• 제목/요약/키워드: CO(Carbon monoxide)

검색결과 574건 처리시간 0.025초

중.저온형 고체산화물 연료전지에서 연료로 공급되는 CO 와 H2 가 성능에 미치는 영향 (Performance Behavior by H2 and CO as a Fuel in Intermediate Temperature Solid Oxide Fuel Cell (IT-SOFC))

  • 박광진;배중면
    • 대한기계학회논문집B
    • /
    • 제32권12호
    • /
    • pp.963-969
    • /
    • 2008
  • The performance behavior of solid oxide fuel cell using $H_2$ and CO as fuels was investigated. The power densities and impedance results showed a little variation as the ratio of $H_2$ and CO changed. However, when the pure CO was used as a fuel, area specific resistance (ASR), especially low frequency region, was increased. This might be due to carbon deposition on anode. The maximum power density was 60% lower using CO than using $H_2$. Carbon deposition reduced after constant current was applied. The SOFC performance was recovered from the carbon deposition after applying constant current during 100h.

이산화탄소와 알코올류의 혼합물에 대한 방사선 분해반응에 관한 연구 (Gamma-Radiolysis of Carbon Dioxide (V). Radiolysis of Carbon Dioxide-Alcohol Mixtures)

  • 최상업;변형직;진준하
    • 대한화학회지
    • /
    • 제35권1호
    • /
    • pp.3-15
    • /
    • 1991
  • 10 torr의 기체 iso-프로필알코올과 0∼1990 torr의 이산화탄소의 혼합기체에 0∼50 kGy의 Co-60감마선을 조사한 후 생성물을 기체크로마토그래프로 분석하여 일산화탄소, 아세톤, 메탄, 에탄, C$_3$H$_a$, C$_4$H$_b$ 및 tert-부틸알코올 등이 생성됨을 알았다. 490 torr 이상의 이산화탄소가 혼합된 시료에서는 G(CO)값 약 4를 얻었다. 아세톤 등 각 유기생성물의 생성속도와 iso-프로필알코올의 분해속도는 이산화탄소의 압력에 비례하여 증가되었는데, 이산화탄소 압력 10 torr 증가당 G-(-iso-Propanol)값은 4, G(Acetone)값은 2씩 증가되었다. 본 실험의 결과를 토대로 iso-프로필알코올과 이산화탄소 혼합기체에서의 방서선에 의한 일산화탄소와 각종 유기물의 생성반응 및 iso-프로필알코올의 분해반응 메카니즘을 고찰하였다.

  • PDF

가스보일러 CO중독 위험성 예측 및 근원적 예방기술 개발 (The Risk Assessment of Carbon Monoxide Poisoning by Gas Boiler Exhaust System and Development of Fundamental Preventive Technology)

  • 박찬일;류기윤
    • 한국가스학회지
    • /
    • 제25권3호
    • /
    • pp.27-38
    • /
    • 2021
  • 본 연구에서는 가스보일러 가동 중 배기통이 이탈하는 상황이 발생했을 때, 시스템적으로 인지하고 자동으로 보일러 가동을 중지하여 일산화탄소를 포함한 유해 배기가스가 실내로 유입되는 상황을 근원적으로 차단하는 방안을 제시하였다: (1) 연소에 필요한 공기량을 제어하기 위해 설치된 풍압센서(APS : Air Pressure Sensor)의 출력전압을 측정하여 배기통의 정상상태와 이탈상태를 감시하는 기능을 추가한다. (2) 배기통이 이탈하면 APS의 출력전압이 상시 운전범위에서 일시적으로 상승하게 된다. 보일러 제어부인 PCB가 이 상태를 배기통 이탈로 간주하여 보일러 가동을 멈추면서 배기통 이탈 상태를 실내온도 조절기에 표시하도록 한다. 또한 국토교통부령으로 정한 「건축물의 설비기준 등에 관한 규칙」에서 명시한 공동주택 및 다중이용시설의 환기시설 기준에 따라, 실내공기 교환횟수에 맞는 풍량을 적용하여 실내공기를 환기하는 실험을 실시하였다. 이 실험 결과 실제 일산화탄소가 실내에 누출된 최악의 상태에서, 중독사고 예방이 가능하다는 것을 확인하였다. 다만, 동 규칙에서 정의한 시간당 실내공기 교환횟수를 기존 0.7회에서 0.5회로 2013년부터 완화하여 운영하고 있는데, 실험결과 8시간 가중평균 노출기준인 TWA 30 ppm을 초과하는 농도가 측정되어 기준을 강화할 필요성이 있다. 본 연구 결과에 기초하여 가스보일러 배기압력의 기계적 인지를 통해 배기통 이탈을 감지하는 기술과 일산화탄소 경보기와 연동된 실내공기 환기시스템 기술을 도입한다면 일산화탄소 중독사고가 크게 감소될 것으로 판단된다. 제조 및 검사단계의 문제점을 보완하고, 올바른 설치 및 수리, 사용자의 배기통 이탈에 대한 관심이 더해졌을 때, 일산화탄소 중독으로 인한 인명사고를 예방하는데 효과적인 대책이 될 것으로 사료된다.

