• 제목/요약/키워드: COD pollutants load

검색결과 76건 처리시간 0.022초

무심천(無心川) 수질(水質) 오염(汚染) 실태(實態)와 그 방지책(防止策);II. 계절별(季節別) 및 시간별(時間別) 현황(現況) (1989-1990)-수온, pH, DO, BOD, COD, SS, 탁도 및 BOD 부하량(負荷量) (Contamination of the Mushim-Cheon and its Countermeasure;II. The Status of the Seasonal and Hourly Contamination of the Water(1989${\sim}$1990)-Temperature, pH, DO, BOD, COD, SS, Turbidity, and BOD Load)

  • 이재구;김학남;경기성;곽희인
    • 한국환경농학회지
    • /
    • 제10권1호
    • /
    • pp.33-49
    • /
    • 1991
  • 청주시(淸州市)를 관류(貫流)하는 무심천(無心川)의 수질오염(水質汚染) 실태분석(實態分析)과 그 저감(低減) 방안(方案)을 모색(摸索)하기 위한 연구(硏究)의 일환으로 계절별(季節別) ['89년(年) 11월(月)(1차 시료(試料)), '90년(年) 2월(月)(2차 시료(試料)), 5월(月)(3차 시료(試料)) 및 8월(月)(4차 시료(試料))]과 시간별(時間別)['90년(年) 2월(月)(1차 시료(試料)), 5월(月)(2차 시료(試料))]로 채수(採水)한 시료(試料)를 분석(分析)하여 다음과 같은 결과(結果)를 얻었다. 1. 각(各) 계절별(季節別) 시료(試料)의 수온(水溫)은 1, 2, 3, 4차(次) 시료(試料) 각각(各各) $8.6-16.2^{\circ}C$, 8.3-25.2$^{\circ}C$, 18-26$^{\circ}C$, 24-32$^{\circ}C$ 범위(範圍)였고, 시간별(時間別) 시료(試料)의 경우(境遇)는 1차(次), 2차(次) 각각(各各) 0.4-16.4$^{\circ}C$, 16-19.5$^{\circ}C$ 범위(範圍)였다. 2. 무심천수(無心川水)의 pH는 연중(年中) pH 6.5-8.5 범위(範圍)이었다. 3. 용존산소(溶存酸素)(DO)는 특히 3차(次) 시료(試料)(1990년 5월 시료(試料))의 St 13 이하(以下)에서 1ppm 이하(以下)가 되어 농업용수(農業用水)(허용치(許容値) : 2ppm 이하(以上))로도 사용(使用)할 수 없는 수질(水質)이었다. 4. BOD와 COD는 대부분 무심천(無心川) 본류(本流)보다 하수유입구(下水流入口)에서 더 높았으며 특히 분뇨처리장(糞尿處理場) 배출구(排出口)(St 14-A)에서 BOD는 107∼680 ppm으로써 분뇨처리장 방류수(放流水)의 허용치(許容値)인 40ppm을 크게 초과(超過)하고 있으며, COD도 176∼635 ppm으로 매우 높았다. 또한 SS도 142-1, 900ppm으로써 분뇨처리장(糞尿處理場) 방류수(放流水)의 허용치(許容値)인 70 ppm보다 훨씬 높은 수치(數値)였다. 5. 무심천(無心川)의 수질(水質)은 본류(本流)의 조사(調査) 지점(地點)보다는 하수유입구(下水流入口)에서, 그리고 상류(上流)보다는 하류(下流)에서 크게 악화(惡化)되고 있어 하수종말처리시설(下水終末處理施設)의 시급(時急)한 설치운영(設置運營)과 분뇨처리시설(糞尿處理施設)의 확충(擴充)이 절실(切實)히 요망(要望)된다.

  • PDF

QUAL2E, QUAL2K 및 CAP 모델을 이용한 금강 하류 하천구간 정상상태 수질모델링 결과 비교 분석 (Comparative Analysis of QUAL2E, QUAL2K and CAP Steady State Water Quality Modeling Results in Downstream Areas of the Geum River, Korea)

