• Title/Summary/Keyword: CMR materials

Search Result 55, Processing Time 0.03 seconds

Impact of Cyano and Fluorine Group Functionalization on the Optoelectronic and Photovoltaic Properties of Donor-Acceptor-π-Acceptor Benzothiadiazole Derived Small Molecules: A DFT and TD-DFT Study

  • Prabhat Gautam;Anurag Gautam;Neeraj Kumar
    • Korean Journal of Materials Research
    • /
    • v.33 no.6
    • /
    • pp.236-241
    • /
    • 2023
  • Solar cells based on p-conjugated donor-acceptor (D-A) organic molecular systems are a promising alternative to conventional electrical energy generation. D-A molecular systems, which have a triphenylamine (TPA) moiety linked with a benzothiadiazole (BTD) moiety, open the potential development of new small molecule donors for bulk heterojunction (BHJ) solar cells. Here, a series of donor-acceptor-π-acceptor (D-A-π-A) small molecule donors (SMD) derived from triphenylamine (TPA) donor and benzothiadiazole (BTD) acceptor building blocks, were designed for BHJ organic solar cells. The small molecule donors SMD1-4 were studied using density functional theory (DFT) and time dependent-DFT (TDDFT) methods, to understand the effect of cyano and fluorine group functionalization on their properties. The effect of structure alteration by cyano and fluorine group functionalization on the optoelectronic properties, the calculated highest occupied molecular orbitals (HOMOs) and lowest unoccupied molecular orbitals (LUMOs) and the HOMO-LUMO gaps were theoretically explored. The Voc (open-circuit photovoltage) and fill factor (FF) for SMD1-4 were obtained with a PC71BM acceptor, which showed that these organic small molecules are potential small molecule donors for organic bulk heterojunction solar cells.

Ultraviolet Photoelectron spectroscopy Study of Colossal Magnetoresistive $La_{0.7-x}P_rxCa_{0.3}MnO_3$

  • Lee, Chang-Won;Hoon Koh;Noh, Han-Jin;Park, Jong-Hyurk;Kim, Hyung-Do;Moonsup Han;Oh, Se-Jung;Eom, dai-Jin;Noh, Tae-Won
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1999.07a
    • /
    • pp.172-172
    • /
    • 1999
  • Perovskite Manganese Oxide has been intensively investigated since the discovery of the colossal magnetoresistive(CMR) effect. In this paper, we studied the effect of temperature dependence and various doping dependence of rare earth site ions of La0.7-xPrxCa0.3MnO3 series using Ultraviolet Photoelectron spectroscopy(UPS). They show unusual temperature dependent features and the doped rare earth ions seem to affect the electron-phonon coupling strongly. We found clear evidence of metal-insulator transition from the spectral density at the Fermi level. but the transition temperature is lower than that deduced from transport measurements. Also we found that the spectral features change as time goes on implying that the surface of these materials is somewhat unstable in the vacuum. We can conclude from these results that the surface oxygen atoms correlated to the hopping electrons can escape from the material into the vacuum and that the surface state of these material is different from the bulk state.

  • PDF

Magnetic and transport properties of $La_{0.8}Sr_{0.2}MnO_3/La_{0.8}Ca_{0.2}MnO_3$ bilayer

  • Li, S.F.;Kim, J.B.;Hyun, Y.H.;Lee, Y.P.;Prokhorov, V.G.;Komashko, V.A.
    • Journal of Korean Vacuum Science & Technology
    • /
    • v.7 no.1
    • /
    • pp.8-12
    • /
    • 2003
  • The effects of lattice strain on the magnetic and the transport properties of La$_{0.8}$Sr$_{0.2}$MnO$_3$films grown on a LaAlO$_3$ (001) substrate and on a La$_{0.8}$Sr$_{0.2}$MnO$_3$ layer have been studied. It was observed that the metal-insulator and the ferromagnetic transitions turn out to be at higher temperatures for the film deposited on La$_{0.8}$Sr$_{0.2}$MnO$_3$ layer with respect to that on LaAlO$_3$. The dependence of Curie temperature on the bulk and the Jahn-Teller strains has also been determined. determined.

