• Title/Summary/Keyword: COD Removal

Search Result 1,132, Processing Time 0.101 seconds

A Study on the Quality Improvement of Raw-Water Using Submerged Biofilter (생물막공정에 의한 상수원수의 수질개선에 관한 연구)

  • Lee, Soo-sik;Ahn, Seung-seop
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.13 no.1
    • /
    • pp.81-94
    • /
    • 1999
  • This study aims at a proposal of the plan that can improve raw water quality by an experimental study using influent water of Nak-dong river, which has been used as raw water for drinking in U-city, through the establishment of the submerged biofilter process PILOT PLANT of media packing channel method. From the analysis of removal efficiency for each water quality item of the collected sample, following results are obtained. First of all, the removal rate of suspended material, BOD, COD, T-N, TOC, turbidity, and $NH_3$ -N appear 82%, 78%, 42%, 15%, 57%, 43%, 54%, and 55% respectively and it is known that the submerged biofilter process of media packing channel method takes effects on water quality improvement from the above analysis results of water treatment efficiency. And the analyzed results for water temperature, residence time, and activities of microorganism, which can be the factors affect on water quality improvement, are as follows. 1) The removal rate variation of SS, BOD, and COD attendant on water temperature change is examined and it is known that the removal rate increases at $13^{\circ}C$ or above. 2) The removal rate of SS, BOD, and COD attendant on residence time is most active in the range of 0~18hr, 0~1.8hr, 0~2.7hr respectively, so it is found that the removal rate becomes smaller after 2.7hr. 3) From the examination of microorganism activity with the abundance of normal bacteria, it is found that the floating bacteria decrease as the flow distance from raw water inflow point of PILOT PLANT increases, and the adhesive bacteria have no concern with the flow distance. And it its known that the biomass of fine algae decreases as the flow distance from the raw water inflow point of PILOT PLANT increases from the examination with Chl-a.

  • PDF

The Investigation of Treatment of Pistachio Processing Industrial Wastewater by Electrochemical Methods in Terms of Chemical Oxygen Demand and Total Phenol Removal

  • Alper Erdem Yilmaz;Baybars Ali Fil;Murat Tolga Yilmaz;Serkan Bayar;Zuhal Koksal
    • Journal of Electrochemical Science and Technology
    • /
    • v.15 no.1
    • /
    • pp.178-189
    • /
    • 2024
  • This work aims to investigate the efficiency of electrocoagulation (EC) of pistachio processing industrial wastewater (PPIW) using the continuous EC process. The tubular reactor made of stainless steel with an internal diameter of 60 mm was used as a cathode electrode. The effect of some parameters was examined on the removal of chemical oxygen demand (COD) and total phenols (TP) removal efficiency. The influences of the initial pH of wastewater (from 4 to 8), flow rate (from 25 to 125 mL/min), current density (from 7 to 21 mA/cm2), and supporting electrolyte type (NaCl, NaNO3, and Na2SO4), supporting electrolyte concentration (from 10 to 100 mg/L NaCl) on removal efficiency were investigated to determine the best experimental conditions. The examination of the physico-chemical parameters during the EC treatment showed that the best removal efficiency was obtained under conditions where the flow rate was 25 mL/min (20 min reaction time), the pH value was 5.2, and the current density was 21 mA/cm2 has set. Under these experimental conditions, COD and TP removal efficiency were found to be 75% and 97%, respectively, while energy consumption was 18.5 kW h/m3. The study results show that the EC can be applied to PPIW pre-treatment.

