Study on the Activation of Microbial Products by Using the Leachate (침출수를 이용한 미생물 제제의 활성에 관한 연구)

  • 이장훈;정준오;남명흔
    • Journal of Environmental Health Sciences
    • /
    • v.24 no.3
    • /
    • pp.70-76
    • /
    • 1998
  • Activation bacteria, identified from commercial microbial products, were applied to leachate treatment. Total seven strains of bacteria Enterobacteriaceae spp. (5), Bacillus sp. (1), Aeromonas sp. (1) were seeded in the leachate and cultured in the shaking incubator at 25$^{\circ}$C and 250 rpm. While cultured, they were sampled in given time intervals and the removal rates of SS, COD, BOD, T-N.and T-P were measured an indicators of leachate treatment. Through the screening test, four of 7 strains of bacteria were considered to be effective and they were named as "effective group". The capability of leachate treatment was observed on three different groups of bacteria single, effctive, and total mixed. The result showed that the removal rates of COD and SS for the total mixed group were 64 and 71% respectively. BOD removal rate was reached nearly 99% by seeding of effective griup and removal rates of T-P and T-N were 83 and 82% respectively. However seeding of single strain was less effective than that of any mixed group in leachate treatment.

  • PDF

A Study on Treatment of Livestock Wastewater by Sequencing Batch Reactor (연속회본식 반응조를 이용한 축산폐수의 처리에 관한 연구)

  • 박석환;정문식
    • Journal of Environmental Health Sciences
    • /
    • v.18 no.2
    • /
    • pp.62-66
    • /
    • 1992
  • This study was performed to investigate the characteristics of livestock wastewater excepting pig feces and the variation tendency of water quality and the removal efficiency of polluting materials by establishing the sequencing batch reactor in the field.The results were as follows, 1. The characteristics of livestock wastewater as follows: BOD: 619.80, COD$_{cr}$: 782.70, NH$_{3}$-N: 194.20, TKN: 232.81, PO$_{4}$-P: 24.10, T-P: 215.14 (mg/l) 2. During the reaction, negative correlation existed between pH and dissolved oxygen concentration. 3. The removal efficiency of the organic material by the index of BOD and COD was about 90%. 4. Nitrogen removal efficiency was 65.6% by total Kjeldahl nitrogen index, and phosphorous removal efficiency was about 47% by PO$_{4}$-P concentration.

  • PDF

Removal of Rhodamine B in Water by Ultraviolet Radiation Combined with Electrolysis(I) (전기분해와 UV 조사에 의한 수중의 Rhodamine B의 제거(I))

  • Park, Young-Seek
    • Journal of Environmental Health Sciences
    • /
    • v.34 no.6
    • /
    • pp.439-445
    • /
    • 2008
  • The feasibility study for the application of the removal and mineralization of Rhodamine B (RhB) was performed in a batch electrochemical reactor. The electro/UV process was consisted of DSA (dimensionally stable anode) electrode and UV-C or ozone lamp. The experimental results showed that RhB removal by the ozone lamp was higher than that of the UV-C lamp. Optimum current of the electro/UV process was 1 A. The electrochemical, UV and electro/UV process could completely degrade RhB, while a prolonged treatment was necessary to reach a high level RhB mineralization. It was observed that RhB removal in electro/UV process is similar to the sum of the UV and electrolytic decolorization. However, it was found that the COD of RhB could be degraded more efficiently by the electro/UV process (90.2 %) than the sum of the two individual oxidation processes [UV (19.7%) and electrolytic process (50.8%)]. A synergetic effect was demonstrated between the UV and electrolysis.

Pollutant Removal Efficiency in Oxidation Pond with Filamentous Algae Mat (사상성 조류매트 산화지의 수질정화효율)

  • Choi, Sun-Hwa;Jang, Jeong-Ryeol;Ahn, Yeul
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2005.10a
    • /
    • pp.655-660
    • /
    • 2005
  • This study was carried out to evaluate of water purification in oxidation pond with filamentous algae mat. It is the water treatment process in the small rural streams to remove the organic materials and nutrients. We used the filamentous algae mat(FAM) which selectively predominate the filamentous algae to prevent the additional contamination by algae outflow. The removal efficiencies of COD, SS, T-N and T-P in Oxidation Pond with Filamentous Algae Mat were -2.5%, 84.7%, 63.9% and 89.2%, respectively. The removal efficiencies of T-N and T-P which are nutrients index were high. Results of this study would help us to determine the possibility of using the water treatment on the contaminated small rural streams.

