• Title/Summary/Keyword: COD 가용화

Search Result 27, Processing Time 0.036 seconds

The Effect of Solubilization Pretreatment Process on Anaerobic Digestion of Waste Activated Sludge (전처리 가용화 공정이 잉여슬러지 혐기성 소화효율에 미치는 영향)

  • Yoo, Ho-Sik;Ahn, Seyoung
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.24 no.3
    • /
    • pp.35-43
    • /
    • 2016
  • COD properties of waste activated sludge (WAS) were investigated for various solubilization rate of mechanical pretreatment method in anaerobic digestion process. Inert COD was 37.0% of total COD in untreated WAS. Particulate biodegradable COD was converted to soluble biodegradables and particulate unbiodegradables as solubilization was processed. Particulate unbiodegradable portion of COD in WAS can be increased as particulate biodegradable portion is decreased in case of relatively long SRT of biological treatment. Thus, COD properties of WAS should be investigated in case of relatively low particulate biodegradable COD, because of possible low effect of solubilization. COD removal rate in anaerobic digester was enhanced as much as 2.1% and 15.1% for solubilization rate 5% and 35% due to pretreatment, respectively. COD removal rate was increased from 25% to 40%, and methane gas generation was increased from $607m^3/d$ to $907m^3/d$ as particulate COD of WAS was solubilized to 35% in pretreatment facilities.

The Effect of Strong Acid and Ionic Material Addition in the Microwave-assisted Solubilization of Waste Activated Sludge (Microwave를 이용한 폐활성슬러지의 가용화 반응에서 강산과 이온성 물질의 첨가가 미치는 영향)

  • Lee, Jeongmin;Lee, Jaeho;Lim, Jisung;Kim, Youngwoo;Byun, Imgyu;Park, Taejoo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.37 no.1
    • /
    • pp.60-68
    • /
    • 2015
  • The study of waste activated sludge (WAS) solubilization has been increased for sludge volume reduction and enhancing the efficiency of anaerobic digestion. Microwave (MW)-assisted solubilization is an effective method for the solubilization of WAS because this method can lead to thermal, nonthermal effect and ionic conduction by dielectric heating. In this study, the solubilization of WAS by MW heating and conductive heating (CH) was compared and to enhance the MW-assisted solubilization of WAS at low MW output power, chemical agents were applied such as $H_2SO_4$ as the strong acid and $CaCl_2$, NaCl as the ionic materials. Compared to the COD solubilization of WAS by CH, that by MW heating was approximately 1.4, 6.2 times higher at $50^{\circ}C$, $100^{\circ}C$, respectively and the highest COD solubilization of WAS was 10.0% in this study of low MW output power condition. At the same MW output power and reaction time in chemically agents assisted experiments, the COD solubilization of WAS were increased up to 18.1% and 12.7% with the addition of $H_2SO_4$ and NaCl, however, that with the addition of $CaCl_2$ was 10.7%. This result might be due to the fact that the precipitation reaction occurred by calcium ion ($Ca^{2+}$) and phosphate ion (${PO_4}^{3-}$) produced in WAS after MW-assisted solubilization. In this study, $H_2SO_4$ turned out to be the optimal agent for the enhancement of MW efficiency, the addition of 0.2 M $H_2SO_4$ was the most effective condition for MW-assisted WAS solubilization.

Evaluation of COD Solubilization and Reduction of Waste Activated Sludge by pH Control (pH 조절을 통한 폐활성 슬러지의 COD 가용화 및 감량화 평가)

  • Kim, Youn Kwon;Moon, Yong Taik;Kim, Ji Yeon;Seo, In Seok
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.21 no.5
    • /
    • pp.551-558
    • /
    • 2007
  • From the view point of biological wastewater treatment, C/N ratio is one of the most important factor in biological nutrient removal process. However, municipal sewage in Korea is characterized by extremely low content of carbon source and relatively higher portion of N source. Accordingly, it is necessary to dose external carbon source in order to obtain higher degree of carbon source within the process. In this study, the effects of pH pretreatment as an alternative plan for increasing carbon source on the cell disruption and COD solubility of waste activated sludge were conducted under well defined experimental conditions. During 5 hours, the value of COD solubilization rate ($S_R$) at pH 11.5 is approximately 4.4 times higher than the value of $S_R$ at pH 9.5. It is expected that the level of SCOD increased due to the result from cell disruption. However, VSS/TSS ratio was not significantly changed after 5 hours. As Alkalinity changes gradually from less than 15, 30 and 60 meq NaOH/L, average RBCOD/SCOD fraction showed 34, 36 and 45%,respectively.

