• Title/Summary/Keyword: COD 감소

Search Result 429, Processing Time 0.029 seconds

SH Wave Scattering from Cracks: Comparisons of Approximate and Exact Solutions (SH파의 균열 산란장 해석: 근사해와 엄밀해의 비교)

  • Jeong, Hyun-Jo;Park, Moon-Cheol;Song, Sung-Jin;Schmerr, L.W.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.24 no.4
    • /
    • pp.354-361
    • /
    • 2004
  • This Paper describes a crack scattering model for SH wave based on the boundary integral equation(BIE) method, where the fundamental unknown is crack opening displacement(COD). When a time harmonic plane wave was incident on a 2-D isolated crack (slit) of width 2a, the COD distributions were numerically calculated as a function of ka. The calculated COD agreed well with results obtained with other methods. The far-field scattering amplitude, which completely characterizes the flaw response, was calculated in two ways. The Kirchhoff approximation and the BIE-COD exact formulation were compared in terms of incidence angle and frequency ka in a pulse-echo mode. Maximum response was obtained for both methods at the specular reflection direction. Away from the specular direction, the Kirchhoff approximation becomes less accurate. The time domain crack response was also calculated using a band-limited spectrum of center frequency 10 MHz. At oblique incidence to the crack both methods show the existence of an antisymmetric flash points occurring from the crack edge. The Kirchhoff approximation provides an exact time interval between flash points, although it unrealistically gives the same amplitude.

Comparison of Water Quality Before and After Four Major River Project for Water Monitoring Stations Located Near 8 Weirs in Nakdong River (낙동강 8개 보 인근 수질측정 지점의 4대강 사업 전·후 수질 변동성 분석)

  • Cho, Hyun Kyung;Lim, Hyo Jin;Kim, Sang Min
    • Journal of agriculture & life science
    • /
    • v.52 no.6
    • /
    • pp.89-101
    • /
    • 2018
  • The purpose of this study was to evaluate the variation of water quality in the Nakdong River by the Four major river projects. For this purpose, the nearest upstream water quality monitoring stations were selected and water quality data such as BOD, COD, SS, TN, TP, and TOC were collected for the before Four major river project(from January 2003 to November 2008), during the project(from September 2008 to April 2012) and after the project(from May 2012 to September 2017). As a result, the concentration of DO, BOD, COD, TN, and TOC after the project tend to be higher than the before project period. On the other hand, the SS and T-P values decreased after the project. Spatial analysis of BOD, COD, and TOC, which have large changes in water quality factor, by water quality grade, showed a tendency that water quality grade after the project was worse than before the project.

Biosorption Characteristics of Organic Matter in a Sequencing Batch Reactor : Effect of Sludge Retention Time (연속 회분식 반응기내 유기물 생물흡착특성: SRT 영향)

  • Kim, Keum-Yong;Kim, Jin-Hyung;Kim, Dae-Keun;Ryu, Hong-Duck;Lee, Sang-Ill
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.2
    • /
    • pp.175-180
    • /
    • 2008
  • The objective of this study was to investigate biosorption of organic matter on EPS(Extracellular Polymeric Substances) at different SRT(Sludge Retention Time) in a SBR(Sequencing Batch Reactor) process, which was operated with the following operation steps : Fill-React-Settle-Decant-Idle. The hydraulic retention time was set to be 24 hours. The results obtained from this study showed that the organic removal efficiency per unit microbial biomass decreased with increasing SRT, and the corresponding EPS amount also did. The percent removal of organic by biosorption increased with SRT, and it reached to 53.2% at SRT of 30 days. However, the highest biosorption per microbial biomass(48.6 mgCOD/gVSS) was found at SRT of 2 days. The EPS analysis was performed by measuring TSS, TCOD$_{Cr}$, and TKN. The EPS production per unit microbial biomass was observed to be high at a low SRT. Due to the above result, the floc formation was hindered and therefore poor settlement of sludge resulted in decreasing the COD removal efficiency. It was therefore concluded that the consideration of the system design should include the characteristic of EPS as well as other factors such as SRT, MLSS, and organic loading.

