• Title/Summary/Keyword: CROWN DENSITY

Search Result 184, Processing Time 0.019 seconds

Effects of Forest Tending Works on the Crown Fuel Characteristics of Pinus densiflora S. et Z. Stands in Korea (숲가꾸기 사업이 소나무림의 수관연료특성에 미치는 영향)

  • Kim, Sungyong;Lee, Byungdoo;Seo, Yeonok;Jang, Mina;Lee, Young Jin
    • Journal of Korean Society of Forest Science
    • /
    • v.100 no.3
    • /
    • pp.359-366
    • /
    • 2011
  • The objective of this study was to analyze the changes of crown fire hazard possibility from the effects of forest tending works (FTW) in Pinus densiflora stands in Korea. The study sites were located in Youngju (FTW) and Bonghwa (Control) areas. Ten representative sample trees were destructively felled at each areas to analyze the crown fuel characteristics. The results of this study showed that crown fuel moisture content in Youngju and Bonghwa areas were 103.6% and 104.4%, respectively. The needles and twigs with less than 1cm diameter accounted 50.3% of the total crown fuel load in Youngju area and 62.0% in Bonghwa area. On the other hand, it was observed in Youngju that the canopy bulk density was $0.11kg/m^3$ lower but have 1.3 m higher average canopy base height therefore having a possibility of lower crown fire hazard as compared to Bonghwa that had higher canopy bulk density and lower canopy base height.

Evaluation of Air Ion According to the Type of Ridge in Urban Park -Focused on Tangeumdae Park in ChungJu- (도심 산지형 공원 능선부 식생유형에 따른 공기이온 평가 - 충주시 탄금대 공원을 대상으로 -)

  • Kim, Jeong Ho;Lee, Sang Hoon;Yoon, Yong Han
    • Korean Journal of Environment and Ecology
    • /
    • v.33 no.5
    • /
    • pp.587-595
    • /
    • 2019
  • This study analyzed the influence of the environmental factor of each vegetation type in an urban, mountainous park (Tangeumdae Park in Chungju) on air ion. The measuring points were divided according to the tree species, diameter at breast height, crown density, and layered structure, and the meteorological factors and the air ion were measured. The results of the measurement showed the average generation of positive ions of $610.90{\pm}50.27ea/cm^3$, the average generation of negative ions of $723.58{\pm}64.25ea/cm^3$, and the air ion index of $1.19{\pm}0.10$. The results of the analysis, according to the vegetation type, are as follows. Firstly, the air ion varied according to the species, the chest diameter at breast height, and the layered structure, and was analyzed to be statistically significant. Secondly, the air ion and the vegetation type showed a positive correlation with the species, diameter at breast height, crown density, and layered structure. The cation showed a negative correlation with the species, diameter at breast height, and the crown density, and the anion showed a positive correlation with the species, the diameter at breast height, crown density, and layered structure. Thirdly, the ion index in ridges had a higher correlation with the vegetation type than the meteorological factors. In detail, the correlation was higher in the species > layered structure > crown density > diameter at breast height. This study had the limitation of evaluating air ions in the ridge. Therefore, future studies on air ion should consider both terrain structure and vegetation type and analyze the seasonal changes and comparison.

Electrochemical Immunosensing of GOx-labeled CRP Antigen on Capture Antibody Monolayer Immobilized on Calixcrown-5 SAMs

  • Jung, Hye-Sook;Song, Kum-Soo;Kim, Tai-Sun
    • Bulletin of the Korean Chemical Society
    • /
    • v.28 no.10
    • /
    • pp.1792-1796
    • /
    • 2007
  • Insulating effects on Au electrode according to the thickness and density of coated materials are well-known. To do electrochemical immunoassay reproducibly the glod electrode would be coated with self-assembled monolayers and antobodies. To get reproducibility, the antobody monolayer should be packed at highest density so that the amount of immobilized antibody at defined area should be the same. The calix[4]crown-5 SAMs could provide the basis for the antibodies to be immobilized reproducibly and at highest density. But the insulating effect would be highest too. We proved that the compactly packed protein monolayers on SAMs inhibited the electron transfer by block the free shuttling of redox molecules. The inhibition was minimized by inserting redox molecules in between the proteins during immobilization process. In this paper, we demonstrated that the calix[4]crown-5 SAMs would provide the protein monolayers with highest density and new method to minimize the insulating effect by inserted redox molecules in between the compactly packed protein monolayers.

