• Title/Summary/Keyword: COD removal

Search Result 1,129, Processing Time 0.036 seconds

Performance Evaluation of Anaerobic Bioreactors and Effects of Ammonia on Anaerobic Digestion in Treating Swine Wastewaters

  • Lee, Gook-Hee;Seo, Jun-Won;Kim, Jong-Soo
    • Korean Journal of Environmental Agriculture
    • /
    • v.25 no.3
    • /
    • pp.195-201
    • /
    • 2006
  • The operational characteristics of anaerobic bioreactors in treating swine wastewater were evaluated upto hydraulic retention time (HRT) of 1 day and organic loading rate (OLR) of $5.1kg-COD/m^3{\cdot}d$ for 200 days. The bioreactors were effective in treating swine wastewaters with COD removal efficiency of $78.9{\sim}81.5%$ and biogas generation of $0.39{\sim}0.59m^3/kg-COD_r$ at OLR of $1.1{\sim}2.2kg-COD/m^3{\cdot}d$. The two-stage ASBF anaerobic bioreactors was effective in treating different characteristics of swine wastewaters since they showed high and stable COD removal efficiency at high OLR due to effective retention of biomass by media and staging. The effects of ammonia on anaerobic digestion were investigated by operating two-stage ASBF reactors using swine wastewaters as influent without and with ammonia removal at HRT of $1{\sim}2$ days and OLR of $2.2{\sim}9.6kg-COD/m^3{\cdot}d$ for 250 days. The COD removal efficiency and biogas generation of two-stage ASBF reactors was decreased by increasing influent ammonia concentrations to 1,580 mg (T-N)/L with increasing OLR to $6.3kg-COD/m^3{\cdot}d$, while those were increased by maintaining influent ammonia concentrations below 340 mg (T-N)/L by MAP precipitation with increasing OLR to $9.6kg-COD/m^3{\cdot}d$. Initial inhibition of ammonia on anaerobic processes was observed at a concentration of 760 mg (T-N)/L and the COD removal efficiency and biogas generation dropped to 1/2 at ammonia concentration ranges of $1,540{\sim}1,870mg$ (T-N)/L. It is essential to remove ammonia in swine wastewaters to an initial inhibition level before anaerobic processes for the effective removal of COD.

The Treatment of Concentrated Organic Alcoholic Distillery Wastewater by the Fluidized-Bed Biofilm Reactor (생물막 유동층 반응기에 의한 주정공장의 고농도 유기성 폐수처리)

  • 김동석;장희재
    • KSBB Journal
    • /
    • v.6 no.4
    • /
    • pp.345-350
    • /
    • 1991
  • The purpose of this study is to investigate biomass characteristics and organic removal efficiency by changing superficial upflow velocity and organic loading rate in treating alcoholic distillery wastewater. Since the biomass concentration and the thickness of biofilm are very sensitive to superficial upflow velocity, a high concentration of biomass could be achieved by decreasing superficial upflow velocity that lowered the organic removal efficiency. Therefore, superficial upflow velocity should be controlled as to give optimum conditions and removal efficiency. Generally, activated sludge system shows 70% COD removal efficiency at$1.5kgCOD/m^3{\cdot}day$, but the fluidized-bed biofllm reactor shows 80% COD removal efficiency even at 6kgCOD/$m^2{\cdot}day$.

  • PDF

A Study on the Treatment of a High-Strength Organic Wastewater by the Tube Type Fixed Biofilter Process (엔통형 고정상 생물막법에 의한 고농도 유기성 폐수처리에 관한 연구)

  • 손종렬;장명배;문경환
    • Journal of Environmental Health Sciences
    • /
    • v.20 no.2
    • /
    • pp.22-27
    • /
    • 1994
  • This study is to discuss the factors influenced on the removal efficiency of a high-strength organic wastewaters investigated using the polypropyrene media which appropriate to attach microorganism in the tube type fixed biofilter reactor. The results obtained in the experiment were as follows: 1. The kinetics of reaction rate (k') were 0.125, 0.135, 0.155 varing initial COD 720, 1280, 1630 mg/l in batch reactor. 2. In the range of pH 4.0 ~12.0 was obtained the removal efficiency of COD higher than 85%. It was proved that variation of pH (4.0 ~12.0) was nothing to do with the removal efficiency of substrate in continuous reactor. 3. Temperature to obtain removal efficiency of COD higher than 85% was 10 ~ 40$\circ$C. Removal efficiency of COD was no less than those at high temperature. 4. In the continuous reactor, the volumetric loading of COD for removal efficiency higher than 95% had to be 0.5~1.5 kg COD/m$^3$.d below. And then the HRT was 8 hrs. 5. In comparison with the activated sludge process, the tube type fixed biofilter process was excellent in removal efficiency of substrate and sludge production rate.

