• Title/Summary/Keyword: CM Function

Search Result 1,500, Processing Time 0.029 seconds

Comparison of Binocular Function in Normal Subjects and Convergence Insufficiency (정상안과 폭주부족안의 양안시기능 검사값 비교)

  • Shim, Hyun-Seog;Shim, Moon-Sik;Kim, Sang-Hyun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.3
    • /
    • pp.287-291
    • /
    • 2010
  • Purpose: The aim of this study was to compare binocular functions such as near point of convergence (NPC), AC/A ratios, heterophoria, accommodation, accommodation lag, positive relative accommodation (PRA), negative relative accommodation (NRA), positive relative convergence (PRC), negative relative convergence (NRC) in normal subjects and convergence insufficiency. Methods: 86 subject (male n=45, female n=41, mean $age{\pm}SD=23.27{\pm}2.85$ years) without amblyopia, strabismus, and ocular pathology were studied. Forty three patients each group were classified as normal subjects and convergence insufficiency group based on AC/A ratio and far and near phoria. Binocular function of the two groups was measured using phoropter. r. Results: The values between normal subjects and convergence insufficiency were 5.71 cm and 7.07 cm for NPC, 5.28 and 2.81 for Heterophria AC/A, 0.92 exo/3.36 exo and 2.17 exo/10.84 exo for far and near phoria, 15.49/23.30/13.30 and 13.50/20.02/9.09 for PRC, respectively. However, there were no significant differences between normal subjects and convergence insufficiency for accommodative amplitude, accommodative lag, PRA, NRA, BI vergence test, BO vergence test, NRC. Conclusions: Both groups were a significant difference for cover test, NPC, Heterophria AC/A, far and near phoria, break point of PRC, and recovery point of PRC.

Peripheral Dose Distributions of Clinical Photon Beams (광자선에 의한 민조사면 경계영역의 선량분포)

  • 김진기;김정수;권형철
    • Progress in Medical Physics
    • /
    • v.12 no.1
    • /
    • pp.71-77
    • /
    • 2001
  • The region, near the edge of a radiation beam, where the dose changes rapidly according to the distance from the beam axis is known as the penumbra. There is a sharp dose gradient zone even in megavoltage photon beams due to source size, collimator, lead alloy block, other accessories, and internal scatter ray. We investigate dosimetric characteristics on penumbra regions of a standard collimator and compare to those of theoritical model for the optimal use of the system in radiotherapy. Peripheral dose distribution of 6 W Photon beams represents penumbral forming function as the depth. Also we have discussed that the peripheral dose distribution of clinical photon beams, differences between calculation dose use of emperical penumbral forming function and measurements in penumbral region. Predictions by emperical penumbral forming functions are compared with measurements in 3-dimensional water phantom and it is shown that the method is capable of reproduceing the measured peripheral dose values usually to within the statistical uncertainties of the data. The semiconductor detector and ion chamber were positioned at a dmax depth, 5cm depth, 10cm depth, and its specific ratio was determined using a scanning data. The effective penumbra, the distance from 80% to 20% isodose lines were analyzed as a function of the distance. The extent of penumbra will also expand with depth increase. Difference of measurement value and model functions value according to character of the detector show small error in dose distribution of the peripheral dose.

  • PDF

비정질 실리콘 태양전지 후면 반사막 적용을 위한 저온 증착된 AZO 박막 특성에 관한 연구

  • Kang, Junyoung;Park, Hyeongsik;Yi, Junsin
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.315-315
    • /
    • 2016
  • The hydrogenated amorphous silicon (a-Si:H) thin film solar cells using n/Al or n/Ag/Al back reflector have low short circuit current (Jsc) due to high absorption coefficients of Al or work function difference between n-layer and the metal. In this article, we utilized aluminum doped zinc oxide (AZO) to raise the internal reflectance for the improvement of short current density (Jsc) in a-Si:H thin film solar cells. It was found that there was a slight increase in the reflectance in the long wavelength range at the process temperature of 125oC due to improved crystalline quality of the AZO back reflector. The optical band gap (Eg) and work function were affected by the temperature and so did the internal reflectance. The increased internal reflectance within the solar cell resulted in Jsc of 14.94 mA/cm2 and the efficiency of 8.84%. Jsc for the cell without back reflector was 12.29 mA/cm2.

