• Title/Summary/Keyword: CLOG

Search Result 42, Processing Time 0.028 seconds

Iris Pattern Positioning with Preserved Edge Detector and Overlay Matching

  • Ryu, Kwang-Ryol
    • Journal of information and communication convergence engineering
    • /
    • v.8 no.3
    • /
    • pp.339-342
    • /
    • 2010
  • An iris image pattern positioning with preserved edge detector, ring zone and clock zone, frequency distribution and overlay matching is presented in this paper. Edge detector is required to be powerful and detail. That is proposed by overlaying Canny with LOG (CLOG). The two reference patterns are made from allocating each gray level on the clock zone and ring zone respectively. The normalized target image is overlaid with the clock zone reference pattern and the ring zone pattern to extract overlapped number, and make a matched frequency distribution to look through a symptom and position of human organ and tissue. The iterating experiments result in the ring and clock zone positioning evaluation.

수압파쇄기법에 의한 우물 산출성 증대효과 검증

  • 백건하;김형수;윤윤영;전재수
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2003.04a
    • /
    • pp.283-286
    • /
    • 2003
  • 국내의 12개소 저산출 우물을 대상으로, 외국의 유정들에서의 산출량 증대를 위하여 많이 사용되고있는 인공수압파쇄 방법을 적용하여 산출성 증대 효과를 검증하였다. 12개소에 대하여 수압파쇄시험 전후로 양수 시험을 실시하여 투수성 증대 등의 효과와 비양수량을 정량적으로 평가한 결과, 비양수량의 경우 전체적으로 평균 약 45%의 증가하였으며 투수량계수 또한 약 26%가 증가하였다. 이러한 결과는 인공수압파쇄 방법이 대수층내 열극의 생성 혹은 확장 및 균열내의 막힘(clog) 물질 제거를 통해 투수성을 상당히 개선시킨 것으로 평가된다. 특히, 현재까지의 시험 결과, 퇴적암류 지역에서 보다 화성암류 지역에서의 시험 결과가 양호하게 나타났다. 화성암 지역에서 개발된 홍천에서의 사례를 볼 때, 고압의 주입을 통하여 상부 및 하부의 파쇄대가 확장 연결되고, 이들 파쇄 열극에 부착된 광물학적, 생물학적 막힘 물질이 제거되면서 산출성이 증대되는 것으로 나타났다.

  • PDF

Effect of Wall Thickness on Thermal Behaviors of RC Walls Under Fire Conditions

  • Kang, Jiyeon;Yoon, Hyunah;Kim, Woosuk;Kodur, Venkatesh;Shin, Yeongsoo;Kim, Heesun
    • International Journal of Concrete Structures and Materials
    • /
    • v.10 no.sup3
    • /
    • pp.19-31
    • /
    • 2016
  • The objective of this paper is to investigate the effect of thickness and moisture on temperature distributions of reinforced concrete walls under fire conditions. Toward this goal, the first three wall specimens having different thicknesses are heated for 2 h according to ISO standard heating curve and the temperature distribution through the wall thickness is measured. Since the thermal behavior of the tested walls is influenced by thickness, as well as moisture content, three additional walls are prepared and preheated to reduce moisture content and then tested under fire exposure. The experimental results clearly show the temperatures measured close to the fire exposed surface of the thickest wall with 250 mm thickness is the highest in the temperatures measured at the same location of the thinner wall with 150 mm thickness because of the moisture clog that is formed inside the wall with 250 mm of thickness. This prevents heat being transferred to the opposite side of the heated surface. This is also confirmed by the thermal behavior of the preheated walls, showing that the temperature is well distributed in the preheated walls as compared to that in non-preheated walls. Finite element models including moisture clog zone are generated to simulate fire tests with consideration of moisture clog effect. The temperature distributions of the models predicted from the transient heat analyses are compared with experimental results and show good agreements. In addition, parametric studies are performed with various moisture contents in order to investigate effect of moisture contents on the thermal behaviors of the concrete walls.

Biomass Regressions of Pinus densiflora Natural Forests of Four Local Forms in Korea (한국산(韓國産) 4개(個) 지역형(地域型) 소나무천연림(天然林)의 물질(物質) 현존량(現存量) 추정식(推定式)에 관(關)한 연구(硏究))

  • Park, In Hyeop;Kim, Joon Seon
    • Journal of Korean Society of Forest Science
    • /
    • v.78 no.3
    • /
    • pp.323-330
    • /
    • 1989
  • Pinass densiflora natural forests of four local forms in Korea were studies to investigate effective biomass estimation method. Dimension analysis was used and three allometric regression models, such as logWt=A+BlogD, logWt=$A+B1ogD^2H$ and 1ogWt=A+BlogD+ClogH were applied to estimate biomass, The most accurate estimation was made by the regression model of logWt=A+BlogD+ClogH where Wt is dry weight, D is diameter at breast height, and H is tree height. However, dry weights of cones and dead branches were remotely related to tree size factor, such as D and H. In the interest of practical use. generalized allometric regressions for all samples trees of four stands were computed and analysis of covariance was used to compare the allometric regressions among the four stands. Based on the test criteria applied in this study, significant differences were found in terms of error variance and regression intercept, not in terms of regression slope. These trends suggest a generalized biomass regression is not valid for accurate estimation over a range of four local form stands.

