• 제목/요약/키워드: CFC

검색결과 271건 처리시간 0.03초

관악산 대기 중의 CFC-12 및 CFC-11 모니터링에 관한 연구 (A study on Monitoring for CFC-12 and CFC-11 in the atmosphere near Mt. Kwan-Ak.)

  • 김경렬;민동하;박미경;김은희;최상화;조하만;남재철
    • 한국대기환경학회지
    • /
    • 제10권1호
    • /
    • pp.41-48
    • /
    • 1994
  • A monitoring system for atmospheric CFC-12 and CFC-11 has been established at Mt. Kwan-Ak, Seoul National University (SNU) since July, 1991. The concentrations showed quite a large variation ranging from 495 to 37600 pptv (pptv=part per trillion, 10$^{-12}$ , v/v) for CFC-12 and from 233 to 12100 pptv for CFC-11 due to many local sources. However, monthly medians show rather limited ranges ; 553~765 pptv for CFC-12 and 301~431 pptv for CFC-11. Furthermore minimum concentrations could be defined relatively well during the whole period of observation. The regional background concentrations in 1993 near SNU wer estimated as 533 pptv for CFC-12 and 293 pptv for CFC-11. These values are very comparable to global averages in Northern Hemisphere, 523 pptv for CFC-12 and 287 pptv for CFC-11, reflecting the fast atmospheric mixing processes within the hemisphere. Examinations with meteorological parameters such as wind speed and direction suggest the possible measurement-window at SNU, appropriate for regional monitoring. Studies for improving the monitoring capability of the SNU station such as automation of the analysis system along with correlation with other meteorological parameters, are in progress at the present time.

  • PDF

대기중 CFC 및 Ozone의 거동에 관한 연구 (A Study on Behavior of CFC and Ozone in Atmosphere)

  • 이내우;이진우
    • 한국안전학회지
    • /
    • 제9권1호
    • /
    • pp.140-145
    • /
    • 1994
  • Contributions of global warming potentials on CFC(Chlorofluorocarbon) and Ozone were calculated by Stefan-Boltzmann's law and environmental effects of its were discussed. As the greenhouse effect on the unit volume of CFC is the most strong in the infrared gases and the destruction of Ozone in stratosphere is also depends on CFC, therefore release of CFC should be prohibited. But the effect of restriction on CFC will be appeared more than 10 years later. Eventhough the Ozone layer is related to global warming, It should be protected because of maitaining food chain mode of life, preventing human disease, for example, cataract, dermatics etc.

  • PDF

마우스에서 CFC-101 (녹농균 백신)의 감염 방어효과 (Protective Effect of CFC-101, a Pseudomonas Vaccine, in Mice)

  • 김영지;김제학;박완제;안동호;홍광희;김현수;김유삼;함경수
    • Biomolecules & Therapeutics
    • /
    • 제2권4호
    • /
    • pp.322-325
    • /
    • 1994
  • To optimize the immunological efficacy of CFC-101, an outer-membrane protein vaccine purified from relatively less pathogenic 4 different Pseudomonas aeruginosa strains, we investigated to establish its dose, administration route, interval and frequency of vaccination in mice. As expected, the 4 CFC-101 producing strains were less pathogenic than the challenging organism, P. aeruginosa GN11189. CFC-101 completely protected the death caused by P. aeruginosa at above 0.05 mg/kg vaccinized by 3 times with 7-day intervals. At the optimally effective dose of 0.2 mg/kg of CFC-101, at least 3 immunizations were necessary for complete protection against P. aeruginosa-induced death. If immunized 3 times, the immunization interval could be shortened up to 2 days to acquire the best protection against P. aeruginosa. CFC-101 was effective either by intraperitoneal, subcutaneous or intramuscular but not by oral administration. The present results show that the newly developed Pseudomonas vaccine, CFC-101, is highly effective for the protection from death caused by pseudomonal infections.

