• Title/Summary/Keyword: CM-wire

Search Result 251, Processing Time 0.031 seconds

Amplification Characteristics of Multiple-Wire Corona Preionization type TEA $CO_2$ Laser (다중도선 코로나 선전리형 TEA $CO_2$ 레이저 증폭기의 증폭특성)

  • 임창문
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 1990.02a
    • /
    • pp.59-63
    • /
    • 1990
  • Two-stage TEA(transversely excited atmospheric pressure) CO2 laser amplifier system, Amp I and Amp II are consturcted and their amplification characteristics are investigated theoretically and experimentally. Multiple-wire corona preionization method is used for uniform discharge in laser oscillator and amplifiers. At optimumm gas ratio, CO2 : N2 : He = 1 : 1 : 3, output pulse energy of the oscillator is 0.4J and finally two-stage amplification gives 1.5J output energy which is larger than pumping threshold of para-H2 Raman laser. The rate equations of the amplifiers are solved numerically, and the results are compared with the experimental results. In conclusion, the small signal gain cocfficient of AMP I is 0.025/cm and that of AMP II is 0.02/cm.

  • PDF

An initial investigation of the inverted trussed beam formed by wooden rectangular cross section enlaced with wire rope

  • Gesualdo, F.A.R.;Lima, M.C.V.
    • Structural Engineering and Mechanics
    • /
    • v.44 no.2
    • /
    • pp.239-255
    • /
    • 2012
  • This work presents a contribution to understand the inverted trussed beams behavior. The system has a main beam and struts with rectangular cross section associated to a wire rope enlaced to the main beam. It is an unpublished system with the advantage of easy positioning of the wire rope, once it is a continuous and connected by turnbuckles. It is a system that can be used as support for concrete formworks or for rehabilitation wooden beams proposal. The enlacement of the cable demands a small notch at the top of the cross section and a cross pin at the bottom. Six inverted trussed beams were tested, with spans of 180 cm with cables diameter of 1/4". Additionally, four simple beams without any external steel cable were also tested with material from the same lot of wood, allowing a comparison in rupture. The results showed capacity gain of around 60% compared to a simple beam. Once the wire rope characteristics and anchoring are very important for structure response, some improvement suggestions for the efficiency of the cables are also presented.

Electrophoretic deposition of Bi2223 Superconductor Thick Film (Bi2223 초전도후막의 전기영동전착 특성)

  • Jeon, Yong-Woo;Soh, Dea-Wha;Choi, Sung-Jae;Park, Jung-Cheul
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07a
    • /
    • pp.97-100
    • /
    • 2004
  • In this paper, the preparation of BSCCO superconducting wire by electrophoretic deposition method and the effect of suspension medium used with various solvent solutions of ethanol and buthanol for electrophoretic deposition were studied. The preheating technique in vacuum system for the superconducting powders coated on Ag wire was also investigated. As a result, it was confirmed that the preheating technique was very useful to remove the influence of remains affected to the surface conditions of superconducting wire. And the adsorbed solvent solution which was existed between and on the deposited particle surfaces was almost disappeared at the treating conditions of about $10^{-3}$ Torr and around $200^{\circ}C$ in bell-jar system. By measurement of 4-point prove method, the critical current density($J_c$) of BSCCO superconducting wire was obtained at the value of more than $10^4\;A/cm^2$ in liquid $N_2$(77 K, 0 T).

  • PDF

Performance Verification of Separation Nut Type Non-explosive Separation Device for Cube Satellite Application (큐브위성 적용을 위한 분리너트형 비폭발식 구속분리장치 인증모델의 성능검증)

  • Oh, Hyun-Ung;Lee, Myeong-Jae
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.41 no.10
    • /
    • pp.827-832
    • /
    • 2013
  • Heating wire cutting type separation mechanism has been widely used for cube satellite applications due to its design constraints such as small size of $10cm{\times}10cm{\times}10cm$ and light weight of less than 1kg. In addition, usage of pyro technic device is not allowed for cube satellite application. The conventional methods have some disadvantages of relatively small mechanical constraint force and the system complexity for the multi-deployable systems. In this paper, a separation nut type non-explosive separation mechanism has been proposed and investigated. The effectiveness of the design has been verified through the qualification tests of the mechanism.