  • PDF

RESEARCH PAPERS : REMOVAL EFFICIENCY OF THE POLLUTANTS BY MULTILAYERED METAL TREATED CARBON FILTER

  • Oh, Won-Chun;Lee, Ho-Jin;Bae, Jang-Soon
    • Environmental Engineering Research
    • /
    • v.9 no.5
    • /
    • pp.193-200
    • /
    • 2004
  • A study of the treatment of piggery wastes using a multilayered metal-activated carbon system followed by carbon bed filtration was carried out at bench scale. From the physicochemical properties obtained from samples treated with aqueous solutions containing metallic ions such as Ag$^+$, Cu$^{2+}$, Na$^{-}$, K$^+$ and Mn$^{2+}$, main inspections are subjected to isothem shape, pore distribution with micropore, SEM and EDX. Multilayered metal-activated carbons were contacted to waste water to inwestigate the simultaneous catalytic effect for the COD, BOD, T-N and T-P removal. From these removal performance was achieved. The high efficiency of the multilayered metal-activated carbon bed, satisfactory removal performance was achieved. The high efficiency of the multilayered metal-activated carbon bed was derermined by the properties of this material for trapping, catalytic effect and adsorption of organic solid particles.

A feasibility of coagulation as post-treatment of the anaerobic fluidized bed reactor (AFBR) treating domestic wastewater (도시하수 처리 혐기성 유동상 반응조의 후속공정으로서 화학응집의 가능성 평가)

  • Yang, Seung Yong;Bae, Jae Ho
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.28 no.6
    • /
    • pp.623-634
    • /
    • 2014
  • This study examined a feasibility of coagulation as post-treatment to remove sulfide and phosphorus for the effluent of anaerobic fluidized bed reactor (AFBR) treating domestic wastewater. Removal efficiencies of sulfide, phosphorus and COD by coagulation were not affected by pH in the range of 5.9 to 7.2. Alkalinity requirement could be estimated by the amount of $Fe^{3+}$ to form $Fe(OH)_{3(S)}$ and to remove sulfide and phosphorus. At coagulant aid dosage of 2 mg/L, anionic polymer showed best results regarding size and settleability of flocs. Sulfide removal for the AFBR effluent at the $Fe^{3+}/S^{2-}$ ratio of 0.64, close to the theoretical value of 0.67 found with a synthetic wastewater, was only 75.2%. One of the reasons for this high $Fe^{3+}/S^{2-}$ ratio requirement is that the AFBR effluent contains sulfide, phosphorus, hydroxide and bicarbonate which can react with $Fe^{3+}$ competitively. Concentrations of sulfide and phosphorous reduced to below 0.1 and 0.5 mg/L, respectively, at the $Fe^{3+}/S^{2-}$ ratio of 2.0. Average effluent COD of 80 mg/L, mostly soluble COD, was obtained at the dosage 50 mg $Fe^{3+}/L$ ($Fe^{3+}/S^{2-}$ ratio of 2.0) with corresponding COD removal of 55%. For better removal of COD, soluble COD removal at the AFBR should be enhanced. Coagulation with $Fe^{3+}$ removed sulfide, phosphorus and COD simultaneously in the AFBR effluent, and thus could be an alternative process for the conventional wastewater treatment processes where relatively high quality effluent is not required.

Advanced Oxidation Process for the Treatment of Terephthalic Acid Wastewater using UV, H2O2 and O3 : Organic and Color Removal Studies (UV, H2O2, 오존을 이용한 고급산화공정에서의 테레프탈산 제조공정 폐수 처리 : 유기물 및 색도제거 연구)

  • Kwon, Tae-Ouk;Park, Bo-Bae;Moon, Il-Shik
    • Korean Chemical Engineering Research
    • /
    • v.45 no.6
    • /
    • pp.648-655
    • /
    • 2007
  • UV/H_2O_2$, $O_3$, $O_3/H_2O_2$, $UV/H_2O_2/O_3$ processes were tested for the removal of COD and color from terephthalic acid wastewater. COD removal efficiencies were 10, 48, 56, 63% in the $UV/H_2O_2$, $O_3$, $O_3/H_2O_2$, $UV/H_2O_2/O_3$ process respectively. Color removal efficiency of $UV/H_2O_2$ process was 80% and $O_3$, $O_3/H_2O_2$, $UV/H_2O_2/O_3$ processes were almost more than 99%. Terephthalic acid, isophthalic acid and benzoic acid were completely destructed in terephthalic wastewater within 120 min by $UV/H_2O_2/O_3$ process and shows high COD and color removal efficiencies. The optimum concentration of $H_2O_2$ dosage was found to be 0.5 M, 25 mM and 5 mM for $UV/H_2O_2$, $O_3/H_2O_2$ and $UV/H_2O_2/O_3$ processes respectively, Organic destruction efficiency was enhanced and also reducing the consumption of $H_2O_2$ dosage by combining UV, $H_2O_2$ and $O_3$ process.

