• Title/Summary/Keyword: CR-39

Search Result 425, Processing Time 0.042 seconds

Measurement of Radon Concentration in the near-surface Soil Gas by CR-39 Detectors (CR-39를 사용한 제주도지역 토양중의 라돈측정)

  • Kang, D.W.;Kim, H.G.
    • Journal of Radiation Protection and Research
    • /
    • v.13 no.2
    • /
    • pp.57-66
    • /
    • 1988
  • A series of experiments is performed to measure radon concentration in the near-surface soil gas at the four locations (Cheju-Si, Seoguipo-Si, Taejeong-eup, Seongsan-eup) in Cheju Island, using CR-39 detectors placed inside radon cups. Two types of radon cups are installed in shallow holes of about 15 cm in diameter and 50cm in depth. The optimum etching conditions, i.e., the concentration of NaOH solution, etchant temperature and etching time, are found to be 625N, $70^{\circ}C$ and 5.5 hours for CR-39 detectors. A typical conversion factor of radon cup is calculated as $$1track/mm^3{\cdot}30day=0.059Bq/{\ell}$$. Average radon concentrations over 30 days measured in Cheju Island from May 1, 1987 to April 23, 1988 are $3.1{\pm}0.3Bq/{\ell}$ for open radon cups and $1.7{\pm}0.2Bq/{\ell}$ for closed radon cups.

  • PDF

The Estimation Method and Application of UV-cut effect in Lens (렌즈에서 UV 차단효과의 평가방법 및 적용)

  • Kim, Yong-Geun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.6 no.1
    • /
    • pp.107-110
    • /
    • 2001
  • In order to estimate the UV-A line's cut efficiency it lens, it was measured the light transmittance in the 320~400nm wavelength regions. We obtained the area to integrate the light transmittance of standard CR-39 and sample in the 320~400nm wavelength regions and established ${\alpha}$, ${\beta}$ of UV-A line's cut efficiency by contrast its area. We obtained the absolute cut efficiency ${\alpha}$ CR=0.59 value of CR-39 Lens, and if ${\alpha}$ was the absolute cut efficiency value of the lens to estimate UV-A cut effect, the relative cut efficiency ${\beta}$ was $1.69{\alpha}$. It was obtained the absolute and the relative UV exclusion index through each $a=(1-{\alpha}){\times}100%$, $b=(1-{\beta}){\times}100%$.

  • PDF

Analysis of Absorbance for Tinted Dye Absorbed into Tinted Lenses by Spectrophotometric Method (분광광도법에 의한 칼라 렌즈 내 염색제에 대한 흡광도 분석)

  • Choi, Eun-Jung;Jung, Ju-Hyun
    • Journal of the Korean Chemical Society
    • /
    • v.53 no.6
    • /
    • pp.704-708
    • /
    • 2009
  • We studied absorbance of tinted dye absorbed into tinted lenses by Spectrophotometric method. Used lenses and tinted dye were CR-39 plastic optical lenses and Ons & $Lavas^{(R)}$ Blue, respectively. Absorbance values of tinted dye absorbed into tinted lenses were obtained from the differences of absorbance values between tinted lenses and CR-30 lenses. Average concentrations of tinted dye absorbed into tinted lenses were obtained from the mass differences between tinted lenses and CR-30 lenses. The relationship between absorbance and average concentration for tinted dye absorbed into tinted lenses was also confirmed to follow Beer’s law. The absorption coefficient calculated from the tangent of the calibration curve was determined to be a=0.983 $Lg^{-1}cm^{-1}$.

The Analysis of the UV cut-off effect of tinted lens and the Characteristic of UV tester (착색렌즈의 UV 차단효과와 UV TESTER 평가 분석)

  • Park, Moon Chan;Jung, Boo Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.7 no.2
    • /
    • pp.129-134
    • /
    • 2002
  • We obtained the UV cut-off effect of tinted CR-39 Ophthalmic lens with the respect of concentration of green, brown, blue color. First, we analyzed the UV spectrum of tinted CR-39 lens measured by Spectrophotometer and then compared the UV data by Spectrophotometer with UV data by UV tester used in an optician shop. The result obtained show that the UV cut-off effect is increased with color concentration of tinted CR-39 lens, and the transmittance of 0%~5% at 400nm by Spectrophotometer is correspondence with transmittance of 0% by UV tester.

  • PDF

Fabrication and Characteristics of Indium Tin Oxide Films on CR39 Substrate for OTFT

  • Kwon, Sung-Yeol
    • Transactions on Electrical and Electronic Materials
    • /
    • v.7 no.5
    • /
    • pp.267-270
    • /
    • 2006
  • The Indium tin oxide (ITO) films were deposited on CR39 substrate using DC magnetron sputtering. ITO thin films deposited at room temperature because CR39 substrates its glass-transition temperature of is $130^{\circ}C$. ITO thin films used bottom and top electrode and for organic thin film transparent transistor.(OTFT) ITO thin film electrodes electrical properties and optical transparency properties in the visible wavelength range (300 - 800 nm) strongly dependent on volume of oxygen percent. For the optimum resistivity and transparency of ITO thin film electrode achieved with a 75 W plasma power, 10 % volume of oxygen and a 27 nm/min deposition rate. Above 85 % transparency in the visible wavelength range (300 - 800 nm) measured without post annealing process and $9.83{times}10{-4}{\Omega}cm$ a low resistivity was measured thickness of 300 nm.

