• Title/Summary/Keyword: CI-이온

Search Result 95, Processing Time 0.031 seconds

Study on PVC Mixed Silver Iodide Membrane Electrode (PVC 를 섞은 요오드화은 막전극에 관한 연구)

  • Kwon Young-Soon;Kim Jung-Hee;Park Kee-Chae
    • Journal of the Korean Chemical Society
    • /
    • v.20 no.6
    • /
    • pp.486-493
    • /
    • 1976
  • The PVC mixed silver iodide pellet was prepared by means of the Infrared Pellet presser and the pellet was used as an indicating membrane electrode, to measure the potentials for various silver ion activities, ranging from $10^{-1}$ to $10^{-6}$ M. The potential responses to silver ion activities were linear and the slope was much close to Nernstian relation as compared with that of the pure silver iodide pellet membrane electrode and the PVC coated silver iodide pellet membrane electrode. The mechanical property and chemical durability of this electrode were found much better than the others. This electrode did not show significant response to the other except silver ion, but had good response to halide ions, i.e., iodide, chloride, bromide and cyanide ions, in the concentration range $10^{-1}$ to $10^{-6}$ M. This electrode could be used as an indicating electrode in potentiometric titrations of single halide ion and also halide mixture with standard solution of silver nitrate.

  • PDF

Reduction of AgCl to Ag by $Na_2CO_3$ ($Na_2CO_3$에 의한 AgCl의 Ag 환원)

  • 박경호;노범식;손정수
    • Resources Recycling
    • /
    • v.5 no.1
    • /
    • pp.29-33
    • /
    • 1996
  • The cominnn plocesses lor rccoremg silver irom silvcr conlaincd waster are the lcachmg silver hy HNO;. the srlcctive precipilillion of sliver ion lo AgCl and thc rcduchon of Ag wrfh ;I proper reductant. In this sludy, thc reduction of AgCI lo Ag was invesllngated by using Na, CO, as a rcd\icta~lt. The variations wcic reaction time. ttmpcrarure thc amount of NalCO, . and the resulls %, ere analyzcd by using sialist~c:d tecl~niques such as the ]polynomial rcgressiun analysis and the response surh~ce method. More than Yh% Ag analyzed was rcduced 1rtm AgCI at 62UT. I hour ullder condillon of 2 stnlchio~nctric ratio of Na iCO, !AgCI.

  • PDF

Phosphorus Adsorption by Layered Double Hydroxide (층상이중수산화물을 이용한 인 흡착)

  • Jung, Yong-Jun;Min, Kyung-Sok
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.4
    • /
    • pp.404-410
    • /
    • 2005
  • A series of batch type adsorption experiments were performed to remove aquatic phosphorus, where the layered double hydroxide (HTAL-CI) was used as an powdered adsorbent. It showed high adsorption capacity (T-P removal: 99.9%) in the range of pH 5.5 to 8.8 in spite of providing low adsorption characteristics (pH<4). The adsorption isotherm was approximated as a modified Langmuir type equation, where the maximum adsorption amount (50.5mg-P/g) was obtained at around 80mg-P/L of phosphorus concentration. A phosphate ion can occupy three adsorption sites with a chloride ion considering the result that 1 mol of phosphate ion adsorbed corresponded to the 3 moles of chloride ion released. Although the chloride ion at less than 1,000mg-CI/L did not significantly affect the adsorption capacity of phosphate, carbonate ion inhibited the adsorption property.

반사계를 이용한 헬리콘 플라즈마 밀도측정

  • An, Chan-Yong;Wang, Seon-Jeong;Park, Min;Kim, Seon-Ho;Gu, Dong-Jin;Kim, Seong-Gyu
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.264-264
    • /
    • 2012
  • 자화된 플라즈마 매질 내부에 진행하는 전자기파중에서 ${\omega}_{ci}$ ${\ll}({\omega}_{ci}{\omega}_{ce})_{1/2}{\ll}{\omega}{\ll}{\omega}_{ce}{\ll}{\omega}_{pe}$의 주파수 대역을 사용하여 헬리콘 방전을 발생시킨다. 수 kW의 RF 출력을 사용하는 헬리콘 플라즈마원은 자기장, 중성가스 압력 및 RF 주파수 등을 포함한 방전 조건에 따라 급격하게 플라즈마 밀도가 증가하고, 유사한 플라즈마 발생원에 비하여 높은 효율을 가진다. 이러한 헬리콘 플라즈마가 높은 이온화 효율을 갖는 원인을 알아보기 위해 반사계로 플라즈마 밀도를 측정하였다. 본 연구에서는 helical 타입의 안텐를 이용하여 직경 15 cm pyrex관 내부에 플라즈마를 발생시켰고, 플라즈마 진단을 위해 33~40 GHz의 주파수로 FMCW방식을 이용한 반사계로 플라즈마 밀도를 측정하였다.