  • PDF

열전달 촉진관에서 CFC-11 및 CFC-12 대체냉매의 응축 열전달 특성 연구 (Condensation heat transfer characteristics of alternative refrigerants for CFC-11, CFC-12 for enhanced tubes)

  • 조성준;황수민;정동수;김종보
    • 설비공학논문집
    • /
    • 제10권5호
    • /
    • pp.569-580
    • /
    • 1998
  • In this study, condensation heat transfer coefficients(HTCs) of a plain tube, low fin tube, and Turbo-C enhanced tube for CFC-11, HCFC-123, CFC-12, HFC-l34a are measured and compared against each other. All data are taken at the vapor temperature of 39$^{\circ}C$ with a wall subcooling temperature 3~8$^{\circ}C$. Test results show that HTCs of a low vapor pressure refrigerant, HFC-123, for a plain, low fin, and Turbo-C tubes are 10.5~20.5%, 8.2~12.2%, 16.5~19.2% lower than those of CFC-11, respectively. On the other hand, HTCs of a medium vapor refrigerant, HFC-l34a, for a plain, low fin, and Turbo-C tubes are 20.6~31.8%, 0.0~8.0%, 13.2~20.9% higher than those of CFC-12, respectively. For all refrigerants tested, HTCs of Turbo-C tube are the highest among the three tubes showing almost 8 times increase in HTCs as compared to those of a plain tube. Nusselt's prediction equation for a plain tube yielded 12% deviation for all plain tube data while Realty and Katz's prediction equation for a low fin tube yielded 20% deviation for all low tube data.

  • PDF

CFC-101(녹농균 백신)의 능동 및 수동면역 효과 (Active and Passive Protective Effect of CFC-101 (Pseudomonas Vaccine) in Mice)

  • 박완제;조양제;김영지;김제학;박관하;김유삼;함경수
    • Biomolecules & Therapeutics
    • /
    • 제2권4호
    • /
    • pp.326-330
    • /
    • 1994
  • The treatment of pseudomonal infection is a perplexed problem because of its modest susceptibility to most of the major antibiotics. A novel Pseudomonas vaccine(CFC-101) was prepared from the outer membrane protein fractions of several Pseudomonas strains. In this study, we examined CFC-101's effectiveness in both active and passive immunization models. CFC-101 in mice at 0.2 mg/kg, i.p., given three times at two-day intervals, completely prevented the death caused by Pseudomonas aeruginosa. Antibody titer, in accordance with the protective effect in this active immunization, was elevated to its peak level following three consecutive administrations of CFC-101. Thereafter, antibody titer stayed at a constantly high level. Each outer membrane protein fraction from the four CFC-101 producers, exhibited good cross-protective effects in mouse infection models against different Fisher types of P. aeruginosa. In the passive immunization model, 21~336 $\mu\textrm{g}$/kg of anti-rabbit IgG to CFC-101, when mice being infected with a challenge strain, prevented the Pseudomonhas-induced death up to 60%. Therefore, the preventive effect of CFC-101 was verified in both the active and passive immunization models.

  • PDF

기니픽과 마우스에서 CFC-101(녹농균 백신)의 항원성시험 (Antigenicity of CFC-101(Pseudomonas vaccine) in Guinea Pigs and Mice)

  • 백남진;김달현;이동억;선우연;한형미;정승태;김필선;김현수
    • Biomolecules & Therapeutics
    • /
    • 제2권4호
    • /
    • pp.331-335
    • /
    • 1994
  • As a part of the safety evaluation of Pseudomonas vaccine(CFC-101), antigenicity tests were carried out in guinea pigs and mice. In active systemic anaphylaxis(ASA) test, guinea pigs showed no sign or only moderate sign(1/5) when sensitized and challenged with up to 200 $\mu\textrm{g}$/kg. In homologous passive cutaneous anaphylaxis(PCA) test using guinea pigs, inoculation of CFC-101 alone did not produce CFC-101-specific antibody. When inoculated with 200 $\mu\textrm{g}$/kg plus adjuvant, challenge of 200 $\mu\textrm{g}$/kg produced PCA titer of 32(5/5) but challenge of 20 $\mu\textrm{g}$/kg did not produce CFC-101-specific antibody. In heterologous PCA test using mice, CFC-101-specific antibody was not detected when sensitized with CFC-101 alone. Some animals(3/12) showed positive PCA response when inoculated with 200 $\mu\textrm{g}$/kg plus alum. In passive hemagglutination (PHA) test, although no antibody was detected at 20 $\mu\textrm{g}$/kg, inoculation of 200 $\mu\textrm{g}$/kg alone or with alum produced positive response in all animals. This result has already been predicted because CFC-101 is a vaccine developed for the purpose of immunization. From the above results, it can be concluded that there is no adverse antigenic potential up to 10 times clinical dose of 200 $\mu\textrm{g}$/kg.