  • PDF

Modeling Knot Properties for Mongolian Pine in Northeast China

  • Jia, Weiwei;Li, Fengri;Jiang, Lichun
    • Journal of Korean Society of Forest Science
    • /
    • v.97 no.5
    • /
    • pp.485-491
    • /
    • 2008
  • This study was performed in 14 unthinned Mongolian pine (Pinus sylvestris L. var. mongolica Litvin) plantations in northeast China. Data were collected on 70 sample trees of different canopy position with diameter at breast height (DBH) ranging from 6.9 cm to 34.5 cm. Diameter and length of knots per whorl below the living crown were studied by different vertical levels divided by relative knot height (RHK) in this paper. Models taking DBH and height to the crown base (HCB) as independent variables were developed to predict knot diameter (KD) in a sample whorl. According to the vertical distribution tendency and range of sound knot length (KLsound), KLsound was modeled as multiple linear function of DBH, KD and relative knot height (RHK). The loose knot length (KLloose) was described as a function of DBH, KD and height above the ground for knots (HK) in a mixed log-linear model. Results from this study can provide abundant knot information so as to describe the knot size and vertical distribution tendency of Mongolian pine plantation.

Let-out of the Function of Sound Tube in the Bell King Songdok the Great (에밀레종의 萬波息笛音管의 기능을 살리는 方策)

  • 이병호
    • The Journal of the Acoustical Society of Korea
    • /
    • v.19 no.6
    • /
    • pp.3-9
    • /
    • 2000
  • The Bell King Songdok the Great tolls magnificient sound that would be a great vehicle which brings all beings to the Sutras. Since 693, there was a magic flute, MANPASIKJUK, which was in existence in Shilla Dynasty that could lull all the evil-wawes, such an plaques, storms, Droughts, Famines and even Enemies. Thus, a sound tube, MANPASIKJUK, was erected in the crown of the Bell Songdok the Great so as to be effective to emit the nominal frequency tone whenever the Bell tolls for the national prosperity and welfare the People. Therefore, the Bell makers tried to fine the transmissibility condition through the sound tubr, several times during 34 years, However, it seems to be unfinished. Ever since, all of the korean Brahman Bell have the sound tubes of MANPASIKJUK, but none is performed their own functions. Here, one of the way to let the function of the sound tube of MANPASIKJUK out in the Bell Songdok the Great is proposed. There are two steps: the 1st is to elongate 18cm to the present length 77cm to fulfill the transmissibility condition for the nominal frequency of sound is emitted through the corrected sound tybe. 2nd step is to rise to 95% of the emission of the tone of nominal frequency, so that an exponential hem with the flare constant 2.8m-1, length 2.259m and the radius of the mouth 1.772m is to be extended to the corrected sound tube.

  • PDF

A Study on the Characteristics of Mass Transfer in Hollow Fiber Membranes (중공사막에서의 물질전달 특성에 관한 연구)

  • 김기범;김종석;김종수;유일수;이왕로;김성종
    • Membrane Journal
    • /
    • v.14 no.2
    • /
    • pp.142-148
    • /
    • 2004
  • This paper presents the enhancement of oxygen transfer efficiency using vibrating intravascular lung assist device (VIVLAD) for patients having chronic respiratory problems. The flow rate was controlled by the pump and monitored by a built-in flow meter. The vibration apparatus was composed of a piezo-actuator, a function generator, and a power amplifier. Gas flow rates of up to 6 L/min through the 120-cm-long hollow fibers have been achieved by exciting a piezo-actuator. The output PVDF sensor and FRF (frequency response function) were investigated by various frequency in VIVLAD. As a result, the maximum oxygen transfer rate was found to occur with maximum amplitude and the transfer of vibration to the hollow fiber membranes. It was excited by the frequency band of 35 Hz at various distilled water flow rates, and various module types.

The Compaction Characteristics Analysis of Domestic River Sands (국내 강모래의 다짐특성 분석)

  • Hwang, Seong-Chun;Oh, Byung-Hyun
    • International Journal of Highway Engineering
    • /
    • v.7 no.4 s.26
    • /
    • pp.31-39
    • /
    • 2005
  • Tests are conducted to analyze the compaction characteristics of domestic river sand used frequently for backfill in construction of electrical pipeline. As a result of test, the range of specific gravity of sand is found to be in between 2.63 and 2.67, and of maximum dry weight of sand is in between $1.70g/cm^3\;and\;1.86g/cm^3$. Also, the optimum moisture content is found to be in between 11.3% and 13.8%. The variability of compaction degree with respect to compaction energy is well captured by hyperbolic function.