  • PDF

Experimental Study of Chlorides Ion Diffusion Characteristics under Combined Condition of Chlorides and Sulfates (염해 및 황산염의 복합작용에 따른 염소이온 확산특성의 실험적 연구)

  • 오병환;김선우;정상화;서정문
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.10a
    • /
    • pp.413-418
    • /
    • 2000
  • The test results on the deterioration process of concrete under single and combined action of chloride penetration have been obtained. Within the test period of 15 weeks, it is seen that the internally penetrated chloride ion contents are slightly less in the combined action of NaCI and $Na_2SO_4$ than the single action of NaCI. Also the theoretical prediction of chloride penetration based on measured diffusion coefficient agress well with the test data of single deterioration process but disagress with that of combined process. Therefore it should be needed that improved chloride diffusion model for the combined deterioration process.

  • PDF

Phosphorus Removal by Aluminium Ion Generated with the Pitting Corrosion of Aluminium (알루미늄의 부식으로 발생한 알루미늄 이온에 의한 인 제거)

  • Cheong Kyung-Hoon;Jung Oh-Jin
    • Journal of Environmental Science International
    • /
    • v.8 no.6
    • /
    • pp.705-710
    • /
    • 1999
  • The fundamental experiments on the phosphorus removal from water were carried out by the batch and continuous reactors which used aluminium and copper plate. In this systems, the phosphorus was removed by aluminium ion generated with the electrochemical interaction (pitting corrosion) of aluminium and copper. In the batch experiments, the efficiencies of phosphorus removal increased when the surfaces of aluminium and copper plate were brushed. The phosphorus removal by aluminium ion was affected the copper plate and NaCI in this system. The optimal pH values were 5 and 6 for the phosphorus removal. The efficiency of phosphorus removal increased with increasing NaCI concentration, surface area of aluminium and copper plate. The $CUSO_4{\cdot}5H_2O$ instead of copper plate could be used as Cu source. The effluent $PO_4-P$ concentration as low as 2 $mg/{\ell}$ could have been obtained during the continuous experiment at HRT of 48 hrs.

  • PDF

헬리콘 플라즈마의 연구 현황

  • 엄세훈;장홍영
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2000.02a
    • /
    • pp.183-183
    • /
    • 2000
  • Aigrain에 의해 Helicon이라는 이름이 명명된 이후, helicon은 저온의 금속과 같은 높은 전도도(conductivity)를 갖는 매질이나 강한 자기장이 걸려있는 plasma를 전파해 나가는 저주파 전자기장을 지칭해왔다. 이온화된 개스에서 이러한 전자기장은 전자 공명 주파수(electron cyclotron frequency)와 이온 공명 주파수(ion cyclotron frequency) 사이의 주파수로 전파하며 전리층 (ionosphere)을 통과하며 발생하는 가청 주파수 영역대의 음조가 강하하는 현상에 의해 low-frequency whistler라고도 불린다. Helicon wave plasma는 Boswell에 의해 처음 발생된 후, 높은 이온화율(~100%)로 인해 많은 연구가 이루어져 왔다. 1985년에 Chen은 helicon plasma의 높은 이온화율을 설명하기 위해 Landaudamping을 제시하였다. 이러한 설명은 1997년에 Shamrai에 의해 TG mode가 도입되기 전까지 직접적인 실험결과 없이 helicon plasma 발생의 mechanism으로 받아들여졌다. shamrai의 이론에 의하면 정전기파(electrostatic wave)는 plasma의 표면(surface)에서 강하게 감쇄되어 energy를 전달하게 된다. Cho는 radial density 분포가 외각보다 중심이 높을 경우 TG wave의 power 전달이 중심에서 일어날 수 있음을 계산하였다. Helicon plasma의 특성은 높은 이온화율에 의한 높은 밀도($\geq$1012cm3), 1-2 kW의 rf power에서 상대적으로 낮은 전자 온도( 4eV), $\omega$ci $\omega$LH<$\omega$ $\omega$ce $\omega$pe 영역대의 주파수, 자기장 50-1200 Gauss, 압력 1-10 mTorr로 특정지을 수 있다. 이러한 외부분수들의 조건에 k라 helicon plasma는 여러 종류의 mode로 존재한다. Degeling은 이러한 mode의 변화를 capacitive mode, inductive mode, 그리고 helicon mode(wave mode)의 세가지 부분으로 구분하였다. Helicon plasma가 갖는 높은 이온화율은 여러 가지 응용으로의 가능성을 가지고 있다. 그 예로 plasma processing, plasma wave에 의한 입자 가속, 그리고 가스 레이저 활성 매질 발생 등이 있다. 특히 plasma processing의 경우 helicon plasma는 높은 밀도, 비교적 낮은 자기장, remote operation 등이 가능하다는 점에서 현재 연구가 활발히 진행되고 있다. 상업용으로도 PMT와 Lucas Signatone Corp.에 서 helicon source가 제작되었다. 또한 높은 해리율을 이용하여 저유전 물질인 SiOF의 증착에서 적용되고 있다. 이 외에도 다수의 연구결과들이 발표되었다.