  • PDF

Automated Measurement of Native T1 and Extracellular Volume Fraction in Cardiac Magnetic Resonance Imaging Using a Commercially Available Deep Learning Algorithm

  • Suyon Chang;Kyunghwa Han;Suji Lee;Young Joong Yang;Pan Ki Kim;Byoung Wook Choi;Young Joo Suh
    • Korean Journal of Radiology
    • /
    • v.23 no.12
    • /
    • pp.1251-1259
    • /
    • 2022
  • Objective: T1 mapping provides valuable information regarding cardiomyopathies. Manual drawing is time consuming and prone to subjective errors. Therefore, this study aimed to test a DL algorithm for the automated measurement of native T1 and extracellular volume (ECV) fractions in cardiac magnetic resonance (CMR) imaging with a temporally separated dataset. Materials and Methods: CMR images obtained for 95 participants (mean age ± standard deviation, 54.5 ± 15.2 years), including 36 left ventricular hypertrophy (12 hypertrophic cardiomyopathy, 12 Fabry disease, and 12 amyloidosis), 32 dilated cardiomyopathy, and 27 healthy volunteers, were included. A commercial deep learning (DL) algorithm based on 2D U-net (Myomics-T1 software, version 1.0.0) was used for the automated analysis of T1 maps. Four radiologists, as study readers, performed manual analysis. The reference standard was the consensus result of the manual analysis by two additional expert readers. The segmentation performance of the DL algorithm and the correlation and agreement between the automated measurement and the reference standard were assessed. Interobserver agreement among the four radiologists was analyzed. Results: DL successfully segmented the myocardium in 99.3% of slices in the native T1 map and 89.8% of slices in the post-T1 map with Dice similarity coefficients of 0.86 ± 0.05 and 0.74 ± 0.17, respectively. Native T1 and ECV showed strong correlation and agreement between DL and the reference: for T1, r = 0.967 (95% confidence interval [CI], 0.951-0.978) and bias of 9.5 msec (95% limits of agreement [LOA], -23.6-42.6 msec); for ECV, r = 0.987 (95% CI, 0.980-0.991) and bias of 0.7% (95% LOA, -2.8%-4.2%) on per-subject basis. Agreements between DL and each of the four radiologists were excellent (intraclass correlation coefficient [ICC] of 0.98-0.99 for both native T1 and ECV), comparable to the pairwise agreement between the radiologists (ICC of 0.97-1.00 and 0.99-1.00 for native T1 and ECV, respectively). Conclusion: The DL algorithm allowed automated T1 and ECV measurements comparable to those of radiologists.

Regional Amyloid Burden Differences Evaluated Using Quantitative Cardiac MRI in Patients with Cardiac Amyloidosis

  • Jin Young Kim;Yoo Jin Hong;Kyunghwa Han;Hye-Jeong Lee;Jin Hur;Young Jin Kim;Byoung Wook Choi
    • Korean Journal of Radiology
    • /
    • v.22 no.6
    • /
    • pp.880-889
    • /
    • 2021
  • Objective: This study aimed to investigate the regional amyloid burden and myocardial deformation using T1 mapping and strain values in patients with cardiac amyloidosis (CA) according to late gadolinium enhancement (LGE) patterns. Materials and Methods: Forty patients with CA were divided into 2 groups per LGE pattern, and 15 healthy subjects were enrolled. Global and regional native T1 and T2 mapping, extracellular volume (ECV), and cardiac magnetic resonance (CMR)-feature tracking strain values were compared in an intergroup and interregional manner. Results: Of the patients with CA, 32 had diffuse global LGE (group 2), and 8 had focal patchy or no LGE (group 1). Global native T1, T2, and ECV were significantly higher in groups 1 and 2 than in the control group (native T1: 1384.4 ms vs. 1466.8 ms vs. 1230.5 ms; T2: 53.8 ms vs. 54.2 ms vs. 48.9 ms; and ECV: 36.9% vs. 51.4% vs. 26.0%, respectively; all, p < 0.001). Basal ECV (53.7%) was significantly higher than the mid and apical ECVs (50.1% and 50.0%, respectively; p < 0.001) in group 2. Basal and mid peak radial strains (PRSs) and peak circumferential strains (PCSs) were significantly lower than the apical PRS and PCS, respectively (PRS, 15.6% vs. 16.7% vs. 26.9%; and PCS, -9.7% vs. -10.9% vs. -15.0%; all, p < 0.001). Basal ECV and basal strain (2-dimensional PRS) in group 2 showed a significant negative correlation (r = -0.623, p < 0.001). Group 1 showed no regional ECV differences (basal, 37.0%; mid, 35.9%; and apical, 38.3%; p = 0.184). Conclusion: Quantitative T1 mapping parameters such as native T1 and ECV may help diagnose early CA. ECV, in particular, can reflect regional differences in the amyloid deposition in patients with advanced CA, and increased basal ECV is related to decreased basal strain. Therefore, quantitative CMR parameters may help diagnose CA and determine its severity in patients with or without LGE.

