• Title/Summary/Keyword: CFX-5

Search Result 161, Processing Time 0.025 seconds

Flow Characteristics of the Servo Valve in the Fuel Supply System of APU (보조 동력 장치 연료 공급용 서보밸브의 유동 특성 해석)

  • Kim, S.S.;Chang, S.M.;Jeong, H.S.;Ryu, H.;Lee, S.H.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.5 no.4
    • /
    • pp.10-16
    • /
    • 2008
  • In this paper, the authors benchmark a servo valve model for the fuel supply system of Auxiliary Power Unit (APU) in the KHP helicopter. This valve is directly driven with a torque motor, and the size of small gap controlled by a flapper can make change of flow rate under given pressure drop between inlet and outlet. CFD analyses using a commercial code, ANSYS-CFX 10 are performed for the series of three-dimensional models at various openness conditions. The computational results on simplified models show that CFD can play a fine roll in the design of flow path as well as in the estimation of flow force due to its precision and good repeatability. Consequently, the CFD analysis helps valve designers to understand its flow characteristics from the basis of physical fundamentals.

  • PDF

A numerical study of the flow field in the IRWST of KNGR (차세대원자로 재장전수조내의 유동장에 대한 수치해석적 연구)

  • Kang Hyung Seok;Kim Hwan Yeol;Yoon Juhyeon;Bae Yoon Yeong;Park Jong Kyun
    • 한국전산유체공학회:학술대회논문집
    • /
    • 1999.05a
    • /
    • pp.205-212
    • /
    • 1999
  • Safety Depressurization System of the Korean Next Generation Reactor prevents the Reactor Coolant System from over-pressurization by discharging the coolant with high pressure and temperature into the In-containment Refueling Water Storage Tank(IRWST) during an accident. If temperature in the IRWST rises above the temperature limit of $200\;^{\circ}F$ due to the discharged coolant, an unstable steam condensation may occur and cause large load on the IRWST wall. To investigate whether this condition can be reached or not for the design basis accident, the flow and temperature distributions of water in the IRWST wire calculated by using CFX 4.2 computer code. The results show that the local water temperature does not exceeds the temperature limit within the transient time of 5 seconds.

  • PDF

Experimental and Numerical Study of Low NOx Multi-Staged Burner in the Test Combustor (시험용 연소로에서의 다단 저 NOx 버너의 실험 및 수치적 연구)

  • Choi, Yun-Ki;Kang, Kyung-Tae;Lim, Ki-Suk;Ko, Dong-Wan;Kim, Yong-Mo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.11
    • /
    • pp.1339-1347
    • /
    • 2004
  • Development of the low NOx heating boiler was strongly asked due to severe air pollution and the large number of boilers in korea. Compactness of the commercial boiler was also important because of low manufacturing cost and easy installation. In this study. newly developed compact low NOx burner, using turbulent gas diffusion combustion with multi-staged air supplies and multiple fuel nozzles, was investigated. Comparison study of the new burner was performed between experimental results and computational analysis. Commercial computational fluid dynamic(CFD) program named CFX-5.6 was used for numerical analysis of the low NOx burner inside the test combustor. Comparisons of experiment data and numerical result were performed under various equivalence ratio and fuel flow rate.

Development of Atomization Spraying System for Solvent-free Paint(I) - Flow Analysis of Hydraulic Actuator - (무용제 도료용 무화 분사시스템 개발(I) - 유압 엑츄에이터의 유동해석 -)

  • Kim, Dong-Keon;Kim, Bong-Hwan;Shin, Sun-Bin
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.10 no.2
    • /
    • pp.61-66
    • /
    • 2011
  • The purpose of this paper is to design a hydraulic actuator to operate under high pressure conditions. The flow characteristics under design conditions of hydraulic actuator were numerically conducted by commercial fluid dynamic code(ANSYS CFX V11). The numerical analysis was performed by transient technique according to the variation of stroke times, which was changed from 0 to 1 second by interval of 0.01. Turbulence model, $k-\omega$ SST was selected to secure more accurate prediction of hydraulic oil flow. The ICEM-CFD 11 and CFXMesher, reliable grid generation software was also adapted to secure high quality grid necessary for the reliable analysis. According to the simulation results, the flow rate which was supplied to the hydraulic actuator was 30.4l/min. These results are in good agreement with design results within 3.5% error.

A Numerical Study of Turbulent Flow and Heat Transfer due to Slot-jet impinging on a Moving flat plate (이동평판에 작용하는 슬롯 충돌제트의 유동 및 열전달에 관한 수치적 연구)

  • Lee, Jong-Seok;Kim, Dong-Keon;Kim, Moon-Kyung;Yoon, Soon-Hyun;Kim, Bong-Hwan
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2798-2803
    • /
    • 2008
  • The confined slot air jet impinging normally on a moving flat surface has been investigated numerically by using commercial CFD code Ansys CFX-V11. Turbulent flows are modeled using k-w turbulence model. Two-dimensional turbulent flow is considered. Calculations were conducted for a nozzle-to-plate spacing of eight slot nozzle width, at three Reynolds number(Re=4500, 6700 and 10,000) and four surface-to-velocity ratios i.e. 0, 0.25, 0.5 and 1. Results are compared against corresponding cases for heat transfer from a stationary plate. Local Nusselt number is calculated under constant wall temperature condition. The analysis reveals that the average Nusselt number increases considerably with the jet exit Reynolds number, but decrease with the plate velocity.

