• Title/Summary/Keyword: CMF design

Search Result 17, Processing Time 0.022 seconds

Steady-State and Transient Performance Simulation of a Turboshaft Engine with a Free Power Turbine

  • King, Chang-Duk;Chung, Suk-Choo
    • Journal of Mechanical Science and Technology
    • /
    • v.14 no.11
    • /
    • pp.1296-1304
    • /
    • 2000
  • A program of steady-state and transient performance analysis for a 200kW-class small turboshaft engine with free power turbine was developed. An existing turbojet engine was used for the gas generator of the developed turboshaft engine, which was modified to satisfy performance requirements of this turboshaft engine. To verify the accuracy of steady-state performance program for this engine: the program was applied to the gas turbine test unit of the same type, and the analysis results were compared with experimental results. The developed transient performance analysis program using the CMF (Constant Mass Flow) method was utilized to analyze the cases of step increase and ramp increase of the fuel.

  • PDF

A study on the application of sports wheelchair materials based on emotional materials (감성 소재 기반의 스포츠 휠체어 소재 적용에 관한 연구)

  • Song, Sung-il
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.31 no.1
    • /
    • pp.43-54
    • /
    • 2021
  • This work proposes a process to derive elements of emotional materials based on trend research in the application of materials in product development. It was intended to be applied to the development of a case model, a Korean sports wheelchair, and focused on the material portion of CMF-based research. Through research methodologies such as megatrends, competitor product and part-by-part analysis, and psychological color analysis, we studied optimization, verification, and DBization of materials, and drew the final application plan through FGI verification.

Feasibility Study on Removal of Total Suspended Solid in Wastewater with Compressed Media Filter (압축성 여재 여과를 이용한 하수의 고형물질 제거 타당성 연구)

  • Kim, Yeseul;Jung, Chanil;Oh, Jeill;Yoon, Yeomin
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.2
    • /
    • pp.84-95
    • /
    • 2014
  • Recently, as a variety of techniques of CMF (Compressed media filter) that has advantages of high porosity and compressibility have been developed in the U.S. and Japan. Therefore, the interest of intensive wastewater treatment using CMF has grown. This study examined the feasibility of CMF with varying sewage water quality to determine the optimum operating conditions. A preliminary tracer test that investigated the filtering process under various compression and flow rate conditions was performed. In a high compression condition, different porosities were applied to each depth of the column. Therefore, a distinct difference between a theoretical value and results of tracer test was observed. For the TSS (Total suspended solid) removal and particle size distribution of CMF for pre-treatment water under the various compression conditions, the compression ratio of 30 percent as the optimal condition showed greater than 70% removal efficiency. In addition, the compression ratio of >15% was required to remove small-sized particles. Also, an additional process such as coagulation is necessary to increase the removal efficiency for < $10{\mu}m$ particles, since these small particles significantly influence the effluent concentration. Modeling results showed that as the compression rate was increased, TSS removal efficiency in accordance with each particle size in the initial filtration was noticeably observed. The modeling results according to the depth of column targeting $10{\mu}m$ particles having the largest percentage in particle size distribution showed that 150-300 mm in filter media layer was the most active with respect to the filtering.

Research about design and manufacture of Crossing High-Amplitude Magneto-Therapy own nerve system for nervous tissue rehalibitation treatment (신경조직 재활치료를 위한Crossing High-Amplitude Magneto-Therapy 자기신경 시스템의 설계 및 제작에 관한 연구)

  • Kim Whi-Young
    • Journal of the Korea Computer Industry Society
    • /
    • v.7 no.3
    • /
    • pp.263-270
    • /
    • 2006
  • Magnetic nerve stimulation treatment is much backward real condition than other field. Specially, successful medical treatment introduction of magnetic field (MF) can was refered long ago in Avicenna's work, and is thought as age of medicine magnetology development recently. These development is achieved through biologist and biophysicist and clinician's joint effort, but, new mountings and relationship air tassel are developed steadily. Magnetic nerve stimulation treatment field designs treatment system by each function during long wave high-amplitude (traditional magneto therapy of greatly great that strong that) short time that CMF, VMF, PMF field etc. are representative but are HPMT technology in this research and manufacture and special quality did comparative analysis.

  • PDF

Safety Review Experience of Computerized Logic System for YGN 3 and 4

  • Yun, Won-Young;Kim, Dae-Il;Koh, Jong-Soo;Kim, Bok-Ryul;Oh, Sung-Hun;Lim, Jang-Hyun
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1995.05a
    • /
    • pp.602-607
    • /
    • 1995
  • This article presents safety review experience of microprocessor-based Interposing Logic System(ILS) of Engineering Safety Feature Actuation System(ESFAS). The ILS is the first application of computerized logic design to safety system in Korean nuclear power plants without verification of the system reliability by proven technology concept. As a result of evaluation for the ILS, Korea Institute of Nuclear Safety(KINS) concluded that the microprocessor-based ILS is not acceptable in some features detailed enough to defend against software common mode failures(CMF). Therefore, we required licensee to install hardwired interlock signal configuration and a Hardwired Backup Panel to control safety-related equipment. We believe that the microprocessor-based ILS with the hardwired backup panel and inter-connection of interlock signal by hardwired configuration will improve the plant safety.

  • PDF

Research about design and manufacture of Crossing High-Amplitude Magneto-Therapy own nerve system for Muscuoskeltal tissue rehalibitation treatment (근조직 재활치료를 위한 자계신경 자극시스템의 설계 및 구현)

  • Kim, Whi-Young
    • Proceedings of the IEEK Conference
    • /
    • 2006.06a
    • /
    • pp.855-856
    • /
    • 2006
  • Magnetic nerve stimulation treatment is much backward real condition than other field. Specially, successful medical treatment introduction of magnetic field (MF) can was refered long ago in Avicenna's work, and is thought as age of medicine magnetology development recently. These development is achieved through biologist and biophysicist and clinician's joint effort, but, new mountings and relationship air tassel are developed steadily. Magnetic nerve stimulation treatment field designs treatment system by each function during long wave high-amplitude (traditional magneto therapy of greatly great that strong that) short time that CMF, VMF, PMF field etc. are representative but are HPMT technology in this research and manufacture and special quality did comparative analysis.

  • PDF

Research about design and manufacture of own nerve system for core formation rehalititation treatment (근조직 재활치료를 위한 자기신경 시스템의 설계 및 제작에 관한 연구)

  • Kim, Whi-Young;Choe, Jin-Yeong;Park, Seong-Jun;Kim, Jin-Yeong;Park, Seong-Jun;Kim, Hui-Je
    • Proceedings of the KIEE Conference
    • /
    • 2006.07d
    • /
    • pp.2171-2172
    • /
    • 2006
  • Magnetic nerve stimulation treatment is much backward real condition than other field. Specially, successful medical treatment introduction of magnetic field (MF) can was refered long ago in Avicenna's work, and is thought as age of medicine magnetology development recently. These development is achieved through biologist and biophysicist and clinician's joint effort, but, new mountings and relationship air tassel are developed steadily. Magnetic nerve stimulation treatment field designs treatment system by each function during long wave high-amplitude (traditional magneto therapy of greatly great that strong that) short time that CMF, VMF, PMF field etc. are representative but are HPMT technology in this research and manufacture and special quality did comparative analysis.

  • PDF