• Title/Summary/Keyword: CM Noise

Search Result 431, Processing Time 0.031 seconds

A study on the Frequency Dependence of Dynamic Pyroelectric Properties for $Pb_{1-x}La_{x}Ti_{1-x/4}O_{3}$ (x=0.1) (PLT(10)) Ferroelectric Thin Film ($Pb_{1-x}La_{x}Ti_{1-x/4}O_{3}$ (x=0.1) (PLT(10)) 강유전체 박막에서 동적 초전특성의 주파수 의존성에 관한 연구)

  • Cha, Dae-Eun;Chang, Dong-Hoon;Kang, Seong-Jun;Yoon, Yung-Sup
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.11b
    • /
    • pp.104-107
    • /
    • 2001
  • The fabricated La-modified lead titanate (PLT) thin flim without paling treatment was investigated for modulation frequency dependence of pyroelectric properties by the dynamic method. $Pb_{1-x}La_{x}Ti_{1-x/4}O_{3}$ PLT (x=0.1) thin film having 10 mol% La content was deposited on a $Pt/TiO_{x}/SiO_{2}/Si$ substrate by sol-gel method. The PLT(10) thin film exhibits a relatively excellent dielectric property. The pyroelectric coefficient (p) of the PLT(10) thin film is $6.6{\times}10^{-9}C/cm_{2}\cdot K$ without frequency dependence. The figure of merits for the voltage responsivity and specific detectivity are $1.03{\times}10^{-11}C\cdot cm/J$ and $1.46\times 10^{-9}C\cdot cm/J$, respectively. The PLT(10) thin film has voltage responsivity (Rv) of 5.15 V/W at 8 Hz. Noise equivalent power (NEP) and specific detectivity (D*) of the PLT(10) thin film are$9.93{\times}10^{-8}W/Hz^{1/2}$ and $1.81\times 10^{6}cmHz^{1/2}/W$ at the same frequency of 100 Hz, respectively. The results means that PLT thin film having 10 mol % La content is suitable for the sensing materials of pyroelectric IR sensors.

  • PDF

A study on the Frequency Dependence of Dynamic Pyroelectric Properties for $Pb_{1-x}La_{x}Ti_{1-x/4}O_3$(x=0.1)(PLT(10)) Ferroelectric Thin Film ($Pb_{1-x}La_{x}Ti_{1-x/4}O_3$(x=0.1)(PLT(10)) 강유전체 박막에서 동적 초전특성의 주파수 의존성에 관한 연구)

  • 차대은;장동훈;강성준;윤영섭
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.11a
    • /
    • pp.104-107
    • /
    • 2001
  • The fabricated La-modified lead titanate (PLT) thin flirt without poling treatment was investigated for modulation frequency dependence of pyroelectric properties by the dynamic method. $Pb_{1-x}La_{x}Ti_{1-x/4}O_3$PLT (x=0.1) thin film having 10 mol% La content was deposited on a Pt/$TiO_{x}$/$SiO_2$/Si substrate by sol-gel method. The PLT(10) thin film exhibits a relatively excellent dielectric property. The pyroelectric coefficient (p) of the PLT(10) thin film is 6.6 x $10^{-9}$C/$\textrm{cm}^2$.K without frequency dependence. The figure of merits for the voltage responsivity and specific detectivity are 1.03${\times}$$10^{-11}$/C.cm/J and 1.46 x $10^{-9}$C.cm/J, respectively. The PLT(10) thin film has voltage responsivity ($R_{V}$) of 5.15 V/W at 8 Hz. Noise equivalent power (NEP) and specific detectivity (D*) of the PLT(10) thin film are 9.93 x $10^{-8}$W/Hz$^{1/2}$ and 1.81 x $10^{6}$ cmHz$^{1/2}$/W at the same frequency of 100 Hz, respectively. The results means that PLT thin film having 10 mol % La content is suitable for the sensing materials of pyroelectric IR sensors.