The Extent of Late Gadolinium Enhancement Can Predict Adverse Cardiac Outcomes in Patients with Non-Ischemic Cardiomyopathy with Reduced Left Ventricular Ejection Fraction: A Prospective Observational Study

  • Eun Kyoung Kim;Ga Yeon Lee;Shin Yi Jang;Sung-A Chang;Sung Mok Kim;Sung-Ji Park;Jin-Oh Choi;Seung Woo Park;Yeon Hyeon Choe;Sang-Chol Lee;Jae K. Oh
    • Korean Journal of Radiology
    • /
    • v.22 no.3
    • /
    • pp.324-333
    • /
    • 2021
  • Objective: The clinical course of an individual patient with heart failure is unpredictable with left ventricle ejection fraction (LVEF) only. We aimed to evaluate the prognostic value of cardiac magnetic resonance (CMR)-derived myocardial fibrosis extent and to determine the cutoff value for event-free survival in patients with non-ischemic cardiomyopathy (NICM) who had severely reduced LVEF. Materials and Methods: Our prospective cohort study included 78 NICM patients with significantly reduced LV systolic function (LVEF < 35%). CMR images were analyzed for the presence and extent of late gadolinium enhancement (LGE). The primary outcome was major adverse cardiac events (MACEs), defined as a composite of cardiac death, heart transplantation, implantable cardioverter-defibrillator discharge for major arrhythmia, and hospitalization for congestive heart failure within 5 years after enrollment. Results: A total of 80.8% (n = 63) of enrolled patients had LGE, with the median LVEF of 25.4% (19.8-32.4%). The extent of myocardial scarring was significantly higher in patients who experienced MACE than in those without any cardiac events (22.0 [5.5-46.1] %LV vs. 6.7 [0-17.1] %LV, respectively, p = 0.008). During follow-up, 51.4% of patients with LGE ≥ 12.0 %LV experienced MACE, along with 20.9% of those with LGE ≤ 12.0 %LV (log-rank p = 0.001). According to multivariate analysis, LGE extent more than 12.0 %LV was independently associated with MACE (adjusted hazard ratio, 6.71; 95% confidence interval, 2.54-17.74; p < 0.001). Conclusion: In NICM patients with significantly reduced LV systolic function, the extent of LGE is a strong predictor for long-term adverse cardiac outcomes. Event-free survival was well discriminated with an LGE cutoff value of 12.0 %LV in these patients.

Fabrication of $Sr_2FeMoO_6$ thin films by RF Sputtering (RF 스퍼터법에 의한 $Sr_2FeMoO_6$ 박막 제조)

