• Title/Summary/Keyword: COD 오염부하량

Search Result 174, Processing Time 0.03 seconds

A Study on the Improvement of Treatment Efficiency for Nitrogen and Phosphorus by Improved Sewage Treatment Process in Constructed Wetland by Natural Purification Method (자연정화공법에 의한 인공습지 하수처리장에서 하수처리 공정개선에 따른 질소 및 인의 처리효율 향상 방안)

  • Seo, Dong-Cheol;Park, Woo-Young;Lim, Jong-Sir;Park, Chan-Hoon;Lee, Hong-Jae;Kim, Hong-Chul;Lee, Sang-Won;Lee, Do-Jin;Cho, Ju-Sik;Heo, Jong-Soo
    • Korean Journal of Environmental Agriculture
    • /
    • v.27 no.1
    • /
    • pp.27-34
    • /
    • 2008
  • To effectively treat the domestic sewage that was produced on a small-scale in farming and fishing village in order to encourage an ecologically friendly environment, a small-scale sewage treatment apparatus using natural purification methods that consisted of an aerobic and an anaerobic plots were constructed. The efficiency of sewage treatment according to the sewage loading was investigated to obtain the optimum sewage loading in small-scale sewage treatment apparatus. Removal rate of pollutants according to the sewage loading were in the order of $150\;Lm^{-2}day^{-1}{\fallingdotseq}300\;Lm^{-2}day^{-1}>600\;Lm^{-2}day^{-1}$. Therefore, the optimum sewage loading was 300 L m-2 day-1. Under the optimum sewage loading, removal rate of BOD, $COD_{Mn}$, turbidity, T-N and T-P were 99, 94, 99, 49 and 89%, respectively. However, to satisfy the water quality standard in effluent in small-sclae sewage treatment apparatus for domestic sewage treatment, the low removal efficiency of T-N and T-P must be improved. So to improve the removal rate of T-N and T-P, the efficiency of sewage treatment according to the improved sewage treatment process such as, re-treatment at aerobic plot, anaerobic condition of aerobic plot, changing the filter media sizes and the depths in anaerobic plot, and also addition of oyster shells to filter media at anaerobic plot were investigated. In case of 150 cm depth in anaerobic plot with filter medium A (effectivity particle size 1.50 mm) and addition of oyster shells to filter media at anaerobic plot, removal rate of T-N and T-P in both plots were increased by 10 and 3%, and 14 and 7% in comparison with 100 cm depth in anaerobic plot with filter medium B(effectivity particle size 0.95 mm), respectively. The optimum improved sewage treatment process in small-scale sewage treatment apparatus were 150 cm depth in anaerobic plot with filter medium A and addition of oyster shells to filter media at anaerobic plot.

Runoff Characteristics of Non-point Source Pollutants from Road Area During Rainfall Events (강우시 도로지역 비점오염물질 유출특성)