A study on treatment farm.fishing village wastewater using aquatic plants (수생식물을 이용한 농어촌하수 처리에 관한 연구)

  • 박진식;문추연;장성호
    • Journal of environmental and Sanitary engineering
    • /
    • v.17 no.2
    • /
    • pp.40-47
    • /
    • 2002
  • In this study, water hyacinth plants(Eichhornia crassipes), water parsley(Oenanthe javanica) and Lemna paucicostate were used to treat contaminants such as COD, T-N and T-P in far m·fishing village wastewater. The results were as follows : In the batch system experiment, water hyacinth was showed at the high removal efficiency in the 173∼412kgCOD/ha·day concentration that is rather than 260mg/1 of the high concentration. The next is Oenanthe javanica, Lemna. Oenanthe javanica was showed the high removal efficiency in the 96∼173kgCOD/ha·day concentration that is less than 260mg/1 of the low concentration.

A Study on the Treatment of Dyeing Wastewater Using the Supernatant after Treatment of Acidic Metal Wastewater (중금속 산폐수 처리 후의 상등액을 이용한 염색폐수처리 연구)

  • 신진명;박장진;김미자;주소영
    • Journal of environmental and Sanitary engineering
    • /
    • v.18 no.1
    • /
    • pp.41-50
    • /
    • 2003
  • Traditionally the supernatant after chemical treatment of metal acid wastewater is discharged in environment. The supernatant can be used as a coagulant as it contains effective metals. The aim of this study is to investigate the feasibility of treatment of dyeing wastewater using the supernatant after treatment by magnesium hydroxide and dolomite($Ca{\cdot}Mg(CO_3)_2$), of acidic metal wastewater. In dyeing wastewater treatment with the supernatant, optimum pH and dosage were determined. COD, turbidity and color were analyzed to evaluate the performance of treatment. In the case of magnesium hydroxide, the optimum dosage was 10%(v/v) for supernatant A and 3%(v/v) for supernatant B. Color, turbidity and COD removal was 99~100%, 85~97% and 43~53%, respectively. In the case of dolomite, the optimum dosage was 10%(v/v) for supernatant A and 3% for supernatant B. Color, turbidity and COD removal was 96~99%, 62~9l% and 52~53%, respectively.

Treatment of Starch Wastewater by Anaerobic Digestion Combined with Hollow Fiber UF

  • No, Seong-Hui;Na, Jae-Un;Kim, Seon-Il
    • 한국생물공학회:학술대회논문집
    • /
    • 2000.11a
    • /
    • pp.745-748
    • /
    • 2000
  • Anaerobic digester coupled with hollow fiber membrane unit. Treatment of starch waste with anaerobic digester-membrane system was studied. $0.17\;m^2$ area of hollow fiber membrane unit of known pore size was immersed into laboratory-scale anaerobic digestion system. The gas production was about $0.74\;m^3/kg$ COD treated. The COD removal efficient was about 80-95% depending on the hydraulic retention time. Crossflow ultrafiltration as Post treatment to anaerobic filter. The study conducted with different membrane pore size indicated that membrane with 1,000,000 molecular weight cut-off size gave a higher COD removal efficiency in the range of 83-87% while giving a study flux of $120-130\;L/m^2\;{\cdot}\;h$. A study was conducted to see the long term clogging effect of membrane also.

  • PDF

An Electrolytic Treatment of Shipboard Sewage by Using DSA Electrode(II) -Continuous Electrolytic Treatment- (DSA 전극에 의한 선박오폐수의 전해처리(II))

  • 김인수;조권희;남청도
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.3 no.2
    • /
    • pp.77-84
    • /
    • 1997
  • For the effective treatment of shipboard sewage continuously, a non-diaphragm electrolytic treatment device using DSA type insoluble electrode, Ti/IrO2, anode and H-C metal cathode, was studied. The most effective electrolytic conditions were obtained when cell clearance, 6mm, pH 5-6 and the concentration of seawater, more than 20% as batch test results. The COD removal rate was varied in logarithmic function, showed as C=Coe-KE and the required current was E = A/QCo [A.min/mgCOD]. When the COD removal effeciency was more than 90%, the electrolytic reaction constant was 0.02.