  • PDF

The study of chemical treatment of pulp mill bleaching waste liquor using sea water (해수를 이용한 펄프공장 폐액의 화학적 처리에 관한 연구)

  • 정병곤;이헌모;윤종호
    • Journal of environmental and Sanitary engineering
    • /
    • v.12 no.1
    • /
    • pp.39-48
    • /
    • 1997
  • The study was conducted to know the possibility that the removal efficiency of organic and suspended solids(SS) could be increased by suppling of sea water and the optimum amount of sea water to be supplied treat bleaching waste water by lime coagulation settlement at pulp mill process. When the lime dosage was increased, the removal efficiency of COD and SS in the waste water was increased based on the removal efficiency of COD and SS. The lime dosage and removal efficiency was increased proportionally with the lime concentration of 4,000 mg/l, but the increase of removal efficiency was presented slightly above the 4,000mg/l. It was evaluated that the removal efficiencies of COD and SS could be increased and the requirement of lime dosage could be decreased by the sea water supplement. The removal efficiency of SS was most increased when the sea water supplement was 10% or more in the waste water. The removal efficiencies of COD was the best at 4% sea water excepting the dilution efficiency by sea water supplement.

  • PDF

Ammonia Effects on Anaerobic Digestion of Swine Wastewaters (양돈폐수의 혐기성 소화에 대한 암모니아의 영향)

  • Kim, Jong-Soo
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.10 no.1
    • /
    • pp.102-108
    • /
    • 2002
  • The effects of ammonia on mesophilic anaerobic digestion were investigated by operating lab-scale two-stage ASBF reactors using swine wastewaters as influent without and with ammonia removal at HRT of 1-2 days and OLR of $2.2{\sim}9.6kg-COD/m^3{\cdot}d$ for 250 days. The COD removal efficiency and biogas generation of two-stage ASBF reactors was decreased by increasing influent ammonia concentrations to 1,580 mg(T-N)/L with increasing OLR to $6.3kg-COD/m^3{\cdot}d$, while those were increased by maintaining influent ammonia concentrations below 340 mg(T-N)/L by MAP precipitation with increasing OLR to $9.6kg-COD/m^3{\cdot}d$. Initial inhibirion of ammonia on anaerobic processes was observed at a concentration of 760 mg(T-N)/L and the COD removal efficiency and biogas generation dropped to 1/2 at ammonia concentration ranges of 1,540~1,870 mg(T-N)/L. It is essential to remove ammonia in swine wastewaters to an initial inhibition level before anaerobic processes for the effective removal of COD.

  • PDF

Development of a Rotating Biological Contactor(RBC) Process for the Advanced Wastewater Treatment (회전원판(回轉圓板) 생물막(生物膜) 공법(工法)을 이용한 하(下)·폐수(廢水)의 고도처리(高度處理) 공정(工程) 개발(開發))

  • Kim, Eung Ho;Park, Jae Lo;Yoon, Jung Ro
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.8 no.2
    • /
    • pp.1-11
    • /
    • 1994
  • This study was conducted to develop a new RBC process available for the effective removal of organic matters and nitrogen in sewage. The RBC process for the oxidation organic compounds and nitrification was designed to occur at the 1st-stage and next-stage RBC respectively. Then nitrified water was recycled to the denitrifying RBC located at the lower part of the 1st-stage RBC. Some results were summarized as follows. 1. The loading limitation was represented as $60g{\cdot}COD/gm^2/day$ in experiment of simultaneous removal of organic matter and nitrogen. The maxmum COD % removal was 85% at the load $35g{\cdot}COD/m^2/day$. 2. The $NO_3-N$ % removal was approximately 80% at the load $60g{\cdot}COD/m^2/day$ and the maximum $NO_3-N$ remaval rate was $3.9g{\cdot}COD/m^2/day$ and the overall C/N ratio of 11.0 as required to achive 80% of $NO_3-N$% removal. 3.$NO_3-N$ removal rate was rapidly decreased above the load $7g{\cdot}NH_4{^+}-N/m^2/day$ and the maximum $NO_3-N$ removal rate was $3.7g{\cdot}NO_3-N/m^2/day$. 4. Irrespective of the recycle ratio, the COD % removal at the system of 2-stage RBC unit was nearly constant as 89% while the maximum one in the 1st-stage unit was 77% in the case of 50% recycle. 5. The maximum COD % removal in the 3-stage RBC system was 93% while 1st-stage one being 80%, under the $NH_4{^+}-N$ load of $7.4g/m^2{\cdot}d$. Also maximum percentage of nitrification and denitrification was 69% and 41% respectively, under the same $NH_4{^+}-N$ load.

