• 제목/요약/키워드: COD loading rate

검색결과 222건 처리시간 0.023초

반응조 형태 및 슬러지층 유동화 특성에 따른 Upflow Anaerobic Sludge Blanket (UASB) 반응조의 운전효율 (Performance of Upflow Anaerobic Sludge Blanket (UASB) Reactor Depending on Reactor Configuration and Sludge Bed Fluidization)

  • 정병곤
    • 한국환경보건학회지
    • /
    • 제32권2호
    • /
    • pp.179-185
    • /
    • 2006
  • Effect of organic loading rate on UASB performance was evaluated under the renditions of some surface area/reactor volume ratio and different reactor diameter. At the low leading rate of 0.4 kg $COD/m^3{\cdot}d$, reactor performance was not affected by reactor diameter. At the organic loading rate of 6 kg $COD/m^3{\cdot}d$, however, volatile acid accumulation and low COD removal efficiency is observed in reactor having 6.4 cm diameter, while volatile acid is not accumulated at all and high COD removal efficiency is observed in reactor having 3 cm diameter. Such a difference of reactor performance depending on reactor diameter can be explained that sludge bed can be fluidized by evolved gas bubble in narrow reactor, while sludge bed ran not be fluidized by evolved gas bubble only in wide reactor. At a high organic loading rate of 20 kg $COD/m^3{\cdot}d$, it can be judged that there is no relation between reactor configuration and reactor performance because all reactors showed very low COD removal efficiencies regardless of reactor diameter. Narrow and tall type reactor is favorable condition for making sludge bed fluidization at a constant surface area/reactor volume ratio. Thus, it can be judged that reactor configuration and sludge bed fluidization have great influence to reactor performance.

음폐수 부하량에 따른 고온호기성 공정의 처리 양상 (Influence of Food Wastewater Loading Rate on the Reactor Performance and Stability in the Thermophilic Aerobic Process)

  • 장현민;최석순;하정협;박종문
    • 공업화학
    • /
    • 제24권3호
    • /
    • pp.279-284
    • /
    • 2013
  • 본 연구에서는 음식물류 폐기물 자원화 과정에서 생성되는 고농도 음폐수(food wastewater : FWW)를 대상으로 기존의 혐기성 공정의 대안책으로써 고온호기성 소화공정에 대한 성능을 검증하였고 공정 인자를 도출하였다. 이를 위해 수리학적 체류시간(Hydraulic retention time, HRT) 변화 및 유기물 부하량(Organic loading rate, OLR)에 따른 유기물 제거 효율과 안정성을 관찰하였다. 실험 결과 비교적 짧은 HRT를 가진 R1 (HRT : 5일)의 경우 OLR이 증가할 때, 급격한 pH감소가 일어나 심한 공정 저해를 받는 것으로 관찰되었다. 반면 R2 (HRT : 10일)의 경우에는 상대적으로 안정적인 공정 운전 및 효율적인 COD, 유기산 및 lipid 제거가 일어났다. 이는 상대적으로 긴 HRT로 인한 유기산 축적과 같은 공정저해 요인이 해결되어 상대적으로 높은 유기물 처리효율을 나타낸 것으로 생각된다. R1에서는 COD 부하량이 $18.6kgCOD/m^3d$에서 $28.4kgCOD/m^3d$으로 증가함에 따라 급격한 COD 제거율 감소를 보였다. 반면 R2에서는 각 OLR별로 3.61, 7.05, 9.43 그리고 $12.2kgCOD/m^3d$의 높은 COD 제거율을 보였다. 따라서 본 연구에서는 10일 이상의 HRT에서 고온 호기성 소화가 고농도 음폐수 처리에 탁월한 유기물 제거율을 나타냄을 알 수 있었다.

