• 제목/요약/키워드: CFD:Computational Fluid Dynamics

검색결과 2,015건 처리시간 0.035초

대심도 지하정거장에서 수직구 위치에 따른 수치적 연구 (NUMERICAL STUDY WITH VENT SHAFT POSITION IN UNDERGROUND STATION)

  • 오현주;신대용;이상건;김동현;김찬중
    • 한국전산유체공학회지
    • /
    • 제17권1호
    • /
    • pp.36-43
    • /
    • 2012
  • When a high-speed train passes an underground station, large pressure waves are generated due to the piston effect. These pressure waves can cause the problems of vibration and noise as well as the ear discomfort of passengers at the underground station. This work numerically analyzed the pressure wave generation and propagation in an high-speed railway underground station, and the optimal location for vent shafts was studied to improve the passenger comfort by reducing the magnitude of the pressure wave and its rate of change. The evolution of pressure field in the underground station was calculated using a CFD(Computational Fluid Dynamics) software(Fluent), where the axis-symmetric two-dimensional model verified by Wu was used. And this study is applied to modelling of the underground station and the tunnel from Daegok station A-line of GTX(Great Train Express). From the result, we can have a conclusion that the role of vent shafts respectively were different according to the position in and out the underground station. Also Vent shaft in the underground station widely reduced pressure magnitude. And vent shaft out underground station reduced initial pressure peak value. Double vent shafts installed at tunnel toward station entrance and inside of the tunnel are the most efficient to reduce pressure. and pressure reduction increases according to the number of vent shaft.

새만금 방조제에 의한 풍력터빈 입사풍 변화의 전산유동해석 (Computational Flow Analysis on Wind Profile Change Projected to a Wind Turbine Behind Saemangeum Seawall)

  • 우상우;김현구
    • 신재생에너지
    • /
    • 제9권1호
    • /
    • pp.6-11
    • /
    • 2013
  • Jeollabuk-do has announced a future plan for the Saemangeum Wind Farm which includes the installation of fourteen wind turbines in a single line, located 500m back from the Saemangeum Seawall. It is anticipated as a positive effect that, for sea breeze blowing toward land, the average wind speed could be accelerated and the wind speed distribution could be uniformized by dint of the seawall, an upstream structure of the turbines. At the same time it is also anticipated as a negative effect that the strength of wind turbulence could be increased due to the flow separation generated at the back end of the seawall. According to the results of the computational fluid dynamics analysis of this paper, it has been observed that, at the 50m zone on the road surface located at the uppermost part of the Saemangeum Seawall, the average wind speed has been accelerated by approximately 6~7% and that wind shear has been decreased by 70%, but this positive effect disappears in the zone situated beyond the 100m from the back end of the seawall. It has also been observed that flow separation exists to a limited extent only below the bottom of the blade-sweeping circle and, furthermore, does not extend very far downstream of the wind. As a conclusion, it can be said that the seawall neither positively nor negatively affects the proposed Saemangeum Seawall Wind Farm layout.

Flank Milling 공법적용을 위한 자동차용 터보차져 임펠러의 설계체험 (DESIGNING EXPERIENCE OF AUTOMOTIVE TURBOCHARGER IMPELLER FOR FLANK MILLING)

  • 방중철
    • 한국전산유체공학회지
    • /
    • 제18권4호
    • /
    • pp.1-8
    • /
    • 2013
  • The performance of small-size impellers with ruled surfaces was investigated for flank milling over a wide speed range, using computational fluid dynamics analyses and gas bench tests. An impeller with a ruled surface was designed, manufactured, and tested to evaluate the effects of blade loading, the backsweep angle, and the relative velocity distribution on the compressor performance. The simulations and tests were completed using the same compressor cover with identical inlet and outlet channels to accurately compare the performance of the abovementioned impeller with a commercial impeller containing sculptured blades. Both impellers have the same number of blades, number of splitters, and shroud meridional profiles. The backsweep angles of the blades on the ruled impeller were selected to work with the same pinched diffuser as for a sculptured impeller. The inlet-to-exit relative velocity diffusion ratio and the blade loading were provided to maximize the flow rate and to minimize the surge flow rate. The design flow rate, rpm, were selected same for both impellers. Test results showed that for the compressor stage with a ruled impeller, the efficiency was increased by 0.32% with an extended surge margin without a reduction in the pressure ratio as compared to the impeller with the sculptured design. It was concluded that an increased relative velocity diffusion coupled with a large backsweep angle was an effective way to improve the compressor stage efficiency. Additionally, an appropriate blade loading distribution was important for achieving a wide operating range and higher efficiency.