  • PDF

Fabrication and characteristics of pyroelectric infrared sensors using P(VDF/TrFE) film (P(VDF/TrFE) 필름을 이용한 초전형 적외선 센서의 제작 및 특성)

  • Kwon, Sung-Yeol;Kim, Ki-Wan
    • Journal of Sensor Science and Technology
    • /
    • v.8 no.3
    • /
    • pp.226-231
    • /
    • 1999
  • Pyroelectric infrared sensors have been fabricated using P(VDF/TrFE) film with pyroelectric effect. The weight percent and thickness of the poled P(VDF/TrFE) film are 75/25 percent and $25\;{\mu}m$ respectively. For easier fabrication and connection method new top and bottom electrodes design was adapted for human body detecting pyroelectric infrared sensor. An aluminum infrared absorption electrode and bottom electrode were deposited by thermal evaporator. And the device was mounted in TO-5 housing to detect infrared light of $5.5{\sim}14\;{\mu}m$ wavelength. The responsibility, NEP (noise equivalent power) and specific detectivity $D^*$ of the device were $9.62{\times}10^5\;V/W$, $3.95{\times}10^{-7}\;W$ and $5.06{\times}10^5\;cm/W$ under emission energy of $13\;{\mu}W/cm^2$ respectively.

  • PDF

Analysis of Shielding Effectiveness of Low Conductivity Shield Layers within Near-field Region (근거리장에 놓인 저전도율 차폐막의 차폐 효과 분석)

  • Lee, Won-Seon;Lee, Won-Hui;Hur, Jung
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.19 no.2
    • /
    • pp.59-65
    • /
    • 2019
  • The EMI shielding effectiveness of shielding layers thickness was analyzed when the low conductivity shielding layers was placed in the near field of the noise source. A spiral antenna with broadband characteristics was used as the noise source, and graphite was selected as the low conductivity shielding material. Two spiral antennas were constructed to analyze the transmission coefficient between two antennas, and the distances between the transmitting and receiving antennas were 5 cm and 10 cm. The thickness of the shielding layers was changed from 1 um to 200 um. The frequency was changed from 100 MHz to 6 GHz to obtain a maximum SE(Shielding Effectiveness) of 70 dB. In this simulation, electronic shielding was used due to the nature of graphite, which is a shielding film material. Based on these results, we will study how to improve the shielding performance by implementing magnetic shielding in the future.

Evaluation of Fatigue Endurance on Expansion Joint Manufactured Fe-Mn Damping Alloy (Fe-Mn 제진 금속을 적용한 신축이음장치의 피로 내구성 평가)

  • Kim, Ki-Ik;Kim, Young-Jin;Ahn, Dong-Geun;Kim, Cheol-Hwan
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.4D
    • /
    • pp.483-489
    • /
    • 2009
  • The endurance of expansion joint manufactured the Fe-Mn damping alloy reducing noise and vibration is analyzed into FEM (Finite Element Method) and fatigue test. The fatigue test have been performed using the expansion joint manufactured Fe-Mn damping alloy and the hydraulic actuator (25tonf). And the results of fatigue test show that the maximum strength is 237.6 MPa. Also that is 56.6 percent of Fe-Mn damping alloy yield strength (420 MPa). The loading plate size is prepared $57.7cm{\times}23.1cm$ and the loading plate's set position is located on expansion joint. The expansion joint manufactured the Fe-Mn damping alloy had not presented breaking behavior against 2,000,000 times fatigue test and identified the fatigue endurance.

Harmonic frequency analysts of acoustic Barkhausen noise on neutron irradiated material (중성자조사재료의 acoustic Barkhausen noise의 harmonic frequency 분석)

  • Sim Cheul-Muu;Park Seung-Sik;Koo Kil-Moo;Sohn Jae-Min;Lee Chang-Hee
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • autumn
    • /
    • pp.401-406
    • /
    • 1999
  • In relation to a non-destructive evaluation of irradiation damages of micro-structure interstitial, void and dislocation, the changes in the hysteresis loop, Barkhausen noise amplitude and the harmonics frequency due to a neutron irradiation were measured and evaluated. The Mn-Mo-Ni low alloy steel of RPV was irradiated to a neutron fluence of $2.3\times10^{19}\;n/cm^2\;(E\geq1\;MeV)\;at\;288^{\circ}C$. The saturation magnetization of neutron irradiated metal did not change. The neutron irradiation caused the coercivity to increase, whereas susceptibility to decrease. The amplitude of Barkhausen noise parameters associated with the domain wall motion were decreased by a neutron irradiation. The spectrum of Barkhausen noise is analysed with an applied frequency of 4 Hz and 8 Hz, sampling time of $50\;{\mu}sec\;and\;20\;{\mu}sec$. The harmonic frequency shows 4 Hz, 8 Hz, 12 Hz; and 16 Hz reflected from an unirradiated specimen. On the contrary, the harmonic frequency disappeared on the irradiated specimen.