활성오니법에 의한 판지폐수중의 COD 제거에 관한 연구 (A Study on the COD Removal in the Paste-board Wastewater by Activated Sludge Process)

  • 도갑수;김영운
    • 기술사
    • /
    • 제18권3호
    • /
    • pp.28-35
    • /
    • 1985
  • As the paper industry consumes much water in process and discharge wastewater containing suspended solid and COD(chemical oxygen demand), relevant law against this discharge has been set up to limit the total containment of COD in discharge. This study has been carried out to improve the treatment method for the soluble COD in wastewater produced during the process of paste-board production, which is made of semichemical pulp and waste paper. Applicated methods are, O$_2$AS : O$_2$ activated sludge process DAS : Deep well activated sludge process SAS : standard activated sludge process and proper combination of DAS and SAS 1) As a result of this experiment, we get the following conclusion between in COD sludge loading "X" and COD removable rate in the process of treating waste-water. COD removable rate(%)=(0.778+0.0146/X)${\times}$100(%)……(7) 2) In case that the COD sludge loading is high, it has been cleared out that the COD removable rate shall become low due to unknown unsoluble substances contained in the process. Meanwhile, to increase the efficiency rate of treatment, it is thought to be necessary, to provide long-time contacts with activated sludge. 3) Once the COD of original waste-water and the target COD of treated water are decided, COD sludge loading is obtained from equation(7), and capacity of aeration tank in the effective systems such as O$_2$AS, DAS, to bet the required COD removable rate can be decided. Therefore the choice among SAS, O$_2$AS, DAS methods is made in consideration of required COD removable rate and allowable installation area. 4) In the sedimentation tank with sludge bulking, it is possible to increase the COD removable rate by 3~7% but still there exist many obstacles to manage this operation.

  • PDF

무산소-RBC 공정을 이용한 질소제거 특성 및 동력학적 인자 도출 (Characteristics and Biological Kinetics of Nitrogen Removal in Wastewater using Anoxic-RBC Process)

  • 최명섭;손인식
    • 한국환경과학회지
    • /
    • 제12권10호
    • /
    • pp.1085-1093
    • /
    • 2003
  • This study was conducted to investigate anoxic-RBC (rotating biological contactor) and its application in advanced municipal wastewater treatment process to remove biologically organics and ammonia nitrogen. Effluent COD and nitrogen concentration increased as the increase of volumetric loading rate. But, the concentration changes of NO$_2$$\^$-/ -N and NO$_3$$\^$-/ -N were little, as compared to COD and NH$_4$$\^$+/ -N. When the volumetric loading rate increased, COD removal efficiency and nitrification appeared very high as 96.7∼98.8% and 92.5∼98.8%, respectively. However, denitrification rate decreased to 76.2∼88.0%. These results showed that the change of volumetric loading rate affected to the denitrification rate more than COD removal efficiency or nitrification rate. The surface loading rates applied to RBC were 0.13~6.0lg COD/㎡-day and 0.312∼1.677g NH$_4$$\^$+/-N㎡-day and they were increased as the increase of volumetric loading rate. However, the nitrification rate showed higher than 90%. The thickness of the biofilm in RBC was 0.130 ∼0.141mm and the density of biofilm was 79.62∼83.78mg/㎤. They were increased as surface loading rate increased. From batch kinetic tests, the k$\_$maxH/ and k$\_$maxN/ were obtained as 1.586 g C/g VSS-day, and 0.276 g N/g VSS-day, respectively. Kinetic constants of denitrifer in anoxic reactor, Y, k$\_$e/, K$\_$s/, and k were 0.678 mg VSS/mg N, 0.0032 day$\^$-1/, 29.0 mg N/l , and 0.108 day$\^$-l/, respectively. P and K$\_$s/, values of nitrification and organics removal in RBC were 0.556 g N/㎡-day and 18.71 g COD/㎡-day, respectively.

산업폐수처리를 위한 호기성 생물막 유동층 반응기의 연구(II) -유기물 충격 부하가 미생물 성장에 미치는 영향- (A Study on an Aerobic Fluidized-Bed Biofilm Reactor for Treating Industrial Wastewaters(II) -Effect of Organic Shock Loading Rate on Biomass Characteristics-)

