• 제목/요약/키워드: CO laser

검색결과 1,343건 처리시간 0.024초

산부인과 펄스형 $CO_2$ 레이저의 펄스 특성에 의한 안정된 동작파형의 시스템 (System of stable action waveform by pulse special quality of obstetrics and gynecology pulse style $CO_2$ laser)

  • 김휘영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 심포지엄 논문집 정보 및 제어부문
    • /
    • pp.55-57
    • /
    • 2007
  • $CO_2$ laser sees that is most suitable to get this effect through minimum formation damage and advantage that is root enemy of effect that happen in minimum cellular tissue depth of 0.1mm is stable living body organization or internal organs institution. Formation damage by ten can be related in formation's kind or energy density, length of evaporation time. If shorten evaporation time, surroundings cellular thermal damage 200 - because happen within 400ums laser beam in rain focus sacred ground surroundings cellular, tissue without vitiation me by evaporation Poe of very small floor as is clean steam can. Application is possible to vulva cuticle cousins by a paternal aunt quantity, uterine cancer, cuticle tumor by laser system that $CO_2$ laser gets into standard in obstetrics and gynecology application. Because effect that super pulse output is ten enemies of laser if uniformity one pulse durations are short almost is decreased, most of all pulse module special quality of pulse style $CO_2$ laser for obstetrics and gynecology mode stabilization by weight very, in this research to get into short pulse duration and higher frequency density, do switching by high frequency in DC-DC Converter output DC's ripple high frequency to be changed, high frequency done current ripple amount of condenser for output filter greatly reduce can. Ripple of output approximately to Zero realization applying possible inductor realization through a special quality experiment do.

  • PDF

CO2 레이저를 이용한 음각 원뿔 구조 광섬유 팁 가공 최적화 연구 (CO2 Laser micro-structuring of optical fiber with negative conical shape)

  • 유동윤;최훈국;손익부;노영철;정덕;김영섭;이호;김창환
    • 한국레이저가공학회지
    • /
    • 제18권3호
    • /
    • pp.14-19
    • /
    • 2015
  • A helical fabricating method using $CO_2$ laser was utilized for producing cone-shaped structure on a silica substrate. Output power and the number of scanning radiation were modified in order to control the structure. The experiment shows that the depth and width of cone-shape were increased with higher output power of the laser and the number of scanning. We demonstrate fabrication of multidirectional side-firing optical fiber with diameter of 440 um using the $CO_2$ laser fabrication technique.

후두미세수술에서 탄산가스 레이저를 이용한 레이저 수술의 안전성 (Laser Safety in Laryngeal Microsurgery Using $CO_2$Laser)

  • 이정구;정필상;정필섭
    • 대한기관식도과학회지
    • /
    • 제4권2호
    • /
    • pp.159-164
    • /
    • 1998
  • The developmental and subsequent addition of laser technology to existing surgical techniques offered new and exciting Possibilities for improving traditional endoscopic operations and expanding the scope of the specialty of otolaryngology-head and neck surgery. Lasers were found to be Precise, but potentially dangerous, surgical instruments whose use was associated with certain distinct and unprecedented advantages, but also with many unique and potentially serious, and sometimes catastrophic complications. The Purpose of this study was to evaluate the of elation technique of $CO_2$laser, kinds of anesthesia, equipments of operating room, and education of medical staff. Four hundreds 4 cases of $CO_2$laser laryngeal microsurgery were reviewed for the safety of $CO_2$laser in laryngeal microsurgery. Vocal polyp (46,3%) was the most common pathology in our cases. The others were vocal nodule, Reinke`s edema, epiglottic cyst, laryngeal granuloma, laryngeal papilloma, intracordal cysts, laryngeal tuberculosis, laryngeal web, laryngotracheal stenosis, and laryngeal cancer. Following complete equipment controls, treatment area controls, maintenance, service and procedural controls, personel protective equipment, and warning signs, no complications were found in our cases. In conclusion, laryngeal microsurgery with $CO_2$laser could be done safely without complication if complete preoperative preparation and education of medical staff preceded.

  • PDF

레이저를 이용한 임프란트 이차수술시 온도변화에 관한 실험적 연구 (TEMPERATURE CHANGES OF IMPLANT SURFACE IN SECOND STAGE SURGERY WITH DETAL LASER : IN VITRO STUDY)

  • 안현정;김현철;최병갑;송언희;김래경
    • 대한치과보철학회지
    • /
    • 제37권2호
    • /
    • pp.256-268
    • /
    • 1999
  • Submerged implants require secondary surgical uncovering of implants after healing period of 3-6 months. In surgical methods, there are surgical scalpel, tissue punch, electro-surgical, and laser-used uncovering, and so forth The objectives of this study are investigation and assessment of 1) thermal change in clinical application for uncovering of HA-coated implant and pure titanium implant irradiated by pulsed Nd-YAG, $CO_2$, and Er-YAG laser. 2) surface change of cover screws aaer irradiation using laser energy. The temperature of apex & side wall of implants were recorded at 10sec, 20sec, 30sec after 30sec irradiation to implant healing screw; 1) pulsed Nd-YAG laser; 2W, 20pps, contact mode 2) $CO_2$ laser; water-infused & non-water infused state, 2.5-3.5W, contibuous mode, noncontact mode 3) $CO_2$ laser ; non-water infused state, 3W, superpulse, noncontact. mode 4) Er-YAG laser; (1) non-water infused state, 10pps, 60mj, contact mode (2) water-infused state, 10pps, 60mj, 80mj, 101mj, contact mode. According to the results of this study, pulsed Nd-YAG laser is not indicated because of increased thermal change and pitting of metal surface of implant cover screw. By contrast, $CO_2$ laser & Er-YAG laser are presumed to indicate because of narrow range of thermal change & near abscence of thermal damage of metal surface. Dental laser is thought to be much helpful to surgical procedure when it is used as optimal power and time condition considering characteristics and indications of each laser. Further research is needed to verify that these techniques are safe and beneficial to implant success.

