A Study on the Multizone Modeling for Preventing Transmission of Air Borne Contagion (실내 미생물오염 전파방지를 위한 멀티존 모델링에 관한 연구)

  • Choi, Sang-Gon;Lee, Hyun-Woo;Hong, Jin-Kwan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.11
    • /
    • pp.933-940
    • /
    • 2006
  • In this study multi-zone modeling program CONTAM 2.4 developed by NIST is used for estimating the air disinfection rate of the interior of a room which is set up the indoor air disinfection system with filter and ultra violet germicidal irradiation (UVGI). Developed models those enable to predict the transmission of air home contagion such as bacteria and fungus generated in our daily life are useful model for designning air cleaning & ventilation system of building. Also, results indicate that these models are enable to compute the real situation that is almost impossible of carrying out experiment in an actual condition due to biohazard problems and suggest that engineers will use these models as a design tool for the future immune building system.

Indoor air quality and ventilation requirement in residential buildings: A case study of Tehran, Iran

  • Ataei, Abtin;Nowrouzi, Ali;Choi, Jun-Ki
    • Advances in environmental research
    • /
    • v.4 no.3
    • /
    • pp.143-153
    • /
    • 2015
  • The ventilation system is a key device to ensure both healthful indoor air quality (IAQ) and thermal comfort in buildings. The ventilation system should make the IAQ meet the standards such as ASHRAE 62. This study deals with a new approach to modeling the ventilation and IAQ requirement in residential buildings. In that approach, Elite software is used to calculate the air supply volume, and CONTAM model as a multi-zone and contaminant dispersal model is employed to estimate the contaminants' concentrations. Amongst various contaminants existing in the residential buildings, two main contaminates of carbon dioxide ($CO_2$) and carbon monoxide (CO) were considered. CO and $CO_2$ are generated mainly from combustion sources such as gas cooking and heating oven. In addition to the mentioned sources, $CO_2$ is generated from occupants' respirations. To show how that approach works, a sample house with the area of $80m^2$ located in Tehran was considered as an illustrative case study. The results showed that $CO_2$ concentration in the winter was higher than the acceptable level. Therefore, the air change rate (ACH) of 4.2 was required to lower the $CO_2$ concentration below the air quality threshold in the living room, and in the bedrooms, the rate of ventilation volume should be 11.2 ACH.

Effect of Lock Operations on Airtightness of Sliding and LS Window Systems (잠금장치 작동에 따른 미서기 및 LS 창호 시스템의 기밀성)

  • Park, Jong Jun;Yun, Yu Ra;Kim, Young Il;Chung, Kwang-Seop
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.9
    • /
    • pp.449-454
    • /
    • 2015
  • In this study, the effects of lock operations on the infiltration rates for the two window types sliding and lift sliding (LS) are investigated through experiment and simulation. The airtightness levels of the two window types-with locks both on and off-were measured according to the KS F 2292 Test method of airtightness that is used for windows and doors. The air-flow rates of both window types with the locks on for a pressure differential of 10 Pa are $1.98m^3/(m^2h)$ and $1.68m^3/(m^2h)$, respectively; with the locks off, the air-flow rates of the sliding and LS windows are $2.64m^3/(m^2h)$ and $5.83m^3/(m^2h)$, respectively, whereby the air-flow rates are 33% higher for sliding and 247% higher for LS. The air change per hour (ACH) was calculated using the ventilation-simulation software CONTAM. For the sliding window, the ACH changed from 0.45 to 0.57 when the lock was operated from on to off, representing an increase of 27%. For the LS window, the ACH changed from 0.29 to 0.81, showing an increase of 179%.