목재 펠릿(pellet)을 활용하는 휴대용 펠릿 난로의 연소 효율 향상과 일산화탄소(CO) 배출 저감을 위한 연소기 개발 (Development of a Combustor in Portable Pellet Stoves Using Wood Pellets to Improve Combustion Efficiency and to Reduce Carbon Monoxide (CO) Emission)

  • 민경순;임대은
    • 대한토목학회논문집
    • /
    • 제40권3호
    • /
    • pp.315-320
    • /
    • 2020
  • 목재 부산물 등을 활용하여 제조되는 목재펠릿(pellet)은 가공되는 방식과 추가되는 부산물의 종류, 목재펠릿난로의 종류에 따라 완전연소가 아닌 불완전연소가 일어나는 경우가 있다. 이에 본 연구에서는 불완전연소로 인한 환경오염과 에너지 낭비를 줄이기 위해 목재펠릿난로 연소 작용의 핵심부인 연소기를 개발하였다. 현재 시중에서 유통되고 있는 목재펠릿난로의 연소 작용을 담당하고 있는 연소기의 한계점을 넘기 위해 다층구조(Multi Layer)방식이라 명명하는 새로운 구조의 연소기 방식을 창안하고, CAD (Computer Aided Design) program으로 설계 후 3D 프린터를 활용하여 실현 가능성을 검증하였다. 검증된 데이터를 바탕으로 다층구조(Mulit Layer)방식의 목재펠릿난로의 연소 작용을 담당하는 연소기의 시제품(Prototype)을 설계, 제작하여 실험을 진행하였다. 실험의 신뢰도를 위해 동일한 날짜, 장소, 연료를 사용하여 현재 시중에서 유통되어 판매되고 있는 목재펠릿난로의 연소기와 본 연구에서 개발한 목재펠릿난로의 연소기를 비교실험하였다. 실험의 결과로 환경적인 측면에서 일산화탄소(Carbon Monoxide) 배출량의 감소를 확인하였고, 에너지 효율면에서 상대적으로 높은 열효율 결과를 도출하여 긍정적인 결과를 나타냈다.

코로나바이러스감염증-19 대유행 이후 응급실로 내원한 급성 일산화탄소 중독 환자의 특성 변화 (Changes in the characteristics of acute carbon monoxide poisoning patients who visited the emergency department during the COVID-19 pandemic)

  • 심준보;안태규;김현
    • 대한임상독성학회지
    • /
    • 제21권2호
    • /
    • pp.108-116
    • /
    • 2023
  • Purpose: This study investigated the differences between patients with acute carbon monoxide (CO) poisoning who visited the emergency department (ED) before and during the coronavirus disease 2019 (COVID-19) pandemic. Methods: This was a single-center retrospective observational study. Patients with CO poisoning who visited the ED during the period from February 2020 to January 2023 were classified as the COVID-19 pandemic group, and those from February 2019 to January 2020 were classified as the non-pandemic group. Patients' medical records were reviewed, their demographic and clinical characteristics were compared, and the length of stay in ED was checked. The time from admission to the ED to the start of hyperbaric oxygenation (HBO) was defined as the door-to-HBO time, and this parameter was compared between both groups. Results: In total, 672 patients were included in this study. The proportion of intentional poisoning was significantly higher in the COVID-19 pandemic group than in the non-pandemic group (p=0.028). The proportion of intentional poisoning significantly increased in the 20- to 29-year-old age group during the COVID-19 pandemic (p<0.001). In addition, it took longer to initiate HBO in the COVID-19 pandemic group than in the non-pandemic group (p=0.001). Conclusion: These findings suggest that pandemics of infectious diseases, such as COVID-19, increase the proportion of intentional CO poisoning, and it may take longer to initiate HBO after visiting the ED. Efforts will be needed to decrease intentional CO poisoning and length of stay in ED.

CO concentration distribution in a tunnel model closed at left end side using CFD

  • Peng, Lu;Lee, Yong-Ho
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제37권3호
    • /
    • pp.282-290
    • /
    • 2013
  • A primary air pollutant as an indicator of air quality released from incomplete combustion is Carbon monoxide. A study of the distributions of CO concentration with no heat source in a tunnel model closed at left end side is simulated with a commercial CFD code. The tunnel model is used to investigate the CO concentration distributions at three Reynolds numbers of 990, 1970, and 3290. which are computed by the inlet velocities of 0.3, 0.6 and 1.0 m/s. The CFD predictive approaches can be useful for a better design to analyze the distributions of CO concentrations. In the case of the tunnel model closed at left end side alone, the concentration changes of x/H=-5 and -2.5 have the similar laminar characteristics like the case of the tunnel model closed at both end sides expecially at low values of Reynolds number. Irregular average CO concentration variations at Re=1790 are considered that the transition from laminar to turbulent flow occurs even in three different tunnel models.