Effects of Windbreak Planting on Crop Productivity for Agroforestry Practices in a Semi-Arid Region

  • Jo, Hyun-Kil;Park, Hye-Mi
    • Journal of Forest and Environmental Science
    • /
    • v.33 no.4
    • /
    • pp.348-354
    • /
    • 2017
  • Agroforestry has been practiced in arid and semi-arid regions for the purposes of preventing desertification and to increase income for locals. However, the intended effects of such practices have been limited due to strong winds and aridity. This study undertook multi-year monitoring of the productivity of income crops associated with windbreak planting in a semi-arid region of Mongolia, and explored strategies of windbreak planning to enhance the multi-purpose effects of agroforestry practices. The tree crown density of windbreak planting was on average 40% in one year after planting and 65% 2-3 years after, and thereby windspeeds were reduced by about 30% and 54%, respectively. Average windspeed reductions at leeward distances from the windbreak planting were approximately 60% within 3H (H=tree height), 50% at 5H, and 42% at 7-9H, presenting a pattern in which the farther the distance the less the reduction in windspeeds. The windbreak planting increased crop productivity by up to 6.8 times, compared to the productivity absent of windbreaks. Increases in the crown density as stated above resulted in increases of crop productivity by up to 3.6 times. Based on such results, this study proposed a model of windbreak planning as a typical land-use system of border windbreak planting or alternate windbreak planting of combining trees and income crops. The model also included tree planting with a crown density of 60% and allocation of income crops within a leeward distance of 5 times the height of the trees to reduce windspeeds by about 50%. The results from this study are applicable to practicing agroforestry not only at the study site but also in other regions worldwide where strong winds and aridity are problematic.

Changes of Spatial Distribution of Korean Red Pine Forest in Hallasan National Park (한라산국립공원 소나무림의 공간분포 변화)

  • Kim, Jong-Kab;Koh, Jung-Goon;Yim, Hyeong-Taek;Kim, Dong-Soon
    • Korean Journal of Environment and Ecology
    • /
    • v.33 no.5
    • /
    • pp.578-586
    • /
    • 2019
  • The purpose of this study was to investigate the change of spatial distribution of Korean red pine (Pinus densiflora Siebold & Zucc.) in Hallasan National Park by surveying the distribution and crown density and analyzing by the elevation, slope, orientation, and regional habitat in 2006 and 2015. The total area of the Korean red pine forest was 1,259.9 ha in 2015, which increased by 51.4 ha, or 4.1%, compared to 1,208.5 ha in 2006. For the past 10 years, the area of sparse density with crown density of 11% to 40% of Korean red pine increased by 59.8 ha, the area of moderate density with crown density of 41% to 70% increased by 59.0 ha, and the area of dense density with 71% or more crown density increased by 67.3 ha. In terms of the altitude above sea level, the Korean red pine forest area between 1,010 m and 1,400 m was the largest at 1,003.0 ha or 79.6% of the total area in 2015. The area between 1,100 m and 1,300 m increased, and the area of dense density decreased significantly while the areas of moderate density and sparse density increase. There was no notable change according to the land slope, and the area increased from 2006 regardless of the slope. By direction, 56.4% were distributed in the southwest and southeast directions centered on the south-facing slope with the increase of 27.8 ha over the 10 years while the northwest and northeast directions centered on the north-facing slope decreased by 7.6 ha. Regarding the distribution change of the Korean red pine forest by the region, the Yeongsil area showed an increase of 25.5 ha, or 49.6% of the total area increase, in 2006 while the Ibseog-oreum area including the right side on the Sanbeoleum mountain valley increased by 20.4 ha. The distribution in the Gaemideung area that includes Jogeundeule increased by 7.4 ha while that of Sogbat in Sungpanak Trail decreased by 1.9 ha. This study analyzed the changes in the distribution area and crown density of the Korean red pine forest according to the altitude, slope, direction, and regional habitat in Hallasan National Park. The expansion of Korean red pine forest distribution was limited to the areas where the grass and the shrub was the dominating vegetation structure, or the forest gap was created by the disturbance. On the other hand, the distribution area of the Korean red pine forest surrounded by deciduous broad-leaved forests or mixed vegetation structure is considered to result from the change in density more than the area due to competition with deciduous broad-leaved trees.