  • 서동일;윤종욱;이재운
    • 상하수도학회지
    • /
    • 제22권1호
    • /
    • pp.121-129
    • /
    • 2008
  • 하천의 수질은 하천 흐름, 오염원 유입 그리고 하천내부의 수질변화 기작에 따라 변화한다. 일반적으로 하천의 수질모의는 시간의 흐름에 영향을 받지 않는 정상상태에 대하여 실시하나, 실제로 이러한 상황은 존재하지 않는 것이 현실이다. 따라서 하천의 수질상태에 대한 각종 정보가 정확하다고 하여도 수질모델에서 가정하는 근본적인 조건이 다른 경우 오차의 발생은 필연적인 사실이 된다. 본 연구는 하천의 수질모델링에 자주 사용되는 QUAL2E와 미국환경부에서 새로 개발하고 있는 QUAL2K 그리고 저자들이 개발한 CAP 수질모델을 금강의 대청댐 하류 약 30 km 구간에 대한 집중적인 현장 실측을 통해 확보한 자료를 이용하여 적용하여 모델링 결과를 비교하고 해당 지역의 수질모델링에 나타나는 오차의 원인을 밝혀내고자 수행되었다. 전체적으로 BOD5 및 COD의 경우 실측치보다 약간씩 낮게 모의되는 경향을 나타내었으며 TN과 TP의 경우 상대적으로 양호한 모의결과를 보이고 있다. 모델별로는 $BOD_5$와 TP의 경우 QUAL2E모델이, TN의 경우 QUAL2K모델이 가장 작은 오차를 나타내었으나 모델별로 오차정도의 차이가 유의성이 있다고 판단하기는 어렵다고 본다. 본 연구에서 모델링 오차의 가장 큰 원인에는 첫째, 정상상태 수질 모형이 하천의 수리동역학적 유동특성을 잘 반영하기 어렵다는 것과, 둘째, 현장에는 육안으로는 발견되지 않는 수많은 오염원이 존재하며 아직까지는 이를 체계적으로 추적하지 못하고 있다는 것, 셋째, 수질분석을 위해 하안에서 시료채취를 유입지천 또는 오염원이 완전하게 혼합되지 못한 상태에서 시행할 수 있는데 이에 대한 고려가 충분하지 못한 것을 들 수 있다.

오염총량관리를 위한 소하천 모니터링 자료의 특성 분석 (Analysis of Monitoring Characteristics of Small Stream for TMDL)

  • 하돈우;박승호;주성민;이기순;백종훈;정강영;이영재;김경현;김영석
    • 한국환경기술학회지
    • /
    • 제19권6호
    • /
    • pp.503-513
    • /
    • 2018
  • 영산강 수계의 오염총량관리 이행사항 평가 및 원활한 제도 운영을 위해 단위유역 내 행정구역경계에 해당되는 소하천에 대해 지속적으로 시행하는 있는 모니터링 자료를 토대로 특성을 분석하였다. 모니터링 해당기간(2011~2016년) 내 모니터링은 1분기에 비해 2분기 측정 횟수가 많아 목표수질 설정 및 평가 시 측정횟수 등을 고려해야 하며, 일반적 하천처럼 상류지역 보다 하류지역의 하천이 수질이 악화되어 있는 것으로 분석되었다. 더불어 모니터링 지점의 오염부하량을 산정한 결과 풍영정천, 삼포천 등에서 수질이 매우 악화되어 있는 것으로 분석되었다. 이는 유량 및 BOD, T-P의 농도가 높아 영산강 본류의 수질에 미치는 영향이 크므로 수질개선을 위해서는 각종 오염원의 관리가 필요한 것으로 분석되었다. 또한, 목표수질 대상항목인 BOD 및 T-P의 측정항목간의 연관성을 평가하기 위해 지점별로 상관분석을 한 결과 BOD는 COD, TOC와 연관성이 높게 나타나 유기물과 관련된 오염원의 배출에 의한 영향을 받는 것으로, T-P는 SS, COD와의 연관성이 높게 나타나 강우에 의한 유입의 영향을 받는 것으로 나타났다. 본 연구에서의 장기간 모니터링을 수행하여 축적된 수질자료를 분석하고 특성을 파악함으로써 해당수계의 수질관리에 효율적이고 과학적인 방안을 설계함에 있어 기초자료 및 방향을 제시할 수 있을 것으로 판단된다.

농업용 저수지 상류유역의 비점원오염 유출부하량 산정 - 고성저수지를 대상으로 - (Dischatge Loads of Nonpoint Source Pollutant in the Upper Watershed of Inigation Reservoir - Case Study of the Goseong Reservoir -)

  • 김진호;한국헌;류종수;정구복;권순국
    • 한국물환경학회지
    • /
    • 제23권3호
    • /
    • pp.324-331
    • /
    • 2007
  • This study was conducted to evaluate the influence of pollutant loads on the water quality in the Goseong reservoir from May 2005 to October 2006. Annual total runoff at the Goseong-cheon watershed was 968.0 mm in 2005, 382.6 mm in 2006, respectively. The mean concentration of BOD, COD and SS in the stream were 2.28, 6.03, 46.97 mg/L in rainy seasons and 0.95, 2.14, 6.05 mg/L in dry seasons at SWT C sub-watershed. Total-N concentrations ranged from 2.60 to 3.18 mg/L at SWT C sub-watershed, which was generally higher than the quality standard of agricultural water (1.0 mg/L). Total-P concentrations ranged from 0.044 to 0.130 mg/L at SWT C sub-watershed. Measured pollutant loads in the SWT C sub-watershed were 36.7 kg/day of BOD, 72.3 kg/day of T-N and 2.3 kg/day of T-P in 2005 at SWT C sub-watershed, 63.9 kg/day of BOD, 82.8 kg/day of T-N and 1.1 kg/day of T-P in 2006 at SWT C sub-watershed, respectively. In the analysis of the effluent characteristics for NPS pollutants, it appeared that the loading rates of effluent from SWT C watershed were, respectively, BOD 62.3%, T-N 69.6%, T-P 71.1%, SS 70.1% during the rainy season in 2006. The calculated T-N daily pollutant loadings by the unit loading factor method from each sub-watershed were much greater than observed, but the calculated T-P daily pollutant loadings much lesser than observed.