  • 안갑환;박영식;최윤찬;김동석;송승구
    • 한국환경과학회지
    • /
    • 제2권4호
    • /
    • pp.325-330
    • /
    • 1993
  • A number of experiments were conducted in order to investigate the organic removal efficiency and biomass characteristics according to the organic shock loading rate in a fluidized bed biofilm reactor. At the operation conditions of HRT, 8.44 hour, superficial upflow velocity, 0.9 cm/sec and temperature, 22$\pm$$1^{\circ}C$, the removal efficiency of SCOD was founded to be 96.5, 92 and 90 % with the organic shock loading rate of 3.5, 10.8 and 33 kgCOD/m$^3$ㆍday, respectively. Within the F/M ratio ranged 0.4 to 2.0 kgCOD/kgVSSㆍday, the SCOD removal efficiency was shown as 90% at F/M ratio of 2.0 kgCOD/kgVSSㆍday, but the TCOD removal efficiency was 72 % at F/M ratio of 1.8 kgCOD/kgVSSㆍday. The average biomass concentrations were 7800, 14950 and 27532 mg/l on the organic shock loading rate of 3.5, 10.8 and 33 kgCOD/$\textrm{m}^3$ㆍday, respectively. This result was agreed with the fact that more biomass could be produced at high concentration of substrate, but some biomass was detached at the onset of shock and easily acclimated at the shock condition.

  • PDF

어류 폐기물의 혐기성소화 처리(I): 반응조 형상 및 슬러지층 유동화가 소화조 Start-up에 미치는 영향 (Anaerobic Digestion Fish Offal(I): Effect of Reactor Configuration and Sludge Bed Fluidization on Start-up of Digester)

  • 정병곤;김병효
    • 한국해양환경ㆍ에너지학회지
    • /
    • 제9권2호
    • /
    • pp.72-78
    • /
    • 2006
  • 혐기성 소화조의 단면적/용량 비를 일정하게 한 상태에서 반응조 직경만을 달리한 반응조에 유기물 부하율에 따른 소화조 운전효율을 평가하였다. $0.4\;kg\;COD/m^3{\cdot}d$의 낮은 유기물 부하율에서는 반응조 직경에 관계없이 높은 처리 효율을 나타내어 반응조 형상에 따른 처리효율 차이는 없었다. $6\;kg\;COD/m^3{\cdot}d$의 유기물 부하율에서는 반응조 직경에 따라 전혀 다른 처리효율이 관측되었다. 즉, 직경 6.4 cm 반응조에서는 휘발성산의 축적과 낮은 COD 제거효율이 관측되었으나 직경 3 cm 반응조에서는 높은 COD 제거효율이 관측되었고 휘발성산의 축적도 일어나지 않았다. 이러한 차이가 나타나게 된 이유는 직경이 작은 반응조의 경우에는 생성된 가스의 부상에 의해 슬러지층의 유동화가 원활하게 일어난데 반해 직경이 큰 반응조의 경우에는 그렇지 못한 것이라고 판단된다. $20\;kg\;COD/m^3{\cdot}d$의 높은 유기물 부하율에서는 반응조 직경과는 관계없이 극히 낮은 처리효율을 나타내어 높은 유기물 부하에서는 반응조 형상과 처리효율과는 관계가 없는 것으로 나타났다. 따라서 혐기성 소화조의 효율적인 start-up은 슬러지층의 유동화가 중요한 인자이며 동일 단면적/용량 비에서 반응조 직경이 작을수록 유리한 것으로 나타나 반응조 형상도 반응조 운전효율에 큰 영향을 미치는 것으로 나타났다.

  • PDF

호기성 고정생물막반응기에서 동일 질량부하의 수리학적 및 농도충격부하시 반응의 비교 (Comparison of Aerobic Fixed-film Process Response to Quantitative and Hydraulic Shock for the Same Increases in Mass Loading)

  • 안미경;이규훈;박태주
    • 한국환경과학회지
    • /
    • 제3권3호
    • /
    • pp.285-296
    • /
    • 1994
  • The objective of this study was to examine and compare to transient response to quantitative and hydraulic shocks which produce equal changes in mass rate of organic feed in aerobic fixed-film process. The general experimental approach was to operate the system at several growth rates under steady-state(pre-shock) conditions, then to apply step changes during day 3 in dilution rate(hydraulic shock) , or feed concentration(Quantitative shock) at the same organic mass loading rate. Performance was assessed in both the transient state and the new steady-state (post- shock). Shock load of different type did not produced equivalent disruptions of effluent quality for equal increases in mass loading rate. Based on effluent concentrations, a hydraulic and a Quantitative shock at the same mass loading caused equal increase in total effluent COD, but the increase was primarily a result of suspended solids the hydraulic shock and COD in the quantitative shock. The time which effluent COD came to peak values were about 32~48 hours at the low organic loads and 52 ~ 72 hours at the high organic loads, respectively A quantitative shock produced a much greater increase in effluent COD than did a hydraulic shock at the same mass loading. Mean and peak values of effluent concentration weve increased in 2.8~4.2 times at low organic loading rate, 5.2~6.6 times at the high organic loading rate, respectively. Key words : Aerobic fixed-film reactor, Quantitative shock, hydraulic shock, mass loading rate.