Pseudomonas carboxydovorans와 Acinetobacter sp.1의 일산화탄소 산화효소의 세포내 분포에 대한 효소학적 연구 (Enzymological Localization of Carbon Monoxide Dehydrogenases in Pseudomonas carboxydovorans and Acinetobacter sp.1)

  • 김시욱;김영민
    • 미생물학회지
    • /
    • 제24권3호
    • /
    • pp.270-275
    • /
    • 1986
  • Pseudomonas carboxydovorans와 Acinetobacter sp.l에 존재하는 일산화탄소 산화효소의 세포내 분포양상을 조사 하기 위 하여 엘 산 화탄소를 이 용하여 성장한 세균을 초음파로 파괴하거나 세균의 spheroplast을 만들어 삼투 충격으로 파괴한 후 soluble fraction과 particulate fraction에서의 일산화탄소 산화효소의 환성분포를 조사허여 비교하였다. 세균을 초음파로 파괴하였을 때는 crude cell extract에 존재하면 효소환성의 대부분이 soluble fracttion에서 검출되었다. 그러나 sphe roplas를 삼투충격으로 파괴하였을 때는 효소활성 이 세포막부분에서만 나타났다. 이와 같은 결과는 이 세균들의 일산화탄소 산화효소가 세포막에 느슨하게 붙이 있음을 시사하고 있다.

  • PDF

Control over [2+2+2] and Carbonylative [4+2] Cycloaddition by CO Pressure in Co-Catalyzed Cycloaddition between Internal Diynes and Cyclopentadiene

  • Kim, Do-Han;Chung, Young-Keun;Han, Jin-Wook
    • Bulletin of the Korean Chemical Society
    • /
    • 제29권6호
    • /
    • pp.1224-1228
    • /
    • 2008
  • The reaction of internal diynes and cyclopentadiene in the presence of 5 mol % of cobalt catalysts proceeded under 5 atm of carbon monoxide pressure to give a high yield of the corresponding [2+2+2] cycloaddition product. By lowering carbon monoxide pressure from 30 atm to 5atm, cyclopentadiene can be used as a dienophile in the cobalt carbonyl-catalyzed [2+2+2] cycloaddition reaction between internal diynes and cyclopentadiene.

Heme Oxygenase-1 : Its Therapeutic Roles in Inflammatory Diseases

  • Pae, Hyun-Ock;Chung, Hun-Taeg
    • IMMUNE NETWORK
    • /
    • 제9권1호
    • /
    • pp.12-19
    • /
    • 2009
  • Heme oxygenase (HO)-1 is an inducible enzyme that catalyzes the first and rate-limiting step in the oxidative degradation of free heme into ferrous iron, carbon monoxide (CO), and biliverdin (BV), the latter being subsequently converted into bilirubin (BR). HO-1, once expressed during inflammation, forms high concentrations of its enzymatic by-products that can influence various biological events, and this expression is proven to be associated with the resolution of inflammation. The degradation of heme by HO-1 itself, the signaling actions of CO, the antioxidant properties of BV/BR, and the sequestration of ferrous iron by ferritin all concertedly contribute to the anti-inflammatory effects of HO-1. This review focuses on the anti-inflammatory mechanisms of HO-1 actions and its roles in inflammatory diseases.

A Carbon Monoxide Poisoning Case in Which Hyperbaric Oxygen Therapy Was Not Possible Due to Iatrogenic Pneumothorax after Unnecessary Central Catheterization

  • Kim, Hyung Il;Oh, Seong Beom
    • Journal of Trauma and Injury
    • /
    • 제32권4호
    • /
    • pp.252-257
    • /
    • 2019
  • Hyperbaric oxygen therapy (HBOT) is used to treat carbon monoxide (CO) poisoning. However, untreated pneumothorax is an absolute contraindication for HBOT. More caution is needed with regard to monoplace hyperbaric chambers, as patient monitoring and life-saving procedures are impossible inside these chambers. Central catheterization is frequently used for various conditions, but unnecessary catheterization must be avoided because of the risk of infection and mechanical complications. Herein, we describe a case of CO poisoning in which iatrogenic pneumothorax developed after unnecessary subclavian central catheterization. The patient did not need to be catheterized, and HBOT could not be performed because of the pneumothorax. Hence, this case reminds us of basic-but nonetheless important-principles of catheterization.