Crown Fuel Characteristics and Allometric Equations of Pinus densiflora Stands in Youngju Region (영주지역 소나무림의 수관연료특성 및 수관연료량 추정)

  • Kim, Sungyong;Lee, Byungdoo;Seo, Yeonok;Lee, Youngjin
    • Journal of Korean Society of Forest Science
    • /
    • v.100 no.2
    • /
    • pp.266-272
    • /
    • 2011
  • This study was conducted to analyze the characteristics of crown fuel biomass and to develop allometric equations for the estimation of crown fuel biomass by subjectively categorized the crown component in Pinus densiflora stands. A total of ten representative trees were destructively sampled in Youngju region. Crown fuel were weighed separately for each fuel category by size class. The results of this study showed that foliar moisture content was 119% while the average crown moisture content was 105.3%. The crown fuel/total fuel loading ratio was 30%, needles and twigs with less than 1 cm diameter accounted 50.3% for its fuel/crown fuel loading ratio. Adjusted multiple coefficient of determination of suggested allometric equations ranged from 0.6846 to 0.9246 for crown fuel biomass, 0.8308 for crown volume.

Spot Heating Technology Development for Strawberry Cultivated in a Greenhouse by Using Hot Water Pipe (온수배관을 이용한 시설딸기 부분난방기술 개발)

  • Moon, Jongpil;Kang, Geum-Choon;Kwon, Jin-Kyung;Paek, Yee;Lee, Tae Seok;Oh, Sung-Sik;Nam, Myeong-Hyeon
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.58 no.5
    • /
    • pp.71-79
    • /
    • 2016
  • The effects of spot heating for growing the strawberry cultivated in a plastic greenhouse during the winter that were estimated in Nonsan strawberry experiment station located in Chungnam. The temperature of water for heating was controlled by a electric hot water boiler and kept at the range of $22{\sim}24^{\circ}C$. Heating pipes were set up in root zone for root zone heating and very close to crown for crown heating. Spot heating effects were estimated by applying spot heating system in three test factors of heating root zone, crown only and crown plus root zone. The material for crown heating pipe was white low density polyethylene and the nominal diameter of that pipe was 16 mm. The material for root zone heating pipe was flexible stainless steel and the nominal diameter of that pipe was 15A. The flow rate of heating water circulation was 480 L/h and water circulation lasted for all day long. Temperatures, harvest yield by test beds were surveyed from Nov. 10, 2013 to Apr. 29, 2014. The temperature of crown spot for crown heating bed was at the range of $13.0{\sim}17.0^{\circ}C$ during the night and that of crown spot in control bed was at the range of $8.0{\sim}14.0^{\circ}C$. Also, the temperature of root zone for root zone heating bed was at the range of $18{\sim}21.0^{\circ}C$ and that of root zone in control bed was at the range of $13.0{\sim}15.0^{\circ}C$. The cumulative yield growth rate in earlier harvest period (from Dec. 20 to Mar. 15) of crown heating bed was 43% compared with that of control bed and the cumulative yield of crown plus root zone heating bed was 39 % and that of root zone heating bed was 39 %.