  • PDF

방전 플라즈마 빛의 검출량과 CO2레이저 출력의 상관관계 (The relativity of the emitted light of discharge plasma and C02 laser output)

  • 김태균;이임근;최진영;김희제
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 C
    • /
    • pp.1954-1956
    • /
    • 2004
  • Nowadays, $CO_2$ lasers are used widely in many applications such as materials fabrication, communications, remote sensing and military purpose etc. Especially, $CO_2$ lasers are in the spotlight at surface handling and heat processing. It is important to control the laser output power and beam Quality in those fields. And those are studied the important parameters deciding the fluctuation of laser beam are smoothing capacitor, frequency and the characteristics of laser resonator. But the study of plasma parameters of $CO_2$ lasers are little. So we detect the $CO_2$ laser from emitted $CO_2$ laser discharge plasma using a non-contact photo tansistor sensor and Low pass filter. In this study, The relativity of the emitted light of discharge plasma and CO2 laser output.

  • PDF

돼지에서 $CO_2$ laser와 외과용 수술도를 이용한 위 절개 시 창상 치유 평가 (Comparative Study of Wound Healing in Porcine Stomach with $CO_2$ Laser and Scalpel Incisions)

  • 변홍섭;이재연;김명철
    • 한국임상수의학회지
    • /
    • 제30권4호
    • /
    • pp.247-252
    • /
    • 2013
  • We compared wound healing with $CO_2$ laser incision and scalpel incision by measuring the extent of bleeding, the ease of incision, time, degrees of adhesion and histological observation in pig's stomach. Eight healthy pigs were used. Two symmetrical incisions were made in ventral aspect of the stomach between the greater curvature and lesser curvature were made with scalpel and 2 mm spot diameter $CO_2$ laser (8W, continuous wave) in eight pigs. And then each wound was closed with absorbable suture in a two-layer inverting seromuscular pattern. At 7 and 14 days after initial wounding, each wound was taken for histological observation. On surgery, the extent of bleeding, the ease of incision and incision time showed significant differences between the two groups. The $CO_2$ laser provided better hemostasis (p < 0.01) and smaller postoperative adhesion compared with the scalpel. However, the scalpel produced faster speed of incision and was easier to handle than the $CO_2$ laser group (p < 0.01). There was no considerable difference between the two groups in histological observation.

보호가스 종류에 따른 고출력 레이저 용접특성 (The Effect of Shielding Gas Composition on High Power Laser Welding Characteristics)

  • 안영남;김철희
    • Journal of Welding and Joining
    • /
    • 제33권4호
    • /
    • pp.17-23
    • /
    • 2015
  • Laser-gas metal arc hybrid welding has been considered as an alternative process of gas metal arc welding for offshore pipe laying. Fiber delivered high power lasers which enable deep penetration welding were recently developed but high power welding characteristics were not fully understood yet. In this study, the influence of shielding gas composition on welding phenomena in high power laser welding was investigated. Bead shapes, melt ejection and dropping were observed after autogenous laser welding with 100% Ar, Ar-20% $CO_2$, Ar-50% $CO_2$, and 100% $CO_2$ shielding gas. Process parameter window was widest with Ar-50% $CO_2$ shielding gas and the penetration was deepest with 100% $CO_2$ shielding gas. The melt dropping was not observed when Ar-50% $CO_2$ or 100% $CO_2$ shielding gas was supplied.

전방과 측면 방사 조절이 가능한 의료용 광섬유 팁 가공 기술 (Laser Microfabrication of Multidirectional Side-fire Optical Fiber Tip)

  • 정덕;손익부;노영철;김진혁;김창환;이호
    • 한국정밀공학회지
    • /
    • 제30권10호
    • /
    • pp.1017-1022
    • /
    • 2013
  • Currently, various optical fiber tips are used to deliver laser beam for endoscopic surgery. In this paper, we demonstrated multidirectional (forward and side) firing optical fiber tip using a femtosecond micromachining and $CO_2$ laser polishing technology. We controlled the edge width of optical fiber tip, by modulating the condition of $CO_2$ laser, to regulate the amount of side and forward emission. The distal end of the optical fiber with core/clad diameter of $400/440{\mu}m$ was microstructured with cone shape by using a femtosecond laser. And then the microstructured optical fiber tip was polished by $CO_2$ laser beam result in smoothing and specular reflection at the surface of the cone structure. Finally, we operated the LightTools simulation and good agreement was generally found between the proposed model and experimental simulation.