• Title/Summary/Keyword: CPEV

Search Result 3, Processing Time 0.019 seconds

A Study on the line characteristics and coverage of FLC-C VDSL system. (FLC-C VDSL 선로특성과 Coverage에 관한 연구)

  • 길계태;하종영;권순철;한권훈;신종원;임종대
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.25 no.3B
    • /
    • pp.446-455
    • /
    • 2000
  • In this paper, we analyzed the reach performance of the FLC-C VDSL system using 4-CAP modulation scheme. We measured the attenuation of VDSL lines and their noise characteristics, and calculated the channel capacity. And then, we evaluated the VDSL coverage fro each type of cables; CPEV 0.5mm, CPEV 0.65mm, UTP3 0.5mm, UTP5 0.5mm, FS 0.4mm, FS 0.5mm. In case that FLC-C VDSL modern transmits 25.92 Mbps data over a UTP5 0.5mm cable, the VDSL reach appears to be about 570mm.

  • PDF

Wideband Transmission Characteristics of Copper Cables (통신용 동(copper)케이블의 광대역 전송특성)

  • Oh Ho-Seok;Jung Kyoung-Hee;Lee Young-Tark
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2002.08a
    • /
    • pp.238-241
    • /
    • 2002
  • 기존 동(copper)케이블을 이용한 초고속 서비스 xDSL 기술이 점차 고주파수 대역을 사용하게 되었다. 전송매개체인 동케이블은 동선의 굵기 및 길이에 따라 주파수별 특성이 달라지게 되어 동케이블의 특성을 이해하는 것은 단말장치의 개발 및 운용측면에 매우 중요하다. 본 논문은 초고속서비스를 제공하는데 기본이 되는 동케이블 중에서 시내선로와 구내선로로 사용되는 JFFS, CPEV, SH, UTP, TIV 케이블을 대상으로 $1MHz{\sim}30MHz$ 대역의 손실, 특성임피던스, 근단누화 등을 측정하고 결과를 분석하였다.

  • PDF

Issues and Improvement Methods of the Bridge Tab in Customer Premises Telecommunications Facilities for High-Speed Communication Network (초고속통신망을 위한 구내통신 설로설비의 브릿지 탭의 문제점과 개선 방안)

  • Min, Gyeong-Ju;Hong, Jae-Hwan;Nam, Sang-Sig;Kim, Jeong-Ho
    • The KIPS Transactions:PartC
    • /
    • v.13C no.7 s.110
    • /
    • pp.881-888
    • /
    • 2006
  • The position of the bridged tap is determined by that of the outlet in most modern apartments, since most of the indoor wiring utilizes the bus wiring structure when deploying the indoor communication line. These bridged taps deteriorate transmission performance in the specific frequency at the time of high-speed multimedia communication, which uses a high frequency bandwidth, since the duality of return loss worsens and line attenuation increases rapidly. As a result, analysis on this phenomenon is required. In this study, the test model is created by modeling the intercommunication facility of the apartment that is the most representative residential house type, and by understanding the structure and the environment of the indoor wiring. Also, how the bridge tap affects performance is analyzed when the VDSL service is provided, so that problems of intercommunication lines can be identified and methods for improving the proper intercommunication line can be suggested, which is suitable for accommodating high-speed multimedia service of the future.