Additional axial K-wire Fixation for Proximal Crescentic Metatarsal Osteotomy : A Biomechanical Study (반월형 근위 중족골 절골술에 대한 보강적 축성 K-강선 고정술 : 생체역학적 연구)

  • Jung, Hong-Geun;Kim, You-Jin;Guyton, Gregory
    • Journal of Korean Foot and Ankle Society
    • /
    • v.7 no.2
    • /
    • pp.151-156
    • /
    • 2003
  • Purpose: Proximal crescentic metatarsal osteotomy(PMO) is one of the most common procedures for correcting moderate to severe degree hallux valgus deformity. Although screw fixation is used for osteotomy site stability, loss of reduction can occur. The purpose of this study is to compare the sagittal plane stability of the conventional crescentic PMO fixed with a single screw with that of the crescentic PMO fixed with 1 screw and 2 supplemental K -wires. Material and Methods: Ten matched pairs of cadaveric foot specimens were used for the proximal crescentic metatarsal osteotomy. For one foot specimen of each pair, crescentic osteotomy was fixed with 4mm long threaded cannulated screw, while the matched pair was prepared by adding two axial 1.6mm K-wires to the conventionally fixed 4mm screw. The extensometer was used to measure the osteotomy gap as the metatarsal head was loaded continuously until failure using a servohydraulic MTS Mini Bionix test frame. The strength of fixation was normalized with the bone mineral density (BMD) of the paired specimen $(N{\times}cm^{2}/gm)$, Result: The average strength of the crescentic PMO with axial K-wire fixation ($458.8cm^{2}/gm$, S.D. 434.3) was significantly higher than the standard crescentic PMO ($367.5cm^{2}/gm$, S.D. 397,9) (p=0.05). Conclusion: Supplemental fixation with two axial K-wires can be added to the crescentic PMO to enhance the initial fixation stability to prevent the loss of reduction or dorsal malunion.

  • PDF

Wire-guided Localization Biopsy to Determine Surgical Margin Status in Patients with Non-palpable Suspicious Breast Lesions

  • Dogan, Lutfi;Gulcelik, M. Ali;Yuksel, Murat;Uyar, Osman;Reis, Erhan
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.10
    • /
    • pp.4989-4992
    • /
    • 2012
  • Purpose: Guide-wire localization (GWL) has been a standard technique for many years. Excision of nonpalpable malignant breast lesions with clear surgical margins reduces the risk of undergoing re-excision. The objective of the present study was to evaluate the efficacy of GWL biopsy for assessing surgical margins. Methods: This retrospective study concerned 53 patients who underwent GWL biopsy for non-palpable breast lesions and breast carcinoma diagnosed by histological examination. Age of the patients, tumour size, radiographic findings, breast density specifications, specimen volumes, menopausal status and family history of the patients and surgical margin status were recorded. Results: Median age was 53.3 years, median tumour size was 1.5 cm and median specimen volume was $71.5cm^3$. In fifteen patients (28%) DCIS and in 38 patients (72%) invasive ductal carcinoma was diagnosed. There was positive surgical margins in twenty eight (52.8%) patients. The median distance to the nearest surgical margin was 7.2 mm in clear surgical margins. Younger age and denser breast specifications were found as statistically significant factors for surgical margin status. Median age of the patients who had positive margins was 49.4 years where it was 56.9 years in the patients with negative margins (p=0.04). 79% of the patients with positive margins had type 3-4 pattern breast density according to BIRADS classification as compared to 48% in the patients who had negative margins (p=0.03). Some 38 patients who had positive or close surgical margins received re-excision (72%). Conclusion: Positive margin rates may be higher because of inherent biological differences and diffuse growth patterns in younger patients. There are also technical difficulties that are relevant to denser fibroglandular tissue in placing hooked wire. High re-excision rates must be taken into consideration while performing GWL biopsy in non-palpable breast lesions.

Mechanical Alloying and Combined Process of in-situ and ex-situ to Fabricate the ex-situ C-doped $MgB_2$ Wire (기계적 합금화 및 in-situ와 ex-situ의 혼합공정을 통한 C 도핑된 ex-situ $MgB_2$ 선재 제조)