직교격자 기반 수치기법을 이용한 선박의 대변위 운동해석 (Analysis of Large-Amplitude Ship Motions Using a Cartesian-Gridbased Computational Method)

  • 양경규;남보우;이재훈;김용환
    • 대한조선학회논문집
    • /
    • 제49권6호
    • /
    • pp.461-468
    • /
    • 2012
  • In this study, a Cartesian-grid method based on finite volume approach is applied to simulate the ship motions in large amplitude waves. Fractional step method is applied for pressure-velocity coupling and TVD limiter is used to interpolate the cell face value for the discretization of convective term. Water, air, and solid phases are identified by using the concept of volume-fraction function for each phase. In order to capture the interface between air and water, the tangent of hyperbola for interface capturing (THINC) scheme is used with weighed line interface calculation (WLIC) method which considers multidimensional information. The volume fraction of solid body embedded in the Cartesian grid system is calculated using a level-set based algorithm, and the body boundary condition is imposed by a volume weighted formula. Numerical simulations for the two-dimensional barge type model and Wigley hull in linear waves have been carried out to validate the newly developed code. To demonstrate the applicability for highly nonlinear wave-body interactions such as green water on the deck, numerical analysis on the large-amplitude motion of S175 containership is conducted and all computational results are compared with experimental data.

파손된 기름 탱크로부터의 유출양 산정을 위한 기초 연구 (A Preliminary Study for the Prediction of Leaking-Oil Amount from a Ruptured Tank)

  • 김우전;이영연
    • 한국해양환경ㆍ에너지학회지
    • /
    • 제4권4호
    • /
    • pp.21-31
    • /
    • 2001
  • 바다에서 발생하는 유조선 등으로부터의 기름 유출사고는 해양환경을 크게 훼손하는 재앙에 속한다. 이러한 사고에 효과적으로 대응하기 위해서는 사고의 초기에 기름의 유출양을 정확히 판단하여 그에 적절한 대응방법을 수립하는 것이 필요하다. 기름 유출양의 추정을 위해서 사용되는 가장 간단한 방법은 토리첼리의 평형관계식을 사용하는 것이다. 하지만 이러한 평형관계식은 관성력과 점성력이 무시되었기 때문에 실제의 현상과는 다소 거리가 있다. 본 논문에서는 탱크로부터의 기름 유출양 산정을 위한 기초적인 실험과 수치계산을 수행하였다. 소형 유리 수조에 상자모양의 아크릴 기름탱크를 설치하고 종횡비가 다른 사각형의 유출구를 빠져나가는 기름의 양과 모양을 계측하였다. 그리고 유한체적법과 VOF법 등의 CFD 기술을 활용하여 기름과 물의 유동을 수치 시뮬레이션 하였다. CFD 계산견과는 실험에서 계측된 값과 좋은 일치를 보였으며, 복잡한 해난사고에서의 유출양 산정을 위한 CFD 기술의 활용가능성을 확인할 수 있었다. 본 논문의 실험조건에서 기름의 유출속도는 유출구의 형상에 따라 결정되는 유출구 내부의 마찰력에 의해 달라지며, 토리첼리 평형관계식으로부터 얻어지는 유출속도의 35~55%임을 알 수 있었고, 만약 유출구의 두께를 무시하면 종횡비에 상관없이 52%로 일정하게 추정되었다.