  • PDF

A Study on the Simultaneous Removal of Organics and Nutrients in Upflow Packed Bed Column Reactor (상향류식 충전탑형 반응기에 의한 유기물 및 영양염류 동시 제거에 관한 연구)

    • KSBB Journal
    • /
    • v.18 no.3
    • /
    • pp.234-238
    • /
    • 2003
  • Biofilm process is preferred to activated sludge process in small domestic wastewater treatment plant because of its simplicity in operation and maintenance. Column reactor filled with waste ceramics and with waste plastics was used to remove pollutants in restaurant wastewater. COD removal at 18 hours of hydraulic retention time (HRT) gave 93.7%, COD removal during the experimental period, where maximum COD removal was observed. Under same condition, average removal of total nitrogen and total phosphorus were 82.3% and 25.9%, respectively Organic and nitrogen were efficiently removed with the HRT of 18 hours or more.

A study on the desulfurization wastewater treatment using Ferrate(VI) (Ferrate(VI)를 이용한 발전소 탈황폐수 처리에 관한 연구)

  • Jo, Eun-young;Park, Chan-gyu
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.31 no.4
    • /
    • pp.297-301
    • /
    • 2017
  • Wastewater treatment using ferrate (VI) solution is becoming a promising technology for several years, because it is high efficient and harmless technology. In this study, the ferrate (VI) solution was tested to treatment of desulfurization wastewater. The effluent from desulfurization wastewater treatment process of power plant was used as raw water, and the COD and T-N removal efficiency of ferrate(VI) solution were investigated. In the test, as the injection rate increased from 0.1 to 1.0%, the removal efficiency of COD also slightly increased, about 80% of COD were removed in 1.0% of injection rate. In the case of T-N, about 50% of T-N was removed in the condition of 1.0% of injection rate. The removal efficiency of COD and T-N also affected by reaction time, maximum removal efficiency was shown in 30 min of treatment. From these results, the wastewater treatment with ferrate(VI) solution can be great solutions for treatment of non-biodegradable pollutants in wastewater, especially for the 3rd treatment of wastewater.

Slaughterhouse wastewater treatment in a bamboo ring anaerobic fixed-bed reactor

  • Tritt, Wolfgang P.;Kang, Ho
    • Environmental Engineering Research
    • /
    • v.23 no.1
    • /
    • pp.70-75
    • /
    • 2018
  • A pilot scale anaerobic fixed-bed with a reactor volume of $2.8m^3$ was built to treat slaughterhouse wastewater. Bamboo rings were chosen as support media mainly because of their cheaper price in underdeveloped countries. Even with their lower porosity and specific surface, the reactor performance showed a maximum 95% COD removal efficiency at an organic loading rate (OLR) of $1kg\;COD/m^3-d$ with its corresponding hydraulic retention time (HRT) of 7.5 d. At a higher OLR of $4.0kg\;COD/m^3-d$, the COD removal efficiency of 75% was achieved with an HRT of 2 d. No big difference in COD removal efficiencies was found between the reactors operated in both upflow and downflow modes. Their operational behavior and effluent characteristics were similar. The effluent COD/TKN ratio of 6.67 at an OLR of $4.0kg\;COD/m^3-d$ was only marginal acceptable range for a subsequent biological denitrification process. Otherwise carbon supplementation is required at a lower OLR.

Nitrogen and Phosphorus Removal in Domestic Wastewater using SBR Process with Flow Changing Continuous Feed and Cyclic Draw (교대연속유입식 SBR 공정을 이용한 하수중의 질소 및 인 제거)

  • Seo, In-seok;Kim, Hong-suck;Kim, Youn-kwon;Kim, Ji-yeon
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.2
    • /
    • pp.203-208
    • /
    • 2006
  • A continuous feed and cyclic draw SBR process was developed to overcome flow rate fluctuation and to maximize organic matters utilization efficiency for nitrogen and phosphorus removal. The developed SBR process was operated with two parallel reactors. Influent was supplied to one reactor which was not obligately aerated. At the same time, the other reactor was just aerated without supplying influent. In addition this mode was changed periodically. Cycle time was 6hr and aeration time ratio($t_{aer}/t_{total}$) was 0.33, respectively. $COD_{cr}$ and SS removal efficiencies of 95% or higher were achieved. Nitrogen removal was so greatly influenced by influent $COD_{cr}/T-N$ ratio. At influent $COD_{cr}/T-N$ ratio of 5.7, removal efficiencies of ammonia-N, T-N and T-P were 96%, 78% and 55%, respectively. Influent $COD_{cr}/T-N$ of 4 or higher ratio was necessary to achieve 60% or higher nitrogen removal. Organic matters of influent was efficiently utilized in denitrification reaction and consumed COD has a good correlation with removed T-N(about 6.5 mgCOD/mgTN). Continuous feed and cyclic draw SBR process could be one of alternative processes for the removal of nutrients in rural area where $COD_{cr}/T-N$ ratio was low and fluctuation of flow rate was severe.