• 제목/요약/키워드: COP displacement

검색결과 44건 처리시간 0.016초

Development of high capacity stirling cryocooler

  • Ko, Junseok;Yeom, Hankil;Kim, Hyobong;Hong, Yong-Ju;In, Sehwan;Park, Seong-Je
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제17권3호
    • /
    • pp.51-56
    • /
    • 2015
  • Cryogenic cooling system for HTS electric power devices requires a reliable and efficient high-capacity cryocooler. A Striling cryocooler with a linear compressor can be a good candidate. It has advantages of low vibration and long maintenance cycle compared with a kinematic-driven Stirling cryocooler. In this study, we developed dual-opposed linear compressor of 12 kW electric input power with two 6 kW linear motors. Electrical performance of fabricated linear compressor is verified by experimental measurement of thrust constant. The developed Stirling cryocooler has gamma-type configuration. Piston and displacer are supported with flexure spring. A slit-type heat exchanger is adopted for cold and warm-end, and the generated heat is rejected by cooling water. In cooling performance test, waveforms of voltage, current, displacement and pressure are obtained and their amplitude and phase difference are analysed. Moreover, temperatures of cooling water, housing and linear motor are recorded and electric power parameters of driving circuit are also obtained. The developed Stirling cryocooler reaches to 47.8 K within 23.4 min. with no-load. From heat load tests, it shows cooling capacity of 440 W at 78.1 K with 6.45 kW of electric input power and 19.4 of % Carnot COP.

소형 냉장고에 대한 스크롤 압축기 적용성에 관한 연구 (A Study on the Applicability of a Scroll Type Compressor to Small Capacity Refrigerators)

  • 김유찬;김우영;김현진
    • 설비공학논문집
    • /
    • 제24권2호
    • /
    • pp.164-173
    • /
    • 2012
  • To study the applicability of a scroll type compressor to small capacity refrigerators, a R600a scroll compressor with algebraic scroll wrap has been designed. Its size and performance have been compared to a reciprocating type of the same displacement volume. By employing scroll wrap based on algebraic curve, high compression ratio can be accomplished without increasing the wrap angle much so that compact scroll may be obtained. Compared to a reciprocating one, the designed scroll compressor has diameter and height reduced by about 50% and 80%, respectively. By numerical simulation, it has been estimated that the scroll compressor provides 38.6% more cooling capacity than reciprocating type with 8.9% more power consumption, resulting in 27.3% increase in COP for ASHRAE low back pressure condition. With increasing the operating pressure ratio from 9.5 to 15.3, the overall compressor efficiency of the scroll compressor decreases from 72.6% to 65.2%, while that of the reciprocating compressor increases from 55.7% to 59.8%.

Kinematic Characteristics Based on Proficiency In Geoduepyeopchagi in Taekwondo Poomsae Koryo

  • So, Jae Moo;Kang, Sung-Sun;Hong, AhReum;Jung, Jong Min;Kim, Jai Jeong
    • 한국운동역학회지
    • /
    • 제26권4호
    • /
    • pp.343-351
    • /
    • 2016
  • Objective: The purpose of this study was to help improve game performance and provide preliminary data to enhance the efficiency of the kick and stability of the support foot by comparing the kinematic characteristics of the repeated side kick (geodeupyeopchagi) in poomsaeKoryo between expert and non-expert groups. Method: The subjects were divided into 2 groups according to proficiency in Taekwondo, an expert group and a non-expert group (n = 7 in each group), to observe the repeated side-kick technique. Four video cameras were set at a speed of 60 frames/sec and exposure time of 1/500 sec to measure the kinematic factors of the 2 groups. The Kwon3D XPprogramas used to collect and analyze three-dimensional spatial coordinates. Ground reaction force data were obtained through a force plate with a 1.200-Hz frequency. An independent samplesttest was performed, and statistical significance was defined as .05. The SPSS 18.0 software was used to calculate the mean and standard deviation of the kinematic factors and to identify the difference between the experts and non-experts. Results: The angular displacement of the hip joint in both the expert and non-expert groups showed statistical significance on E1 and E4 of the left support foot and E5 of the right foot (p<.05). The angle displacement of the knee joint in both groups showed statistical significance on E4 of the left support foot, and E1 and E2 of the right foot (p<.05). The angular velocity of the lower leg in both groups showed no statistical significance on the left support foot but showed statistical significance on E2 and E6 of the right foot (p<.05). The angular velocity of the foot in both groups showed no statistical significance on the left support foot but showed statistical significance on E2 of the right foot (p<.05). The vertical ground reaction force in both groups showed statistical significance on E2 (p<.05). The center of pressure in all directions in both groups showed statistical significance (p<.5). Conclusion: While performing the repeated side kick (geodeupyeopchagi), the experts maintainedconsistency and stability of the angle of the support leg while the kick foot moved high and fast. On the other hand, the angle of the support foot of non-experts appeared inconsistent, and the kick foot was raised, relying on the support leg, resulting in unstable and inaccurate movement.

양방향 말뚝선단재하시험에 의한 암반근입 현장타설말뚝의 하중-침하거동 분석 (Load-Settlement Behavior of Rock-socketed Drilled Shafts by Bi-directional Pile Load Test)

  • 설훈일;정상섬;한근택;김재영
    • 한국지반공학회논문집
    • /
    • 제24권11호
    • /
    • pp.61-70
    • /
    • 2008
  • 본 연구에서는 국내 4개 지역에서 시공된 총 10본의 대구경 암반 근입 현장타설말뚝의 양방향 말뚝 선단재하시험과 일반적인 말뚝두부 재하시험을 토대로 하중 재하방식에 따른 말뚝의 침하거동 및 하중전이 거동 특성을 분석하였다. 이로부터 양방향 재하하중을 받는 현장타설말뚝의 등가 말뚝 두부하중침하 거동을 고찰하곤 기존 등가 두부하중침하 곡선 산정방법과의 비교분석을 통하여 주면하중에 의해 추가적인 선단침하량의 영향정도를 분석하였다. 본 연구결과, 주면하중에 의해 발생되는 선단침하량을 고려한 하중전이해석(coupled load transfer analysis)을 통한 하중-침하량 예측값은 정재하 시험결과를 적절히 예측하는 것으로 나타났으나, 근사적 해석법을 통한 등가 하중-침하 곡선 및 일반적인 하중전이해식(uncoupled load transfer analysis)의 예측값은 정재하 시험결과에 비해 침하량을 과소 평가할 수 있음을 알 수 있었다. 하지만, 시험말뚝 근입부분의 암반층이 매우 단단할 경우 주면하중에 의한 선단침하량이 매우 작은 것으로 나타났다.