Study on Characteristics of Solubilization for Sewage Sludge Using Electronic Field and Ultrasonification (전기장과 초음파를 이용한 하수슬러지의 가용화 특성 연구)

  • Seo, Jang-Won;Han, Ji-Sun;Ahn, Chang-Min;Min, Dong-Hee;Yoo, Yeon-Sun;Yoon, Soon-Uk;Lee, Jong-Gyu;Lee, Jong-Yeon;Kim, Chang-Gyun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.9
    • /
    • pp.636-643
    • /
    • 2011
  • Sludge solubilization using sonification has been increasingly used for sludge volume reduction along with enhancing digestion efficiency during anaerobic biogas production. In this study, either electric field or ultrasonification or in combination with were investigated using three types of sludge (return, excess and mixed at G sewage treatment facility) for the most efficient solubilization. As a the closed loop, 200 L of sludge was continuously passing through the solubilization system at an average flow rate of $0.7m^3/h$, which is equivalent to 3.5 times treated per hour for up to 84 times (24 h). Only implying electric field showed no variation for sCOD/tCOD before and after treatment on sludge solubilization regardless of types of sludge. However, employing the ultrasonic or combined system could both increasingly solubilize sludge with regard to the number of passing-through, which more enhanced by the combined. In addition, VSS/TSS was lowered to in the range of 2 and 6% while its particle size, diameter (0.9) and diameter (0.5) were more minimized than that of raw sludge. For return sludge, ultrasonification was more efficiently facilitated for solubilization, whereas electric field-ultrasonification was more preferably applied for excess and mixed sludge. It is concluded that depending on types of sludge, solubilization system must be selectively applied for the most efficient break-up of them.

Effect of electrode coating and applied voltage of pulsed electric fields (PEF) on sludge solubilization (펄스전기장 (Pulsed Electric Fields)의 전극 코팅과 인가 전압에 따른 슬러지의 가용화 효과)

  • Um, Se-Eun;Chang, In-Soung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.10
    • /
    • pp.16-23
    • /
    • 2018
  • Alternative technologies for sludge treatment and disposal need to be developed urgently because the amount of produced production has increased continuously. In this study, Pulsed Electric Fields (PEF) technique was applied for sludge solubilization and the performance was evaluated. The PEF equipped with electrodes coated by epoxy resin and teflon was inducted to the activated sludge suspension, and the effect of the coating materials on the solubilization was determined. In addition, the effect of the applied voltage on the solubilization yield was investigated as the applied voltage was increased from 6 to 12 and 15 kV. Sludge solubilization was not observed when the epoxy-coated electrode was used for PEF induction regardless of the applied voltage. However, sludge solubilization occurred when 12 and 15 kV were applied to the teflon-coated electrodes. The MLSS decreased to 9%, and the soluble-COD increased to 496% when the applied voltage was 15 kV. But sludge solubilization did not happen under 6 kV condition. The corona discharge was observed at applied voltages of 12 and 15 kV, (Ed- sorry but I cannot understand the following highlight) but if 6 kV, strongly indicating that the corona discharge make the sludge solubilized, which suggests that the critical voltage for sludge solubilization lies between 6 and 12 kV. Consequently, proper selection of electrode-coating materials and the applied voltage of PEF could lead to sludge solubilization by corona discharge.

A Study on Characteristics of Solubilization and Biogas Production for Sewage Sludge using Thermal Pretreatment (열적가용화공정을 이용한 하수슬러지의 가용화 특성 및 바이오가스 생산량 평가)

  • Jeong, Seong-Yeob;Yeon, Ho-Suk;Lee, Chang-Yeol;Lee, Jong-In;Chang, Soon-Woong
    • Resources Recycling
    • /
    • v.24 no.2
    • /
    • pp.46-54
    • /
    • 2015
  • In this study, an applicability of thermal pretreatment for primary and secondary sludge, which are generated in a sewage treatment plant, was evaluated. The efficiency and charateristics was investigated with each sludge after pretreatment under the condition of $100{\sim}220^{\circ}C$ for 30 minutes. As the result, it was found that $SCOD_{Cr}$, $NH_4{^+}$, VFAs concentrations increased as the pre-treatment temperature increased. For COD solubilization, it was also highly dependent on an increase of temperature resulting in acceleration on hydrolysis and acid fermentation. In the BMP (Biochemical Methane Potential) experiment, for the primary sludge, it showed the higher biogas production rate at a temperature of $220^{\circ}C$, however, the effect was insignificant (5.6%). Whereas, for the secondary sludge, the increase on biogass production rate was 38.8% ($180^{\circ}C$) and this means that the secondary sludge is more suitable for an applicability of thermal pretreatment.

