• Title/Summary/Keyword: CFC

Search Result 271, Processing Time 0.02 seconds

A Study on the Performance of Heat Transfer of Low Fin Tubes Used in Cooling of the Cutting Oil of the Machine Tool (공작기계 절삭유 냉각용 낮은 핀관의 열전달 성능에 관한 연구)

  • 조동현
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 1998.10a
    • /
    • pp.125-133
    • /
    • 1998
  • Nine tubes with trapezoidal integral-fins having fin densities from 748 to 1654fpm and 10,30 grooves and finned tubes with caves of 0.55 and 0.64mm height respectively are tested. A plain tube having same diameter as the finned tubes is also tested for comparison. In case of condensation CFC-11 condensates at saturation state of 32$^{\circ}C$ on the outside surface cooled by inside cooling water flows. And in case of boiling the refrigerant evaporates at a saturation state of 1bar on the outside tube surface and heat is supplied by hot water which circulates inside of the tube. The tube having fin density of 1299fpm and 30grooves has the best condensation overall heat transfer coefficient. However, as far as boiling heat transfer coefficient concerns, fin tubes with cave show higher value than low fin tube having fin density of 1299fpm and 30 grooves.

  • PDF

A STUDY OF VALVE DESIGN PROCEDURE IN HERMETIC COMPREESOR (왕복동식 압축기 밸브의 설계)

  • 조성욱;박성근;김형석;임종윤
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1992.10a
    • /
    • pp.98-103
    • /
    • 1992
  • 전세계적인 에너지 절약과 환경보존에 대한 관심과 요구가 증가함에 따라 소비전력규제와 CFC삭감에 대응한 국제경쟁력 확보가 중요한 과제로 대두 되고 있다. 이러한 상황변화에 따라 냉동 공조기기의 심장부인 압축기에 대 해서도 고효율 및 저소음화의 요구가 한층 높아졌다. 따라서 가혹한 환경에 도 견딜 수 있는 압축기의 개발은 필수적이라 할 수 있다. 소형밀폐형 압축 기는 크게 두 부분으로 나뉘어진다. 그 하나는 모터에 의한 회전구동부이고, 다른 하나는 실린더와 피스톤 그리고 밸브로 구성된 압축기구부이다. 그 중 에서 밸브는 진동 및 소음에 영향을 미치는 기본요소가 된다. 압축기의 밸브 는 근본적으로 밸브포트와 실린더 형상에 의해 결정되며, 이런 형상조건하에 서 밸브는 연속적인 운전이 되어야 하므로, 그 응답성이 좋아야 하고 무엇보 다도 자체의 신뢰성도 확보되어야 한다. 따라서 밸브의 동적특성과 응력 분 포를 정확히 예측하는 것이 중요한 과제가 된다. 본 논문에서는 컴퓨터를 이 용한 밸브의 동적특성과 응력해석을 위해 밸브의 형상을 유한요소 패키지인 ANSYS를 이용하여 해석하고, 그 모델링 및 해석이 타당성을 검토하기 위하 여 동적 특성해석은 홀로그래피(Holography) 기술을 이용하여 실험하고, 응 력해석은 스트레인 게이지(strain gage)를 이용하여 결과를 얻어서 서로 비 교하여 보았다.

  • PDF

Empirical Equations for Thermodynamic Physical Properties of Freon-23 and HFC-227ea (Freon-23과 HFC-227ea의 열역학적 물성에 관한 실험식)

  • 김재덕;이윤우;송명석;노경호
    • Fire Science and Engineering
    • /
    • v.16 no.3
    • /
    • pp.16-25
    • /
    • 2002
  • For Freon-23, a conventional extinguished agent regulated by Montreal Protocol and HFC-227ea, its alternative, the empirical equations were correlated in terms of saturated pressure, density, viscosity, enthalpy and surface tension. They were obtained by regression analysis from the experimental data in the literature. The empirical equations of saturated pressure were expressed as the second and third order function of temperature. The empirical equation of density was expressed as compressibility factor and saturated pressure by a function of temperature. The empirical equation of viscosity was formulated as a power function. Heat capacities as well as enthalpies were well fitted by empirical form of the second-order temperature. Finally, surface tension simply has linear function form in terms of temperature.