  • Park, Woon Ji;Lee, Su In;Lee, Hae Seung;Lee, Young Joon;Choi, Joong Dae
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2015.05a
    • /
    • pp.403-403
    • /
    • 2015
  • 본 연구에서는 강우시 도로지역에서 발생하는 비점오염물질 유출 및 수질특성을 살펴보고자 도로지역(국도 46호선)을 대상으로 총 16회의 강우사상에 대해 분석하였다. 모니터링 기간(2014년 5월~9월)동안 연구대상지역에는 3.2~80.3 mm의 강우가 발생하였으며, 강우강도는 0.39~11.29 mm/hr의 범위로 나타났다. 선행무강우일수는 0.3~20.1일이며, 총 유출량은 0.1~6.8 ㎥, 유출율은 0.24~0.85(평균 0.6)의 범위로 나타났다. 강우 모니터링 결과, 유량가중평균농도(Event Mean Concentration, EMC)는 TOC 4.9~56.2 mg/L(평균 18.0 mg/L), BOD 3.1~21.5 mg/L(평균 7.5 mg/L), COD 6.7~58.6 mg/L(평균 23.6 mg/L), SS 2.1~281.9 mg/L(평균 59.4 mg/L), T-N 1.07~13.46 mg/L(평균 4.89 mg/L) 그리고 T-P 0.065~0.680 mg/L(평균 0.23 mg/L)의 범위로 나타났으며, 강우계급별로 살펴보면 0~10 mm일 때 BOD 9.3 mg/L, COD 30.5 mg/L, SS 84.1 mg/L, T-N 5.42 mg/L, T-P 0.27 mg/L로, 10~30 mm일 때 BOD 6.6 mg/L, COD 22.0 mg/L, SS 29.0 mg/L, T-N 4.9 mg/L, T-P 0.20 mg/L로, 50 mm 이상의 강우에서는 BOD 3.6 mg/L, COD 7.1 mg/L, SS 46.4 mg/L, T-N 3.42 mg/L, T-P 0.10 mg/L로 강우계급별 EMC는 대부분 수질항목에 있어 10 mm 이하 계급의 평균 EMC가 높은 수준으로 나타났다. 그리고 각 강우사상에 대한 단위면적당 오염부하는 TOC 0.06~3.5 kg/ha, $BOD_5$ 0.03~1.6 kg/ha, CODMn 0.09~4.74 kg/ha, SS 0.09~35.99 kg/ha, T-N 0.012~2.600 kg/ha, T-P 0.001~0.062 kg/ha의 범위로 산정되었다. 도로지역은 불투수층 면적비율이 높아 누적강우량 10 mm 이하에서도 유출이 발생하는 것으로 분석되었으며, 작은 강우에도 초기유출이 발생하고 유출되는 오염물질 농도가 높은 경향을 나타내었다.

  • PDF

Water Quality Improvement by Natural Wetland (습지에 의한 수질개선 효과)

  • Kim, Bom-Chul;Kim, Ho-Sub;Jun, Man-Sig;Hwang, Gil-Son
    • Korean Journal of Ecology and Environment
    • /
    • v.33 no.3 s.91
    • /
    • pp.295-303
    • /
    • 2000
  • The water clarification efficiency was examined in a shallow wetland where dense vegetation was formed naturally in an abandoned paddy field. And, also two enclosure experiments were carried out to measure the effects of materials exchange between sediment and the overlying water with the existence of vegetation and accumulated litter. The hydraulic retention time of wetland was regulated in 1.2 day. The removal rates of SS (56%) and $NO_3-N$ (61%) were high, considering its short retention time. However, removal efficiencies of VSS (28%), COD (14%), DOC (1%),and TP (0.2%) were relatively lower. This low removal efficiencies were thought to be due to the release of dissolved form of organic matter and phosphorus from the sediment. Most of constituents except nitrate were higher in the enclosure at the beginning of enclosure installation than that of the outflowing water from wetland. And then, it has fluctuated and decreased with time. The wetland was in equilibrium state of settling, accumulation of organic debris, and regeneration of dissolved material from sediment. So ultimately high primary production by dense vegetation in the wetland may be the reason of unfavorable or low treatment efficiency of wetland after many years of operation for wastewater treatment. However, the water quality of effluent from the wetland showed smaller variation and better condition than that of inflow, especially during storm events. It can be concluded that this wetland is suitable for the improvement of water quality from nonpoint sources.

  • PDF

Estimation of Contribution Ratio and Community Sewerage Treatment Efficiency by using Advanced Sewage Treatment in the Basin of Hongcheon-river (홍천강 유역의 하수고도처리를 적용한 마을하수처리 효율 및 기여율 평가)

  • Park, Soo-Jin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.7
    • /
    • pp.3570-3576
    • /
    • 2013
  • This paper calculated advanced sewage treatment efficiency and reduction pollution loads to estimation contribution ratio of for community sewerage in Hongcheon-gun County. The A2/O and SBR methods showed overall high treatment efficiency of 95% and 94% respectively, and SS was 80%. On the other hand, T-N and T-P showed relatively low processing efficiency of 56% and 60% respectively, but it was observed that SS showed high 96% in the MBR method. Next, by the result of yearly water change analysis on water quality of Hongcheon River which is the discharge river of community sewerage, it was observed that water quality was greatly deteriorated by COD, T-N and T-P. However, installation and operation of community sewerage showed high pollution load reduction in general water quality item by more than 80%, and in T-N and T-P by 58% and 68% respectively. It is expected that community sewerage will greatly contribute in water quality improvement of Hongcheon River.