  • PDF

흡수정의 유동해석 (Flow analysis of the Sump Pump)

  • 정한별;노승희
    • 한국산학기술학회논문지
    • /
    • 제18권3호
    • /
    • pp.673-680
    • /
    • 2017
  • 흡수정은 댐이나 저수지에 저장된 물을 흡입하여 사용하는 설비이다. 흡입한 다량의 물은 화력 및 원자력 등의 대형 발전소의 냉각시스템에 사용된다. 특징으로 흡입 유량과 흡수정의 비가 작으면 흡입구 주변에서 유속이 증가한다. 이로 인해 와류나 선회류의 불균형 유동이 발생된다. 불균형 유동은 흡수정의 성능을 저하나 고장의 원인이 된다. 해결하기 위한 다양한 방법이 고안되고 있으나 최저수위 일 경우 정확한 해결 방법을 찾지 못하고 있다. 가장 효율적인 해결방법으로는 AVD를 설치하거나 관로를 길게하는 방법이 있다. 이렇게 설치된 구조물이 유동의 흐름을 균일하게 만들어 주기 때문이다. 본 논문에서는 관로의 길이와 AVD의 형태 변화에 따른 흡수정 내의 유동특성을 수치해석으로 분석한다. 수치해석을 위하여 수정의 흡입부, 섬프, 펌프의 3단계로 분리하여 모델링하였다. 격자는 해석의 정확도를 위해 흡입부는 비조밀, 흡수정과 AVD는 조밀하게 하였다. ANSYS ICEM-CFD 14.5를 이용하여 120~150만개의 격자를 생성하였고 Tetra grid와 Prism grid를 혼용하였다. 해석을 위해 상용 CFD 프로그램인 ANSYS CFX14.5의 SST 난류모델을 선정하였다. 조건으로 H.W.L 6.0m, L.W.L 3.5, Qmax 4.000 kg/s, Qavg 3.500 kg/s Qmin 2.500 kg/s로 설정하였다. 보텍스 각도와 속도분포로 해석한 결과는 다음과 같다. Ext E-type의 AVD를 설치한 흡수정이 최고수위 일때 합격하였다. 추후, Ext E-type을 기본으로 하여 최저수위일 때 만족하는 연구가 필요하다.

태백시 소각로 내 NOx 제거를 위한 전산유체역학(CFD) simulation 연구 (Study on Computational Fluid Dynamics(CFD) Simulation for De-NOx in the incinerator at Taebaek city)

  • 김지현;박영구
    • 한국응용과학기술학회지
    • /
    • 제30권2호
    • /
    • pp.320-332
    • /
    • 2013
  • 소각로 내 공기 주입은 연소가스의 체류시간, 미연분 제거 및 출구가스 온도 제어 등의 많은 영향을 끼친다. 이에 따라 2차 연소용 공기량을 변화시켜 충분한 체류시간을 확보하고 $850^{\circ}C$ 이상의 출구가스 온도를 유지하며, 높은 turbulent를 관리함으로써 안정적인 소각로 운영이 되어야만 한다. 본 연구에서는 현재 운영 중인 소각장의 소각로를 설계하고, 평균 일일 소각량을 바탕으로 1차 공기량을 산정한 후 2차 공기량을 변화하여 CFD 프로그램(Fluent)을 통해 이론적인 공기유동을 규명하였다. 또한 산정된 공기량을 바탕으로 실제 운영 중인 소각장에 적용함으로써 최적의 연소조건을 도출하였다. CFD simulation 결과 1.2차 공기비는 75:25가 최적의 결과로 나타났으며, 2차 공기 분사노즐 전 후면 유속 비는 1:3에서 가장 우수한 결과로 나타났다. 또한, 실제 운영 중인 소각로에 적용한 결과 적절한 소각로 출구온도는 질소산화물 제거 효율 및 일산화탄소 발생농도에 영향을 미치는 것으로 나타났다.

수치모형을 이용한 과부하 사각형 맨홀에서의 손실계수 산정 (Estimation of Head Loss Coefficients at Surcharged Square Manhole Using Numerical Model)

