The Effects to Indoor Air Quality as Ventilation System Operation in Apartment House Using CFD Simulation (공동주택에서 환기장치류 가동특성에 따른 실내공기질 변화특성에 관한 연구)

  • Kim, Seok-Keun;Yee, Jurng-Jae
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.2
    • /
    • pp.142-148
    • /
    • 2007
  • The purpose of this study is to suggest the effective ventilation strategies and control methods that can minimize energy cost maintaining acceptable IAQ level in apartment house. The effects of the air-cleaning and heat-recovery ventilation system on IAQ under various operating conditions are investigated based on the experimental and CFD analyzed results. The results can be summarized as follows. (1) When a ventilator is not operated, the concentration of several pollutants may highly show in the house even though environment-friendly building materials are applied. Therefore, a mechanical ventilation system is required to obtain proper ventilation. (2) The pollutant concentration is noticeably deceased under air-cleaning/ventilation mode of air-clinic system, however, pollutant of kitchen is stagnant, because fresh air is not carried into the kitchen. (3) When air-clinic system is only equipped at master bedroom and living room, the system does not effectively deliver fresh air throughout the whole house, and then high pollutant concentration is obtained in each room. In contrast the average pollutant concentration meets the guideline when air-clinic system is installed at each room. (4) The air-cleaning/ventilation mode significantly affects on room ventilation in comparison with ventilation mode only.

Analysis of Cooling Effect for Cooling System with Dehumidifier in Greenhouse by CFD simulation (CFD 시뮬레이션에 의한 온실포그냉방 시스템과 제습장치의 냉방효과 분석)

  • 김문기;권혁진
    • Proceedings of the Korean Society for Bio-Environment Control Conference
    • /
    • 2001.11a
    • /
    • pp.59-62
    • /
    • 2001
  • 여름철 온실내 고온 문제를 해결하기 위해 이용되는 자연환기형 포그냉방은 환기가 충분치 못할 경우 온실 내부의 습도가 증가하여 증발 효율이 떨어지는 문제가 발생한다. 제습장치를 이용하여 온실 내부의 상대습도를 낮추면 증발 냉각 효율을 높일 수 있을 것으로 생각된다. 본 연구에서는 제습장치를 이용한 포그냉방 온실에 대한 CFD 모델을 개발하여 온실의 열환경 및 수분 환경을 분석하고자 한다. (중략)

  • PDF

Numerical modeling of ICP with pulsed dc bias using CFD-ACE+ (CFD-ACE+를 이용한 ICP + pulsed dc bias system의 수치 모델링)

  • Ju, Jeong-Hun
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2009.10a
    • /
    • pp.127-127
    • /
    • 2009
  • 고밀도 유도 결합 플라즈마와 함께 -1 kV의 높은 펄스 직류 바이어스를 이용한 플라즈마 공정 장치를 CFD-ACE+를 이용하여 시변 모델로 해석하였다. 수 kHz의 낮은 펄스주파수와 $5{\mu}s$의 빠른 펄스 상승 시간의 효과에 의한 플라즈마 특성을 모사한 결과 전자 온도의 상승과 그에 의한 플라즈마 가열은 펄스 상승 시간 보다 수 ${\mu}s$늦게 발생하였으며 쉬스의 팽창은 Ar 10 mTorr에서 약 20 mm정도이며 계산된 전자 온도는 최고 20 eV에 이른다.

  • PDF

The Development of Fire Test Facility using the Numerical Analysis (차량 화재시험장치 설계를 위한 수치해석적 연구)

  • Yoo, Yong-Ho;Kim, Heung-Youl
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.919-922
    • /
    • 2008
  • The objective of this study is to design the full-scale fire test facility of the railroad vehicle with CFD simulation. In the results, the step expansion system should be good enough for the measuring system. Uniform flow is achieved at eight-to-ten diameters of the expanded duct behind the step for moderate expansion ratios($D_{orifice}/D_{duct}$ = 2 being a good choice). To optimization of the fire products collector system with 5 dampers, the additional CFD simulation was also carried out. These results will be help for the railroad fire safety research.

  • PDF

Design of the Heat Exchanger in Pool Water Management System of a Research Reactor and Estimation of the Pool Water Temperature Using CFD (전산유체해석을 이용한 연구용원자로 수조수관리계통 열교환기 설계 및 수조수 온도 예측)

  • Jeong, Namgyun
    • Journal of Energy Engineering
    • /
    • v.25 no.2
    • /
    • pp.45-51
    • /
    • 2016
  • The pool water management system, which is installed for purification of the coolant in the pools and the primary cooling system of a research reactor, removes the decay heat from the reactor core when the primary cooling system stops. It also removes the heat generated from the irradiated objects in the service pool and the spent fuels in the spent fuel storage pool to keep the temperature of the pools within a limited value. In this study, the heat exchanger of the pool water management system is designed by CFD method using a commercial code Flowmaster, and the temperature of the pools is estimated along the time to conclude the design and operation method of the pool water management system.

Application of CFD Simulation to Cooling System Design of Agricultural Products Processing Center Workplace (농산물산지유통센터 작업장의 냉방 설계를 위한 CFD 시뮬레이션 적용)

  • Kwon, Jin-Kyung;Lee, Sung-Hyun;Moon, Jong-Pil;Lee, Su-Jang;Kim, Keyong-Won
    • Journal of Bio-Environment Control
    • /
    • v.19 no.4
    • /
    • pp.195-202
    • /
    • 2010
  • Cooling air-conditioning of APC (Agricultural Products processing Center) workplace is important to improve the working environment in the summer season. As existing cooling systems for air-conditioning of whole workplace are inefficient because of their high equipment operating costs, relatively inexpensive cooling system is required. The objectives of this study were to simulate the thermal flow fields in APC workplace having the positive and negative pressure type fan and pad systems and spot cooling system by using CFD software (FLUENT, 6.2) and estimate the cooling effectiveness of respective cooling systems. The results showed that the negative pressure type fan and pad system was inappropriate for the present APC workplace because of excessive outside air influx from open gateway and the positive pressure type fan and pad system created relatively low temperature field but non-uniform velocity field at worker positions. The spot cooling system could supply cool air to worker positions with relatively constant air velocity and temperature.