  • Ryu, Hee-Uk;Sun, Ho-Jun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.24-24
    • /
    • 2010
  • 대형구조물의 구조안정성 진단, 로봇과 같은 지능기계의 제어, 환경오염을 감지하기 위한 센서의 중요성은 날로 증대되고 있다. 이러한 센서의 감도와 성능을 높이기 위해서 소형화, 다기능화, 집적화가 요구되고 있는데, 고성능 센서소자들의 집적화를 위해서 기존에 적용된 벌크형태의 재료들을 박막화하여 다층적층 및 소형화할 필요가 있다. 집적화 센서의 구현에 있어서 전극박막은 센서의 특성을 좌우하는 중요한 역할을 한다. 일반적으로 금속박막이 전극으로 사용되고 있으나 열적 불안정성 및 박리현상의 문제점을 지니고 있다. 따라서 이를 해결하기 위해 전도성산화막을 전극으로 적용하고자하는 연구가 요구되고 있다. 전도성산화막을 전극으로 적용하면 센서소자의 성능이 개선되는 경향이 있다. $Sr_2FeMoO_6$(SFMO) 산화물은 자기장을 인가했을 때 저항이 감소하는 CMR(colossal magnetoresistance) 물질이며 상온비저항이 낮은 것으로 알려져 있다. 이중 페롭스카이트 (double perovskite) 구조를 갖는 $Sr_2FeMoO_6$ 박막은 센서소자의 전극으로 적용 가능할 것으로 생각되어 박막을 제조하고자 하였으며 미세구조와 전기전도 특성을 조사하였다. 박막제조를 위해서는 RF 스퍼터법을 사용하였다. 스퍼터를 위한 타겟은 고상반응법으로 분말타겟을 제조하였다. Ar/$O_2$ 가스 유랑변화, 압력변화, 기판 온도변화가 박막의 상형성 등 박막특성에 미치는 영향을 조사하였다. 기판으로는 $SiO_2$(100nm)/Si 기판을 사용하였다. 증착직후에는 비정질막이 얻어졌으며 SFMO 상을 만들기 위해서는 후열처리가 필요하였는데, 환원성 가스 분위기 [$H_2$(5%)/Ar] 에서 열처리 조건을 최적화하여 이중 페롭스카이트 구조의 단일상 박막을 제조할 수 있었다. SFMO 단일상 박막은 증착시에나 후열처리 시 산소의 억제가 중요함을 알 수 있었다.

  • PDF

Semi-Quantitative Scoring of Late Gadolinium Enhancement of the Left Ventricle in Patients with Ischemic Cardiomyopathy: Improving Interobserver Reliability and Agreement Using Consensus Guidance from the Asian Society of Cardiovascular Imaging-Practical Tutorial (ASCI-PT) 2020

  • Cherry Kim;Chul Hwan Park;Do Yeon Kim;Jaehyung Cha;Bae Young Lee;Chan Ho Park;Eun-Ju Kang;Hyun Jung Koo;Kakuya Kitagawa;Min Jae Cha;Rungroj Krittayaphong;Sang Il Choi;Sanjaya Viswamitra;Sung Min Ko;Sung Mok Kim;Sung Ho Hwang;Nguyen Ngoc Trang;Whal Lee;Young Jin Kim;Jongmin Lee;Dong Hyun Yang
    • Korean Journal of Radiology
    • /
    • v.23 no.3
    • /
    • pp.298-307
    • /
    • 2022
  • Objective: This study aimed to evaluate the effect of implementing the consensus statement from the Asian Society of Cardiovascular Imaging-Practical Tutorial 2020 (ASCI-PT 2020) on the reliability of cardiac MR with late gadolinium enhancement (CMR-LGE) myocardial viability scoring between observers in the context of ischemic cardiomyopathy. Materials and Methods: A total of 17 cardiovascular imaging experts from five different countries evaluated CMR obtained in 26 patients (male:female, 23:3; median age [interquartile range], 55.5 years [50-61.8]) with ischemic cardiomyopathy. For LGE scoring, based on the 17 segments, the extent of LGE in each segment was graded using a five-point scoring system ranging from 0 to 4 before and after exposure according to the consensus statement. All scoring was performed via web-based review. Scores for slices, vascular territories, and total scores were obtained as the sum of the relevant segmental scores. Interobserver reliability for segment scores was assessed using Fleiss' kappa, while the intraclass correlation coefficient (ICC) was used for slice score, vascular territory score, and total score. Inter-observer agreement was assessed using the limits of agreement from the mean (LoA). Results: Interobserver reliability (Fleiss' kappa) in each segment ranged 0.242-0.662 before the consensus and increased to 0.301-0.774 after the consensus. The interobserver reliability (ICC) for each slice, each vascular territory, and total score increased after the consensus (slice, 0.728-0.805 and 0.849-0.884; vascular territory, 0.756-0.902 and 0.852-0.941; total score, 0.847 and 0.913, before and after implementing the consensus statement, respectively. Interobserver agreement in scoring also improved with the implementation of the consensus for all slices, vascular territories, and total score. The LoA for the total score narrowed from ± 10.36 points to ± 7.12 points. Conclusion: The interobserver reliability and agreement for CMR-LGE scoring for ischemic cardiomyopathy improved when following guidance from the ASCI-PT 2020 consensus statement.