  • PDF

열플라즈마에 의한 CFC의 분해공정 (Decomposition Process of CFC by Thermal Plasma)

  • 차우병;최경수;박동화
    • 공업화학
    • /
    • 제9권6호
    • /
    • pp.829-834
    • /
    • 1998
  • 환경문제와 관련하여 오존층 파괴의 주요 원인으로 알려진 CFC를 열플라즈마를 이용하여 완전하게 분해하였다. CFC113($C_2Cl_3F_3$)을 선정하여 열플라즈마 분해에서의 적절한 공정 조건을 검토하였다. 실험에 앞서, 상압에서 300 K~5000 K범위에서 CFC113, $H_2$, $O_2$간의 열역학적 화학평형조성을 고찰함으로써 CFC113의 분해 생성의 경향을 알 수 있었다. 실험은 상압, 상온에서 CFC113과 $H_2$, $O_2$혼합가스의 주입량, 그리고 냉각관 직경의 변화에 따른 분해생성물을 조사하였고 이를 기체크로마토그래피로 분석하였다. 그 결과, 각각 99.99%이상의 분해율을 보였다. CFC113/$H_2$=1/3에서 $O_2$비가 증가할수록 CO로의 전화율은 감소하였다. CFC113/$O_2$=1/1, 1/1.5, 1/2에서 $H_2$비가 3이상 증가될수록 CO로의 전화율이 증가하였다. 그 이유는 $H_2$첨가가 증가할수록 환원분위기에서 $H_2O$가 생성되고 $CO_2$생성량이 감소하기 때문이다. DC power가 증가하여도 CO로의 전화율 변화는 차이가 없었으며, 총유량이 증가할 경우 CO전화율이 약간 감소하는 경향을 보였다. 냉각관의 직경을 8 mm에서 4 mm로 작게 할 경우 빠른 냉각속도로 인하여 CO로의 전화율이 증가하였다.

  • PDF

CPC-222, A New Fluoroquinolone

  • Lee, Younha
    • 한국응용약물학회:학술대회논문집
    • /
    • 한국응용약물학회 1997년도 춘계학술대회
    • /
    • pp.12-12
    • /
    • 1997
  • CFC-222 is a novel fluoroqinolone antibacterial agent synthesized and under development by the Cheil Jedang Corporation, Korea. CFC-222 exerts the antibacterial activity by inhibition of bacterial DNA gyrase leading to bactericidal action. In in vitro and in vivo preclinical testing, CFC-222 has been shown to possess a broad spectrum of antibacterial activity. In particular CFC-222 is very potent against Gram-positive bacteria such as Staphylococcus spp., Streptocuccus spp. (in particular penicillin G-resistant and -susceptible S. pneumoniae) and Enterococcus spp. when compared to other quinolones (ciprofloxacin, ofloxacin or lomefloxacin). CFC-222 also showed potent activity against the methicillin resistant clinical isolates of S. aureus (MRSA). Against Gram-negative bacteria (E. coli, Pseudomonas and Sarcina) the activity of CFC-222 was slightly weaker than that of ciprofloxacin, but was more potent than that of ofloxacin or lomefloxacin. In urinary systemic infections caused by both Gram-positive and -negative bacteria, CFC-222 demonstrated a potent therapeutic efficacy in particular against Cram-positive bacteria S. aureus, S. pyrogen 203 and S. pneumonia TypeIII.