Study on Characteristics of Solubilization for Sewage Sludge Using Electronic Field and Ultrasonification (전기장과 초음파를 이용한 하수슬러지의 가용화 특성 연구)

  • Seo, Jang-Won;Han, Ji-Sun;Ahn, Chang-Min;Min, Dong-Hee;Yoo, Yeon-Sun;Yoon, Soon-Uk;Lee, Jong-Gyu;Lee, Jong-Yeon;Kim, Chang-Gyun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.9
    • /
    • pp.636-643
    • /
    • 2011
  • Sludge solubilization using sonification has been increasingly used for sludge volume reduction along with enhancing digestion efficiency during anaerobic biogas production. In this study, either electric field or ultrasonification or in combination with were investigated using three types of sludge (return, excess and mixed at G sewage treatment facility) for the most efficient solubilization. As a the closed loop, 200 L of sludge was continuously passing through the solubilization system at an average flow rate of $0.7m^3/h$, which is equivalent to 3.5 times treated per hour for up to 84 times (24 h). Only implying electric field showed no variation for sCOD/tCOD before and after treatment on sludge solubilization regardless of types of sludge. However, employing the ultrasonic or combined system could both increasingly solubilize sludge with regard to the number of passing-through, which more enhanced by the combined. In addition, VSS/TSS was lowered to in the range of 2 and 6% while its particle size, diameter (0.9) and diameter (0.5) were more minimized than that of raw sludge. For return sludge, ultrasonification was more efficiently facilitated for solubilization, whereas electric field-ultrasonification was more preferably applied for excess and mixed sludge. It is concluded that depending on types of sludge, solubilization system must be selectively applied for the most efficient break-up of them.

Influence of Applied Voltage for Bioelectrochemical Anaerobic Digestion of Sewage Sludge (하수슬러지의 생물전기화학 혐기성소화에 대한 인가전압의 영향)

  • Kim, Dong-Hyun;Song, Young-Chae;Qing, Feng
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.37 no.9
    • /
    • pp.542-549
    • /
    • 2015
  • The bioelectrochemical anaerobic digestion for sewage sludge was attempted at different applied voltages ranged from 0.2 V to 0.4 V. At 0.3 V of the applied voltage, pH and VFAs were at 7.32 and 760 mg COD/L, respectively, which were quite stable. The methane production rate was $1.32L\;CH_4/L.d$, and the methane content in biogas was 73.8%, indicating that the performance of the bioelectrochemical anaerobic digestion could be considerably improved by applying a low voltage. At 0.4 V of the applied voltage, however, the contents of the minor VFA components including formic acid and propionic acid were increased. The methane production rate was reduced to $1.24L\;CH_4/L.d$ and the biogas methane content was also reduced to 72.4%. At 0.2 V of the applied voltage, the pH was decreased to 6.3, and VFAs was accumulated to 5,684 mg COD/L. The contents of propionic acid and butyric acid in the VFAs were considerably increased, The performances in terms of the methane production rate and the biogas methane content were deteriorated. The poor performance of the bioelectrochemical reactor at 0.2 V of the applied voltage was ascribed to the thermodynamic potential lack for the driving of the carbon dioxide reduction into methane at cathode.