A Comparative Study on COD Fractionation Methods of Wastewater (하수의 COD 분류 시험 방법에 관한 비교 연구)

  • Kim, Sung-Hong;Yun, Jung-Won;Choi, Young-Gyun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.24 no.4
    • /
    • pp.387-394
    • /
    • 2010
  • The influent COD of municipal wastewater has been divided into 4 fractions; readily soluble biodegradable, slowly particulate biodegradable, soluble and particulate unbiodegradable COD. The mathematical modeling of biological wastewater treatment processes and the design and operation of nutrient removal plants require a reliable and accurate estimate of the composition of influent wastewater COD. COD utilization rate is proportional to the oxygen uptake rate(OUR), so a batch biodegradation test with OUR measurement has been effectively used for the determination of COD fractionation. But the mathematical model of COD utilization and heterotrophs synthesis is essential to interpret the OUR measurement. Mamais method is another method for determining readily biodegradable soluble COD. Like the OUR test method, batch biodegradation test is necessary but it does not require mathematical model. These two methods for determining COD fractionation are introduced here in detail. Experimental results showed that COD composition by Mamais method is not different to that by OUR test method so, either of them can be used.

A Basic Study on the Anaerobic Wastewater Treatment using Nonwoven Fabric Filter Bioreactor (부직포 여과막 생물반응조의 혐기성 폐수처리에 관한 기초연구)

  • Kim, Taek-Su;Bae, Min-Su;Cho, Yun-Kyung;Cho, Kwang-Myeung
    • Journal of Korean Society on Water Environment
    • /
    • v.21 no.5
    • /
    • pp.464-469
    • /
    • 2005
  • In the nonwoven fabric filter bioreactor (NFBR), both the construction and the operation costs could be saved because a high concentration of microorganism can be maintained in the reactor as in the membrane bioreactor. However, the NFBR process has been investigated only under aerobic and/or anoxic conditions, In this research, a basic anaerobic treatment experiment was performed at $35^{\circ}C$ by feeding an airtight NFBR with a concentrated synthetic organic wastewater. The organic loading rate (OLR) of the NFBR was increased stepwise from $0.25kg\;COD/m^3-day$ to $0.77kg\;COD/m^3-day$ by gradually decreasing the hydraulic retention time from 20 days to 13 days. The results of the research showed that the best COD removal efficiency achieved at the OLR of $0.67kg\;COD/m^3-day$ with a value of 99.3%. The methane content of the produced gas was highest with a value of 61.2% at the OLR of $0.33g\;COD/m^3-day$. The highest methane production rate was $0.89g\;COD/m^3-day$ at the same OLR. The operation was terminated at the OLR of $0.77kg\;COD/m^3-day$ because of the deterioration in COD removal efficiency, gas production rate, and the methane content of the gas. Further researches are recommended for the NFBR to be employed for anaerobic treatment of organic wastewaters.

Design of a Water Reuse System Combined with a Fiber Filtration and Electrolysis (섬유여과기와 전기분해조를 병합한 물 재이용 시스템 설계)

  • Shin, Choon-Hwan
    • Journal of Environmental Science International
    • /
    • v.24 no.11
    • /
    • pp.1385-1391
    • /
    • 2015
  • A water reuse system was designed for a demonstration plant by combining fiber filtration and electrolysis. A discharged dye wastewater after treated with biomedia was used in this study. It was found that an additional removal of suspended solids (SS) was feasible with 2-stage filtration while electrolysis was not effective. Also, $COD_{cr}$ and $COD_{Mn}$ were not removed with 2 -stage filtration but electrolysis resulted in about 26.9% additional removal. This indicates that electrolysis play an important role in organic removal. Removal of T-N and T-P was negligible with 1 and 2-stage fiber filtration and low-level electrolyte. However, with 2000 ppm of electrolyte, their removal efficiencies were about 83.1 and 60%, respectively, suggesting that the removal rates are well associated with the electrolyte concentrations. With high-level electrolyte, colority was removed about 82% while chlorine ions were removed only about 10%. Therefore, to treat underground water containing high-level salinity in the follow-up study, based on the results in this paper, a combined system with selection of additional unit process and reverse osmosis will be designed.