  • PDF

2D-QSAR Analyses on The Tyrosinase Inhibitory Activity of 2-[(2,6-Dioxocyclohexyl)methyl]-cyclohexane-1,3-dione Analogues (2-[(2,6-Dioxocyclohexyl)methyl]cyclohexane-1,3-dione 유도체의 Tyrosinase 저해활성에 관한 2D-QSAR 분석)

  • Kim, Sang-Jin;Sung, Nack-Do
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.40 no.4
    • /
    • pp.383-390
    • /
    • 2014
  • The following conclusion was made from the 2D-QSAR model for the tyrosinase inhibitory activity according to the variation of the substituents R1 and R2 in analogues of compound 2-[(2,6-dioxocyclohexyl)methyl]cyclohexane- 1,3-dione (1-23). The best optimized 2D-QSAR model was $Obs.pI_{50}=-0.295({\pm}0.031)TDM$ $-0.120({\pm}0.014)DMZ+0.135({\pm}0.050)DMX.R_2+6.382({\pm}0.17)$, and the correlation $r^2=0.905$) of which was greater than its predictability ($q^2=0.843$). The magnitude of the effect of tyrosinase inhibitory activities was in order of TDM > $DMX.R_2{\geq}DMZ$, and it tended to increase as the hydrophobicity of substrate molecule (ClogP > 0) as well as the steric favor of substituent $R_1$ increased. The analysis of the model implies that inhibitory activity of substrate molecule will increase as $DMX.R_2$ (Dipole moment X component of $R_2$-substituent) increases, while TDM (Total Dipole Moment) and DMZ(Dipole Moment of Z-Component) decrease. As such, it is deemed feasible to conclude, that in order to increase the inhibitory effect, it would be rather desirable to replace the polar groups within the molecules with non-polar functional groups.

Experimental Study on the Spalling Properties of Ultra High Strength Concrete containing Amorphous Metallic Fiber (비정질강섬유를 혼입한 초고강도콘크리트의 폭렬특성에 관한 실험적 연구)

  • Choe, Gyeong-Cheol;Kim, Gyu-Yong;Kim, Hong-Seop;Hwang, Eui-Chul;Nam, Jeong-Soo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.3
    • /
    • pp.111-118
    • /
    • 2019
  • This study examined the effect of amorphous metallic (AM) fibers on the spalling properties of ultra high strength concrete. Six specimens with concrete strengths of 100 MPa and 150 MPa were evaluated with mix proportions of polypropylene (PP) fibers of 0.15% by concrete volume, and proportions of AM fibers of 0.3% and 0.5% by concrete volume. These specimens were then heated in accordance with the ISO-834 heating curve. The movement of water vapor through a pore network formed by molten PP fibers was found to be a dominant factor controlling the spalling of high-strength concrete. Spalling control was not found to be significantly affected by the addition of 0.3% AM fibers; however, when 0.5% AM fibers was added, cracking was limited and so were paths for water vapor migration, increasing the likelihood of a moisture clog and creating the differential internal pressure often blamed for concrete spalling.

A Comparative Analysis of Dust Particles Collected by Cleaning Equipments in Subway Tunnel (도시철도 터널 내 청소장치별 집진먼지 비교 분석)

  • Lee, Young-Kwon;Kim, Il-Hong;Jo, Byung-Ki;Kim, Man-Hwa;Park, Jong-Heon
    • Proceedings of the KSR Conference
    • /
    • 2011.05a
    • /
    • pp.1388-1398
    • /
    • 2011
  • Air pollution in subway tunnel is primarily caused from the wear of metallic materials. As undesirable substance, PM(Particulate Matter) can especially harm the health of passengers and workers as well as clog the main parts of rolling stock such as inverters. To improve the air quality in subway tunnel, SMRT(Seoul Metropolitan Rapid Transit Corporation) has developed anti-pollution devices such as Magnetic Dust Collector, Vacuum Cleaner For Rail Road and Particulate Removing Sprinkler Vehicle. Introducing these mechanical devices, this paper is mainly devoted to explaining the characteristics of collected dust according to the result of particle-size analysis and componential analysis.

  • PDF

Design, Synthesis, and Antimicrobial Activity, of New 1,4-disubstituted Octahydroquinoxaline-2,3-dione Derivatives

  • Hussein, Mostafa A.
    • Bulletin of the Korean Chemical Society
    • /
    • v.32 no.5
    • /
    • pp.1511-1518
    • /
    • 2011
  • A series of 1,4-disubstituted octahydroquinoxaline-2,3-dione derivatives was prepared through two steps reaction. The latter involves the formation of N,N-disubstituted cyclohexane-1,2-diamine derivatives (la-j) through reductive alkylation of 1,2-cyclohexanediamine with different aldehydes in presence of sodium cyanoborohydride. Fusion of compounds (1a-j) with diethyl oxalate affording the target compounds (2a-j). Elucidation of structures of compounds (2a-j) was based upon different spectral data as well as the elemental methods of analyses. In addition, mass spectrometry and X-ray diffraction analyses were carried out. Moreover, the lipophilicity of the target compounds as expressed from the Clog P. Most of the test compounds (2a-j) showed weak to moderate antibacterial and antifungal activities against most of the used bacterial and fungal strains in comparison to chloramphenicol and clotrimazole as reference drugs respectively.