  • PDF

Characteristics of $(Pb_{1-x}La_x)(Zr_{0.5}Ti_{0.5})O_3$ thin films as a function of La content ($(Pb_{1-x}La_x)(Zr_{0.5}Ti_{0.5})O_3$ 박막의 La 치환량에 따른 특성)

  • Jang, Nak-Won;Lee, Seong-Hwan;Yi, Dong-Young;Kim, Dong-Hun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.30 no.8
    • /
    • pp.894-900
    • /
    • 2006
  • The electrical characteristics associated with crystal structure changes as a function of La content for $(Pb_{1-x}La_x)(Zr_{0.5}Ti_{0.5})O_3$ thin films were investigated for applications in memory capacitors. Tetragonality of PLZT films decreased with increasing La content. Thin films with La $\geq$ 20 mol% were found to be cubic. Films with La $\geq$ 12 mol% exhibited broader dielectric peaks compared to those of bulk ceramics and behaved as relaxer ferroelectrics. Tetragonal PLZT film with 12 mol% La had a dielectric constant maximum of 1330 at room temperature and a charge storage density of ${\sim}18{\mu}C/cm^2$ at 5 V. Decrease in coercive field and remnant polarization with increase in La content were resulting from less dipolar response caused by the decreased crystal anisotropy. The leakage current densities $<10^{-8}A/cm^2$ up to 5 V bias voltage were observed for the films with La $\geq$ 14 mol%.

Primary Dispersion Patterns and Widths of Elements in Altered Granitic Wallrock around the Gold-bearing Quartz Veins at the Mugeug Mine (무극 함금석영맥광상 화강암질모암에서의 원소들의 분산형태와 분산범위)

  • Hwang, In Ho;Chon, Hyo Taek
    • Economic and Environmental Geology
    • /
    • v.27 no.5
    • /
    • pp.451-458
    • /
    • 1994
  • Geochemical studies on gold-bearing quartz veins and granitic wallrocks from the Mugeug mine were carried out in order to investigate primary dispersion patterns of elements and to quantify primary dispersion widths of elements with distance from the gold-bearing quartz veins. The best fitting model of dispersion pattern in altered wallrock around the gold-bearing quartz veins is an exponential function for Au, As, Sb, $Na_2O$ and Sr, and a quadratic function for CaO, $K_2O$, MnO, Ba, Rb and Cs. The primary dispersion widths are 15~343 cm in the hanging wall, and 33~173 cm in the footwall. The width of primary dispersion in the hanging wall is twice as thick as that in the footwall mainly due to the thermal effect and volatile components. The primary dispersion width is increased as the increase of gold-bearing quartz vein width and contents of As and Sb in gold-bearing quartz veins, but is not related to Au content in gold-bearing quartz veins.

  • PDF

Isolated Working Canine Heart Perfusion Apparatus for Evaluation of Myocardial Protection Methods (심장기능 평가를 위한 견 적출심장 관류장치의 설계)

  • 이종국
    • Journal of Chest Surgery
    • /
    • v.21 no.2
    • /
    • pp.246-253
    • /
    • 1988
  • An in vitro model providing with a recirculating perfusion apparatus using an isolated canine heart and its autogenous blood, which was prepared for study of myocardial protection method. This apparatus was easily used by quick connect system and maintained well heart function for about 2 hours. The Langendorff perfusion was initiated for a 10 minute period by introducing perfusate at 37` into the aorta from aortic reservoir located 100 cm above the heart. The isolated perfused working canine heart model was a left heart preparation in which oxygenated perfusion medium [at 37K] entered the cannulated left atrium at a constant flow rate [900ml/ min] under 20 mmHg overflow system and was spontaneously ejected[no electrical pacing] via an cannula against a hydrostatic pressure of 80 cm H2O. During this working period, various indices of cardiac function were measured. The cardiac functions were stable for over 2 hours with perfusion of Krebs-Henseleit solution and autologous blood[1:1] mixture in volume and maintained heart rate ]]3-122/bpm peak systolic pressure 109-113 mmHg, cardiac output 900 ml / min and left atrial mean pressure 8-9 mmHg. In this model, the efficiency of myocardia] protection could be easily measured by means of functional, enzymatic, biochemical and ultrastructural assessment. And also, we believe this model to be a useful assessment screening model of recovery state after long duration of myocardial preservation of donor heart without difficult transplantation procedures.

  • PDF