Pollutant Contents with Particle Size Distribution in Bridge Road Drainage Sediment (교량도로 배수받이 퇴적물질의 입경별 오염물질 함량)

  • Lee, Jun-Ho;Cho, Yong-Jin;Bang, Ki-Woong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.12
    • /
    • pp.1360-1365
    • /
    • 2007
  • The purpose of this study is to present the basic data for nonpoint pollutant loads from bridge road drainage sediments using the results to analyze organic matter and heavy metals from the four bridge drainage sampling sites with sediments of different particle size ranges. The sediment sample was collected from the bridge road drainage and the masses of nine sediments fractions were obtained after drying the separated sediment in an over at $85^{\circ}C:>2,000{\mu}m$, $1,000\sim2,000{\mu}m$, $850\sim1,000{\mu}m$, $425\sim850{\mu}m$, $212\sim425{\mu}m$, $125\sim212{\mu}m$, $90\sim125{\mu}m$, $75\sim90{\mu}m$, $<75{\mu}m$. The sediment extract was analyzed water quality constituents, including chemical oxygen demand(COD), total nitrogen(T-N), total phosphorus(T-P), heavy metals and particle size distribution. The results indicate that most of particle size ranges of the bridge road sediments was $125\sim425{\mu}m$, and portion of $<75{\mu}m$ was low. But most of the pollutants are associated with the finer fractions of the load sediments. As the results of analysis, the range and average values of COD, T-N, T-P, Fe, Cu, Cr, and Pb were $177\sim198.8$ mg/kg(77.6 mg/kg), $23\sim200$ mg/kg(83 mg/kg), T-P $18\sim215$ mg/kg(129 mg/kg), and $1,508\sim5,612$ mg/kg(3,835 mg/kg), $9.2\sim69.3$ mg/kg(49 mg/kg), $19.1\sim662.2$ mg/kg(214 mg/kg), and $28.4\sim251.4$ mg/kg(114 mg/kg), respectively. The relationship between sediment size and pollutants concentration have an inverse proportion. The removal of road sediments with frequently could be reduced the significant nonpoint pollutant load, because of the bridge road sediment contains considerable micro-particles and heavy metals.

Reduction of Pollutant Load by Small Pond in a Rice Paddy Applied with Pig Manure Compost (돈분퇴비가 시용된 논의 양분유출 저감을 위한 저류지 효과)

  • Kim, Min-Kyeong;Kim, Myung-Hyun;Choi, Soon-Kun;Cho, Kwang-Jin;Hong, Seong-Chang;Jung, Goo-Bok;So, Kyu-Ho
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.22 no.4
    • /
    • pp.21-27
    • /
    • 2014
  • Pig slurry has been considered as environmental waste to be treated in an appropriate manner. Moreover, water-born pollution loads by agricultural non-point source(NPS) pollution are expected to become intensified due to ongoing precipitation change. This study was conducted to develop a best management practice to reduce NPS pollution load by agricultural activity with pig manure compost. An eco-friendly way, small drainage pond, was suggested in this study to avoid direct drainage of agricultural runoffs and eventually reduce the amount of pollutants discharged into the surrounding aqua-environment. A small pond($12m^2$) was constructed at the corner of a rice paddy field($17,15m^2$) located in Suwon, Korea. Water was allowed to drain only via a small drainage pond. Sampling was repeatedly made at two locations, one from an entrance and the other from an exit of a pond, during the rice cultivation period(May to October, 2013). Generally, sampling was made only when runoff water drained through a pond, such as during and/or after rain(irrigation). The water quality analysis showed that all quality parameters(SS, $COD_{Mn}$, T-N, and T-P) were improved as water passed through the pond. The amount of runoff water was reduced by 67.8%. Suspended solids and $COD_{Mn}$ concentrations were reduced by 79.8% and 71.9%, respectively. In case of T-N and T-P amounts, the reduction rates were 73.6% and 74.9%, respectively. Our data implies that agricultural NPS pollution from rice paddy fields with pig manure-based fertilizer can be effectively managed when an appropriate drainage water management practice is imposed.