불투수면 저감기법의 유출량 및 오염부하량 저감 효과 분석 (Analysing the effect of impervious cover management techniques on the reduction of runoff and pollutant loads)

  • 박형석;최환규;정세웅
    • 환경영향평가
    • /
    • 제24권1호
    • /
    • pp.16-34
    • /
    • 2015
  • 불투수면(IC)이란 빗물 등의 강수가 토양 속으로 침투할 수 없는 포장 지역이라 정의할 수 있으며, 일반적으로 도시화 과정에서 형성되는 불투수면은 주로 도로(Drive way), 인도(Sidewalk), 주차장(Parking lot), 건물의 지붕(Roof) 등의 형태로 나타난다. 불투수면의 증가는 유출계수를 증가시켜 강수의 침투량 및 지하수 수위를 감소시킨다. 이로 인해 홍수기에 직접 유출량과 홍수피해를 증가시키고, 갈수기에는 하천의 건천화를 유발하여 수생태계를 악화시킨다. 미국 환경부에서는 불투수면을 저감하기 위한 주요정책으로 LID(Low Impact Development) 또는 GI(Green Infrastructure)의 도입을 제시하고 있다. 본 연구에서는 도시 유역의 강우-유출 및 수질 해석을 위해 SWMM모형을 구축하고, 도시 유역의 대표적인 토지이용 유형에서 불투수면 영향 저감을 위한 다양한 LID 기법을 적용하고 그 효과를 평가하였다. 모형의 보정기간은 2009년 7월 17일, 검정기간은 2009년 8월 11일이며, 강우유출발생시 측정한 실측 데이터를 사용하여 검 보정을 하였다. 아파트, 학교, 도로, 공원 등으로 구성된 복합용지에 투수성 포장(Pervious cover)과 옥상녹화(Green roof)기법을 단계별로 적용하고 유출량 및 오염부하 저감에 미치는 영향을 모의한 결과, 유역 내 불투수면이 투수면으로 전환되는 비율이 증가함에 따라 강우시 발생하는 유출량과 오염물질 부하량의 저감 효과가 큰 것으로 나타났다. 특히, 건물 옥상 녹화 및 주차장과 도로에 투수성 포장을 적용한 경우, 총 유출량은 15~61 %의 저감효과를 보였으며, 오염부하량에 대해서는 TSS 22~72 %, BOD 23~71 %, COD 22~71 %, TN 15~79 %, TP 9~64 %의 저감효율을 나타냈다.

금강본류의 건강성 평가를 위한 어류생태 및 수질 특성분석 (Analysis of Fish Ecology and Water Quality for Health Assessments of Geum - River Watershed)

  • 박윤정;이상재;안광국
    • 한국환경생태학회지
    • /
    • 제33권2호
    • /
    • pp.187-201
    • /
    • 2019
  • 본 연구에서는 2008년 6월과 2009년 5월 조사기간 동안 금강의 상 중 하류부의 14개 지점을 선정해서 이 화학적 수질의 특성을 파악하였으며 어류군집의 분포 및 길드 분석과 어류생물통합지수(Fish Assessment Index, FAI)의 다변수 8개 메트릭을 이용해 금강 수계의 건강도를 평가하였다. 수질 변수 평균 변화를 분석해 본 결과 중상류지점은 수질변수의 변이양상이 크게 없었고 갑천과 미호천이 합류되는 지점부터 유기물질이 축적되어 수질 변수가 급격한 변이양상을 보였다. 이 화학적 수질 특성을 분석한 결과, 미호천과 갑천이 합류되는 하류지점부터 BOD, COD, TN, TP, Cond, Chl-a는 증가하는 경향을 보였고 DO는 감소하여 부영양화와 녹조현상이 진행되고 있는 것으로 사료된다. 어류 군집 분석 결과, 종 풍부도지수와 종 다양도 지수는 중상류지점에서는 증가한 양상을 보인 반면 하류구간에서는 감소하는 양상을 보여 상류는 생태적 안정성은 양호하고 하류는 생태적으로 비교적 불안정한 것으로 보였다. 어류종 분포 분석결과 우점종은 피라미(Zacco platypus)이며 전체 어종의 20.9%를 차지하였고 아우점종은 참갈겨니(Zacco koreanus)가 13.1%를 차지했다. 어류 내성도 및 섭식길드 특성 분석에 따르면, 중상류지점에는 민감종, 충식성 그리고 여울성 어종이 우점한 반면 미호천이 유입되면서 하수종말처리장 오염원으로 영향을 받는 하류구간부터 내성종, 잡식성 그리고 정수성 어종 우점에 결정적인 영향을 준 것으로 나타났다. 따라서 우리는 수질 상태를 개선하기 위해 특히 도심 오염원의 부하량을 줄이도록 노력해야 하며 수생태계 보존과 복원에 관심이 필요한 것으로 요구된다.