Initial Change of Environmental factors at Artificial Tidal Flat Constructed Using Ocean Dredged Sediment (해양 준설토를 이용한 인공염습지 현장시험구 조성 후 초기 환경변화)

  • Park, So-Young;Lee, In-Cheol;Yi, Byung-Ho;Lee, Ja-Yeon;Yi, Yong-Min;Sung, Ki-June
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.11 no.2
    • /
    • pp.63-69
    • /
    • 2008
  • As a basic study on the creation of artificial tidal flats using dredged sediments, the pilot-scale artificial tidal flats with 4 different mixing ratio of ocean dredged sediment were constructed in Nakdong river estuary. The phragmites australis was transplanted from the adjacent phragmites australis community after construction, and then the survival and growth rate of the planted phragmites australis were measured. Also the changes of soil chemical oxygen demand (COD), ignition loss (IL), and the heterotrophic microbial numbers were monitored. The survival rate of the planted phragmites australis decreased as the mixing ratio of dredged sediment increased but there was little difference of length and diameter of the shoots. 30% of COD and 9% of IL in the tidal flat with 100% dredged sediment decreased after 202 day, however, fluctuations of COD and IL concentrations were also observed possibly due to the open system. It was suggested that the construction of tidal flats using ocean dredged sediment and biological remediation of contaminated ocean dredged sediment can be possible considering the growth rate of transplanted phragmites australis, decrease of organic matter and increased heterotrophic microbial number in the pilot plant with 100% dredged sediment. However, the continuous monitoring on the vegetation and various environmental factors in the artificial tidal flat should be necessary to evaluate the success of creation of artificial flats using dredged sediments.

  • PDF

Effects of Seed Sources and Concentration of Ammonia on Anaerobic Digestion (혐기성 소화에 대한 식종원 및 암모니아 농도의 영향)

  • Kim, Yang-Ji;Kim, Sung-Il;Shin, Bum-Shic;Ahn, Ki-Sup;Kim, Jong-Soo
    • Korean Journal of Environmental Agriculture
    • /
    • v.23 no.1
    • /
    • pp.1-6
    • /
    • 2004
  • The seeding sources and concentration of ammonia on anaerobic digestion were investigated by batch culture bioreactors. The sources of seeding on anaerobic digestion were from swine wastewater collection pit of a hog raising farm and from anaerobic digestion sludge of a municipal sewage treatment plant. The inhibition of ammonia on anaerobic microorganisms was initiated at ammonia concentration of $1,500\;mgNH_4-N/L$ and it's effect was increased by increased by increasing ammonia concentration up to $3,500\;mgNH_4-N/L$ regardless the sources of seeding as evidenced by decreases in COD removal efficiencies and biogas yields. The inhibition occurred to not only methanogens but also acidogens since the concentration of volatile fatty acids was maintained at 50 mg/L The COD removal efficiency and biogas yield were Maintained constantly while increasing ammonia concentration up to $3,500\;mgNH_4-N/L$ when swine wastewater collection pit was used as a seeding; however, those were decreased while increasing ammonia concentration when anaerobic digestion sludge was used as a seeding. The results indicate that the seeding acclimated to high concentrations of ammonia for long time was easy in adaptation to high ammonia concentration and less subjective to ammonia inhibitory effects.