  • PDF

Optimum Pre-treatment Method in Constructed Wetlands by Natural Purification Method for Treating Livestock Wastewater (자연정화공법에 의한 인공습지에서 효과적인 축산폐수처리를 위한 최적 전처리방법 구명)

  • Park, Jong-Hwan;Seo, Dong-Cheol;Kim, Ah-Reum;Kim, Sung-Hun;Lee, Seong-Tea;Jeong, Tae-Uk;Choi, Jeong-Ho;Lee, Sang-Won;Cho, Ju-Sik;Kim, Hyun-Ook;Heo, Jong-Soo
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.44 no.3
    • /
    • pp.425-433
    • /
    • 2011
  • In order to obtain optimum pre-treatment methods and improve T-N and T-P removal efficiencies, removal rates of pollutants in small-scale livestock wastewater treatment apparatus with water plant filtration bed or activated sludge tank were investigated. Based on the results from the optimum pre-treatment in small-scale livestock wastewater treatment apparatus, removal efficiencies of pollutants in livestock wastewater treatment plant with water plant filtration and activated sludge beds. The removal rates of COD, SS, T-N, and T-P in effluent were 83, 89, 63 and 87% in small-scale livestock wastewater treatment apparatus with water plant filtration bed, respectively. The removal rates of COD, SS, T-N, and T-P in effluent were 96, 95, 86 and 92% in small-scale livestock wastewater treatment apparatus with activated sludge tank, respectively. For increasing the COD, SS, T-N, and T-P removals in small-scale livestock wastewater treatment apparatus, the water plant filtration and activated sludge beds are recommended. In livestock wastewater treatment plant with water plant filtration ($1^{st}$ treatment) and activated sludge ($2^{nd}$ treatment) beds, the concentrations of COD, SS, T-N, and T-P in effluent were 39, 15, 42 and $1mg\;L^{-1}$, respectively. It was shown that the concentrations of COD, SS, T-N, and T-P met acceptable effluent quality standard for livestock wastewater. Based on the above results, the removal rates of COD, SS, T-N, and T-P in effluent were over 99.8, 99.9, 99.2, and 99.9% in livestock wastewater treatment plant, respectively.

A Study on Coagulation and Ozone Treatment of Nonbiodegradable Substances in Landfill Leachate (생물학적 난분해성물질을 함유한 매립장 침출수의 응집 및 오존처리에 관한 연구)

  • Kim, Jong Shik;Choi, Joon Ho
    • Applied Chemistry for Engineering
    • /
    • v.9 no.3
    • /
    • pp.330-335
    • /
    • 1998
  • The objectives of this study are summarized with two. The one is to remove of $COD_{Cr}$, color and turbidity with coagulation and ozonation in nonbiodegradable landfill leachate, the other is to compare of water qualities with pre-ozonation and post-ozonation. The results are summarized as follows ; 1) 90 minutes ozonation with $75mgO_3/min$($4.5gO_3/hr$) was conducted at pH 4,7, 10 to remove $COD_{Cr}$. Removal efficiencies were investigated with 48.2%, 52.6%, and 62.3% respectively. As increasing pH, $COD_{Cr}$ removal efficiencies were increased, it was considered that hydroxyl radical($OH{\cdot}$) which strongly oxdize and nonselectively react with organic compounds, was rapidly produced by ozone self-decomposition at high pH. 2) Alum, ferric chloride and ferrous sulfate were used for coagulation as inorganic coagulant. Ferric chloride was investigated with optimal coagulant, and it removed $COD_{Cr}$ about 12.0% at pH5 and dosage of $2,000m{\ell}/{\ell}$. Cation(C-101P), anion(A-601P) and nonion(SC-050) were tested to remove organic pollutants in landfill leachate. Cation(C-101P) was investigated with the most effective organic coagulant, and removal efficiency of $COD_{Cr}$ was 19.8% at pH5 and dosage of $100m{\ell}/{\ell}$. 3) Color and turbidity were removed up to 88.6%, 97.0% at pH10, when contacted 90 minutes with ozone, respectively. These removal efficiencies were much higher than those of $COD_{Cr}$ and $COD_{Mn}$. It was considered that ozone could oxdize the triggering materials of color and turbidity selectively and preferentially. 4) $COD_{Cr}$, color and turbidity were more effectively removed with pre-ozonation than post-ozonation about 8%, 3.5% and 1% respectively. These results were well corresponed with other's studies that pre-ozonation will increase the effect of coagulation.