  • PDF

고정화 공생 Bacteria를 이용한 호발폐수 중 PVA분해 신공정 개발 (Development of a New Process for PVA Degradation in Desize Wastewater by lmmobilized Symbiotic Bacteria)

  • 김정목;조무환조윤래정선용
    • KSBB Journal
    • /
    • 제6권4호
    • /
    • pp.395-402
    • /
    • 1991
  • A new process was developed to degrade PVA(polyvinyl alcohol) in desize wastewater. Two symbiotic bacteria of Pseudomonas strain G5Y and PW were immobilized on the media by adsorption. A natural zeolite was chosen as the best media considering cell adhesion capacity, sedimentation rate, and material cost. PVA and COD removal efficiencies of this system for synthetic wastewater were 84% and 85% at the retention time of 6 hr, when the volumetric loading rate was PVA 8g/L·day and COD 8g/L·day, and cell density was 19,775 mg/L. In case of desire wastewater, they were 78% and 72% at the retention time of 6 hr, respectively, when the volumetric loading rate was PVA 8g/L·day and COD 13.2g/L·day, and cell density was 32,899mg/L. In case of desize wastewater, PVA and COD removal efficiencies were lower than synthetic wastewater, but cell density of the desize wastewater was lower than that of the synthetic wastewater, because there were insufficiency of necessary nutrition and variety of desize materials in the desize wastewater. A pilot test was successfully performed showing 88% and 82%, PVA and COD removal efficiencies at the retention time of 24 hr, when volumetric loading rate were 4.7 PVA g/L·day and COD 6.9g/L·day, and cell density was 12,,324 mg/L.

  • PDF

혐기성 생물막법에 의한 유기성 배수의 처리 (Treatment of Organic Wastewater by the Anaerobic Fixed-Film Process)

  • 김용대;정경훈
    • 한국환경보건학회지
    • /
    • 제17권2호
    • /
    • pp.41-47
    • /
    • 1991
  • A study on the effects of volumetric loading rate, surface loading rate and hydraulic. retention time (HRT) for the anaerobic treatment was conducted with the anaerobic fixed-film process using synthetic wastewater at lower temperature than that of conventional anaerobic treatment. The results are as follows 1. Alkalinity and pH value decreased as the hydraulic retention time increased 2. Increase of the volumetric lodaing rate led to increasl of effluent COD concentration and decrease of COD removal efficiency. 3. The removed volumetric loading rate increased linearly according to the increase of the volumrtric loading rate. 4. Similarly, the linear increase of the removed surface loading rate was noticed with an increase of the surface loading rate.

  • PDF

고정 생물막공법에서 부착미생물의 역세에 관한 연구 (A Study of Attached Biomass Back Washing in Fixed Film System)

  • 이창근;김정숙
    • 한국환경과학회지
    • /
    • 제6권3호
    • /
    • pp.219-224
    • /
    • 1997
  • The cloging phenomenon in the fixed film reactor Is shown when biomass growth Is excessive for long operating time. In addition, effluent water Quality gets worse because of detachment of biomass. In this study, we conducted air-backwashing to sustain biomass In reactor to complement these defects. The results of experimental are showed In the following conclusion. The detachment rate was 19.5 - 38.0% when the organic loading rate was 0.40 - 1.32 kg COD/$m^3$/day, the k - backwashing Intensity was 2 L/min(6.7 $m^3$/$m^2$/hrl and the backwashing time was 15 - 19 seconds. And the detachment rate was 32.2 - 58.6 % when the organic loading rate was 1.37 - 2.27 kg COD/$m^2$/day, the backwashing time was 1 - 12 minutes. As orgnic loading rate and backwashing time ale Increased, detachment of fixed biomass Is Increased. The detachment equation with detachment rate(DR, %), backwashing time(BWT, min), fixed biomass concentration(FB. mg/L), and organic leading rate(OLR, kg COD/ms/day) through multiple linear regession was given by the following equation: DR : 17.964 $BWT^{0.1407} FB^{0.0597} OLR^{0.1946}$

  • PDF