Fabrication and Characteristics of Indium Tin Oxide Films on Polycarbonates CR39 Substrate for OTFTs

  • Kwon, Sung-Yeol
    • Korean Journal of Materials Research
    • /
    • v.17 no.4
    • /
    • pp.232-235
    • /
    • 2007
  • Indium tin oxide (ITO) films were deposited on polycarbonate CR39 substrate using DC magnetron sputtering. ITO thin films were deposited at room temperature because glass-transition temperature of CR39 substrate is $130^{circ}C$ ITO thin films are used as bottom and top electrodes and for organic thin film transparent transistor (OTFT). The electrodes electrical properties of ITO thin films and their optical transparency properties in the visible wavelength range (300-800 nm) strongly depend on the volume of oxygen percent. The optimum resistivity and transparency of ITO thin film electrode was achieved with a 75 W plasma power, 10 % volume of oxygen and a 27 nm/min deposition rate. Above 85% transparency in the visible wavelength range (300-800 nm) was measured without post annealing process, and resistivity as low as $9.83{\times}^{TM}10^{-4}{\Omega}$ cm was measured at thickness of 300 nm.

Characterization of saturation of CR-39 detector at high alpha-particle fluence

  • Ghazaly, M. El;Hassan, Nabil M.
    • Nuclear Engineering and Technology
    • /
    • v.50 no.3
    • /
    • pp.432-438
    • /
    • 2018
  • The occurrence of saturation in the CR-39 detector reduces and limits its detection dynamic range; nevertheless, this range could be extended using spectroscopic techniques and by measuring the net bulk rate of the saturated CR-39 detector surface. CR-39 detectors were irradiated by 1.5 MeV high alpha-particle fluence varying from $0.06{\times}10^8$ to $7.36{\times}10^8\;alphas/cm^2$ from Am-241 source; thereafter, they were etched in a 6.25N NaOH solution at a temperature of $70^{\circ}C$ for different durations. Net bulk etch rate measurement of the 1.5 MeV alpha-irradiated CR-39 detector surface revealed that rate increases with increasing etching time and reaches its maximum value at the end of the alpha-particle range. It is also correlated with the alpha-particle fluence. The measurements of UV-Visible (UV-Vis) absorbance at 500 and 600 nm reveal that the absorbance is linearly correlated with the fluence of alpha particles at the etching times of 2 and 4 hour. For extended etching times of 6, 10, and 14.5 hour, the absorbance is saturated for fluence values of $4.05{\times}10^8$, $5.30{\times}10^8$, and $7.36{\times}10^8\;alphas/cm^2$. These new methods pave the way to extend the dynamic range of polymer-based solid state nuclear track detectors (SSNTDs) in measurement of high fluence of heavy ions as well as in radiation dosimetry.

Speciation of Heavy Metals in Sediments of the Polluted River (오염된 하천 저니에 함유된 중금속 존재형태)

  • 권오억
    • Journal of Environmental Health Sciences
    • /
    • v.22 no.2
    • /
    • pp.25-31
    • /
    • 1996
  • The species of four heavy metals (Cr, Cu, Ni and Pb) associated with sediments (viz exchangeable, carbonates, reducible, organic and residual fractions) were determined with respect to the particle sizes and depths at four locations of the lower Kumho river. In the exchangeable fraction, 3.7~19.52% of Ni and 2.8~14.81% of Pb were found, and in the carbonates fraction 2.12~19.43% of Ni and 1.39~15.42% of Pb were found. The reducible fraction retained about 8.66~44.93% of Cr, 0.41~9.79% of Cu, 17.38~35.74% of Ni and 9.5~44.89% of Pb. In the organic fraction about 0~21.06% of Cr, 2.95~35.74% of Cu, 0~14.66% of Ni and 0~10.65% of Pb were found. The residual fraction retained about 52.6~83.53% of Cr, 63.86~86.39% of Cu, 39.66~66.16% of Ni and 39.97~71.75% of Pb. The order of release or mobility of heavy metals was Ni > Pb > Cr > Cu. Mobile fraction of heavy metals by particle sizes (1.0~0.5 mm and 0.5~0.25 mm) was found to be higher in particle sizes 1.0~0.5 mm than that of 0.5~0.25 mm. The release or mobility of heavy metals by depths (0~5 cm, 5~10 cm and 10~15 cm) was found to be higher in the upper sediments than in the lower sediments, except Cu.

  • PDF