  • PDF

A Study on the Removal of Grease and Oill in the Treatment Plant (하수처리장의 유지제거에 대한 연구)

  • 박재효
    • Journal of Environmental Health Sciences
    • /
    • v.7 no.1
    • /
    • pp.1-7
    • /
    • 1981
  • During 20 days from November 4 to 28, 1980, the quantities of grease and oil, BOD (biological oxygen demand), COD (chemical oxygen demand), SS (suspended solid) were measured at Grit Chamber, Primary Sedimentation Tank, Secondary Sedimentation Tank in Chung Gye Chun sewage treatment plant. The results were as follows. 1. The average of grease and oil quantities were 251mg/l at Grit Chamber, 185mg/l at Primary Sedimentation Tank, 47mg/l at Secondary Sedimentation Tank. 2. In the secondary treatment for the removal of grease and oil, the removed quantities of grease and oil were increased according to increasing the quantities of influent grease and oil. The regression equation were as follows G.O.removed=0.731 G.O. influent+3.235 (r=0.887) 3. The average of grease and oil removal rate was 76.4% and the standard deviation of grease and oil removal rate daily was 10.6%. 4. G.O. (grease and oil) and BOD, COD, SS showed significant correlationship at Grit Chamber, Primary Sedimentation Tank, Secondary Sedimentation Tank. (P<0.05). 5. In the secondary treatment, effluent grease & oil and other parameters were analyzed by means of Stepwise multiple regression. Multple regression equation for estimates of effluent grease and oil were as follows. $GO_E=-9.1637+2.0380 SS_E+0.068 SS_I$ (r=0.778) 6. The correlative parameters for the effluent grease and oil seem to be the influent SS and the effluent SS. 7. It was estimated that the removal of grease and oil would be improved by means of improvement of suspended solids removal efficiency but it is necessary to inquire further into the study.

  • PDF

The Effect of HRT and SRT on Treatment Efficiency of Activated Sludge Process for Low Concentration Municipal Sewage (저농도 도시하수 처리를 위한 활성슬러지공정에서 HRT 및 SRT가 처리효율에 미치는 영향)

  • Whang, Gye Dae;Kim, Min Ho;Ko, Sae Bom
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.11 no.1
    • /
    • pp.64-73
    • /
    • 1997
  • Most of the municipal wastewater treatment plants operated in Korea are designed for high concentrations municipal sewage. However, activated sludge process employed by municipal wastewater treatment plant is operated at low organic loading. The objective of this study was to determine optimum operating condition of activated sludge process for treatment of low concentration municipal sewage. Three bench scale activated sludge reactors were operated to investigate the effect of HRT and SRT on the COD and TSS removal efficiency. The average concentration of TSS, SCOD, SBOD and TKN in influent were 118mg/l, 61mg/l, 21mg/l, and 12mg/l, respectively. The activated sludge reactors operated with various HRT and SRT showed about 89-93% TSS removal efficiency. HRT and SRT does not affect the TSS removal efficiency of actvatied sludge process significantly. However, HRT affected the SCOD removal efficiency slightly. As the HRT decreases from 13hours to 3hours, the SCOD removal efficiency decreases from 67% to 56%. The average effluent TCOD concentration of the reactor operated with 3hours of HRT was approximatly 40-45mg/l. Kinetic coefficient yield (Yt) and decay coefficients(Kd) were 0.594-0.954 mgMLVSS/mgCOD and $0.0197-0.0317day^{-1}$, respectively. Low concentration municipal sewage can be treated with 3 hours of HRT without effluent quality deterioration and SRT does not affect the substrate removal efficiency at this operation condition.

  • PDF