• Title/Summary/Keyword: COP

Search Result 1,209, Processing Time 0.028 seconds

Heat Exchanger Design of a Heat Pump System Using the Heated Effluent of Thermal Power Generation Plant as a Heat Source for Greenhouse Heating (화력발전소의 온배수를 열원으로 이용하는 시설원예 난방용 히트펌프 시스템의 열교환기 설계기준 설정)

  • Ryou, Young Sun;Kang, Youn Ku;Jang, Jae Kyung;Kim, Young Hwa;Kim, Jong Goo;Kang, Geum Chun
    • Journal of Bio-Environment Control
    • /
    • v.21 no.4
    • /
    • pp.372-378
    • /
    • 2012
  • This study was carried out in order to determine the optimum length of a roll type PE pipe heat exchanger employed in the water-to-water heat pump system using the waste heat of the heated effluent flowed out from thermal power generation plants as a heat source. And the heat pump system of 30 RT for an experimental test was designed and manufactured. And also PE pipes were employed to recover the waste heat from the heated effluent. The inside diameter of PE pipe heat exchanger was 20 mm, the thickness was 2 mm and the diameter of a roll was 1,000 mm. And from the results of this study, we found that the optimum length of PE pipe heat exchanger was 75 m per the heat pump capacity of 1.0 RT (3.51 kW) and then the heating COP of heat pump system was 3.8.

Economic Evaluation Algorithm of Island Micro-grid for Utility and Independent Power Producer (전력회사와 발전사업자 측면에서 도서지역용 마이크로그리드의 경제성평가 알고리즘)

  • Nam, Yang-Hyum;Lee, Hoo-Dong;Kim, Yu-Rim;Marito, Ferrira;Kim, Mi-Young;Rho, Dae-Seok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.7
    • /
    • pp.1032-1038
    • /
    • 2017
  • Recently, regulation on carbon emissions has been strengthened according to the new climate change convention (COP21) held in Paris, and then Korea has decided to reduce CO2 emissions by 37% until 2030. As one of countermeasures, the government has energetically performed demonstration projects of island micro-grid including solar power, wind power and energy storage system. However, in order to smoothly introduce island micro-grid, it is a critical issue to carry out the economic evaluation for power utility aspect and independent power producer aspect. Therefore, this paper proposes economic evaluation algorithms of island micro-grid which are based on the present worth method, considering cost and benefit factors in the aspect of both sides. Firstly, in case of power utility this paper proposes algorithm to estimate a period of return on investment according to the introduction capacity of distributed generators replacing diesel generator. And also, in case of independent power producer, this paper proposes evaluation algorithm to estimate weighting factor of SMP and benefit rate based on break-even point related with cost and benefit. From a case study result on real island micro-grid model, it is confirmed that proposed algorithms are useful and practical for the economic evaluation of island micro-grid.

Performance Characteristics of the Electrical Air Conditioning System for the Zero Emission Passenger Vehicle (무공해 승용 자동차의 냉방을 위한 전동식 냉방시스템 성능에 관한 연구)

  • Lee, Moo-Yeon;Cho, Chung-Won;Lee, Ho-Seong;Won, Jong-Phil
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.12
    • /
    • pp.5430-5437
    • /
    • 2011
  • The objective of this study is to investigate the cooling performances of the electrical air-conditioning system using electric driven scroll compressor for zero emission passenger vehicles. This air conditioner with air source was used R-134a as a refrigerant and installed in a real zero emission passenger vehicle for tests under various driving conditions. The cooling performance of the electrical air conditioner was affected by driving velocities and conditions of the tested vehicle. The condensing rate of the condenser during driving is better than that of the idle condition. The average cool down temperature in the cabin room decreased on average $5.2^{\circ}C$ with the increase of the outdoor temperature from $20.0^{\circ}C$ to $30.0^{\circ}C$. In addition, the cooling performances were sufficient for cooling loads of the tested passenger car under tested conditions.

A Study on the Cooling Characteristics Improvement of TMA-Water Clathrate Compound by Ethanol (에탄올에 의한 TMA-포접화합물의 냉각특성 개선에 대한 연구)

