• Title/Summary/Keyword: COOLING EFFECT

Search Result 2,352, Processing Time 0.031 seconds

The verification about possibility of introducing Window to Floor Ratio as design index for building energy performance

  • Choi, Won-Ki;Lee, Yong-Jun;Lee, Hyun-Soo;Eom, Jae-Yong;Lee, Chung-Kook
    • KIEAE Journal
    • /
    • v.17 no.1
    • /
    • pp.23-28
    • /
    • 2017
  • Purpose: Many design index that are using in planning phase have been developed. The most popular things among them are Window to Wall Ratio and Surface to Volume Ratio. However there are some limits. Window to Wall Ratio cannot consider building size and Surface to Volume Ratio cannot do Window to Wall Ratio. Accordingly, in this paper, the Window to Floor Ratio was proposed that it can be considered both building size and Window to Wall Ratio. And analyzed correlation of energy demand. Method: For the test, 16 modules with the size of $6m{\times}6m{\times}4m$ were used to make 35 models with the same volume. The simulation was conducted to 945 cases using the window-to-wall ratio of 30, 50 and 70 % in three areas such as Seoul, Gwangju and Jeju and three kinds of windows. And IES_VE was used. Result: The findings above show that the Window to Floor Ratio that can be considered both building size and Window area have to become as design index. It was found out that design criteria with SHGC is necessary, not with the thermal performance (U-value). It is needed to additional analysis about residential building and the effect of 24-hours heating and cooling condition. It plans to carry out research to establish design indicators for climatic conditions in the country and building applications.

A Study on Efficiency Improvement and Optimization of Operating Characteristics of Pulsed $CO_2$ Laser System using Ring Blower (링 블로우를 이용한 펄스형 $CO_2$ 레이저 시스템의 효율 향상과 동작 특성에 관한 연구)

  • Kim, D.H.;Chung, H.J.;Park, S.J.;Joung, J.H.;Lee, D.H.;Kim, H.J.;Cho, J.S.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.05b
    • /
    • pp.57-60
    • /
    • 2000
  • In this paper, it is purpose to develop a pulsed $CO_2$ laser with stable output at pulse repetition rate range of 2 KHz. We used a IGBT as a switching device. The laser cavity was fabricated as an axial and water cooled type. It was used a ring blower to increase a cooling effect The laser performance characteristics as parameters, such as pulse repetition rate, gas pressure have been investigated. The experiment was done under 3 electrode-type instead of 2 electrode-type. To achieve 3 electrode-type, we used two pulse-transformers which is operated parallel. As a result, the maximum output was about 28 W at the total pressure of 20 Torr, the gas mixture $Co_2$:$N_2$:He=1:9:15 and the pulse repetition rate of 1300 Hz.

  • PDF

Analysis on the Thermal Comfort Aspect of a Locally-Cooled Room in Warm and Humid Environments : PPD-Based Evaluation of Human Responses (중온 고습 환경조건에서 부분적으로 냉방되는 실내의 열쾌적성에 대한 분석 : 인체반응에 대한 PPD 기준의 평가)

  • Kim, Bong-Hun;Seo, Seung-Rok
    • Journal of the Ergonomics Society of Korea
    • /
    • v.17 no.3
    • /
    • pp.41-59
    • /
    • 1998
  • Thermal comfort aspect of a locally-cooled target space in warm and humid environments(typically in the rainy summer season) was studied in view of PPD index. First. theoretical analyses were conducted to examine the effect of the governing parameters(such as air temperature, relative humidity and air velocity, etc.) using a computer model. Secondly, experimental investigations were also performed in a climatic room designed to simulate corresponding thermal conditions of outdoor environments. During the tests, temporal variation of PPD was recorded as functions of climatic variables(outdoor and indoor temperatures, relative humidity and air velocity) for the given human factors(metabolic heat generation and clothing). From both theoretical and experimental investigations, air temperature and air velocity were found to be the most dominant parameters affecting PPD of the target space. Results were summarized as: 1. Relative humidity of the locally-cooled target space tends to approach that of outdoor's as the space is subjected to an ON-OFF mode of cooling, since moisture potential of the two rooms reaches an equalized state as a result of moisture diffusion. 2. It was recognized that changes in relative humidity did not show any significance in view of thermal comfort as was reported in the previous studies, while variations of both temperature and air velocity caused relatively large changes in the degree of thermal comfort. 3. In-door environment should be evaluated in terms of PPD instead of relative humidity commonly recognized as an important climatic variable particularly in warm and humid environments.