표면 사이즈용 전분이 백상지 품질에 미치는 영향

  • 윤지영;정경태;김대현;이중근;이용규
    • Proceedings of the Korea Technical Association of the Pulp and Paper Industry Conference
    • /
    • 2001.11a
    • /
    • pp.45-45
    • /
    • 2001
  • 종이 표변에 전분 사이징을 하는 목적은 종이가 액체에 대하여 침투저항성을 부여하 여 종이의 인쇄적성을 향상시키며 아울랴 종이의 표면적성과 종이강도 등의 물리적 특 성을 향상시키기 위해서 사용된다. 표면 사이징은 기본적으로 종이 표면에 전분을 이용 한 필름을 형성하여 종이 표면의 공극크기를 줄여 인쇄잉크 등과 같은 액체의 침투속 도를 늦여준다. 현재 국내에서 널리 사용되는 표면 사이징용 전분으로는 산화전분과 자 가변성용 일반전분이 있다. 자가변성용 전분은 효소나 APS로 전분의 chain 길이를 적 당한 점도로 잘라주는 것으로 전분 호액의 노화가 쉽게 일어나는 경향이 있다. 산화전 분은 전분회사에서 산화제를 이용하여 전분의 점도를 사용자의 요구에 따라 조절한 것 으로 water holdout이 개선되고 자가변성용 전분보다는 노화 안정성이 개선되지만 종 이 내부로의 칩투가 많이 일어나 전분 필름 강도가 약해지며 표면 강도 향상 효과가 적고 종이의 광학적 특성을 저하시키는 단점을 지니고 있다. 또한 약 10 ~ 20% 정도 사 용되는 파지의 재활용시 펄프 섬유에 흡착되지 않는 전분으로 인해 백수 내의 COD 및 B BOD를 증가시키는 원인이 된다.따라서 본 연구에서는 펄프 섬유와 친화력이 높아 지료 내첨용 지력증강제로 널리 사용되고 있는 양성 전분의 양이온 치환도 및 점도를 사이즈 프레스에 적합하게 조절 하여 백상지 제조업체의 라언에 적용하였다. 결과분석 항목으로는 파지 재활용에 따른 백수내 COD, 칼숨 이온함량 등의 백수 시스템의 변화와 종이의 물리적, 광학적 특성 및 ink jet 용지의 인쇄적성 등을 측정하여 산화전분과 비교하였다. 그 결과 약 20%의 C COD 감소 효과와 10%정도의 OPR 향상 효과를 얻을 수 있었다. 종이 물성의 경우 인 장강도와 뺏뺏이(stiffness) 및 지분 등을 측정한 결과 산화전분 보다 향상되었다. 특히 지분의 경우, 참여한 회사의 지분관련 complain이 약 80% 정도 감소하는 결과를 나타 내었다. 또한 백상지의 경우 ink jet 프린터에 많이 사용됨으로 ink jet 프린터의 인쇄 적성을 image analyzer로 측정한 결과 산화전분 보다 향상된 결과를 나타내었다.

  • PDF

Toxicity Assessment and Evaluation of the Applicability of a Constructed Wetland of Bio-reeds and Bio-ceramics (바이오갈대와 바이오여재를 적용한 인공습지의 효율성 및 독성평가)

  • Park, Da Kyung;Chang, Soon-Woong;Choi, Hanna
    • Korean Journal of Environmental Biology
    • /
    • v.35 no.4
    • /
    • pp.654-661
    • /
    • 2017
  • Recently, a low-impact development (LID) technic such as a wetland has been proposed as a Nature-friendly process for reducing pollutants caused by livestock wastewater. Therefore, the Daphnia magna toxicity was analyzed for livestock wastewater samples, to determine if a wetland system would also be effective in reducing this ecotoxicity. In the present study, acute D. magna toxicity was not significantly dependent on the presence and type of reed, nor type of media. However, when treated with construction wetlands, ecotoxicities decreased as well as TN, TP and COD concentrations. Therefore, it is considered that a construction wetland system with bio reeds and bio-media as well as general reeds would be effective to reduce the ecotoxicity of livestock wastewater. To apply a wetland system as the subsequent treatment process to a livestock waste water treatment facility, it is necessary to perform an integrated evaluation such as treatment efficiency and the ecotoxicity test for various characteristics of livestock wastewater.

Determination of Optimum Dosage of Polymer by Zeta potential in the Wastewater Treatment (수처리 시 Zeta전위 측정에 의한 응집제 주입량 결정)

  • Cho, Jun-Hyung;Kang, Mee-Ran
    • Journal of Forest and Environmental Science
    • /
    • v.22 no.1
    • /
    • pp.27-31
    • /
    • 2006
  • Sedimentation characteristics such as SS, COD removal efficiency of wastewater in the toilet paper mill using recycled paper were examined by zeta potential. Optimum dosage of coagulant were determined by turbidity, SS, COD and then equation for treatment efficiency was suggested. Mechanical strength of floc was determined by turbidity.

  • PDF