  • PDF

감압증류법에 의한 $^{32}$P 제조

  • 한현수;김재록;박춘득;윤병목;조운갑;박울재
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.11b
    • /
    • pp.565-570
    • /
    • 1996
  • $^{32}$P는 순수한 $\beta$$^{-}$ 방출핵종(방출에너지 = 1.71 MeV, 반감기 = 14.3일)이며 의료용, 표지화합물 합성용, 유전공학 실험용 등으로 널리 사용되므로 고품질의 $^{32}$P의 수요에 부응하기 위해 감압증류법을 개발하였는 바 그 방법과 결과는 다음과 같다. 연구로 2호에서 중성자 조사된 황 표적을 감압 증류용기내에서 5~10 mmHg의 감압하에 200~30$0^{\circ}C$로 가열하여 황을 증류해 낸 다음 묽은 염산을 역류시켜 넣고 $^{32}$P 를 울궈냈다. 이 용액을 이온교환 수지로 정제하여 약 60 mCi/batch의 정제 $^{32}$P를 얻었다. 이온교환수지에 흡착되는 $^{32}$P의 방사능은 전체의 3% 미만이었고 여기에 흡착되는 불순 핵종은 $^{131}$ Ba, $^{85}$ Sr, $^{59}$ Fe, $^{65}$ Zn, $^{60}$Co이었다. 이 방법으로 얻은 $^{32}$P 최종제품은 핵종순도 >99%, 방사화학적 순도 >98%, 고형성분 함량 <1.2 mg/mL 이어서 그 품질이 우수함을 알 수 있었다.

  • PDF

MC-50 싸이클로트론을 이용한 Mn-54 제조

  • 서용섭;양승대;전권수;채종서;이동훈;김유석;이종두
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1995.05b
    • /
    • pp.965-970
    • /
    • 1995
  • 원자력병원의 MC-50 싸이클로트론을 이용하여 표준선원용으로 사용되는 $^{54}$Mn를 $^{59}$ Co(p, $\alpha$pn) 핵반응으로 생산하고 이온교환수지법을 통하여 무담체의 $^{54}$Mn를 11.85$\mu$Ci/ $\mu$Ah의 수율로 분리하였다. 또한 $^{59}$ Co(p,$\alpha$pn)$^{54}$Mn 핵반응에 대한 여기함수를 stacked foil 방법으로 측정하였고, 그 결과 threshold energy는 27.3 MeV이었으며 41.2MeV에서 최대치의 핵반응단면적 47.4mb를 나타내었다.

  • PDF

Hydrogeochemistry and Occurrences of Natural Radionuclides Uranium and Radon in Groundwater of Wonju Area (원주지역 지하수의 자연방사성물질 우라늄과 라돈의 산출 특성과 수리지화학)

  • Lee, Byeongdae;Cho, Byung Uk;Moon, Hee Sun;Hwang, Jae Hong
    • The Journal of Engineering Geology
    • /
    • v.29 no.4
    • /
    • pp.495-508
    • /
    • 2019
  • We measured the concentrations of natural radionuclides (uranium and radon) and major elements in groundwater collected from forty wells located in Wonju area to investigate the hydrochemistry and the occurrence of these radionuclides. The range of electrical conductivity (EC) value in the study area was 73~400 μS/cm. In addition to the increase of EC value, the content of cations and anions also tends to increase. Uranium concentrations ranged from 0.06~50.5 ㎍/L (median value, 1.55 ㎍/L) and radon concentrations ranged from 67~8,410 pCi/L (median value, 1,915 pCi/L). Uranium concentrations in 3 well, 7.5% of the samples, exceeded 30 ㎍/L, the maximum contaminant level (MCL) proposed by the US Environmental Protection Agency (EPA), based on the chemical toxicity of uranium. Radon concentrations in 9 wells, 22.5% of the samples, and 1 well, 2.2% of the samples, exceeded 4,000 pCi/L (AMCL of the US EPA) and 8,100 pCi/L (Finland's guideline level), respectively. Concentrations of uranium and radon related to geology of the study area showd the highest values in groundwater of the biotite granite area. Uranium and radon contents in the groundwater are comparatively low compared to those in other countries with similar geological settings. It is likely that the measured value was lower than the actual content due to the inflow of shallow groundwater by the lack of casing and grouting.