  • 김정수;임가희;임창수;윤세의
    • 한국방재학회 논문집
    • /
    • 제11권3호
    • /
    • pp.143-150
    • /
    • 2011
  • 도시 우수 배수 시스템에서 우수 관거는 개수로 흐름 상태로 가정하여 설계되었기 때문에 맨홀에서의 에너지 손실은 일반적으로 중요하게 고려되지 않았다. 그러나 과부하흐름에서 에너지 손실은 관거의 배수능력을 저하시켜 도심지역의 침수피해를 가중시키는 요인이 된다. 그러므로 과부하 사각형 맨홀 내에서의 수두 손실을 분석할 필요가 있다. 본 연구에서는 FLUENT 6.3 모형을 이용하여 과부하 사각형 합류맨홀에서의 흐름특성을 모의하고 맨홀 내 손실수두의 변화를 계산하여 손실계수를 산정하였다. 또한 실험결과와 수치모의 결과를 비교 및 분석하여 사각형 맨홀에서의 손실계수 산정에 FLUENT 6.3모형의 적용성을 확인하였다. 맨홀 폭(B)과 연결관경(d)의 비(B/d)에 따른 손실계수를 산정하였다. B/d가 증가할수록 사각형 합류 맨홀에서의 손실계수는 증가하였다. 중간 단차 맨홀에서 단차 변화에 따른 손실계수의 변화를 산정하였다. 단차가 5 cm이상 증가하면 맨홀 내 수심과 손실계수가 점진적으로 증가하였으므로 중간 맨홀에서의 적정 단차는 5 cm로 판단된다. 따라서 우수 관거 시스템의 여러 형태의 사각형 맨홀에서의 흐름의 변화 및 손실계수를 예측할 때, Fluent 6.3 모형은 사용 가능하리라 판단된다.

공동주택단지 배치유형별 열환경 영향성 분석: 유체역학 시뮬레이션을 기반으로 (Analysis of Thermal Environment Impact by Layout Type of Apartment Complexes for Carbon Neutrality Net-Zero: Based on CFD Simulation)

  • 이건원;조영태
    • 토지주택연구
    • /
    • 제14권3호
    • /
    • pp.93-106
    • /
    • 2023
  • 본 논문은 우리나라의 아파트를 대상으로 아파트 단지 유형에 따른 열환경 변화를 CFD 기법을 이용하여 시뮬레이션을 수행하고, 유형별 열환경을 평가하고자 하였다. 이를 위해 본 연구는 2000년대와 2010년대 주요 아파트 단지 유형에 대한 선행연구를 참고하여 4가지 유형을 추출한 후, 바람 유입 방향에 따른 아파트 단지 배치와 기온 변화를 분석하였다. 각 유형별로 타워형, 판상형, 혼합 주동 유형을 이용하여 표준화 모형을 제작하였으며, 이들 유형에 대해 총 8개 방향에서의 바람 유입 상황을 상정했다. 이러한 모형 및 조건을 바탕으로 CFD 시뮬레이션을 수행하였다. 그 결과, 타워형으로만 구성된 유형과 타워형을 단지 중앙에 배치하는 유형에서 바람의 방향과 상관없이 상대적으로 온도가 낮았은 것으로 나타났다. 이들 유형에서 단지 내부로 바람이 잘 유입되기 때문인 것으로 풀이되었다. 이러한 본 연구의 결과는 건물의 형태 및 단지의 배치 유형에 따라 바람의 유동 및 그에 따른 온도 분포 패턴이 상이한 것으로 나타나 설계 초기 단계에서 단지의 배치에 대한 신중한 고려가 필요함을 확인하다. 본 연구의 결과는 향후 아파트 단지의 초기 설계단계에서 지속 가능한 주거환경 조성을 위한 기초자료로 활용될 수 있을 것으로 기대된다.

역전기투석 장치 내 스페이서의 영향에 관한 수치해석적 연구 (Numerical Analysis for the Effect of Spacer in Reverse Electrodialysis)

  • 신동우;김홍근;김태환;박종수;전동협
    • 청정기술
    • /
    • 제19권1호
    • /
    • pp.1-7
    • /
    • 2013
  • 본 연구에서는 역전기투석 장치 내 스페이서(spacer)에 의한 유동변화와 스페이서의 높이변화에 따른 해수의 유동 및 이온전달 영향에 관한 연구를 수행하였다. 육각형 모양의 스페이서에 대해 3차원 전산유체해석을 진행하였다. 모델링을 수행한 결과, 레이놀즈수(Reynolds number)가 커짐에 따라 스월량(swirl)이 커지며 단위시간당 해수의 이온이 멤브레인(membrane)으로 전달되는 양이 늘어나지만, 반면에 입출구의 압력차도 증가하였다. 또한 스페이서가 두꺼울수록 파워수(Power number)와 셔우드수(Sherwood number)가 증가하였다.