Preparation and Characterization of La0.8Ca0.2MnO3 (La0.8Ca0.2MnO3의 합성 및 특성연구)

  • 정미원;이지윤;김현정
    • Journal of the Korean Ceramic Society
    • /
    • v.40 no.5
    • /
    • pp.434-440
    • /
    • 2003
  • The powders of L $a_{0.8}$C $a_{0.2}$Mn $O_3$ Colossal Magnetoresistance (CMR) materials were synthesized by sol-gel process. Lanthanum(H), Calcium(II) and Manganese(III) 2,4-Pentanedionate were dissolved in a mixed binary solution consisted of propionic acid and methanol with PEG (15 wt%) aqueous solution. The progress of reactions was monitored by FT-IR spectroscopy. The Lao scao.2Mn03 gel powders were annealed at various temperatures. The structural changes were investigated by FT-IR, CP/MAS $^{ 13}$C solid state NMR spectroscopy and XRD. The thermochemical property, particle characterization, microstructure of sintered sample, and cation composition of gel powder were studied by TG/DTA, FE-SEM and ICP-AES. The magnetic characterizations were identified through measurement of magnetic moment by VSM.

Characteristics of $La_{0.7}{Ca_{0.3}}{MnO_3}$Powders Prepared by Solution Combustion Method and Solid State Reaction Method for CMR Applications (용액연소법과 고상반응법으로 제조된 CMR용 $La_{0.7}{Ca_{0.3}}{MnO_3}$분말 특성)

  • Lee, Kang-Ryeol;Song, Jae-Sung;Park, Sung
    • Journal of the Korean Ceramic Society
    • /
    • v.38 no.5
    • /
    • pp.461-465
    • /
    • 2001
  • La$_{0.7}$Ca$_{0.3}$MnO$_3$분말은 공기중에서 하소온도와 시간의 변화에 따라 각각 용액연소법과 고상반응법을 이용하여 제조되었다. 조성 및 구조 특성을 XRD와 SEM으로부터 조사하였으며 소결성은 dilatometer에 의해 조사되었다. 또한 분말 특성은 BET에 의해 조사되었고 분말의 하소온도는 TG 분석으로부터 결정되었다. 하소온도 및 시간이 증가함에 따라 La$_{0.7}$Ca$_{0.3}$MnO$_3$상의 XRD peak가 증가하였는데, 고상반응법을 이용한 경우 100$0^{\circ}C$에서 24시간 동안 하소해서야 겨우 La$_{0.7}$Ca$_{0.3}$MnO$_3$의 단상을 얻을 수 있었으나 용액연소법을 이용한 경우, $650^{\circ}C$에서 30분 동안 하소함으로써 submicron 입자크기를 갖는 단상이면서 초미세한 La$_{0.7}$Ca$_{0.3}$MnO$_3$분말을 쉽게 얻을 수 있었다. 또한 용액연소법에 의해 제조된 다결정인 La$_{0.7}$Ca$_{0.3}$MnO$_3$분말은 49.44$m^2$/g 정도의 매우 큰 비표면적을 얻을 수 있었다. 이 값은 고상반응법에 의해 제조된 분말의 비표면적 보다 매우 컸으며 이와 같으 사실로 인해 용액연소법에 의해 제조된 분말의 소결온도를 낮출 수 있었다. 분말의 소결온도를 낮출 수 있었다.

  • PDF