Water Quality Prediction Model in a Lake by Finite Element Method;Application to Sapkyo Lake (유한요소법에 의한 호소의 수질예측모형;삽교 담수호에 적용하여)

  • Ryu, Byong-Ro;Ahn, Sang-Jin
    • Korean Journal of Environmental Agriculture
    • /
    • v.8 no.1
    • /
    • pp.37-46
    • /
    • 1989
  • A 2-dimensional pollutant transport phenomenon in shallow reservoirs was analyzed by using a finite element method. The Galerkin's weighted residual method, based on linear interpolation, was used and a triangle was adopted as an element. The two dimensional Stock's equation and the advection-diffusion equation integrated over depth were used as governing equations. Also the Newton-Raphson method was introduced to solve the non-linear terms of the equation. The results calculated by the model are in good agreement with the analytical solution for a simplified channel where a known solution is avaiable. An actual application of the model is attempted for Sapkyo Lake with a consideration of the influx of the Sapkyo Chun, the Muhan Chun and kogkyo Chun. Further refined research is needed to evaluate the water quality in the other reservoirs.

  • PDF

Correlation analysis of pollutants using IoT technology in LID facilities (LID 시설 내 IoT 기술을 활용한 오염물질 상관성 분석)

  • Jeon, Minsu;Choi, Hyeseon;kevin, Geronimo Franz;Reyes, N.J.DG.;Kim, Leehyung
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2021.06a
    • /
    • pp.453-453
    • /
    • 2021
  • 도시지역 비점오염원관리, 물순환 회복, 침투 및 증발산량 증가, 열섬현상 저감을 위한 주요한 방안으로 저영향개발(low impact development, LID)과 그린인프라 기법의 적용되고 있다. LID 시설은 소규모 분산형 시설로써 넓은 지역에 많고 다양한 시설들이 적용되어 시설의 개수가 많으며, 수질 및 토양 내 기성제품에 대한 센서들의 가격은 고가로 형성되어 있어 기기의 경제성 및 유지관리 등 적용하는데 제한적이다. 따라서 과거 모니터링 자료를 기반으로 오염물질들과의 상관성 분석을 통하여 계측이 어려운 항목들을 계측가능한 항목들로부터 예측 가능하며, 선정된 항목들에 대한 비용효율적인 센서를 개발하여 실시간 LID 모니터링이 가능한 비용효율적 모니터링을 개발하였다. 공주대학교 천안캠퍼스의 LID 시설들은 2013년에 조성되어 현재까지 시설이 운영되고 있으며, 5년이상의 과거 강우시 모니터링 자료들을 이용하여 오염물질 상관성 분석을 수행가능 하기에 대상지로 선정하였다. 오염물질 상관성 분석은 2013년부터 2017년도에 침투도랑에서 수행된 강우시 모니터링 자료를 활용하여 각 오염물질들의 상관성을 분석을 수행하였다. 침투도랑 내 유입되는 평균 유입수는 TSS 286.1±318.3 mg/L, BOD 22.6±39.5 mg/L, TN 8.96±5.85 mg/L, TP 1.01±1.11 mg/L로 나타났다. 겨울철에 비해 여름철에서의 오염물질의 유입농도가 높은 것으로 분석되었다. 이는 여름철 고온건조로 인한 노면 내 차량의 주행으로 인한 중금속, 폐타이어 등과 장마철 강우 시 유출된 토사로 인하여 유입수의 농도가 높은 것으로 분석되었다. 오염물질 부하량은 TSS와 COD 0.66으로 유의성이 높은 것으로 나왔으며, COD와 TSS, TP, TN 등 유의성이 높은 것으로 분석되었다. Arduino와 Raspberry PI를 활용하여 저비용 센서와 LTE 모뎀통신과 데이터 베이스 연결하여 개발된 프로그램을 통해서 무선으로 LID 시설에 대한 모니터링을 침투화분2와 식생체류지에 조성하였다. 전력공급이 어려운 식생체류지의 경우 태양열(Solar system) 시스템과 보조 전력 배터리를 조성하여 장마철이나 장기적인 악천후로 인한 전력을 생산하지 못할 경우 보조전력배터리에서 전력을 제공하여 지속적인 모니터링이 이루어지도록 설계하였다. 토양함수량, 토양온도와 Conductivity 등 3종류의 센서를 적용하였으며, 프로그램은 현재 2단계를 통한 2차수정을 통하여 프로그램을 구축하였다. 오차, 오작동, 계측값에 대한 검·보정 작업이 필요하다. 또한 대기자료의 구축을 통해 보다 토양과 LID 시설에 대한 영향분석이 필요한 것으로 사료된다.