  • Lee, Jong-In;Kim, Chang-Oh
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.15 no.1
    • /
    • pp.23-28
    • /
    • 2007
  • This study aims to find out cooling characteristics of TMA(Tri-Methyl-Amine, $(CH_3)_3N$) 25wt%-water clathrate compound with ethanol($CH_3CH_2OH$) such as supercooling, phase change temperature and specific heat. For this purpose, ethanol is added as per weight concentration and cooling experiment is performed at $-6{\sim}-8^{\circ}C$, cooling heat source temperature, and it leads the following result. (1) Phase change temperature is decreased due to freezing point depression phenomenon. Especially, it is minimized as $3.8^{\circ}C$ according to cooling source temperature in case that 0.5wt% of ethanol is added. (2) If 0.5wt% of ethanol is added, average supercooling degree is $0.9^{\circ}C$ and minimum supercooling is 0.8, $0.7^{\circ}C$ according to cooling heat source temperature. The restraint effect of supercooling is shown. (3) Specific heat shows tendency to decrease if ethanol is added. It is $3.013{\sim}3.048\;kcal/kg^{\circ}C$ according to cooling heat source temperature if 0.5wt% of ethanol is added. Phase change temperature higher than that of water and inhibitory effect against supercooling can be confirmed through experimental study on cooling characteristics of TMA 25wt%-water clathrate compound by adding additive, ethanol. This can lead to shorten refrigerator operation time of low temperature latent heat storage system and improve COP of refrigerator and efficiency of overall system. Therefore energy can be saved and efficiency can be improved much more.

Leg Muscle Activity from the Perturbation of the Support during Gait (보행 시 지지 기반 급변에 대한 하지 근신경의 반응)

  • Shin, In-Sik;Chun, Young-Jin;Seo, Jung-Seok;Choi, Chi-Sun;Nam, Ki-Jung
    • Korean Journal of Applied Biomechanics
    • /
    • v.17 no.3
    • /
    • pp.147-154
    • /
    • 2007
  • This study's purpose is to investigate the effects on leg muscle activity caused by perturbation, using a trapdoor system during the support phase of gait for healthy adults (n = 6, height $177.5{\pm}5.5cm$, weight $81.0{\pm}9.5kg$, age $30.0{\pm}3.3yrs$). The trapdoor had the functional ability of causing inversion or eversion. The release time for the trapdoor was specified for two times, 0.3 and 0.5 seconds after heel contact. While altering these variables, EMG was recorded for the leg muscles (rectus femoris, biceps femoris, vastus lateralis, tibialis anterior, gastrocnemius, soleus). The following conclusions were derived. The steptime was longer for the 0.5s eversion than 0.3s inversion condition. So in order to regain stability after the perturbation the unsupporting leg reached forward rapidly. This quick reflex can be observed through the center of pressure (COP) and its rapid change in direction. The gastrocnemius was activated throughout the total experiment. There was a low amount of activity recorded in the rectus femoris, vastus lateralis and tibialis anterior except for the condition of inversion 0.3s. For most of the conditions, the highest average EMG peak values were recorded during the condition of inversion 0.3s. The iEMG patterns were similar for the conditions of inversion 0.3s and eversion 0.3s. To cope with the rapid change in these conditions, the biceps femoris was activated. During the experiment except for the condition of normal gait, the activity of the soleus and gastrocnemius was relatively high. Therefore, to prevent injury from perturbation of the lower leg strengthening of the soleus and gastrocnemius is required. Likewise to prevent injury to the thigh strengthening for the biceps femoris.

Analysis of Proper Sampling Duration in Foot Positions during Assessment of Quiet Stance Balance in the Elderly Women Using Center of Pressure (압력중심점을 이용한 고령 여성의 정적서기 균형평가 시발 위치에 따른 적정 샘플링 시간 분석)

  • Shin, Joong-Dal;Youm, Chang-Hong;Moon, Dae-Sung;Kim, Woo-Kyu;Park, Young-Hoon
    • Korean Journal of Applied Biomechanics
    • /
    • v.18 no.3
    • /
    • pp.23-31
    • /
    • 2008
  • The purpose of this study was to investigate proper sampling duration while executing quiet stance of feet together position and a preferred foot position with eyes open using COP variables through GRF system. The subjects participated in this study were twenty healthy elderly women individuals($68.9{\pm}6.8$ years). It represented that the sampling duration needed over 20 s in the FTP and over 60 s in the PFP during assessment of quiet stance. The sampling duration shorter than 20 s in the FTP and 60 s in the PFP may not provide the sample showing stability. Inversely if the sampling duration becomes longer, it can distort the sample showing stability. In the future, I expect more studies of the proper sampling duration through various groups and the study of characteristics of participants caused by more sampling duration.

World Wide Views on Climate and Energy 2015 in Korea as a Global Deliberative Governance ('지구적 숙의 거버넌스'로서 유엔기후변화협상에 관한 세계시민회의)

  • Lee, Young Hee;Jeong, In Kyung
    • Journal of Science and Technology Studies
    • /
    • v.15 no.2
    • /
    • pp.1-31
    • /
    • 2015
  • World Wide Views on Climate and Energy held on 6 June 2015 was a structured citizens' deliberative consultation forum involving 10,000 citizens in 77 countries, and South Korea was one of the participating countries. Citizen participants, selected to reflect the demographic diversity in their countries or regions, were given information beforehand and deliberated for a full day with other citizens and voted on an identical set of questions, designed to reflect policy controversies at the UN COP negotiations to be held in Paris on December 2015. This study, firstly, analyzes the backgrounds and purposes of World Wide Views on Climate and Energy and reports the WWViews event held in Seoul, Korea before examining the theoretical implication of it. And then, this study discusses about the features and opportunities of World Wide Views on Climate and Energy as a way of forming a global deliberative governance by focusing on deliberative democracy, citizen participatory governance, and global citizenship.