Effects of Differential Heating by Land-Use types on flow and air temperature in an urban area (토지 피복별 차등 가열이 도시 지역의 흐름과 기온에 미치는 영향)

  • Park, Soo-Jin;Choi, So-Hee;Kang, Jung-Eun;Kim, Dong-Ju;Moon, Da-Som;Choi, Wonsik;Kim, Jae-Jin;Lee, Young-Gon
    • Korean Journal of Remote Sensing
    • /
    • v.32 no.6
    • /
    • pp.603-616
    • /
    • 2016
  • In this study, the effects of differential heating by land-use types on flow and air temperature at an Seoul Automated Synoptic Observing Systems (ASOS) located at Songwol-dong, Jongno-gu, Seoul was analyzed. For this, a computation fluid dynamics (CFD) model was coupled to the local data assimilation and prediction system (LDAPS) for reflecting the local meteorological characteristics at the boundaries of the CFD model domain. Time variation of temperatures on solid surfaces was calculated using observation data at El-Oued, Algeria of which latitude is similar to that of the target area. Considering land-use type and shadow, surface temperatures were prescribed in the LDAPS-CFD coupled model. The LDAPS overestimated wind speeds and underestimated air temperature compared to the observations. However, a coupled LDAPS-CFD model relatively well reproduced the observed wind speeds and air temperature, considering complicated flows and surface temperatures in the urban area. In the morning when the easterly was dominant around the target area, both the LDAPS and coupled LDAPS-CFD model underestimated the observed temperatures at the Seoul ASOS. This is because the Kyunghee Palace located at the upwind region was composed of green area and its surface temperature was relatively low. However, in the afternoon when the southeasterly was dominant, the LDAPS still underestimated, on the while, the coupled LDAPS-CFD model well reproduced the observed temperatures at the Seoul ASOS by considering the building-surface heating.

Prediction of Explosion Risk for Natural Gas Facilities using Computational Fluid Dynamics (CFD) (전산유체역학시뮬레이션을 이용한 도시가스 설비의 폭발위험성 예측)

  • Han, Sangil;Lee, Dongwook;Hwang, Kyu-Suk
    • Journal of the Korean Applied Science and Technology
    • /
    • v.35 no.3
    • /
    • pp.606-611
    • /
    • 2018
  • City natural gas is classified flammable hazardous gas and should be secured according to explosion risk assessment determined by Industrial Standard KS C IEC. In this study, leak size, ventilation grade and effectiveness were adopted to the KS C IEC for risk assessment in natural gas supply system. To evaluate the applicability of the computational fluid dynamics (CFD), the risk assessment was studied for four different conditions using hypothetical volume($V_z$) valuesfrom gas leak experiments, KS C IEC calculation, and CFD simulation.

Rotor Blade Design of a 1MW Class HAWT and Evaluation of Aerodynamic Performance Using CFD Method (1MW급 수평축 풍력터빈 로터 블레이드 설계 및 CFD에 의한 공력성능 평가)

  • Mo, Jang-Oh;Lee, Young-Ho
    • The KSFM Journal of Fluid Machinery
    • /
    • v.15 no.1
    • /
    • pp.21-26
    • /
    • 2012
  • In this investigation, the aerodynamic performance evaluation of a 1MW class blade has been performed with the purpose of the verification of target output and its clear understanding of flow field using CFD commercial code, ANSYS FLUENT. Before making progress of CFD analysis the HERACLES V2.0 software based on blade element momentum theory was applied for confirmation of quick and approximate performance in the preliminary stage. The blade was designed to produce the target output of a 1MW class at a rated wind speed of 12m/s, which consists of five different airfoils such as FFA W-301, DU91-W250, DU93-W-210, NACA 63418 and NACA 63415 from hub to tip. The mechanical power by CFD is approximately 1.195MW, which is converted into the electrical power of 1.075MW if the system loss is considered to be 0.877.

Study on Energy Saving Possibilities through Analysis of Environment Control Elements & Natural Ventilation Performance using the CFD & Measurement (CFD와 실측을 이용한 환경제어요소 도입 및 주택 자연환기 성향 검토를 통한 에너지 절감가능성 고찰)

  • Oh, Byoungchull;Lee, Sunyoung
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.6
    • /
    • pp.27-37
    • /
    • 2014
  • Heat island is caused by changes of land coverage structure of cities and use of energy in buildings. As a result energy use in buildings get to increase further followed by rising of GHG emission and deteriorating climate change. Eco-friendly housing complex is a kind of plan that applies environmental control elements like water and green spaces to housing complex. With these methods, it can be expected to create thermal environment of indoor and outdoor. In this paper quantitative examination is studied on using CFD to find out the effects of river, water permeable, parks and planting on thermal environment. And by comparing field measurements with CFD results which are aimed to development phase housing complex, feasibility and usability of the CFD analysis results are confirmed. And also, analysis on the ventilation performance followed by natural ventilation system is analyzed by selecting one building in housing complex. Based on the results, the possibilities of energy reduction through making thermal environment and applying natural ventilation are studied. With these outcomes, creating thermal conditions and using natural ventilation would be contributed to GHG reduction.