  • PDF

CHARACTERISTICS OF THE FAIRCHILD 486 CCD AT MAIDANAK ASTRONOMICAL OBSERVATORY IN UZBEKISTAN (우즈베키스탄 Maidanak 천문대 Fairchild 486 CCD의 기본적인 특성)

  • Lim, Beom-Du;Sung, Hwan-Kyung;Karimov, R.;Ibrahimov, M.
    • Publications of The Korean Astronomical Society
    • /
    • v.23 no.1
    • /
    • pp.1-12
    • /
    • 2008
  • Understanding of the basic characteristics of an astronomical instrument is a prerequisite to obtaining reliable data from the instrument. We have analyzed more than 1,000 calibration images from the Fairchild 486 CCD (hereafter the Maidanak 4k CCD system) attached to the AZT-22 1.5m telescope at Maidanak Astronomical Observatory in Uzbekistan. The Maidanak 4k CCD system supports three readout modes through 1, 2, or 4 amplifiers. In most cases observers use 4-amplifier readout mode to save time. We have tested the stability and seasonal variation of zero levels and confirm that two quadrants of the images (Amp 1 & 2) show no appreciable seasonal variation. but the other two quadrants (Amp 3 & Amp 4) show an evident seasonal variation in the bias level. The Cryo Tiger, the cooling system used at the Maidanak 4k CCD system, maintains the CCD temperature at -108'E, and effectively suppresses the dark electrons. The mean value versus the variance plot of the flat images does not show the expected relation for an ideal Poisson noise distribution and this is attributed to the large variation in quantum efficiency between different pixels. In addition, we confirm that there is no appreciable difference in gain between readout amplifiers, but there is a large variation in quantum efficiency across CCD chip especially in U. Due to the finite length of shutter opening and closing time, the effective exposure time varies across the science images. We introduce two parameters to quantify the effect of this uneven illumination and present a method to remove these effects. We also present a method to remove the interference patterns appearing in the images obtained with longer wavelength filters and investigate the spatial variation of the point spread function.

Numerical Simulation on the Spreading and Heat Transfer of Ex-Vessel Core Melt in a Channel (전산해석을 이용한 원자로 노심 용융물의 노외 거동 및 열전달 특성 분석)

  • Ye, In-Soo;Ryu, Chang-Kook;Ha, Kwang-Soon;Song, Jin-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.4
    • /
    • pp.425-429
    • /
    • 2011
  • In the unlikely of nuclear reactor meltdown, the leaked core melt or corium must be contained in a device called core-catcher so that the corium can be cooled and stabilized. The ex-vessel behavior of corium involves complex physical and chemical mechanisms of flow propagation, heat transfer, and reactions with sacrificial substrates. In this study, the detailed characteristics of corium flow and heat transfer were investigated by using a commercial CFD code for VULCANO VE-U7 test reported in the literature. The volume-of-fluid (VOF) model was used to predict the interfacial surface formation of corium and the surrounding air, and the discrete ordinate model was adopted to calculate radiation between corium and the surroundings. It was found that cooling via radiation through the top surface of corium had a dominant effect on the temperature and viscosity profiles at the front of the corium flow.

Experimental Study of Heat/Mass Transfer in Rotating Cooling Passages with Discrete Ribs (단락 요철이 설치된 내부 냉각유로에서 회전에 따른 열/물질전달 특성 연구)

  • Kim Kyung Min;Kim Sang In;Lee Dong Ho;Cho Hyung Hee
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.5 s.236
    • /
    • pp.590-598
    • /
    • 2005
  • The present study has been conducted to investigate the effect of discrete ribs and rotation on heat/mass transfer characteristics in a two-pass square duct with $90^{\circ}-rib$ turbulators. The rib turbulator has a square cross section of 1.5 mm. The rib height-to-hydraulic diameter ratio $({e/D_{h})$ is 0.056, and the rib pitch-to-rib height ratio (p/e) is 10. The gap width is the same as the rib height. The rotation number ranges from 0.0 to 0.2 while Reynolds number is fixed to 10,000. In a stationary duct, the heat/mass transfer on the surfaces with discrete ribs is enhanced because the gap flow promotes local turbulence and flow mixing near the ribbed surface. In a rotating duct, the gap flow affects differently the heat/mass transfer on leading and trailing surfaces with discrete ribs. On the leading surface of the first pass, heat/mass transfer is increased due to the gap flow. On the trailing surface of the first pass, however, heat/mass transfer is decreased because the gap flow disturbs reattachment of main flow. The phenomenon, that is, the difference of heat transfer between the leading and the trailing surfaces is distinctly presented by rotation.

Efficiency and Comfort Properties of Silicon Solar Cell Applied Air Circulation Jacket according to the Incident Angle of Sunlight (실리콘 태양전지를 활용한 공기순환 의복의 태양광 입사각에 따른 효율성 및 쾌적성평가)

  • Lee, Ji-Yeon;Cho, A-Ra;Jung, Ye-Lee;Kim, Eun-Ae
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.33 no.11
    • /
    • pp.1806-1816
    • /
    • 2009
  • This study analyzes the efficiency of a solar cell attached to an air circulation jacket. A commercially available silicon solar panel was selected and attached at four spots where the body angle was $40-60^{\circ}$ and voltage ($V_{oc}$, V), current ($I_{sc}$, A), and output power (P, W) were measured to determine the efficiency. The solar panel was applied to the outer jacket that operates with two fans to increase the convection that lowers the body temperature. The heavy work of standing, walking, and sweeping of a street sweeper was simulated in the field test. The microclimate within the jacket (with or without a fan) was measured and the subjective thermal, humidity, and comfort sensations were surveyed. SPSS 12.0 statistical package was used for a t-test and Wilcoxon signed-rank test. The results show that the highest efficiency of the solar cell was at the incident angle of $60^{\circ}$ in terms of voltage, current and output power distribution. The microclimate temperature of the air circulation jacket decreased significantly with the high power of the fan and subjects felt cooler than the jacket with a fan at the incident angle of $60^{\circ}$. Air circulation jackets operated by a silicon solar panel showed a significant cooling effect on the wearers.