  • PDF

Spectrum analysis of acoustic Barkhausen noise on neutron irradiated material

  • Sim Cheul-Muu;Park Seung-Sik;Park Duck-Gum;Lee Chang-Hee
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • autumn
    • /
    • pp.231-234
    • /
    • 2000
  • In relation to a non-destructive evaluation of irradiation damage of micro-structure of interstitial, void and dislocation, the changes in the hysteresis loop and Barkhausen noise amplitude and the harmonics frequency due to neutron irradiation were measured and evaluated. The Mn-Mo-Ni low alloy steel of reactor pressure vessel was irradiated to a neutron fluence of $2.3\times10^{19}n/cm^2$ $(E\ge1MeV)$ at $288^{\circ}C.$The saturation magnetization of neutron irradiated metal did not change. Neutron irradiation caused the coercivity to increase, whereas susceptibility to decrease. The amplitude of Barkhausen noise parameters associated with the domain wall motion were decreased by neutron irradiation. The spectrum of Barkhausen noise was analyzed with an applied frequency of 4Hz and 8Hz, and a sampling time of 50 $\mu$ sec and 20 $\mu$ sec. The harmonic frequency of Joule effect shows 4Hz, 8Hz, 12Hz and 16Hz reflected from an unirradiated specimen. On the contrary, the harmonic frequency disappeared for the irradiated specimen. Harmonic frequency of induced voltage of sinusoidal magnetic field And Spectrum of Barkhausen noise on material is determined.

  • PDF

Enhancement of Rejection Performance using the PSO-NCM in Noisy Environment (잡음 환경하에서의 PSO-NCM을 이용한 거절기능 성능 향상)

  • Kim, Byoung-Don;Song, Min-Gyu;Choi, Seung-Ho;Kim, Jin-Young
    • Speech Sciences
    • /
    • v.15 no.4
    • /
    • pp.85-96
    • /
    • 2008
  • Automatic speech recognition has severe performance degradation under noisy environments. To cope with the noise problem, many methods have been proposed. Most of them focused on noise-robust features or model adaptation. However, researchers have overlooked utterance verification (UV) under noisy environments. In this paper we discuss UV problems based on the normalized confidence measure. First, we show that UV performance is also degraded in noisy environments with the experiments of an isolated word recognition. Then we observe how the degradation of UV performances is suffered. Based on the UV experiments we propose a modeling method of the statistics of phone confidences using sigmoid functions. For obtaining the parameters of the sigmoidal models, the particle swarm optimization (PSO) is adopted. The proposed method improves 20% rejection performance. Our experimental results show that the PSO-NCM can apply noise speech recognition successfully.

  • PDF

CCD-based EPID and Frame Averaging Technique

  • Kim, Ho-Kyung;Cho, Gyu-Seong;Chung, Yong-Hyun;Ahn, Seong-Kyu;Lee, Hyung-Koo;Kim, Hoi-Nam;Yoon, Sei-Chul
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1998 no.11
    • /
    • pp.297-298
    • /
    • 1998
  • Prototype portal imaging device (EPID) based on CCD camera, which has a $20\times20cm^2$ field of view (FOV), has been developed and then tested by acquiring phantom images for 6 MV x-ray beam. While, among the captured images, each frame suffered notorious quantum noise, the frame averaging largely enhanced the image quality against quantum noise. Over 60 frames averaging, the signal-to-noise ratio (SNR) was increased by $\sim20$ times and contrast was increased about 2 times in the skull-region of the acquired head-phantom image.

  • PDF

A Study on Respiration Measurement Using a Smartphone (스마트폰을 이용한 호흡 측정에 관한 연구)

  • Kang, Sung Jin
    • Journal of the Semiconductor & Display Technology
    • /
    • v.17 no.3
    • /
    • pp.108-112
    • /
    • 2018
  • In this paper, a respiration measurement method using FMCW signal for off-the-shelf smartphone is presented and investigated. The proposed algorithm transmits FMCW signal periodically instead of transmitting continuously so that one can reduce the power consumption from speaker in smartphone and the algorithm complexity. In order to eliminate the clicking noise generated when transmitting FMCW signal, Tukey window with ${\alpha}=0.01$ is applied to prevent the noise from being heard. An application program for Android OS which can transmit FMCW signal through speaker and record the reflected signals through MIC has been developed. Since the total duration of the signal transmission is set to 20msec per 1 second for the experiments, the power consumption can be decreased by 80% compared to the continuous transmission. It was confirmed that the clicking noise is inaudible as long as a smartphone is located at more than 10cm from ears. In the experiments on a sleeping child, the breathing signal of about 0.27Hz was measured.