Solubilization of Sewage Sludge by Inoculation of Lactic Acid Bacteria (유산균 접종에 의한 하수 슬러지의 가용화)

  • Yang, Hyun-Sang;Lee, Jung-Eun;Lee, Eun Young
    • Microbiology and Biotechnology Letters
    • /
    • v.36 no.3
    • /
    • pp.233-239
    • /
    • 2008
  • A new approach to the solubilization of excess activated sludge by the inoculation of lactic acid bacteria was studied to reduce the amount of sludge produced in the activated sludge treatment process. Aerobic microorganism in sludge was lysed in anaerobic condition and the cytoplasmic substance eluted was utilized as a carbon source by lactic acid bacteria. On the basis of sludge solubilization efficiency, Lactobacillus brevis and Leuconostoc mesenteroides subsp mesenteroides were selected the best candidates among five kinds of Lactobacillus sp. and seven kinds of Leuconostoc sp. The sludge solubilization efficiency by heterofermentative lactic acid bacteria was more efficient than that of homofermentative bacteria. Initial value of soluble COD (sCOD) was 1050 mg/L at the initial inoculation time increased to 3070 mg/L (192% solubilization) at 96 h of the incubation time. The inoculation of lactobacillus brevis to the sludge resulted in 2824% increase in sCOD value after 96 h of incubation than the control experiment. Leuconostoc mesenteroides subsp mesenteroides showed 152% increase of solubilization and 30% increase of S-COD/T-COD on 96 h of incubation time. Considering the increase of S-COD by the inoculation of Leuconostoc sp. on 24 h, 10% inoculation of lactic acid bacteria to the sludge was most effective.

Application of Non-Thermal Plasma for the Simultaneous Removal of Odor and Sludge (무기악취와 슬러지 동시처리를 위한 저온플라즈마의 적용)

  • Hwang, Hyun-Jung;Ann, Hae-Young;Shin, Seung-Kyu;Song, Ji-Hyeon
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.24 no.1
    • /
    • pp.85-92
    • /
    • 2010
  • In this study, odorous compounds emitted from various wastewater treatment were treated with using the non-thermal plasma reaction, and the effluent gas from the plasma reactor was introduced to a waste sludge reactor to achieve simultaneous sludge reduction. Hydrogen sulfide, the model odorous compound, was removed at 70% using the plasma reaction, and greater than 99% removal efficiency was observed when treated by the sludge reactor. In addition, the sludge reactor showed a high efficiency of ozone removal. As ozone reacted with sludge, oxidation with organic matters took place, and total COD decreased by 50~60% and soluble COD increased gradually. As a result, the integrated process consisting of the non-thermal plasma and the sludge reactor can be successfully applied for the simultaneous treatment of malodorous gas and waste sludge.

A Study of Sewage Sludge Solubilization by Alkali and Ultrasonic pretreatment (알칼리처리와 초음파처리를 이용한 슬러지 가용화 연구)

  • Kim, Jae-Hyung;Yang, Hong-Gyu;Lee, Joon-Cheol;Park, Hong-Sun;Choi, Gwang-Geun;Pak, Dae-Won
    • Journal of Energy Engineering
    • /
    • v.20 no.2
    • /
    • pp.84-89
    • /
    • 2011
  • In this study, individual(alkaline, ultrasonic) and combined(alkaline+ultrasonic) pretreatment effect on sewage sludge solubilization was investigated. COD solubilization rates increased with the dose of NaOH added: solubilization reached 27.6%. Additional alkaline agents did not increase solubilization further. Ultrasonic pretreatment achieved 33~39% solubilization when 140 W/L amplitude. In(alkaline(pre-treatment)+ultrasonic (after-treatment)) treatment, solubilization increased as the combined intensity in creased($70.4{\pm}9.4%$). SCOD rising rate(0.076) was achieved.

Study on solubilization of sewage sludge using electrolysis techniques (전기분해에 의한 하수슬러지 가용 효과 연구)

  • Lee, Ji-Sun;Chang, In-Soung;Lee, Chul-Ku;Joung, Seun-Young
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.2
    • /
    • pp.979-984
    • /
    • 2011
  • Although sludge production has been increased due to the number of the wastewater treatment plants expanded, needs of the techniques for the sludge reduction and disposal has been issued importantly because the sludge dumping to ocean is prohibited from 2012 by the London Dumping Convention. Therefore, the sludge solubilization using electrolysis as an alternative techniques for the sludge disposal was carried out in this study. Iridium coated titanium based insoluble electrodes were used and 20 volt was applied to the electrolysis reactor using DC power supply. Supernatants of the treated sludge was monitored: The soluble COD, TN, TP of it was increased to 151%, 22% and 6% respectively. And the sludge floc size distribution was changed, that is, the flocs ranged from 0.1 to 1.0 ${\mu}m$ were increased. All of these results indicate that the cells were lysed and the internal matters bursted out of the cell after electrolysis. As well as the reduction of the sludge production, the soluble organic matters from the cells could be used as an external carbon sources in the advanced wastewater treatment plants.