  • Hwang, Soo-Min;Lee, Chang-Min;Lim, Jun-Hyung;Choi, Jun-Hyuk;Park, Jin-Hyun;Joo, Jin-Ho;Jun, Byung-Hyuk;Kim, Chan-Joong
    • Progress in Superconductivity
    • /
    • v.10 no.2
    • /
    • pp.79-86
    • /
    • 2009
  • We successfully fabricated C-doped ex-situ $MgB_2$ wires using two different methods such as mechanical alloying(MA) and combined process(CP) of in-situ and ex-situ. In the MA, the precursor powder was prepared with a mixture of $MgB_2$ and 1 at% C powders by planetary ball milling for 0-100 h. In the CP, on the other hand, C-doped $MgB_2$ powder was prepared with Mg, B, and C powders by in-situ process via compaction, sintering, and crushing. The powders prepared by two methods were loaded into Fe tube and then the assemblages were drawn by a conventional powder-in-tube technique. The MA treatment of C-added $MgB_2$ decreased the particles/grains size and resulted in C-doping into $MgB_2$ after sintering, improving the critical current density($J_c$) in high external magnetic field. For the C-doped $MgB_2$ wire by MA for 25 h, the $J_c$ was $4.1{\times}10^3A/cm^2$ at 5 K and 6.4 T, which was 5.9 times higher than that of pure and untreated $MgB_2$ wire. The CP also provided C-doping into $MgB_2$ and improved the $J_c$ in high magnetic field; the C-doped $MgB_2$ wire fabricated by CP exhibited a $J_c$ being 2.3 times higher than that of the ex-situ wire used commercial $MgB_2$ powder at 5 K and 6.0 T($2.7{\times}10^3A/cm^2\;vs.\;1.2{\times}10^3A/cm^2$).

  • PDF

The Hydrogenated Micro-crystalline Silicon(${\mu} c-Si:H$) Films Deposited by Hot Wire CVD Method (Hot Wire CVD법에 의한 수소화된 미세결정 실리콘(${\mu} c-Si:H$) 박막 증착)

  • Lee, Jeong-Cheol;Song, Jin-Su;Park, Lee-Jun
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.37 no.8
    • /
    • pp.17-27
    • /
    • 2000
  • This paper presents deposition and characterization of hydrogenated microcrystalline silicon (${\mu}c$ -Si:H) films on low cost glass substrate by Hot Wire CVD(HWCVD). The HWCVD ${\mu}c$ -Si:H films had deposition rates ranging from 2${\AA}$/sec to 35${\AA}$/sec with the variations of preparation conditions, which was 10 times higher than that of the films obtained from the conventional PECVD method. From the Raman spectroscopy, the prepared silicon films were found to be composed of the mixture of crystalline and amorphous phases. The crystalline volume fraction and average crystallite size, obtained from the Raman To mode peak near 520cm$^{-1}$, were 37-63% and 6-10 nm, respectively. The conductivity activation energy($E_a$) of the ${\mu}c$ -Si:H films, representing the difference of conduction band and Fermi level in an intrinsic semiconductors, increased from 0.22eV to 0.68eV with increasing pressure from 30mTorr to 300mTorr. The increase of $E_a$ with pressure indicates that the deposited films have properties close to intrinsic semiconductors, which is also proved with low dark conductivity of the ${\mu}c$ -Si:H deposited at 300mTorr. The tungsten concentration incorporated into films was about $6{\times}10^{16}atoms/cm^3$ in the samples prepared at wire temperature of 1800$^{\circ}C$.

  • PDF

A Study on the Characteristic of Modified Folded Dipole Antenna (변형된 Folded 다이폴 안테나의 특성 연구)

  • 심재륜
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2004.05b
    • /
    • pp.472-474
    • /
    • 2004
  • In this study, we investigated the characteristics of the input impedance and the gain of a ‘Folded dipole antenna with stub’ by the Method of Moments. The center frequency in this study is 200MHz, the radius of wire is 0.5nm, and the distance between two linear dipoles is 2cm. The inside variation of stub length within 18cm and the outside variation of stub length 4.5cm ive the value of SWR(Standing Wave Ratio) within 3. This means that the impedance matching between the ‘Folded dipole antenna with stub’ and receiver can easily be performed without a supplementary matching circuit.

  • PDF

Property Improvement of YBCO Thick films by EPD with Addition of PEG (PEG 첨가에 의한 YBCO 전착후막의 특성 향상)

  • 소대화;전용우
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.16 no.12
    • /
    • pp.1125-1130
    • /
    • 2003
  • The electrophoretic deposition method using the suspension solution with additives under the electric potential was applied for the fabrication of YBCO superconductor wire. This method was able to simplify the fabrication facilities, and produce an uniform and dense thick film. To improve the critical current density of deposited films, the additive PEGs(Poly Ethylene Glycole) with the molecular weight of 600, 1000 and 3400 were used as chemical binders for the suspension solution. The organic additive (PEG) showed better effects to the properties of YBCO superconductor wire. The PEG improved the adhesion between superconductor particles and suppressed the crack on the surface, which enhanced the surface uniformity and density of YBCO deposited film. It was found that acetone suspension solution showed better deposition properties than the others. The samples fabricated in the solution with the additive, 8 vol.% of 1% PEG(1000), showed the highest critical current density measured as 2300∼2400 A/$\textrm{cm}^2$ at 77 K, 0 T.