  • PDF

Numerical Investigation of the Flow Pulsation in the Gap connecting with Two Parallel Channels with Different Cross-section Areas (크기가 다른 단면을 가진 평행한 두 채널을 연결하는 협소유로의 맥동유동에 관한 수치해석)

  • Seo, Jeong-Sik;Hong, Seong-Ho;Shin, Jong-Kuen;Choi, Young-Don
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2810-2815
    • /
    • 2008
  • Flow pulsation in the gap connecting with two parallel channels is investigated by RANS and URANS approaches. The two parallel channels are connected by a small channel called for a gap. The parallel channels are designed to have different cross section area with its ratio of 0.5. Computations are conducted using a CFX 11.0 code. The bulk Reynolds number is 60,000. Predicted results are compared with the previous experimental result. Mean velocity profile at the center of gap region are compared with experiments for its validation. Spectral analysis on the lateral velocity in the center of the gap is presented. Auto and cross correlation for the axial-flow velocity pattern are presented. The unsteady structure of the flow pulsation was visualized in the region of the gap in the parallel channel.

  • PDF

A CFD Study on Wells Turbine Flap for Wave Power Generation (CFD에 의한 파력발전용 웰즈터빈의 플랩에 관한 연구)

  • Kim, J.H.;Kim, B.S.;Choi, M.S.;Lee, Y.W.;Lee, Y.H.
    • 유체기계공업학회:학술대회논문집
    • /
    • 2003.12a
    • /
    • pp.520-525
    • /
    • 2003
  • A numerical investigation was performed to determine the effect of airfoil on the optimum flap height using NACA0015 Wells turbine. The five double flaps which have 0.5% chord height difference were selected. A Wavier-Stokes code, CFX-TASCflow, was used to calculate the flow field of the Wells turbine. The basic feature of the Wells turbine is that even though the cyclic airflow produces oscillating axial forces on the airfoil blades, the tangential force on the rotor is always in the same direction. Geometry used to define the 3-D numerical grid is based upon that of an experimental test rig. This paper tries to analyze the optimum double flap of Wells turbine with the numerical analysis.

  • PDF

Hydraulic and Structural Analysis for APR1400 Reactor Vessel Internals against Hydraulic Load Induced by Turbulence

  • Kim, Kyu Hyung;Ko, Do Young;Kim, Tae Soon
    • International Journal of Safety
    • /
    • v.10 no.2
    • /
    • pp.1-5
    • /
    • 2011
  • The structural integrity assessment of APR1400 (Advanced Power Reactor 1400) reactor vessel internals has been being performed referring the US Nuclear Regulatory Commission regulatory guide 1.20 comprehensive vibration assessment program prior to commercial operation. The program is composed of a hydraulic and structural analysis, a vibration measurement, and an inspection. This paper describes the hydraulic and structural analysis on the reactor vessel internals due to hydraulic loads caused by the turbulence of reactor coolant. Three-dimensional models were built for the hydraulic and structural analysis and then hydraulic loads and structural responses were predicted for five analysis cases with CFX and ANSYS respectively. The structural responses show that the APR1400 reactor vessel internals have sufficient structural integrity in comparison with the acceptance criteria.

  • PDF

Numerical Simulation for Heat Transfer and Fluid Flow in the Channel with $45^{\circ}$ Incinlined Rib ($45^{\circ}$ 경사진 거칠기가 설치된 채널에서 유체유동과 열전달에 대한 수치모사)

  • Oh, S.K.;Kang, H.K.;Kim, M.H.;Bae, S.T.;Ahn, S.W.
    • Journal of Power System Engineering
    • /
    • v.10 no.1
    • /
    • pp.25-33
    • /
    • 2006
  • 거칠기가 한 벽면과 두 벽면에 설치된 사각채널에서 비압축성 유체유동과 열전달을 조사하기위해 3차원 수치모사를 행하였다. CFX (version 5) software package 를 사용하여 계산하였다. 거친 벽은 $45^{\circ}$경사진 거칠기가 설치되어 있다. 채널의 4 벽면은 일정한 열 유속으로 가열하였다. 수치계산 결과는 실험값과 잘 일치 하였다. 연구의 조건은 거칠기 피치와 높이의 비가 8이고, 거칠기 높이와 채널 수력직경의 비가 0.067이며, 레이놀즈수의 범위는 7,600에서 24,900이었다. 연구의 결과는 열전달계수와 마찰계수는 사각채널에서 거친 벽면의 수가 클수록 증가 함을 보였다.

  • PDF

CFD Analysis of 72.5kV${\sim}$800kV GIS with Moving Grid (이동격자를 이용한 72.5kV${\sim}$800kv 초고압 차단기 유동해석)

  • Yoon, J.H.;Choi, B.H.;Lee, K.H.;Yoon, C.Y.;Koh, K.S.;Min, B.S.;Park, I.S.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.799-801
    • /
    • 2002
  • To develop GIS (Gas Insulated Switchgear), prediction of the flow field including pressure in GIS is very important. The transport phenomena in GIS including arc is also being studied in these days. In this study, to predict the arc behaviour for GIS with voltage rating up to 800kV developed by HHI (Hyundai Heavy Industries Co. Ltd.), the analysis of flow and electric field in GIS were investigated. To simulate the compressible flow in GIS, the CFX, commercial CFD code, was used. The movement of the piston and the electrode of the GIS was simulated with moving grid method, which was superior to the method of varying the property of cells in the aspect of accuracy and convergence of solution. The calculated maximum pressure within the puffer cylinder was matched with experimental data within 5% error. Also, the oscillation of pressure in GIS after the movement of electrode was well predicted.

  • PDF