki-Hong;Lee, Hyun-Ho;Kim, Kum-Bae;Jung, Hai-Jo;Ji, Young-Hoon
    • Progress in Medical Physics
    • /
    • v.22 no.4
    • /
    • pp.198-205
    • /
    • 2011
  • Gamma irradiator is widely used for cell, animal experiment, irradiation for blood, dose measurement, and education. Biobeam8000 gamma irradiator (STS Steuerungstechnik &. Strahlenschutz GmbH, Braunschweig, Germany, Cs137, 81.4 TBq) that KIRAMS (Korea Institute of Radiological and Medical Science) has is a irradiation device that enables to be used in large-capacity of 7.5 L and extensive area. Cs-137 source moves range of 24 cm back-and-forth in a regular cycle in beaker for uniform irradiation and a beaker that puts a specimen like existing radiation irradiator such as Gammacell3000 rotates $360^{\circ}$ during irradiation. Precise dose information according to the location of radiation source would be needed because of the movement of radiation source, whereas radiation could be uniformly irradiated in comparison with existing gamma irradiator. In this study, dose distribution of the inside beaker located in Biomeam8000 gamma irradiator was measured using glass dosimeter, and dose evaluation and distribution regarding dose linearity and dose reproducibility were implemented based on measurement results. This aims to show guideline for efficient use of irradiator based on measurement result when doing experiment or radiation exposure.

Fundamental study on volume reduction of cesium contaminated soil by using magnetic force-assisted selection pipe

  • Nishimura, Ryosei;Akiyama, Yoko;Manabe, Yuichiro;Sato, Fuminobu
    • Progress in Superconductivity and Cryogenics
    • /
    • v.23 no.3
    • /
    • pp.26-31
    • /
    • 2021
  • Advanced classification of Cs contaminated soil by using a magnetic force-assisted selection pipe was investigated. A selection pipe is a device that sort particles depending on their particle size, based on the relationship between buoyancy, drag, and gravity force acting on the particles. Radioactive cesium is concentrated in small-particle size soil components with a large specific surface area. Hence, the volume of the Cs contaminated soil can be reduced by recycling the large-particle size soil components with low radioactive concentration. One of the problems of the selection pipe was that the radioactive concentration of the stayed soil in the selection pipe exceeds 8000 Bq/kg, which is the standard value of recycling of Cs contaminated soil, due to low classification accuracy. In this study, magnetic fields were applied to the lab-scale selection pipe from upper side to improve the classification accuracy and to reduce the radioactive concentration of the stayed soil.

A Study on the Underground Movement of Radionuclides(I) (방사성핵종의 지하이동 연구)

  • Hun Hwee Park;Kyong Won Han;Nak June Sung;Chul Soo Kim
    • Nuclear Engineering and Technology
    • /
    • v.16 no.2
    • /
    • pp.64-69
    • /
    • 1984
  • With regard to the radioactive waste disposal, adsorption properties and migration rates have been evaluated for Cs-137 and Sr-90 with the domestic clay sampled from Cnyang, Sanchong and Mooan. Sorption coefficients (Ksorp) were determined by batch experiments. The measured values of Ksorp were ranged from 8000 to 17,000 ml/gr for Cs-137 of 0.1$\mu$Ci/ml, and from 10,000 to 15,000m1/gr for Sr-90 of 0.l$\mu$Ci/ml. Remarkably, Mooan clay showed lower values of Ksorp than those of the others. This could be explained by the poor soprtion capacity of the quartz found only in the Mooan clay. For the quantitative analysis, sorption isotherm equations of Freundlich type were made with the obtained values of Ksorp. $C_{R}$=18.0 $C_{A}$$^{0.74}$ : Cs-137, $C_{R}$=0.84 $C_{A}$$^{0.45}$ : Sr-90. By introducing the BOX model combined with the above relationships, simulation of underground nuclide movement was carried out. The results showed that the domestic clays could be the effective backfill material for repositories.itories.ies.

  • PDF

The Results of Radiation Treatment in Carcinoma of the Uterine Cervix (자궁경암의 방사선치료 성적)