Joint Crediting Mechanism under the Paris Agreement and Its Implication to the Climate Policy in Korea

  • Jung, Tae Yong;Sohn, Jihyun
    • Journal of Climate Change Research
    • /
    • v.7 no.4
    • /
    • pp.373-381
    • /
    • 2016
  • Before the Conference of Parties (COP) 21 of the United Nations Framework Convention on Climate Change (UNFCCC) in 2015, most parties of UNFCCC had submitted their intended nationally determined contributions (INDCs) and to achieve their voluntary targets, some parties consider using international market mechanisms. As one of such mechanisms, Japan promoted its own bilateral mechanism called Joint Crediting Mechanism (JCM). In this study, feasibility studies and projects under JCM have been analyzed by project type, sector, country and region, which could provide some implications in designing Korea's future climate policy to achieve Korea's targets of 11.7% using international market mechanism in INDC. Since 2010, JCM has promoted 542 projects and feasibility studies in 44 countries according to the Institute for Global Environmental Strategies (IGES) database. Among 542 projects, about 80% were feasibility studies implying that JCM was more focused on project identification. However, current trends of JCM show that more projects will be soon implemented based on these feasibility studies. For sectoral categorization, projects were categorized into seven sectors-energy technology, energy efficiency, renewable energy, waste management, city, strategic planning and projects related to the country's efforts to reduce emissions from deforestation and forest degradation (REDD+). JCM projects were mitigation focused with more than 70% of projects were related to energy efficiency, renewable energy and energy technology. At the regional and country level, JCM is highly focused on Asia and especially, more than 100 projects were developed in Indonesia. Based on the analysis of JCM, in order to develop bilateral international mechanism for Korea, it is worthwhile to emphasize that Korea considers Asian countries as her partner. In addition, Korea may consider the collaboration with Multilateral Development Banks (MDBs) to implement projects identified by Korea and Asian partner countries. Furthermore, strategically, it is recommendable to develop jointly with Japan who has already capacity and networks with other Asian countries to mitigate GHG emissions. Such financial resources from MDBs and Japan may contribute to meet the 11.3% of GHG reduction target from abroad according to INDC of Korea.

An Experimental Study on the Performance Characteristics of a Multi Type Refrigerator Using R600a (R600a를 이용한 소형 멀티형 냉장고 시스템의 성능특성에 대한 실험적 연구)

  • Ahn, Ji-Hoon;Jang, Yong-Hee;Kim, Yong-Chan;Choi, Won-Seop;Oh, Seung-Whan;Kim, Chang-Nyeun;Lee, Jae-Seung
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.4
    • /
    • pp.222-228
    • /
    • 2009
  • Various types of refrigerators become popular in the market such as a common refrigerator, kimchi refrigerator and wine cellar. It is required to develop a multi type refrigerator combining these refrigerators to save space and energy consumption. In this study, the performance of a multi type refrigerator, which consists of one machine room and three evaporators, was measured in a bench type multi refrigerator. The multi type refrigerator was tested by varying the number of refrigerator cabinet, refrigerant charge, and temperature conditions. In addition, the multi type refrigerator with a suction line heat exchanger(SLHX) was tested to improve system performance. Based on the experimental data, the multi type refrigerator showed better performance than the conventional refrigerator(single type system). Besides, the COP of the single system increased from 1.0 to 1.37, and those of the dual and triple system increased from 1.29 to 1.39, and 1.22 to 1.51, respectively, by applying the SLHX.

The Comparison of Performance Characteristics in Refrigeration System using $NH_3$ and R22 ($NH_3$와 R22를 사용한 냉동장치의 성능특성 비교)

  • Ha Ok-Nam;Lee Kyu-Tae;Ha Kyung-Soo;Jeong Song-Tae;Kim Jin-Hyun;Hong Seong-In;Yun Kab-Sig;Kim Yang-Hyun;Kwon Il-Wook;Lee Jong-In
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.5
    • /
    • pp.377-383
    • /
    • 2006
  • Recently, production and use of Freon substances are restrained due to destruction of ozone layer and grobal warming. In this aspect of environmental problems, the best solution is to use the natural refrigerant such as ammonia. Thus, this study apply the $NH_3$ and R22 to study the performance characteristic from the superheat control and compare the energy efficiency of two refrigerants from the high performance. The condensing pressure of refrigeration system is increased from 1,500 kPa to 1,600 kPa and degree of superheat is increased from 0 to $10^{\circ}C$ at each condensing pressure. As the result of experiment, when comparing the each COP, we knew the $NH_3$ is suitable as the alternative refrigerant of the R22.