  • PDF

Comparison of Pollutant Removal Efficiency in Road Sediment with Media Using Filter Separator (필터 분리기를 이용한 여재별 도로퇴적물의 오염물질 제거효율 비교)

  • Bang, Ki-Woong;Lee, Jun-Ho;Choi, Chang-Su;Lee, Sang-Ill
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.3
    • /
    • pp.332-340
    • /
    • 2007
  • Storm runoff from road contains significant loads of particulate and dissolved solids, organic constituents and metal elements. Micro particle is important when considering pollution mitigation because pollutant metal and organics have similar behavior with particles. The objective of this research is to evaluate the hydrodynamic filter separator performance for road storm runoff treatment. A various types of media such as perlite, granular activated carbon, zeolite were used for column test packing media and filter separator, and to determine the removal efficiency with various surface loading rate. As the results of column test, the highest SS removal efficiency was using mixed media(granular activated carbon, zeolite and perlite), and granular activated carbon mixed with zeolite has higher heavy metal removal efficiency than perlite. In laboratory scale hydrodynamic filter separator study, the operation ranges of surface loading rates were from 192 to 1,469 $m^3/m^2/day$. The estimated overall removal efficiencies of hydrodynamic filter separator for typical storm runoff were SS 48.1%, BOD 31.9%, COD 32.6%, TN 15.5%, and TP 17.3%, respectively. For the case of heavy metals, overall removal efficiencies were Fe 26.0%, Cu 19.4%, Cr 25.7, Zn 16.6%, and Pb 15.0%, respectively. The most appropriate medium for hydrodynamic filter separator was perlite mixed with granular activated carbon to treatment of road storm runoff.

Application of Automatic Stormwater Monitoring System and SWMM Model for Estimation of Urban Pollutant Loading During Storm Events (빗물 자동모니터링장치와 SWMM 모델을 이용한 강우시 도시지역 오염부하량 예측에 관한 연구)

  • Seo, Dongil;Fang, Tiehu
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.6
    • /
    • pp.373-381
    • /
    • 2012
  • An automatic flow and water quality monitoring system was applied to estimate pollutant loads to an urban stream during storm events in DTV (Daeduk Techno Valley), Daejeon, Korea. The monitoring system consists of rainfall gage, ultrasonic water level meter, water quality sensors for DO, temperature, pH, conductivity, turbidity and automatic water sampler for further laboratory analysis. All data are transmitted through on-line system and the monitoring system is designed to be controlled manually in the field and remotely from laboratory computer. Flow rates were verified with field measurements during storm events and showed good agreements. Automatic sampler was used to collect real time samples and analyzed for BOD, COD, TN, TP, SS and other pollutant concentrations in the laboratory. SWMM (Storm Water Management Model) urban watershed model was applied and calibrated using the observed flow and water quality data for the study area. While flow modeling results showed good agreement for all events, water quality modeling results showed variable levels of agreement. These results indicate that current options in the SWMM model to predict pollutant build up and wash-off effects are not sufficient to satisfy modeling of all the rainfall events under study and thus need further modification. This study showed the automatic monitoring system can be used to provide data to assist further refinement of modeling accuracy. This automatic stormwater monitoring and modeling system can be used to develop basin scale water quality management strategies of urban streams in storm events.