  • Lee, Myung-Za;Kim, Jung-Jin
    • Radiation Oncology Journal
    • /
    • v.3 no.2
    • /
    • pp.95-101
    • /
    • 1985
  • From July 1979 through March 1985,112 patients with carcinoma of the uterine cervix were treated by whole pelvis irradiation and intracavitary radiation with Cs-137. The treatment consisted of 3600rad-5200rad to the whole pelvis by parallel opposing portals, 5 days per week, 180-200rad per day. Parametrial boost with 400-800rad was given in 60 patients. 2 intracavitary Cs-137 radiation using TAO applicator were done with 7-10 days interval. Total treatment times were 40-65 days with average 52 days. Total dose of radiation to point A varied from 6820 to 10500rad with average 8388rad and to point B from 4850 to 6899ra0 with average 5898rad. All patients had follow up from 6 months to 75 months and median follow up of 31 months. $9(8\%)$ had stage $14(12.5\%)$ had stage IIa, $50(44.6\%)$ had stage IIb, $33(29.5\%)$ had stage III, $6(5.4\%)$ had stage IV. 110 patients had squamous cell carcinoma and 2 patients had adenocarcinoma. 5 year actuarial survival rates were $61.8\%$ for the entire group, $84.6\%$ for stage Ib,$77.8\%$ for stage IIa, $56.7\%$ for stage IIb, $60\%$ for stage III, $33.3\%$ for stage IV. RT dose to medial parametrium (point A) below 8000rad resulted in $7/18(38.9\%)$ failure (=death) in contrast to 25/94 $(26.5\%)$ failure with dose over 8000rad. RT dose to lateral parametrium (point B) below 6000ra0 yielded 20/63 $(34.9\%)$ failure compared to $10/49(20.4\%)$ failure with dose over 6000rad. Poor survival group of age were between 40-49 years with failure of $14/41(34.1\%)$. There was no increased failure rate below age of 40 with failure of $2111(13.9\%)$. The results suggest that survival is as good as other published data, and that higher doses over 8000rad to point A and 6000rad to point B should be delivered.

  • PDF

Rectal Injuries after Radiotherapy for Carcinoma of the Uterine Cervix (자궁경암(子宮頸癌) 방사선치료(放射線治療)에 의한 직장손상(直腸損傷))

  • Kim, Jung Jin
    • Radiation Oncology Journal
    • /
    • v.1 no.1
    • /
    • pp.103-109
    • /
    • 1983
  • 47 out of 56 cases of intact uterine cervix cancer treated by radiation at the Hanyang University Hospital were followed 18 months or more after treatment. (7 patients died before 18 months, 2 cases lost to follow-up). Age distribution reveal 5 cases in 30's, 18 cases in 40's, 17 cases in 50's, 7 cases in 60's. Histologically, all cases were squamous cell type except one case of adenocarcinoma. 1. 45 cases were treated by combined external Co-60 irradiation and intracavitary irradiation by Cs-137 small sources. 1 case was treated by external irradiation only, and 1 case by intracavitary only. 2. Rectal injuries were observed in 13 cased (27.6%), 4 cases in Grade 1, 8 cased in Grade 2 and 1 cases in Grade 3 which needed surgical management. 3. Average intervals of rectal injury following treatment was 9.2 months varying from 5 to 15 months. 4. Relation between rectal injury and point A dose reveal 6 cases between 7000-7999 rad and 6 cases between 8000-8999 rad and 1 case above 9000 rad. Even though there is no direct relation between point A dose and rectal injury, it is expected that rectal injury increases as point A dose increase. 5. In the normal condition, rectal injury can't be attributed to one major cause. Radiation dose, small source distribution, general condition of patients, local anatomy of the individual patient, history of PID and previous surgery, all play complex roles.

  • PDF

사용후연료의 건식처리 발생 hull 폐기물의 처리(II)