  • PDF

초음파조사에 의한 염화불화탄소(CFC)의 분해 (Decomposition of Chlorofluorocarbon by Sonication)

  • 임봉빈;김선태
    • 한국대기환경학회지
    • /
    • 제19권3호
    • /
    • pp.307-314
    • /
    • 2003
  • The sonolytic decomposition of chlorofluorocarbon (CFC 113) and several alternative compounds, such as HCFC 225ca, HCFC 225cb, and HFC 134a, in.aqueous solutions was investigated. The CFC 113 with a high volatility and a low solubility in water was rapidly decomposed with increasing sonication time. The decomposition rates were influenced by the initial concentration of CFC 113, the reaction temperature, and the gas/liquid phase volume ratio but were independant of the pH of solution. The predominant pathway of the decomposition of CFC 113 by sonication was not the oxidation by OH radicals but the pyrolysis with high temperature and pressure inside of the cavitation bubble. The pyrolysis in the cavitation bubble resulted in an almost complete mineralization of CFC 113 with the high efficient formation of inorganic products (Cl$^{[-10]}$ , F$^{[-10]}$ , CO, $CO_2$). The addition of zinc powder on the decomposition of CFC 113 by sonication caused an acceleration of the decomposition. Also, HCFCs and HFC 134a were found to be readily decomposed by the pyrolysis induced from the sonication.

CFC 113과 대체세정제의 세정성능 비교 (Comparison of Cleaning Performance of CFC 113 and the Alternatives)

  • 노경호;최대기;이윤용
    • 분석과학
    • /
    • 제6권5호
    • /
    • pp.521-530
    • /
    • 1993
  • 몬트리올의정서에 의하여 오존층 파괴물질로 규정된 전자산업의 필수불가결한 세정제인 CFC 113(1,1,2-trichloro 1,2,2,-trifluoroethane)의 사용이 앞으로 규제가 됨에 따라서 대체세정제의 개발이 활발히 진행되고 있다. 따라서 현재 시판중인 세정제의 종류는 상당히 많다. 이 중에서 Axarel 32(DuPont), Cleanthru 750H(KAO Chemical), EC-Ultra(Petroferm)를 선정하여 CFC 113과 세정성능을 비교하였다. CFC 113과 대체세정제의 세정성능 검사방법은 기본적은 물성측정, 재질호환성에 대한 실험, 증발속도의 측정, 오염물질의 제거효율에 관한 실험으로 구성되어 있다. CFC 113과 대체세정제들의 기본적인 물성들은 서로 상이하였다. 대체세정제는 비점이 높고 표면장력과 점도가 CFC 113보다 큰 값을 가지고 있다. 전자산업에서의 로진계 flux를 오염물질로 하고 각기의 세정제와의 용해도를 비교한 결과 비극성 유기물질은 abietic acid에 대한 용해도는 서로 유사하였으나 대체세정제의 경우 극성 유기물질에 대한 용해도는 CFC 113에 비해서 월등히 좋았다. 또한 비점이 낮은 CFC 113의 건조성은 대체세정제와는 비교할 수 없을 정도로 우수하였고 특히 대체세정제 중에서 EC-Ultra는 건조성이 매우 낮았다. CFC 113과 대체세정제에서의 PCB의 구성 재질인 FR4와 Cu-coated FR4에 대한 재질호환성은 거의 비슷하였다. Abietic acid의 제거효율에 관한 실험에서는 초음파 세정에 의해서 우수한 세정효과를 보여 주었으며 침적에 의해 세정에서는 건조성이 좋은 세정제가 유리하지만 초음파 세정에 의해서 대체세정제간의 제거효율의 차이는 거의 없었다. CFC 113의 대체세정제로서 로진계 flux를 제거하는 대체세정제간의 세정성능은 큰 차이는 없으나 최종 세정제로 선정하기 위해서는 세정장치의 적용, 환경문제 및 경제성의 고려가 병행되어야 한다.

  • PDF