Responses of different phytoelements to habitat light level and their dynamic convergence towards crown development of Aucuba japonica Thunb. var. japonica

  • Ali, Md. Sohrab;Kikuzawa, Kihachiro
    • Journal of Ecology and Environment
    • /
    • v.35 no.3
    • /
    • pp.177-188
    • /
    • 2012
  • We analyzed crown development in Aucuba japonica Thunb. var. japonica resulting from the responses of phytoelements to habitat light conditions over a long period of time. Over the years, the degree of extension unit (EU) dimorphism and the degree of anisophylly were higher under shaded conditions than in brighter conditions. An overall temporally increasing pattern in the degree of EU dimorphism was found while no clear-cut trend was found in the case of anisophylly. EU length and number of leaves per EU co-varied in a spatio-temporal context. The number of terminal buds and their sizes acted as the key initiators of morphological differences of phytoelements which were further amplified following bud break. Leaf area density was displayed mostly in the apex peripheral layer of the crown and the apex layer received most of the incident light. There was a tradeoff between annual leaf production and mean leaf size. Depending on the heterogeneity of irradiance level within a crown, correlative growth inhibition caused higher EU mortality at brighter sites. Due to high mortality, shorter EUs had a mere role in the construction of structural framework of the crown except for the formation of some gaps. There was a strong convergence of EU dimorphism, anisophylly, EU extension growth and variations in leaf size towards formation of functional crown to reduce potential self-shading. Depending on the irradiance level, Aucuba japonica Thunb. var. japonica showed two different modes of crown expansion. At the brighter sites, individual crown expansion was progressive while at the darker sites, individual crown expanded in a diminishing manner and maintained a stable size. A plant's "growth diminishing phase" appeared earlier at shaded sites than brighter sites.

Studies on Ion-Selective Crown Ether Dyes (이온선택성 크라운 에테르 염료에 관한 연구)

  • Sam-Woo Kang;Chong-Min Park;Won-Fae Koo;Keun-Jae Kim;Soo-Min Lee;Choo-Hwan Chang
    • Journal of the Korean Chemical Society
    • /
    • v.32 no.5
    • /
    • pp.443-451
    • /
    • 1988
  • New crown ether dye-Ⅰ and dye-Ⅱ having an azo group(-N=N-) were synthesized from monobenzo-15-crown-5 and dibenzo-18-crown-6. These dyes showed ${\lambda}_{max}$ of 377 and 383nm respectively. The complexes of alkali metal ions ($Na^+$, $K^+$, $Cs^+$) with dye ligands showed band shift (390~400nm) and intensity increased. For a given anion, the extraction constants are in the order of $K^+$ < $Cs^+$ < $Na^+$ for dye-Ⅰ and $Cs^+$ < $Na^+$ < $K^+$ for dye-Ⅱ. These results show that the selectivity of crown ethers toward the alkali metal ions is dependant on the charge density of cation and the size of crown ether cavity. For a given cation, the order of the extraction constant is $Cl^-$ < $Br^-$ < $I^-$ < picrate. This order coincides with the degree of anion solvation effect.

  • PDF

A Study on the Infinite Slope Safty Factor Applied to the Roots Cohesion (뿌리 점착력을 적용한 무한사면 안전률에 관한 연구)

  • Choi, Won-Il;Choi, Eun-Hwa;Suh, Jin-Won;Jeon, Seong-Kon
    • Journal of the Korean Geosynthetics Society
    • /
    • v.15 no.2
    • /
    • pp.13-24
    • /
    • 2016
  • The safety factor of an infinite slope tends to be analyzed as lower when the effects of root cohesion are not considered into the equation. Thus, it is essential to consider regional characteristics such as root cohesion and crown density in order to obtain a reasonable safety factor value. In this study, The safety factor of the landslide model, both before and after considering crown density and root cohesion, was calculated and a comparative analysis was carried out. The safety factor is increased by the effect of roots cohesion of the analysis results, the amount of increase in safety factor along the inclination of the slope angle has been analyzed with various things, the effect of reinforcing the roots cohesion, slope of the lower angle it was found that the higher the safety factor increase.