Effect of Specific Surface Area on the Reaction of Silicon Monoxide with Porous Carbon Fiber Composites

  • Park, Min-Jin;Lee, Jae-Chun
    • The Korean Journal of Ceramics
    • /
    • v.4 no.3
    • /
    • pp.245-248
    • /
    • 1998
  • Porous carbon fiber composites (CFCs) having variable specific surface area ranging 35~1150 $\m^2$/g were reacted to produce silicon carbide fiber composites with SiO vapor generated from a mixture of Si and $SiO_2$ at 1673 K for 2 h under vacuum. Part of SiO vapor generated during conversion process condensed on to the converted fiber surface as amorphous silica. Chemical analysis of the converted CFCs resulting from reaction showed that the products contained 27~90% silicon carbide, 7~18% amorphous silica and 3~63% unreacted carbon, and the composition depended on the specific carbide, 7~18% amorphous silica and 3~63% unreacted carbon, and the composition depended on the specific surface area of CFCs. CFC of higher specific surface area yielded higher degree of conversion of carbon to silicon and conversion products of lower mechanical strength due to occurrence of cracks in the converted caron fiber. As the conversion of carbon to silicon carbide proceeded, pore size of converted CFCs increased as a result of growth of silicon carbide crystallites, which is also linked to the crack formation in the converted fiber.

  • PDF

Study on Subchronic Inhalation Toxicity of 1, 1-dichloro-1-fluoroethane using S.D. Rats (S.D. Rats를 1, 1-Dichloro-1-fluoroethane의 아만성 흡입독성 연구)

  • 김현영;이성배;임철홍;김철우;정용현;한정희;전윤석;최수영;강대봉
    • Environmental Analysis Health and Toxicology
    • /
    • v.17 no.1
    • /
    • pp.81-93
    • /
    • 2002
  • There were no specific effects for test materials on Sprague-Dawiey (S.D.) rats in clinical symptoms, amounts of food intakes, weight changes, laboratory findings, and pathology after whole body 1, 1-Dichloro-1-fluoroethane (used as coolant, metal cleaner and solvents) exposure (0, 1,500, 3,000, and 6,000 ppm) for 13 weeks (6 hour/day, 5 days/week). However, the loss of capillary vessels in eyeball (pupil) was observed in a female rat among 6,000 ppm group. Though there was a tendency for MCHC (Mean Corpuscular Hemoglobin Concentration) in rat to be decreased (p<0.05), it was not regarded as abnormal because the values were within normal limits. In asthma-stimulation related evaluations. there was also a tendency for inflammatory cell counts in bronchoalveolar lavages to be increased. But it had no statistical significance, and also no dependency on sex and the exposed concentration . Based on this result, the non observed effect level (NOEL) induced by 1, 1-Dichloro-1-fluoroethane inhalation was evaluated in groups with 3,000 ppm below (S.D. Rats, 13 weeks). Finally, it was concluded that the short term exposal of 1, 1-Dichloro-1-fluoroethane is not considered as a asthma stimulant by inhalation despite of some study limitations such as test animals use and short-term exposure.

A Study on Performance and Reactor Behavior of Chemical Refrigerator (화학식 냉동기의 성능 및 반응기 거동에 관한 연구)

  • Park, Seung-Hoon;Lee, Jong-Ho
    • Journal of Energy Engineering
    • /
    • v.6 no.1
    • /
    • pp.87-95
    • /
    • 1997
  • A chemical heat pump based on the reversible reactions between metal chlorides and ammonia gas is attractive alternative to compression system and liquid absorption systems in cooling and refrigerating fields. The advantages of chemical heat pump are no regulatory constants due to CFC refrigerants, utilization of gas, industrial waste heat, electricity, fuel oil etc. as heat sources and wide applications to energy storage system, large-scale energy managements for industrial process. The scale-up of chemical heat pump from laboratory prototype to pilot plants necessitates the interpretation of system performance and evaluation of dynamic behavior in the chemical reactor. This study contains the prediction of performance of chemical refrigerator according to operating condition, the dynamic simulations through reactor modelling, which is used for the calculation of reactive medium temperature and the conversion variation with reactor cooling temperature, and the effect survey of block parameters on the power of refrigerator.

  • PDF

불포화 토양내 유류성분의 포화도 평가를 위한 분배추적자의 활용 방안

  • Park Gi-Ho;Park Min-Ho;Sin Hang-Sik;Go Seok-O
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2006.04a
    • /
    • pp.20-28
    • /
    • 2006
  • Partitioning tracer tests were conducted to quantify the saturation degree of diesel and water in unsaturated soil, respectively. The use of partitioning tracers that partition into diesel, water, and air (i.e., three-phase partitioning), is in attractive alternative to traditional coring and analysis method. These gaseous partition tracers not global warming gas like CFC's are Butane, Acetylene, Ethylene, Methylene chloride, and Methane. The glass column packed with sandy soil was prepared, in which a three-phase system of air, water, and diesel was maintained. Conservative and partition gas tracers were injected into the columns and detected easily using a single GC detector(FID). For each tracer, a method of moments was used to estimate partition coefficient between water, diesel. and the air, respectively. The results from the column studies showed that the diesel/air tracer partition coefficient ranged from 8.2 to 868 and 9.2 for water/air. Saturation degree of diesel and water in the column, predicted by the partition coefficients obtained from tests, was underestimated up to 66% and 23% respectively.