Effect of Monothioglycerol on ROS Inhibition, Mitochondrial Activity, and DNA Integrity in Frozen-thawed Miniature Pig Sperm (Monothiolglycerol이 동결 융해 후 미니돼지 정자의 활성산소 억제, 미토콘드리아 활성 그리고 DNA Integrity에 미치는 영향)

  • Park, Soo-Jung;Kim, Dae-Young
    • Journal of Embryo Transfer
    • /
    • v.28 no.3
    • /
    • pp.265-271
    • /
    • 2013
  • Cryopreservation and in vitro fertilization (IVF) protocols are important in genetic studies and applications to transgenic animals. Various studies about boar sperm cryopreservation have been studied for a long time. Those were about the use of extenders, the choice of sugars, the cooling and warming rates. The factors that influence the boar sperm are the dramatic changes in temperatures, osmotic and toxic stresses, and reactive oxygen species (ROS) generation. Among these factors, ROS generation is the main damage to DNA which is a principal genetic material and the most important for the practical applications. So we wondered whether ROS generation could be reduced. In previous study, monothioglycerol (MTG) was essential for the culture of embryo stem cells. Therefore we added MTG in the freezing extender based on lactose-egg yolk (LEY) with trehalose. For the assessment of the frozen-thawed sperm, we focused onmotility, membrane integrity and DNA damage. First, we used a computer-aided sperm analysis system for overall conditions of sperm such as motility and viability. Then we performed the sperm chromatin structure assay for DNA integrity and hypo-osmotic swelling test for membrane integrity. And our result showed the existence of MTG in the freezing extender caused less damage to DNA and higher motility in frozen-thawed boar sperm. Also we checked a relative antioxidant activity of MTG in modified Modena B extender. We concluded that this reagent can activate sperm mitochondria at MTG $0.2{\mu}M$, contribute to sperm motility and DNA integrity but there was no significant difference on membrane integrity. Also antioxidant activity of MTG in modified Modena B extender was proved.

Development of Variable Deposition manufacturing for Ethylene Vinyl Acettecopolymer (EVA를 이용한 가변 용착 쾌속 조형 공정의 개발)

  • Lee, Sang-Ho;Sin, Bo-Seong;Jeong, Jun-Ho;An, Dong-Gyu;Yang, Dong-Yeol
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.17 no.9
    • /
    • pp.189-195
    • /
    • 2000
  • RP techniques have their unique characteristics according to the working principles : star-stepped surface of parts due to layer-by-layer stacking low build speed caused by line-by-line solidification to fish one layer and post processing to improve surface finish etc The objective of this study is to propose a new RP technique Variable Deposition Mnanufacturing (VDM) which can make up for the disadvantages of the existing RP techniques and to develop an apparatus to implement the technique. The proposed process can greatly reduce the build time and improve the surface finish of parts generated. Experiments are carried out to obtain the range of temperature of molten material to maintain its fluidity and to investigate the effect of gas cooling on the preservation of the slopes. Some simple shapes such as a line-shape an S-shape and a circle-shape are fabricated from Ethylene Vinyl Acetatecopolymer(EVA) In order to examine the applicability of VDM to more general shapes a tensile specimen and a yo-yo shape were manufactured by the proposed RP method using EVA material as a trial approach. The current basic study shows a high potential of practical use of the proposed VDM process to prototyping of a general three-dimensional shape.

  • PDF

A Study on Characteristic of High Frequency Induction Heating for Local Heating (국부가열용 고주파 유도가열 특성에 관한 연구)

  • Jin, Hyung-Kook;Lee, Dong-Ju;Shin, Sang-Beom
    • Proceedings of the KWS Conference
    • /
    • 2010.05a
    • /
    • pp.60-60
    • /
    • 2010
  • Since the curved hull plate was made by a series of manufacturing process including cold bending, manual local heating and correction work, the accuracy of curved plate strongly depends on the proficiency of worker. So the demands on the automatic local heating system for curved hull plate have continuously increased and the various researches relevant to it have been performed. Generally, the heat sources used for local heating were flame and induction heat. In terms of initial cost, flame heating is in a better favorable position than induction heating. However, from the viewpoint of the control of heat, induction heating has more advantage. So the various researches related to apply the induction heating to the automatic forming system has been performed. The purpose of this study is to establish the proper capacity of high frequency induction heating system for forming the curved hull plate. In order to do it, the proper coil shape for local heating was designed and the efficiency of induction heating system was determined by comparing of temperature results obtained by FEA and experiment. With the results, the extensive FEA was performed to identify the effect of heated plate dimension, cooling method and the capacity of induction heating system on the amount of heat loss introduced by induction heating. Based on the results, the proper capacity of high frequency induction heating system was proposed.

  • PDF