  • Kim, Jun-Hyeong;Kim, In-Tae
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2009.11a
    • /
    • pp.177-177
    • /
    • 2009
  • 사용후 핵연료의 건식처리 시 핵연료 다발을 절단하여 voloxidation 즉 휘발산화처리를 하면 고온에 의해 분리가 가능한 핵분열생성물의 분리와 우라늄의 산화에 의한 부피팽창으로 핵연료가 쪼개져서 입도가 작아지고 또한 핵연료가 피복재에서 쉽게 박리되게 된다. 그 결과 폐기물 처리 시에 발열핵종으로 폐기물의 저준위화시에 분리가 요망되는 Cs-137이 분리되는 장점이 있어 습식 재처리에 있어서도 바람직하다. 건식처리에 있어서는 voloxidation 으로 처리된 피복재에는 금속 지르코늄에 불순물로 함유된 우라늄의 의한 방사화 생성물과 피복재 표변에 부착/침투한 방사화 생성물이 방사능을 갖게 된다. 이러한 부착된 TRU 잔류물은 통상 1% 미만으로 알파핵종의 방사능이 원자로에서 배출시에는 고준위 기준치의 약 100배 수준이었다가 30년 냉각후에는 약 1/10 수준으로 저준위화 된다. 지르코늄 금속중에 불순물로 함유된 우라늄의 방사화로 생기는 방사능은 고준위 기준치의 10% 를 넘지 않아서 피복재의 저준위화시에 고려할 필요가 없다. 발생열은 방출시에 고준위 기준치의 약 30 배 수준에서 5년 냉각후에는 기준치 미만이 되며 30년후에는 1/8000 정도로 저준위화 된다. 사용후 핵연료를 습시처리시에 발생하는 고준위 폐기물 중 약 1/4 가 피복재 (hull) 임을 고려하면 피복재의 저준위화는 사용후 연료의 건식처리에 있어서도 필수적인 과정이다. 특히 미국의 고준위 폐기물 처분장 Yucca Mt.의 포기와 우리의 고준위 폐기불 처분장이 공론화되는 싯점에서 저준위화는 매우 필요한 기술이다. 피복재는 방사성 물질의 침투두께가 0.01mm 미만이 대부분으로 저준위화에는 표면제염에 의한 저준위화가 주로 연구되어왔다. 표면제염에 의한 저준화는 이온 빔, laser에 의한 방법, dry ice 분사에 의한 방법이 시도되었다. 염소기체를 이용하여 지르코늄의 산화막을 제거하고자 하였으나 이 산화막이 안정적이어서 표변의 연마, 아크릴 칼의 사용, 표면을 눌러서 처리하는 등 전처리하여서 염소기체 반응에 의한 표면제거 실험이 가장 효과적임이 실험적 결과이었다. 이러한 전처리로 방사능을 1/100 수준으로 낮춘다고 하더라도 지르코늄 금속중에 불순물로 함유된 우라늄의 방사화에 의해 중저준위 폐기물의 범주에서 벗어나지 않으므로 재활용에는 제한이 있다. 또한 전처리(표면제염)하여 분리되는 고준위는 다른 고준위 염폐기물과 함께 처리하여 발열 핵종을 제거하면 중저준위화가 가능하다. 저준위화 된 hull폐기물에는 지르코늄 금속에 불순물로서 함유되어있는 우라늄에 의한 방사능을 갖는데 이들의 제거나 분리는 지르코늄 합금 피복재 원료물질에 불순물로 함유하는 우라늄의 함량을 낮추는 것과 유사한 문제이다. 현재까지 지르코늄합금 피복재에 우라늄이 불순물로 함유된 것을 사용함으로 원자로내에서 방사화되어서 방사능을 갖게 되는 것은 피할 수가 없다. 따라서 저준위화 처리된 피복재는 장기 보관으로 방사능을 감쇠시켜서 재활용하도록 한다. 처리 방법으로는 초고압 압축저장, 시멘트 고화, 합성암석에 의한 고화법 등으로 장기간 보관 후에 금속으로서 재활용한다.

  • PDF

Dosimetric Evaluation of a Small Intraoral X-ray Tube for Dental Imaging (치과용 초소형 X-선 튜브의 선량평가)

  • Ji, Yunseo;Kim, YeonWoo;Lee, Rena
    • Progress in Medical Physics
    • /
    • v.26 no.3
    • /
    • pp.160-167
    • /
    • 2015
  • Radiation exposure from medical diagnostic imaging procedures to patients is one of the most significant interests in diagnostic x-ray system. A miniature x-ray intraoral tube was developed for the first time in the world which can be inserted into the mouth for imaging. Dose evaluation should be carried out in order to utilize such an imaging device for clinical use. In this study, dose evaluation of the new x-ray unit was performed by 1) using a custom made in vivo Pig phantom, 2) determining exposure condition for the clinical use, and 3) measuring patient dose of the new system. On the basis of DRLs (Diagnostic Reference Level) recommended by KDFA (Korea Food & Drug Administration), the ESD (Entrance Skin Dose) and DAP (Dose Area Product) measurements for the new x-ray imaging device were designed and measured. The maximum voltage and current of the x-ray tubes used in this study were 55 kVp, and 300 mA. The active area of the detector was $72{\times}72mm$ with pixel size of $48{\mu}m$. To obtain the operating condition of the new system, pig jaw phantom images showing major tooth-associated tissues, such as clown, pulp cavity were acquired at 1 frame/sec. Changing the beam currents 20 to $80{\mu}A$, x-ray images of 50 frames were obtained for one beam current with optimum x-ray exposure setting. Pig jaw phantom images were acquired from two commercial x-ray imaging units and compared to the new x-ray device: CS 2100, Carestream Dental LLC and EXARO, HIOSSEN, Inc. Their exposure conditions were 60 kV, 7 mA, and 60 kV, 2 mA, respectively. Comparing the new x-ray device and conventional x-ray imaging units, images of the new x-ray device around teeth and their neighboring tissues turn out to be better in spite of its small x-ray field size. ESD of the new x-ray device was measured 1.369 mGy on the beam condition for the best image quality, 0.051 mAs, which is much less than DRLs recommended by IAEA (International Atomic Energy Agency) and KDFA, both. Its dose distribution in the x-ray field size was observed to be uniform with standard deviation of 5~10 %. DAP of the new x-ray device was $82.4mGy*cm^2$ less than DRL established by KDFA even though its x-ray field size was small. This study shows that the new x-ray imaging device offers better in image quality and lower radiation dose compared to the conventional intraoral units. In additions, methods and know-how for studies in x-ray features could be accumulated from this work.