  • PDF

Experimental studies on the evaporative heat transfer of R32/290 mixtures in a horizontal smooth tube (평활관 내 R32/290 혼합냉매의 증발열전달 특성에 관한 실험적 연구)

  • Cho, Jin-Min;Kim, Ju-Hyok;Yoon, Seok-Ho;Kim, Min-Soo
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.268-273
    • /
    • 2005
  • Because of environmental issues caused by CFC, HCFC or HFC refrigerants, new alternative refrigerants has gained a significant attention. This paper presents experimental information on heat transfer coefficient and pressure drop behavior during evaporation process of R32/290 mixtures in a horizontal smooth tube. A smooth tube with outer diameter of 5 mm and length of 5 m was selected as a test tube. Heat transfer coefficients and pressure drop characteristics were measured for a range of mass fluxes from 497 to 994 $kg/m^2s$, heat fluxes from 12 to 20 $kW/m^2$ and for several mixture compositions(100/0, 75/25, 58.4/41.6, 2s/75, 100/0 by wt% of R32/290). The differences of measured heat transfer characteristics among various R32/290 refrigerant mixtures were analyzed for various compositions.

  • PDF

Thermodynamic Properties of Alternatives for R12, R22 and Performances of Refrigerator (R12 및 R22대체냉매의 열역학적 물성치 및 냉동기의 성능비교)

  • Chang, S.D.;Shin, J.Y.;Ro, S.T.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.5 no.1
    • /
    • pp.73-83
    • /
    • 1993
  • Thermodynamic properties of alternatives for R12 and R22 were estimated and performances of refrigerating cycle using these refrigerants were compared. In this study, we adopt R134a, R22/R142b, R22/R152a, R22/R152a/R124 as alternatives for R12 and R32/R134a for R22. Thermodynamic properties of these refrigerants were estimated using modified CSD equation of state. Cycle simulations of the refrigerating system considering heat source were carried out in order to compare the performance of the system. R134a shows relatively lower COP than R12 but very similar VCR. R22/R142b(50/50 mass fraction), R22/R152a(10/90), R22/R152a/R124(30/25/45) are good for the substitutes of R12 and R32/R134a(30/70) is appropriate for that of R22 in view of COP and VCR.

  • PDF

자기냉동/냉장고와 공조기

  • 이종석
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.30 no.6
    • /
    • pp.49-54
    • /
    • 2001
  • 1990년대 중반부터 후반에 결쳐 미국의 Astronautics사와 Ames연구소에 의한 공동연구결과는 자기냉동이 실현 가능한기술이며 가스액화,음식 냉동 및 저장, 대규모 건물 공조 등에 있어서 기존의 증기압축냉동에 필적할 만하다는 것을 밝혔다. 더 최근의 연구와 개발 노력은 자기장 원(source)으로 $Nd_2Fe_{14}B$ 영구자석배열을 이용한 회전식 자기냉동기가 가정용 공조기나 냉동/냉장고에 사용될 수 있음을 나타내고있다. Gd 금속구를 사용한 2단 자기 냉동/냉장고의 예비설계는 냉동실 온도가 $-12^{\circ}C(10^{\circ}F)$, 냉동실 온도가 $-1^{\circ}C(30^{\circ}F)$에서 전체 성능계수 3 그리고 냉각능력 120W를 얻을 수 있음을 제시한다. 자기장 원으로서 개선된 영구자석 배열을 이용한다면 카르노 효율의 60%와 성능계수 4.5에 이를 수 있을 것으로 보여진다. 그리고 자기냉동은 오존층 파괴물질 (CFC's)이나 온설가스(HCFC's와 HFC's)를 사용하지 않기 때문에 깨끗한 환경을 만드는데 기여한다. 동시에 상용 Gd으로부터 거대한 자기열량효과를 가진 재료인 $Gd_5(Si_2Ge_2)$를 kg 단위로 생산할 수 있는 정도로 연구가 진전되었다. 이 신재료를 저렴한 가격에 얻을 수 있게 됨으로써 Gd 금속을 자기냉매로 사용하도록 설계 되었던 공조기나 냉동/냉장고의 효율이 더 좋아질 것으로 예상된다.

  • PDF